Influence of friction at articular surfaces of the temporomandibular joint on stresses in the articular disk: a theoretical approach with the finite element method.

The present study was designed to assess stress and displacement of the temporomandibular joint (TMJ) disk during jaw opening with different frictional coefficients (micro) from 0.0001 to 0.5 at the TMJ disk and bony component interfaces using three-dimensional finite element (FE) models of individual TMJs based on magnetic resonance (MR) images. An asymptomatic female volunteer and a female patient with anterior disk displacement without reduction were selected, and serial sagittal and frontal slices of their MR images were used for the TMJ reconstruction procedure. The condylar movement was recorded during jaw opening by a Gnatho-hexagraph and used as the loading condition for the subsequent stress analysis of the model. In the asymptomatic subject, relatively high von Mises stresses were observed in the anterior and lateral regions of the disk during jaw opening, and the superior boundary, contacting with the glenoid fossa, exhibited lower stresses than those on the inferior boundary facing the condyle. In the symptomatic subject, although the stress value in the disk was relatively low, the posterior connective tissue exhibited high stress throughout jaw opening. Additional increments in stress values and disk displacement were observed as the coefficient of friction increased, especially in the asymptomatic subject. It is concluded that an augmentation in the friction between the disk, glenoid fossa, and condyle produces an increment in stress and displacement of the disk.

Adult↗

A comparison between friction and frictionless mechanics with a new typodont simulation system.

This study was designed to explore the differences between friction and frictionless mechanics for maxillary canine retraction with the use of a new typodont simulation system, the Calorific machine system. The unit was designed to observe the whole process of tooth movement and is composed of 3 parts: a temperature regulating system, electrothermodynamic teeth, and an artificial alveolar bone component. The efficiency of maxillary canine retraction was compared with the sliding mechanics (along a.016 x.022-in stainless steel labial arch and nickel-titanium closed coil spring) and a canine retraction spring. The patterns of tooth movement obtained with both of these mechanics were measured 5 times each. Friction mechanics were superior to frictionless mechanics in terms of rotational control and dimensional maintenance of the arch (P <.0001); frictionless mechanics were shown to be more effective at reducing tipping and extrusion (P <.0001). However, the observed differences between the 2 methods were relatively small in terms of their clinical significance, and no differences were found in anchorage control (P =.2078). In conclusion, this study indicated that friction and frictionless mechanics perform similarly.

Alveolar Process↗

The effects of reconditioning on the slot dimensions and static frictional resistance of stainless steel brackets.

This study investigated the effects of reconditioning on the slot dimensions and the static frictional resistance of stainless steel brackets at 0, 5, and 10 degrees bracket/archwire angulation. A sample of 45 used, commercially reconditioned 0.018 x 0.030 inch stainless steel standard edgewise brackets was compared with a matched sample of 45 new brackets. The slot dimensions of 15 new and 15 reconditioned brackets were examined using a photomicroscope. With new brackets both the occluso-gingival slot width (mean = 0.0197 inch) and slot depth (mean = 0.0304 inch) exceeded the manufacturer's nominal dimensions of 0.018 x 0.030 inch. The reconditioning process resulted in a further increase in slot width (mean = 0.0205 inch), which was statistically significant (P = 0.028), and a reduction in slot depth (mean = 0.0291 inch), which was highly statistically significant (P = 0.002). This may be attributable to preferential metal removal by the electro-polishing phase of the reconditioning process. Friction testing of 30 new and 30 reconditioned brackets demonstrated that both showed an increase in binding effects as the bracket/archwire angulation was increased from 0 to 5-10 degrees. However, the changes in slot dimensions secondary to reconditioning did not result in a statistically significant difference in mean static frictional resistance when the two bracket types were compared. Although the brackets were altered physically by the reconditioning process, their performance during simulated sliding mechanics was not adversely affected. This implies that reconditioning may not result in clinically significant effects.

Dental Polishing↗

Dynamic frictional behaviour of orthodontic archwires and brackets.

The aim of this study was to evaluate the frictional behaviour of 15 different archwires and 16 different brackets using small oscillating displacements when opposed to a standard stainless steel bracket or a standard stainless steel wire. Tests were run according to a pilot study at a frequency of 1 Hz and with a reciprocating tangential displacement of 200 microm, while the wire remained centred in the bracket slot under a load of 2 N. The results indicated a significant difference between the evaluated wires and brackets. The mean coefficient of friction (COF) of the wires varied from 0.16 for Imagination NiTi tooth-coloured wire to 0.69 for the True Chrome Resilient Purple wire, while for the brackets it ranged from 0.39 for Ultratrimm to 0.72 for the Master Series. The fact that in this study, a large number of different commercially available archwires and brackets were evaluated with the same apparatus according to the same protocol, allows a direct comparison of the different archwire and bracket combinations, and can assist in the choice of the optimal bracket-wire combination with regard to friction.

