Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Jupiter”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Laboratory studies of the newly discovered infrared band at 4705.2 cm-1 (2.1253 micrometers) in the spectrum of Io: the tentative identification of CO2.

We discuss over 120 laboratory experiments pertaining to the identification of the new absorption band discovered by Trafton et al. (1991) at 4705.2 cm-1 (2.1253 micrometers) in the spectrum of Io. It is shown that this band is not due to overtones or combinations of the fundamental bands associated with the molecules (or their chemical complexes) already identified on Io, namely, SO2, H2S, and H2O. Thus, this band is due to a new, previously unidentified, component of Io. Experiments also demonstrate that the band is not due to molecular H2 frozen in SO2 frosts. Since the frequency of this band is very close to the first overtone of the nu 3 asymmetric stretching mode of CO2, we have investigated the spectral behavior of CO2 under a variety of conditions appropriate for Io. The profile of the Io band is not consistent with the rotational envelope expected for single, freely rotating, gaseous CO2 under Io-like conditions. It was found that pure, solid CO2 and CO2 intimately mixed in a matrix of solid SO2 and H2S produce bands with similar widths (5-10 cm-1), but that these bands consistently fall at frequencies about 10-20 cm-1 (approximately 0.007 micrometer) lower than the Io band. CO2 in SO2 : H2S ices also produces several additional bands that are not in the Io spectra. The spectral fit improves, however, as the CO2 concentration in SO2 increases, suggesting that CO2-CO2 interactions might be involved. A series of Ar : CO2 and Kr : CO2 matrix isolation experiments, as well as laboratory work done elsewhere, show that CO2 clustering shifts the band position to higher frequencies and provides a better fit to the Io band. Various laboratory experiments have shown that gaseous CO2 molecules have a propensity to cluster between 80 and 100 K, temperatures similar to those found on the colder regions of Io. We thus tentatively identify the newly discovered Io band at 4705.2 cm-1 (2.1253 micrometers) with CO2 multimers or "clusters" on Io. Whether these clusters are buried within an SO2 frost, reside on the surface, or are in a residual, steady-state "atmospheric aerosol" population over local coldtraps is not entirely clear, although we presently favor the latter possibility. The size of these clusters is not well defined, but evidence suggests groups of more than four molecules are required. The absorption strength of the 2 nu 3 CO2 cluster overtone determined in the laboratory, in conjunction with the observed strength of the Io band, suggests that the disk-integrated abundance of CO2 is less than 1% that of the SO2. Studies of the sublimation behavior of CO2 indicate that it probably resides predominantly in the cooler areas (< 100 K) of Io. The relative constancy of the Io feature over a variety of orbital phases suggests that the polar regions may contain much of the material. Some consequences of the physical properties of CO2 under conditions pertinent to Io are discussed. The presence of CO2 clusters on Io could be verified by the detection of any one of several other infrared bands associated with the CO2 molecule, of which the strongest are the nu 3 12CO2 asymmetric stretch fundamental near 2350 cm-1 (4.25 micrometers) and the nu 2 bending mode fundamental near 660 cm-1 (15.1 micrometers). Weaker bands that may also be detectable include the nu 3 13CO2 asymmetric stretch fundamental near 2280 cm-1 (4.39 micrometers), the 2 nu 2 + nu 3 combination/overtone band near 3600 cm-1 (2.78 micrometers), and the nu 1 + nu 3 combination band near 3705 cm-1 (2.70 micrometers).

Astronomical Phenomena↗

A new class of absorption feature in Io's near-infrared spectrum.

