Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ejection fraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

GPER stimulation attenuates mitochondrial dysfunction and cardiac dysfunction in ovariectomized mice with heart failure with preserved ejection fraction (HFpEF).

BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) is prevalent among postmenopausal women and is strongly linked to estrogen deficiency. G-protein coupled estrogen receptor (GPER) mediates non-genomic estrogen signalling and exerts cardiovascular protective effects. Its role in the pathogenesis of HFpEF remains unclear. This study aimed to explore whether GPER activation could attenuate mitochondrial dysfunction and cardiac damage in ovariectomized (OVX) mice with HFpEF. METHODS: Circulating GPER levels were measured in postmenopausal women with HFpEF and healthy controls. A correlation analysis was performed to assess the associations between GPER and cardiac function. Female C57BL/6J mice underwent ovariectomy and were fed with high-fat diet and l-NAME to induce HFpEF. Mice were treated with the GPER agonist G-1 for 4 weeks. Cardiac function, histological changes, oxidative stress, mitochondrial function and mitophagy were evaluated in vivo and in vitro. RESULTS: Serum GPER levels were significantly higher in postmenopausal women with HFpEF and correlated with NT-proBNP and E/e'. In OVX mice with HFpEF, GPER expression was up-regulated, and G-1 improved diastolic function, reduced myocardial hypertrophy and oxidative stress. Importantly, G-1 restored mitochondrial ATP production, normalized mitochondrial dynamics and promoted mitophagy in vivo and in vitro. These effects were associated with activation of the AMPK/ULK1 pathway. Inhibition of AMPK diminished the protective effects of G-1 in cardiomyocytes. CONCLUSIONS: GPER agonist G-1 ameliorated mitochondrial dysfunction, promoted mitophagy and alleviated cardiac diastolic dysfunction in OVX mice with HFpEF, partially through the AMPK/ULK1 pathway, indicating GPER as a therapeutic target for postmenopausal women with HFpEF.

AMPK/ULK1 signalling pathway↗

Comparison of segmental and global ejection fraction in ischaemic heart disease.

In order to evaluate whether segmental ejection fraction (SEF) is a better index of left ventricular (LV) performance than global ejection fraction (EF), 25 patients with significant coronary stenosis and normal EF were studied. SEF was estimated from the LV cineangiogram after dividing the LV into eight segments by means of a long axis and three equally spaced chords perpendicular to it. The area of a given segment was measured in the end-diastole and the end-systole and SEF was calculated by determining the percent decrease in area for each segment. 12 out of the 25 patients presented hypokinesis, akinesis or dyskinesis of at least two segments; the inferior apical and both diaphragmatic segments were the regions most frequently affected. In 7 patients, these abnormalities were compensated by hyperkinesis of two or three other segments, whereas in the remaining 5 patients contraction abnormalities were not accompanied by hyperkinesis in spite of a normal EF. It is concluded that SEF is a more sensitive index of regional LV function than EF in patients with ischaemic heart disease.

Coronary Disease↗

Prognostication in acute myocardial infarction by early echocardiographic estimation of left ventricular ejection fraction. Multivariate statistical comparison with a clinical prognostic index and its components.

The purpose of this study was to define the prognostic value concerning in-hospital, two-month, and one-year mortality of an early echocardiographic estimation of left ventricular ejection fraction, relative to traditional clinical variables and a clinical prognostic index, in an unselected series of 193 patients following acute myocardial infarction. Left ventricular ejection fraction was determined within 72 hours by echocardiographic wall motion analysis within the frame of a nine-segment model. Clinical variables (age, number of acute myocardial infarctions, reinfarction, heart failure, cardiac arrest, ventricular arrhythmias, asystole, supraventricular tachycardia, nodal rhythm) and a calculated, previously published index, based on these variables, were recorded on day five post infarction and predischarge. The Killip class was recorded at the time of echocardiography. All variables were compared by a multivariate approach (Cox regression model). The results showed that left ventricular ejection fraction was the strongest predictor of early and late mortality and increasingly so over the period of observation. Age and maximal Killip class had a modest additional prognostic value, whereas the composite clinical prognostic index had no predictive power when early left ventricular ejection fraction was included in the statistical model.