Analysis of Variance↗

Dielectric fluctuations and the origins of noncontact friction.

Dielectric fluctuations underlie a wide variety of physical phenomena, from ion mobility in electrolyte solutions and decoherence in quantum systems to dynamics in glass-forming materials and conformational changes in proteins. Here we show that dielectric fluctuations also lead to noncontact friction. Using high sensitivity, custom fabricated, single crystal silicon cantilevers we measure energy losses over poly(methyl methacrylate), poly(vinyl acetate), and polystyrene thin films. A new theoretical analysis, relating noncontact friction to the dielectric response of the film, is consistent with our experimental observations. This work constitutes the first direct, mechanical detection of noncontact friction due to dielectric fluctuations.

Computer Simulation↗

Frictional insertion kinetics of bone biopsy needles.

Patients undergoing a percutaneous bone biopsy often complain of pain during needle insertion, despite local anesthesia. Bone biopsy needles are typically inserted with combined axial and twisting motions. These motions could cause pain through frictional heating or direct mechanical irritation. The hypothesis of this study is that the insertion energy of bone biopsy needles can be reduced by modifying the insertion kinetics or by adding a friction-lowering coating to the needles. Jamshidi bone biopsy needles were driven into a bone analog model by an MTS materials testing machine operating under axial and rotational displacement control. The load/torque recordings showed that, to significantly decrease insertion energy and peak resistance to needle insertion, axial velocity and angular frequency had to be decreased to one quarter of the baseline, typical-usage parameters. However the increased insertion time may not be acceptable clinically. The majority of the insertion energy was associated with the needle axial thrust rather than with needle twisting. Overcoming friction against the side of the needle consumed much more of the insertion energy than did the process of cutting per se. None of five needle coatings tested succeeded in appreciably lowering the insertion energy, and none achieved a substantial decrease in peak resisting force.

Biopsy, Needle↗

Rubber friction on smooth surfaces.

We study the sliding friction for viscoelastic solids, e.g., rubber, on hard flat substrate surfaces. We consider first the fluctuating shear stress inside a viscoelastic solid which results from the thermal motion of the atoms or molecules in the solid. At the nanoscale the thermal fluctuations are very strong and give rise to stress fluctuations in the MPa-range, which is similar to the depinning stresses which typically occur at solid-rubber interfaces, indicating the crucial importance of thermal fluctuations for rubber friction on smooth surfaces. We develop a detailed model which takes into account the influence of thermal fluctuations on the depinning of small contact patches (stress domains) at the rubber-substrate interface. The theory predicts that the velocity dependence of the macroscopic shear stress has a bell-shaped form, and that the low-velocity side exhibits the same temperature dependence as the bulk viscoelastic modulus, in qualitative agreement with experimental data. Finally, we discuss the influence of small-amplitude substrate roughness on rubber sliding friction.

Computer Simulation↗

Ulnar groove plasty for friction neuropathy at the elbow.

In this paper, we report on a new operation for ulnar neuropathy caused by friction at the elbow. The operation consists of ulnar groove plasty proximal to the cubital tunnel. The ulnar nerve is replaced into this reconstructed groove. Patients are relieved of discomfort, and motor and sensory functions are recovered. The nerve is kept stable throughout the full range of elbow motion and showed neither irritation nor adhesion. Friction ulnar neuropathy is traditionally treated by anterior transpositon or medial epicondylectomy. The ulnar nerve may become entrapped in scar tissue after these operations. We believe that this anatomical position is optimum for the nerve and that this procedure is essential for treatment of friction neuropathy.

Adolescent↗

Roughness-dependent friction force of the tarsal claw system in the beetle Pachnoda marginata (Coleoptera, Scarabaeidae).

This paper studies slide-resisting forces generated by claws in the free-walking beetle Pachnoda marginata (Coleoptera, Scarabaeoidea) with emphasis on the relationship between the dimension of the claw tip and the substrate texture. To evaluate the force range by which the claw can interact with a substrate, forces generated by the freely moving legs were measured using a load cell force transducer. To obtain information about material properties of the claw, its mechanical strength was tested in a fracture experiment, and the internal structure of the fractured claw material was studied by scanning electron microscopy. The bending stress of the claw was evaluated as 143.4-684.2 MPa, depending on the cross-section model selected. Data from these different approaches led us to propose a model explaining the saturation of friction force with increased texture roughness. The forces are determined by the relative size of the surface roughness R(a) (or an average particle diameter) and the diameter of the claw tip. When surface roughness is much bigger than the claw tip diameter, the beetle can grasp surface irregularities and generate a high degree of attachment due to mechanical interlocking with substrate texture. When R(a) is lower than or comparable to the claw tip diameter, the frictional properties of the contact between claw and substrate particles play a key role in the generation of the friction force.