We report our discovery of an absorption feature in the infrared spectrum of Io centered at 2.1253 micrometers (4705.2 cm-1). This band is marginally resolved at resolving power 1200 with a deconvolved full width at half-maximum (FWHM) of about 4 cm-1. This contrasts with the 30- to 50-cm-1 widths of the broad absorption features previously detected at longer wavelengths which arise from mixtures of SO2 with H2S and H2O. This newly discovered feature is relatively weak, having a core only 5% below the continuum at this resolving power. Our survey from 1.98 to 2.46 micrometers (5050-4065 cm-1) at this same resolving power revealed no other feature greater than 1% of the continuum level shortward of 2.35 micrometers, and 3% elsewhere. The feature does not correspond to any gas- or solid-phase absorption that might be expected from previously identified constituents of Io's surface. No temporal or longitudinal variation has been detected in the course of 18 nights of observation over the past year and no significant variation in the strength of the feature was seen during an emergence from eclipse. These observations indicate that the source material of the feature is reasonably stable, and is more uniformly distributed in longitude than Io's hot spots. These characteristics all indicate that the feature belongs to a class different from those characterizing other known absorption features in Io's spectrum. Consequently, it should reveal important new information about Io's atmosphere-surface composition and interaction. A series of laboratory experiments of plausible surface ices indicates that (i) the band does not arise from overtones or combinations of any of the molecular vibrations associated with species already identified on Io (SO2, H2S, H2O) or from chemical complexes of these molecules, (ii) the band does not arise from H2 trapped in SO2, and (iii) the band may arise from the 2 nu3 mode of CO2. If the band arises from CO2, it is clear from its detailed shape and position that the molecules are not embedded in an SO2 matrix, as are H2S and H2O, but may be present as multimers or "clusters."

Atmosphere↗

Impact-generated atmospheres over Titan, Ganymede, and Callisto.

The competition between impact erosion and impact supply of volatiles to planetary atmospheres can determine whether a planet or satellite accumulates an atmosphere. In the absence of other processes (e.g., outgassing), we find either that a planetary atmosphere should be thick, or that there should be no atmosphere at all. The boundary between the two extreme cases is set by the mass and velocity distributions and intrinsic volatile content of the impactors. We apply our model specifically to Titan, Callisto, and Ganymede. The impacting population is identified with comets, either in the form of stray Uranus-Neptune planetesimals or as dislodged Kuiper belt comets. Systematically lower impact velocities on Titan allow it to retain a thick atmosphere, while Callisto and Ganymede get nothing. Titan's atmosphere may therefore be an expression of a late-accreting, volatile-rich veneer. An impact origin for Titan's atmosphere naturally accounts for the high D/H ratio it shares with Earth, the carbonaceous meteorites, and Halley. It also accounts for the general similarity of Titan's atmosphere to those of Triton and Pluto, which is otherwise puzzling in view of the radically different histories and bulk compositions of these objects.

Atmosphere↗

Implants of pure titanium for internal fixation of the peripheral skeleton.

In a multicentre study, a clinical evaluation of the new titanium implants of the sizes 2.7, 2.0 and 1.5 mm was done. In seven centres, 133 patients were operated on and the personal, subjective opinions of the surgeons were recorded. In the opinion of these surgeons experienced in using steel implants, the outcome of the internal fixations was the same for titanium as for steel implants. Three metal-related complications occurred in the smallest size screw type (1.5 mm), namely, one screw broke and two bent. In the cases in which the implant had been removed, good tissue contact with the implant could be seen. Only in one case was there discolouring of the soft tissue due to titanium. It is recommended that surgeons who are used to handling stainless steel screws should be aware of the slightly different behaviour of titanium screws.

Adolescent↗

Low-contact dynamic compression plating of the clavicle.

Internal fixation of the clavicle is rarely necessary. When it is warranted, the clavicle's complex three-dimensional morphology and functional anatomy, proximity to vital structures, and the multidirectional biomechanical forces acting upon it place considerable demands on any implant used for skeletal fixation. We treated nine clavicles with the recently-introduced 3.5 mm low contact-dynamic compression plate (LC-DCP). Surgery was performed for symptomatic non-union in six patients, shoulder dysfunction following a malunited fracture in one, for an open fracture in one, and for an acute fracture associated with brachial plexus injury in one. After an average follow-up period of 17 months union was secured in each case. The advantages afforded by the 3.5 mm LC-DCP in internal fixation of the clavicle with its uniquely demanding anatomical and biomechanical characteristics are discussed.

Adolescent↗

Blade plate fixation of proximal humeral non-unions.

Non-union of fracture of the proximal humerus is unusual and can be difficult to treat. It is found more often than not in the elderly patient with weak bone, resorption at the fracture site, contracture of the glenohumeral joint and associated medical conditions. A blade plate, designed specifically for the treatment of these non-unions, was used in nine patients--seven females and two males (mean age 66 years)--who had painful non-union with a mean duration of 22.5 months. Autologous bone grafting was used in all cases. Eight non-unions followed displaced two-part proximal humeral fractures: five had been initially treated conservatively and four with medullary nails. Five patients had associated medical illness. After a mean of 6.5 months (range 4-28 months), union had been achieved in all but one patient. Functional evaluation revealed good results in five patients, fair results in three and one poor result. Use of the blade plate offered a successful method of stable internal fixation in these complex cases.