Adult↗

Comparison of quantitation of left ventricular volume, ejection fraction, and cardiac output in patients with atrial fibrillation by cine magnetic resonance imaging versus invasive measurements.

Currently available invasive and noninvasive techniques for the determination of left ventricular end-diastolic and end-systolic volumes, ejection fraction, and cardiac output are more time-consuming and potentially less accurate in patients with atrial fibrillation (AF) than in those with sinus rhythm. Although magnetic resonance imaging (MRI) can rapidly and accurately measure these variables in patients with sinus rhythm, its ability to do so in subjects with AF is not known. To determine if left ventricular volumes, ejection fraction, and cardiac output can be measured accurately in patients with AF using MRI, 26 subjects (13 women and 13 men, aged 15 to 76 years) in sinus rhythm (n = 13) or AF (n = 13) underwent MRI followed immediately by invasive measurements of these indexes. For those in AF, MRI measurements of left ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and cardiac output correlated well with catheterization measurements (r = 0.90, 0.90, 0.95, 0.85, and 0.90, respectively). In addition, the mean difference between MRI and catheterization measurements was similar in subjects with AF and in those with sinus rhythm. Compared with standard invasive measurements, MRI provides an accurate noninvasive determination of left ventricular volumes, ejection fraction, and cardiac output in patients with AF.

Adolescent↗

[Determination of right ventricular ejection fraction by thermodilution catheter technique during exercise: a comparison with radionuclide ventriculography].

Since the development of a Swan-Ganz Thermodilution Ejection Fraction Catheter, several studies have been published which compare this technique for obtaining right ventricular ejection fraction (RVEFTD) with alternative methods. However, the reliability of RVEFTD measurements under exercise conditions remains undetermined. Therefore, the aim of the present study was to evaluate RVEFTD with the Gated Blood Pool method (RVEFGBP) under exercise conditions. Twenty patients with different cardiac diseases (coronary artery disease, valvular incompetence, cardiomyopathy) underwent right heart catheterization, including RVEFTD and simultaneous RVEFGBP determination at rest and during supine bicycle exercise. Cardiac index at rest-/exercise was 2.9 +/- 0.8/5.7 +/- 2.2 l/min/m2, mean pulmonary artery pressure was 15 +/- 5/25 +/- 8 mmHg, RVEFTD was 38 +/- 6/41 +/- 11% and RVEFRNV was 39 +/- 6/43 +/- 8%. Linear regression analysis showed a significant correlation between RVEFTD and RVEFGBP at rest (r = 0.72, p < or = 0.0005) and during exercise (r = 0.72, p < or = 0.0005). It is concluded that the Thermodilution Ejection Fraction Catheter is a useful device for reliable, repetitive and safe RVEF measurements, not only at rest but also under exercise conditions. This is clinically important, because RVEF, as a sensitive parameter of primary or secondary right ventricular dysfunction, can be determined in the course of standard right heart catheterization.

Adult↗

[Calculation of the ejection fraction from simultaneously recorded systolic intervals and angiography. Comparative study].

Garrard, Weissler and Dodge have reported a close correlation (r = -0,90) between angiographic ejection fractions (EF) and the ratio of left ventricular preejection and ejection periods (PEP/LVET) in patients with left ventricular disease without simultaneous recording equation Y" = 1,25 - 1,25 x where x is the PEP/LVET ratio and Y" the ejection fraction. Using this formula a theoretical EF may be calculated when the PEP/LVET ratio is known. A number of precautions must be taken in measuring systolic time intervals (synchronous recordings, rapid and constant recording speeds of at least 100 mm/s, good quality tracings). Respecting these conditions, close correlations between the theoretical and angiographic EF were obtained. However, discrepancies were observed in some cases and so the relationship was examined with and without simultaneous recordings in 28 patients (19 with coronary artery disease). The equations obtained were Y = 1,2 - 1,51 x and Y = 1,04 - 1,04 x respectively. The correlations in the whole group and in the coronary subgroup were not as good when the recording was not simultaneous (r = -0,78, compared to r = -0,85). The theoretic EF appeared to be "optimised" under these conditions. The "optimisation" increased with increasing values of the PEP/LVET ratio. A downward correction had to be made for abnormally high values (for example for a PEP/LVET of 0,38, the EF had to be corrected by -3,1% and for a value of 0,50 by -10,5%). This was also applicable in the patients with coronary artery disease. Curiously, the equation relating simultaneous EF and PEP/LVET was very close to that obtained by Garrard (Ya = 1, 12 - 1,27 x, ra = -0,80). The theoretical EF calculated from this equation was very close to the angiographic value. However, it was slightly higher or lower in coronary patients with or without myocardial infarction. Garrard's equation would appear to be useful for repeated studies of the ejection fraction in these patients.