Animals↗

Friction in orthopaedic zirconia taper assemblies.

The torque resistance of zirconia ceramic heads/titanium taper trunnion junctions was tested in accordance with ISO 7206-9:1994(E); using twelve modified heads of 32 mm diameter under representative physiological conditions. Test parameters studied included assembly force, vertical load during test (test load) and head length. Mean torque resistances measured were 8.9 N m for a 1 kN test load and 15 N m at 4 kN test load. Coefficients of friction calculated for the torsional stability ranged from 0.06 to greater than 1.0. Multiple regression analysis confirmed that the failure torques measured were significantly dependent on test load (beta = 0.77; P < 0.001) whereas assembly force and head length played a lesser, insignificant, part in the variation. Data from push-on/pull-off tests were used to calculate coefficients of friction under axial loading, which were significantly correlated with taper angle and material. Torque testing shows greater variability than push-on/pull-off tests for similar combinations, and for zirconia heads on other tapers. The coefficients of friction measured (0.16-0.31) are significantly different from values typically used in stress analyses.

Biocompatible Materials↗

Influence of proteoglycan contents and of tissue hydration on the frictional characteristics of articular cartilage.

In this work, the hypothesis that water content and substances present on the articular surface play an important role in lubrication through the formation of a layer with a high content of water on the articular surface is analysed. The hydrophilic properties of proteoglycans exposed at the articular surface and hydration of tissue are the main responsible factors for the formation of this layer. The role of the articular surface in the frictional characteristics of articular cartilage was examined using specimens (femoral condyles of pigs) with intact and wiped surfaces tested in intermittent friction tests. Results indicated that the intact condition presented low friction in comparison with the wiped condition. The measured water loss of the articular cartilage after sliding and loading indicated a gradual decrease in the water content as the time evolved, and rehydration was observed after the submersion of unloaded specimens in the saline bath solution. Micrographic analyses indicated the presence of a layer covering the articular surface, and histological analyses indicated the presence of proteoglycans in this superficial layer. The hydration of the cartilage surface layer and proteoglycan in this layer influence lubrication.

Animals↗

The frictional behaviour of explanted PCA hip prostheses.

The frictional characteristic of 22 explanted and two unused PCA total hip arthoplasties were assessed using the Durham hip simulator. The friction of the explanted joints was not found to be significantly different from that of the unused joints. In contrast, explanted Charnley joints often exhibit increased frictional characteristics. This discrepancy is accounted for by the lack of cement ingression in the PCA design.

Adult↗

Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions.

Conventional joint replacements consist of a polished metallic or ceramic component articulating against a layer of polyethylene. Although the friction in the contact between these articulating surfaces is low, polyethylene wear is produced as a result of a boundary/mixed lubrication regime. Wear debris is generated by direct asperity contact, abrasion, adhesion and fatigue, and has been shown to cause adverse tissue reactions which can lead to joint failure. The introduction of soft compliant materials, similar in stiffness to articular cartilage, has shown that with cyclic loading and relative motion between the articulating surfaces typical of normal walking, a fluid film can be maintained through combined entraining and squeeze-film actions, and hence wear can be minimized. For 95 per cent of the time, however, we are not walking but standing still or moving slowly. A pendulum simulator has been used in the present study to investigate the effect of adverse tribological conditions which may lead to fluid film breakdown, such as severe cyclic loading, particularly in the swing phase, reduced sliding velocity, reduced stroke length and start-up after a period of constant loading. Friction of a model composite cushion knee bearing, manufactured from a graded modulus (20-1000 MPa) layer of polyurethane, sliding against a polished metal cylinder has been measured for various lubricants and the results have been analysed using a Stribeck assessment. Severe cyclic loading, decreased sliding velocity and decreased stroke length have been found to limit the degree of fluid entrainment previously allowed during the swing phase of normal walking, thus allowing breakdown of fluid films and elevated levels of friction and surface damage. Soft layer joint replacements must therefore be designed to operate with thick elastohydrodynamic fluid films to provide some degree of protection when tribological conditions become severe, or alternatively incorporate alternative boundary or mixed lubrication mechanisms. This study quantifies a potential limitation of the cushion bearing concept.

Elasticity↗

Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding.