Aged↗

The application of the limited contact dynamic compression plate in the upper extremity: an analysis of 114 consecutive cases.

We sought to assess the clinical effectiveness of a new plate design which offers improved biological and biomechanical features, the limited contact dynamic compression (LCDC) plate. We analysed 114 LCDC plates applied consecutively for upper extremity fractures or reconstruction in 94 patients. Three patients were lost to follow-up, leaving 111 plates in 91 patients followed to definitive fracture/osteotomy outcome. Thirty-seven plates were applied for reconstruction in 35 patients, including 11 where standard implants had failed. Fifty-six patients had 74 plates applied for acute fractures including 12 open fractures, 23 multiply injured patients, 26 patients with concomitant fractures and seven associated neurovascular injuries. All patients were followed to definitive outcome. Union was achieved at an average of 10.7 weeks in 105 platings, while three delayed unions eventually united without further intervention, an overall union rate of 108/111, or 97.3 per cent. There were no mechanical failures of the plates or screws. In this large series a union rate of 97.3 per cent with no implant failures confirms its clinical application for traumatic and reconstructive problems in this area. Improved contouring, easier screw placement, decreased interference with cortical bone blood flow and excellent union rates are definite short-term advantages. Theoretical long-term benefits of decreased stress-shielding and lower refracture rates will require longer follow up.

Adolescent↗

Contoured LCDC plating of the proximal ulna.

Comminuted fractures of the proximal ulna, particularly in combination with dislocation of the radial head, represent complex injuries which threaten both elbow and forearm motion. Thirty-seven complex proximal ulna fractures were treated with a dorsally applied, limited-contact titanium plate, contoured to fit the anatomy of the olecranon and proximal ulna. Twenty-four patients had Monteggia fracture/dislocations, and 13 had isolated but complex fractures of the proximal ulna. After an average follow up of 24 months, good or excellent functional results were achieved in 27 patients.

Adolescent↗

Germane photochemistry. Photolysis of gas mixtures of planetary interest.

Photolysis of germane (GeH4) in the presence of acetylene (C2H2), propyne (C3H4) or phosphine (PH3) with a 185 nm mercury lamp has been studied. The volatile products formed in these reactions are characterized by 1H, 31P and 13C NMR. Vinylgermanes are the first reaction products formed in the photolysis of GeH4 with alkynes. A reaction pathway is proposed. The initial step is the dissociation of germane 1 to hydrogen and GeH3 radicals. Addition of the germyl radical on alkyne is proposed as the next step. Vinyl-germanes are then formed by radical combination. Photolysis of ethenylgermane 2 gives diethenylgermane 3 in the presence of acetylene and digermaethane 4 in the presence of GeH4. The application of these findings to Jovian and Saturn atmospheric chemistry is discussed.

Acetylene↗

Effects of cyclosporin A and predegeneration on survival and regeneration of peripheral nerve allografts in rabbits.

Axonal regeneration across 64 median nerve grafts in 34 rabbits was studied histologically to determine the optimal conditions for nerve allografting. Axonal regeneration across allografts in cyclosporin A-treated animals was satisfactory, but it occurred more slowly and with more inflammation and fibrosis than in autografts. Without immunosuppression, fresh allografts were rejected. However, in immunocompetent hosts, allografts rendered less immunogenic by predegeneration were not rejected, and axonal regeneration occurred. The combination of cyclosporin A and nerve graft predegeneration produced the most substantial axonal regeneration, comparable to autografts. The observations suggest that nerve allograft survival may be optimally effected by cyclosporin A treatment coupled with reduction in the immunogenicity of the grafts, such as by predegeneration.

Animals↗

Results of flexor tendon tenolysis after replantation in the hand.