Adult↗

Effect of electrophysiological testing on ejection fraction during cardioverter/defibrillator implantation.

To evaluate the effect of repeated induction of ventricular tachycardia or ventricular fibrillation, or both, in patients with poor left ventricular function, we performed intraoperative two-dimensional echocardiography in 6 patients undergoing implantation of the automatic implantable cardioverter/defibrillator. Changes in left ventricular ejection fraction in sinus rhythm were assessed before the first inducible ventricular arrhythmia and after a mean of 6 +/- 1.9 (SD) episodes of ventricular tachycardia or ventricular fibrillation. During the procedure no significant change in mean ejection fraction was observed (28 +/- 14 versus 27 +/- 17%). Only 1 of the 6 patients studied had a change in ejection fraction greater than 3% (a decrease from 20 to 11%). In an overall clinical series of 38 primary implants or generator changes (including electrophysiological testing) in 29 patients, 1 patient recovered after postoperative inotropic support and 1 died of acute postoperative ischemic heart failure. We conclude that ventricular arrhythmias induced during automatic implantable cardioverter/defibrillator implantation have no immediate deleterious effects on ejection fraction in most patients with compromised left ventricular function and without ongoing ischemia.

Aged↗

[The determination of the left ventrical volume curve without background correction and its validation by direct intercomparison with the ejection fractions as determined by biplane laevocardiography (author's transl)].

Background corrections applied on the left ventricular volume curve determined by the "gated blood pool"--method are based on an estimated rather than on a directly measured background. This imposes an uncertainty on the values determined from the volume curve, especially on the ejection fraction. A method which does not require background correction may be applied if all available measurement and evaluation facilities are utilized fully. High temporal and spatial resolution is of fundamental importance, permitting the exact determination of the time-dependent scintigraphic contour variations of the left ventricle during the mechanical action of the heart. A good criterion of the validity of the volume curves with respect to interfering background radiation is the ejection fraction calculated from these curves. The direct intercomparison of 10 ejection fractions obtained by an expanded "gated blood pool"-method, employing cardiac catheterization, immediately before a biplane laevocardiography demonstrated very good agreement. A small systematic underestimation of the ejection fraction by the nuclear method was observed. This understimulation shows that the influence of the true background is small if other interfering count rate contributions or methodical uncertainties are excluded systematically.

Angiography↗

A study on left atrial transport function. Effect of age or left ventricular ejection fraction on left atrial storage fraction.

Left atrial (LA) storage fraction is defined as the ratio of storage volume of the left atrium (LA) during ventricular systole to left ventricular (LV) stroke volume. To test their hypothesis that left atrial (LA) storage fraction is increased to compensate for impaired LV filling in the heart of aged subjects or with impaired LV ejection fraction, the authors studied 33 "normal" subjects and 25 patients with coronary artery disease. LA volume was measured by LA cineangiocardiography, and LV stroke volume and LV ejection fraction were measured by LV cineangiocardiography. To further evaluate the determinants of changes in LA storage fraction, they measured the ratio of LA active release volume to LV stroke volume, and the ratio of LA passive release volume to LV stroke volume. In "normal" subjects, LA storage fraction was increased with age (r = 0.584, P < 0.01). In patients with coronary artery disease, LA storage fraction was increased as LV ejection fraction was decreased (r = -0.525, P < 0.01). In both cases, LA active release fraction was significantly associated with changes in LA storage fraction rather than in LA passive release fraction. They conclude that LA storage fraction may be an important determinant of LV filling mainly through the LA active release fraction.

Adolescent↗

Videodensitometric ejection fractions from intravenous digital subtraction left ventriculograms: correlation with conventional direct contrast and radionuclide ventriculography.