Computational wear models need input data from valid tribological tests. For the wear model of a total hip prosthesis, the contact pressure dependence of wear and friction of ultra-high molecular weight polyethylene (UHMWPE) against polished CoCr in diluted calf serum lubricant was studied, and useful input data produced. Two test devices were designed and built: a heavy load circularly translating pin-on-disc (HL-CTPOD) wear test device and an HL-CTPOD friction measurement device. Both can be used with a wide range of loads. The wear surface diameter of the test pin was kept constant at 9 mm, whereas the load was varied so that the nominal contact pressure ranged from 0.1 to 20 MPa. The wear factor decreased with increasing contact pressure, whereas the coefficient of friction first increased with increasing contact pressure with low pressure values and then decreased. Up to the pressure of 2.0 MPa, the wear mechanisms and wear factors were in good agreement with clinical findings. In the critical range of 2.0-3.5 MPa, the wear mechanisms and wear factors started to differ from clinical ones, and the decrease of the wear factor steepened. The discrepancy became more and more evident as the pressure was gradually increased beyond 3.5 MPa. It appears that the pressure value of 2.0 MPa should not be exceeded in pin-on-disc wear tests that are to reproduce the clinical wear of UHMWPE acetabular cups.

Acetabulum↗

Sliding friction analysis of phosphatidylcholine as a boundary lubricant for articular cartilage.

Dipalmitoyl phosphatidylcholine (DPPC), the major lipidic component of the synovial fluid (45 per cent), has been implicated in previous studies in synovial joint lubrication as a potential boundary lubricant for articular cartilage. The purpose of this study was to evaluate the effectiveness of DPPC as a boundary lubricant at physiological stresses experienced by weight-bearing joints (up to 7.5 MPa). The sliding coefficients of static and kinetic friction for glass surfaces coated with DPPC layers of physiological thickness (70 nm) were measured as a function of average contact stress, contact geometry (point and line), applied load and relative velocity (from 25 to 0 mm/s) and compared to the coefficient of friction for clean glass in the same conditions. The coefficient of friction for DPPC-lubricated surfaces was dependent on contact geometry, obeyed Amonton's law (not dependent on axial load or contact area), was dependent on relative velocity within the range stated and was an effective lubricant at physiological stresses. This study showed that dipalmitoyl phosphatidylcholine can be an effective boundary lubricant at stresses observed in load-bearing joints. Because of their surface-active nature, these adsorbed molecules might also act as a protective layer for the articular surfaces.

Animals↗

[The HEPFIEx simulator, a device for determination of friction between femur head prosthesis and cartilage].

We describe a device designed to investigate friction between various femoral head prostheses and human acetabula. It enables not only the determination of friction and the relevance of the play between the femoral head and acetabulum, but also the evaluation of the kinematic behaviour of bipolar prostheses. In the simulator, the various femoral head prostheses are placed on a special cone and tested against a human cadaveric acetabulum. The swiveling range of the device is uniaxial, and the swiveling angle is +/- 35 degrees. The maximum force produced pneumatically is 5kN. Testing of the simulator with a TEP was successful and friction-coefficients of < 0.1 were measured, as are reported in the literature.

Acetabulum↗

The effects of static friction and backlash on extended physiological proprioception control of a powered prosthesis.

In general, externally powered prostheses do not provide proprioceptive feedback and thus require the user to rely on cognitively expensive visual feedback to effectively control the prosthesis. Applying the concept of extended physiological proprioception (EPP) to externally powered prostheses provides direct feedback to the user's proprioceptive system regarding the position, velocity, and forces applied to the prosthesis. However, electric elbows with EPP controllers developed at the Northwestern University Prosthetics Research Laboratory have exhibited unexplained "jerky" behavior in both clinical fittings and bench-top operation. In addition, the development of limit cycles, a specific type of constant-amplitude oscillation, had been observed in bench-top use of these elbows. Backlash and static friction within the EPP system were found to be primarily responsible for the development of limit cycles. Reducing static friction and backlash improved the system's performance. These results suggest that to most effectively implement EPP, prosthesis manufacturers should design prosthetic components that minimize static friction and backlash.

Arm↗

Frictional forces required for unrestrained locomotion in dairy cattle.

Most free-stall housing systems in the Netherlands are equipped with slatted or solid concrete floors with manure scrapers. A slipping incident occurs when the required coefficient of friction (RCOF) exceeds the coefficient of friction (COF) at the claw-floor interface. An experiment was conducted to measure ground reaction forces (GRF) of dairy cows (n = 9) performing various locomotory behaviors on a nonslippery rubber-covered concrete floor. The RCOF was determined as the ratio of the horizontal and vertical components of the GRF. It was shown that during straight walking and walking-a-curve, the RCOF reached values up to the COF, whereas for sudden stop-and-start responses, the RCOF reached values beyond the maximum COF that concrete floors can provide. Our results indicate that concrete floors do not provide enough friction to allow natural locomotory behavior and suggest that tractional properties of floors should be main design criteria in the development of better flooring surfaces for cattle.

Animals↗