Thirty-seven replanted digital units and four thumb replantations had a flexor tendon tenolysis at an average of 10 months after replantation. The results were assessed by measuring total active motion, potential active motion, and by the formula of Strickland and associates. The total active motion increased from a mean pretenolysis of 72 degrees to 130 degrees. The potential active motion increased from a mean of 43% to 70% after tenolysis. Both of these improvements were statistically significant (p less than 0.001). The formula of Strickland and associates rated 13 excellent, 11 good, 6 fair, and 11 poor. The thumbs had two fair results and two poor results. Poor results were also seen in crush or avulsion amputations, hands with more than two digits amputated, and those requiring a proximal interphangeal joint capsulotomy. Little difference was found related to the number of arteries or tendons repaired. Complications included tendon rupture and infection. No digits were lost. The results of this study would support flexor tendon tenolysis after replantation of fingers but not replanted thumbs.

Adolescent↗

Extensor carpi ulnaris and flexor carpi ulnaris tenodesis of the unstable distal ulna.

A procedure for stabilizing the distal ulna using the extensor carpi ulnaris and flexor carpi ulnaris is described. Seven patients who had sustained posttraumatic distal ulnar dorsal instability and articular degeneration and one patient with instability caused by rheumatoid arthritis were operated on. All eight obtained stable ulnae with mean motion of 62 degrees of supination and 86 degrees of pronation (mean increase of 32 degrees of supination and 43 degrees of pronation). Follow-up averaged 28 months (range, 18 to 63 months). The tenodesis, using a weave of a distally-based slip of flexor carpi ulnaris and a proximally-based slip of extensor carpi ulnaris combined with a Darrach procedure, is a reliable, reproducible salvage procedure for stabilizing the degenerated distal radioulnar joint and for salvaging the symptomatic unstable ulna after excessive distal ulna resection.

Adult↗

Kaposi's sarcoma in the hand seen as an arteriovenous malformation.

A case of Kaposi's sarcoma, which was initially thought to represent an arteriovenous malformation, is described. Angiographic findings were misleading, and careful histopathological analysis of such lesions is advocated so that correct treatment may be carried out.

Aged↗

Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions.

Computer-assisted design and manufacturing technology has been used to create solid models of five unusually complex, multidirectional malunions of distal radius fractures. Preoperative planning was dramatically enhanced by the ability to perform the surgical procedure on these models, with a model of the uninjured limb used for comparison. All five patients had significant malunions, with malrotation in the horizontal plane in five and an impacted articular fragment in two. A satisfactory outcome was achieved in each case.

Adult↗

Intraoperative distraction in the treatment of complex nonunions of the radius.

Two unique cases of complex nonunions of the radius are presented. Each was characterized by bone loss, disruption of the distal radioulnar joint, and loss of axial alignment. Indirect reduction and lengthening of the radius were accomplished intraoperatively with the use of a femoral distractor, and the nonunion was treated with autogenous iliac crest graft and a long AO/ASIF dynamic compression plate. A functional result occurred in each case.

Adult↗

A microsurgical suction mat.

We describe a suction mat used to maintain a bloodless field during microsurgery. The mat is inexpensive, can be quickly fashioned from readily available operating room items, and functions with exceptional reliability.

Humans↗

Clinical results of tension band fixation of avulsion fractures of the hand.

We report 100 cases in which a tension-band technique was used to secure fixation of avulsion fractures within the digits. Included are 51 bony mallet fractures that were subluxed or irreducible, 38 displaced bony gamekeeper's fractures of the thumb, 8 fractures of the lateral phalangeal base, and 3 avulsion fractures that involved the base of the dorsal aspect of the middle phalanx. We evaluated results on the basis of clinical and x-ray film criteria. Excellent or satisfactory results were found in all 38 bony gamekeeper's injuries. All but one gamekeeper's fracture healed; the one nonunion was asymptomatic. All eight patients with lateral avulsion fractures had an excellent or satisfactory result on clinical examination. Seven of the eight had an excellent result on x-ray film evaluation; the one malnuion was asymptomatic. Two of the three fractures with dorsal avulsions of the base of the middle phalanx had a satisfactory result on clinical and x-ray film examination; the one poor result was due to the severity of the comminution of the fracture. However, 21 of the 51 bony mallet injuries had a poor result both clinically and radiographically. We noted numerous postoperative complications including dorsal skin breakdown, superficial and deep infection, and secondary displacement of the fragment. Tension-band fixation is an excellent method for treating various avulsion fractures of the hand such as bony gamekeeper's thumb, lateral avlusion injuries, and dorsal avulsions of the middle phalanx. However, the treatment of bony mallet fingers with tension band fixation is less predictable and should be used with caution.

Adult↗