Forty-three patients who had undergone direct-contrast ventriculography were submitted to intravenous digital subtraction ventriculography and first-pass radionuclide ventriculography to compare the left ventricular ejection fractions obtained by each method. Ejection fractions were calculated by the area-length method from the direct contrast ventriculograms, by both area-length and videodensitometric methods from the digital subtraction ventriculograms, and by count densitometry from the radionuclide ventriculograms. Satisfactory correlations were found between values obtained by the late mask resubtracted videodensitometric method and the radionuclide method (r = 0.85) and by the digital ventriculographic area length method and direct-contrast method (r = 0.88). Videodensitometric methods may be an alternative way to estimate left ventricular ejection fractions accurately without reliance on geometric assumptions about the shape of the left ventricular cavity.

Analog-Digital Conversion↗

The effect of right ventricular hypertrophy on left ventricular ejection fraction in pulmonary emphysema.

STUDY OBJECTIVE: The development of right ventricular (RV) hypertrophy in emphysema is accompanied by involvement of the left ventricle (LV) and its systolic function. Our objective was to study the relation between RV hypertrophy and LV ejection fraction in emphysema by means of MRI. PATIENTS: Ten emphysematous patients (FEV1, 0.99+/-0.32 L; FEV1/vital capacity (VC), 0.32+/-0.11 [mean+/-SD]) and 10 age-matched control subjects were included. Exclusion criteria were any history of systemic hypertension, ischemic or valvular heart disease, or episodes of right- and/or left-sided cardiac failure. MEASUREMENTS AND RESULTS: Rapid scout imaging was used to measure RV and LV wall mass, wall thickness, and end-diastolic volume. Stroke volume was derived from the main pulmonary artery flow. RV wall volume, RV wall thickness, and the ratio of RV to LV wall thickness were significantly larger in the patient group than in the control group (p<0.01). Furthermore, patients had significantly lower values of LV ejection fraction (p<0.01) than the control subjects. A flattening or leftward displacement of the ventricular septum during systole was observed. In addition, our study showed an increase of LV ejection fraction proportional with the RV wall thickness (r=0.78, p<0.01) in severely emphysematous patients. CONCLUSION: These data are in support of the hypothesis that flattening of the interventricular septum explains the relatively normal LV ejection fraction in emphysematous patients with severe RV hypertrophy.

Aged↗

A left ventricle model to predict post-revascularization ejection fraction based on cine magnetic resonance images.

The left ventricular ejection fraction (LVEF) is an important clinical indicator of the cardiac function and long-term outcome for patients with coronary artery disease. A biomechanical model of the left ventricle was developed to quantitatively predict post-revascularization LVEF based on noninvasive magnetic resonance imaging. The myocardium was categorized into normal, hibernating, and infarcted regions from the ventricular short-axis images. Assuming that hibernating tissue would potentially regain contractility after revascularization, the expected maximum post-revascularization LVEF was calculated for four patients with chronic left ventricular dysfunction. The predictions were within three ejection fraction points of the follow-up LVEFs. This model may be useful to estimate the outcome and efficacy of revascularization plans.

Heart Ventricles↗

A model of the gastric gland ejection cycle: low ejection fractions require reduction of the glandular dead space.

This paper was inspired by the reported results of authors from Uppsala and Lund that gastric glands in rats rhythmically contract 3-7 cycles per minute and develop luminal pressures more than 10 mmHg. To ensure that pepsinogen is not retained in the acid-rich section of the gland, ejection fractions would need to be more than 50% of the gland volume. We have tried to calculate the ejection fraction of such contractions. Dimensions of human gastric glands were measured on the fresh frozen samples of macroscopically and histologically normal gastric mucosa. In total, 18 specimens (from nine persons) were measured under the microscope. The density of glands was 135 +/- 11 (mean +/- S.D.) glands per mm( 2) of gastric mucosa. A typical gastric gland is a tubular structure 1.2 +/- 0.22 mm long and 0.03-0.05 mm wide. We have used 1 mm for length and 0.03 mm for the gland diameter to calculate that each gland approximates a volume of 707 pl, suggesting that the total glandular volume for 15 million glands reaches 10.6 ml. Further calculations based on one to five contractions per minute on an average and on the total volume of gastric glands of 10 ml showed that only ejection fractions less than 10% deliver daily volumes less than 3 l. The presented model of the gastric gland activity is based on the idea that the low ejection fractions require a reduction of the glandular dead space. The reduced luminal pressure during the gland relaxation might cause backflux of hydrophobic viscoelastic mucus through the gland aperture. Repeated glandular contractions and relaxations would move the mucus all the way to the gland bottom, filling the gland cavity below the neck with an axial semisolid mucous cylinder. This filling would reduce the gland dead space. During contractions, the gland would eject mainly the peripheral, the more liquid part of its content. The decreasing luminal pressure in the relaxing gland would pull the outlet mucus inside, protecting gland apertures from the gastric juice.

Bicarbonates↗

alpha 1-Adrenergic responsiveness during coronary artery bypass surgery: effect of preoperative ejection fraction.

Elevated catecholamines and beta-adrenergic receptor hyporesponsiveness (or desensitization) have been demonstrated in failing human myocardium, but the role of the alpha-adrenergic receptor remains unclear. The authors tested the hypothesis that alpha 1-adrenergic responsiveness decreases in patients with impaired ventricular function undergoing coronary artery revascularization. Impaired ventricular function was defined prospectively by left ventricular ejection fraction less than or equal to 40% (group I, n = 12), and normal ventricular function by ejection fraction greater than 40% (group II, n = 22). Phenylephrine (Phe) pressor dose-response curves were established prior to anesthesia, during fentanyl anesthesia, and during fentanyl anesthesia plus hypothermic cardiopulmonary bypass at the time of aortic cross-clamp (anes + CPB/AXC). Polynomial regression of the Phe dose response curve estimated the Phe dose required to increase mean arterial blood pressure 20%, designated PD20. Although pre-anesthesia PD20 and anes + CPB/AXC PD20 values were not affected by ejection fraction, significant differences in PD20 (P less than 0.05) between groups occurred during fentanyl anesthesia (group I = 2.28 +/- 1.60 micrograms.kg-1, group II 1.57 +/- 0.98 micrograms.kg-1; mean +/- SD). Anes + CPB/AXC was associated with a significant reduction in PD20 in both groups compared with pre-anesthesia (P less than 0.01). Our results suggest impairment of alpha 1-adrenergic responsiveness occurs during fentanyl anesthesia in patients with ejection fractions less than or equal to 40% (evidenced by greater PD20 values). Although this impairment may be due to altered Phe pharmacokinetics, these results also support the possible existance of alpha 1-adrenergic receptor desensitization in this group. Reduction in PD20 during anes + CPB/AXC in all patients points to more powerful effects than fentanyl anesthesia alone; such influencing effects may include hemodilution, hypothermia, elevated plasma catecholamines, exclusion of the pulmonary circulation, or altered Phe pharmacokinetics.

Anesthesia, Intravenous↗

Subphenogroups of acute heart failure with preserved ejection fraction: comprehensive proteomics and pathway analysis.

BACKGROUND: Heterogeneity of heart failure with preserved ejection fraction (HFpEF) results in significant challenges for treatment development. Identifying and characterising distinct HFpEF phenogroups may aid in tailoring therapeutic strategies for these patients. The objective of this study was to assess proteomic patterns of HFpEF phenogroups identified through a machine-learning-based clustering model, with the aim of uncovering specific biological pathways associated with each phenogroup. METHODS: This study represents a post-hoc analysis of the ongoing Prospective mUlticenteR obServational stUdy of patIenTs with Heart Failure with preserved Ejection Fraction (PURSUIT-HFpEF) study, which is a multicentre prospective observational study of hospitalised patients with acute decompensated HFpEF. Of the overall cohort (N=1238), this study analysed 198 patients with HFpEF with available proteomics data. These patients were classified into four phenogroups using the machine-learning-based clustering model. The SomaScan assay V.4.1 was used to measure levels of >7000 plasma proteins, and subsequent pathway analysis was conducted to determine the biological differences among the phenogroups. RESULTS: We identified four distinct phenogroups: Phenogroup 1 ('rhythm trouble'), Phenogroup 2 ('ventricular-arterial uncoupling'), Phenogroup 3 ('low output and systemic congestion') and Phenogroup 4 ('systemic failure'). The proteomics revealed distinct protein expression profiles among the phenogroups, with ribonuclease 4, tax1-binding protein 1, regenerating islet-derived protein 3-gamma and alpha-1-antichymotrypsin being the most significant markers to specific identified phenogroups. Pathway analysis suggested differences in immune response, autonomic activation, cellular homeostasis and tissue repair mechanisms across the phenogroups. CONCLUSIONS: Using a comprehensive plasma proteomics approach, our study identified distinct proteomic profiles of HFpEF phenogroups, which in turn suggest specific underlying biological processes. These profiles suggest the involvement of inflammatory activation, tissue injury and regenerative responses, immune modulation and systemic stress signalling as key components of HFpEF pathophysiology. TRIAL REGISTRATION NUMBER: UMIN-CTR ID: UMIN000021831.

Humans↗

Role of exercise and metabolism in heart failure with normal ejection fraction.

Left ventricular dysfunction associated with metabolic disorders has a number of features that might shed light on the integrity of heart failure with normal ejection fraction. First, although these patients may be dyspneic and have a normal ejection fraction, their diastolic dysfunction is not isolated. Both experimental models and sensitive new parameters in humans have shown abnormal systolic function, even though the less sensitive parameters (such as ejection fraction) become abnormal only with stress. Moreover, the mechanistic contributors to myocardial dysfunction, including structural changes and metabolic influences on the cardiac myocyte, interstitial fibrosis, vascular disease, and altered loading, are likely to influence systolic as much as diastolic function. The responses of systolic and diastolic heart failure to exercise training show analogies, particularly with respect to the importance of peripheral adaptation, as well as a similar training response. Together, these features are more supportive of a continuum of pathophysiology between systolic and diastolic heart failure, rather than the 2 representing discreet phenomena.

Animals↗

The use of the systolic time interval for predicting left ventricular ejection fraction ischemic heart disease.

A large series of 306 patients with ischemic heart disease was studied with automated systolic time intervals and left ventricular ejection fraction as determined by the angiocardiographic method. It was found the pre-ejection period, left ventricular ejection time, delta values, and PEP/LVET ratio all were related to the ejection fraction. However, in all instances the correlation was too low and the scatter of the data was too large to warrant the use of the systolic time intervals for predicting left ventricular function as indicated by the ejection fraction.

Coronary Disease↗

Determination of cardiac ejection fraction and left ventricular volume: contrast-enhanced ultrafast cine MR imaging vs IV digital subtraction ventriculography.

OBJECTIVE: To assess the accuracy of contrast-enhanced, single breath-hold cine MR imaging in the calculation of left ventricular volume and ejection fraction, we compared values obtained by using this method with those obtained by using IV digital subtraction angiography (IV-DSA). SUBJECTS AND METHODS: All patients (n = 28) had conventional cine and contrast-enhanced ultrafast cine MR imaging. For ultrafast cine MR imaging, a phase-rewind gradient-echo (rewind-SMASH) sequence was used: TR, 8 msec (standard excitation and acquisition block of 6 msec with phase rewind pulse of 2 msec); TE, 3.2 msec; a 128 x 96 matrix (pile encode factor, 6; k-space segment, 16); a 200-mm field of view; and one excitation. RESULTS: Values for left ventricular volume and ejection fraction obtained with ultrafast cine MR imaging correlated well with those obtained with IV-DSA (end-diastolic volume, y = 0.986x - 7.79, r = .985; end-systolic volume, y = 0.863x + 0.71, r = .984; ejection fraction, y = 0.877x + 6.44, r = .887). In the calculation of left ventricular volume by the area-length method, manual tracing of the left ventricular cavity was more difficult when the conventional cine method was used than when the enhanced ultrafast cine method was used. CONCLUSION: Our results show that cardiac multiphase study with horizontal long-axis, first-pass, contrast-enhanced, single breath-hold, cine MR imaging is an accurate and highly reproducible method of evaluating left ventricular volume and ejection fraction.

Angiography, Digital Subtraction↗