Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CADAVER”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

The localization of the infrapatellar nerves in the anterior knee region with special emphasis on central third patellar tendon harvest: a dissection study on cadaver and amputated specimens.

The aim of this dissection study on cadaver and amputated specimens was to determine the position of the infrapatellar nerves in the anterior knee region, and to investigate whether it would be possible to harvest the patellar tendon through two small vertical incisions, leaving the infrapatellar nerves undamaged and the major part of the paratenon intact. The infrapatellar nerve did not pass through the area between the apex of the patella and the tibial tubercle in 1 of 60 specimens. The nerve passed through this area as one branch in 15 of 60 specimens, as two branches in 37 of 60, as three in 6 of 60, and as four in 1 of 60 specimens. The distance from the apex of the patella to the infrapatellar nerve or the uppermost branch of the nerve was 30 mm (+/- 27 mm [2 SD]). The distance from the tibial tubercle to the infrapatellar nerve or the lowermost branch of the nerve was 27 mm (+/- 27 mm [2 SD]). In one specimen, the infrapatellar nerve passed 10 mm distal to the tibial tubercle. In 4 of 60 specimens, a branch of the infrapatellar nerve passed just above the tibial tubercle, and in 2 of 60 a branch passed just above the apex of the patella. In 19 of 20 specimens in which the harvesting procedure was performed, the infrapatellar nerve or the nerve branches were undamaged. The length of the undamaged paratenon was 27 mm (+/- 23 mm [2 SD]). This study showed that it was possible to harvest consistent bone-patellar tendon-bone autografts through two vertical 25-mm incisions, leaving the infrapatellar nerve undamaged and the paratenon partially intact in the majority of the cadaver and amputated specimens.

Aged↗

Dorsal intercarpal ligament capsulodesis for scapholunate dissociation: biomechanical analysis in a cadaver model.

The purpose of this study was to evaluate in cadavers a new method for treating scapholunate dissociations, dorsal intercarpal ligament capsulodesis (DILC), and to compare its performance with that of a previously described soft tissue reconstruction, Blatt capsulodesis (BC). A cadaver model was used to simulate normal and abnormal wrist motions. The positions of the scaphoid and lunate and their changes with wrist motion and ligament condition were recorded using biplanar radiographs taken posteroanteriorly and laterally. The scapholunate gap was measured on the posteroanterior radiographs and the scapholunate angle was measured on the lateral view radiographs. Following scapholunate interosseous ligament sectioning, a diastasis developed between the scaphoid and lunate that was maximum in the clenched fist position 2.1 +/- 0.33 mm (mean +/- SEM) with the ligament intact versus 8.0 +/- 1.74 mm after the ligament was sectioned. Dorsal intercarpal ligament capsulodesis reduced gap formation more than BC, including when the specimens were in the clenched fist position: increased gap versus intact specimens equals 1.0 mm for DILC versus 3.7 mm for BC. The differences in diastasis were statistically significant between BC and DILC when the wrist was in extension, radial deviation, and clenched fist positions. After the scapholunate interosseous ligament was divided, the scaphoid flexed relative to the lunate. Both capsulodeses improved scapholunate alignment and there was a trend for DILC to correct the scapholunate angle more than BC. The results demonstrate that DILC is an attractive alternative to BC ex vivo. Because DILC does not tether the scaphoid to the distal radius, as BC does, improved wrist motion, especially flexion, might be possible in vivo. The use of DILC in the treatment of scapholunate dissociation warrants further investigation and clinical trials.

Adult↗

Ultrasonography for the evaluation of forearm interosseous membrane disruption in a cadaver model.

Recognition of interosseous membrane disruption associated with radial head injury and Essex-Lopresti injury is important, especially if radial head excision is contemplated. Because a widely accepted method to diagnose interosseous membrane disruption does not exist, we evaluated the accuracy of ultrasonography to diagnose this injury in a cadaver model. Nine pairs of cadaver forearms were randomized into 2 groups. The central third of the interosseous membrane of forearms of group 1 was cut, whereas it was visualized but not cut in group 2. A dynamic ultrasound examination was performed to determine interosseous membrane integrity, and static images were made. The static images were evaluated by 2 other radiologists and interpretations were recorded. One radiologist incorrectly interpreted 1 pair of forearms; the other 2 radiologists were 100% accurate. The accuracy of ultrasonography in detecting interosseous injuries was 96% with our methods.

Biomechanical Phenomena↗

Anatomic placement of the Herbert-Whipple screw in scaphoid fractures: a cadaver study.

An anthropometric cadaver study was performed to determine the optimal placement of a Herbert-Whipple screw in the scaphoid. Twenty pairs of cadaver wrists were examined and anthropometric analysis of the scaphoids using plain radiography, computed tomography, and en bloc resection was performed. Scaphoid vascularity was evaluated using India ink injection. Radiographic and actual measurements of height and width confirmed symmetry in paired scaphoids. Anatomic evaluation defined a safe zone for screw placement. K-wire placement defined the extent of this zone. The entry point of this zone was found by moving dorsally and distally 15% of the lateral radiographic length of the contralateral scaphoid from the volar aspect of the scaphoid tuberosity. Moving 10% of this same length from the membranous central portion of the scapholunate ligament defined the target site. Computed tomography confirmed proper position of the screw to maximize bony purchase and avoid articular penetration while maintaining dorsal vascular integrity.

Anthropometry↗

Optimizing the use of donated cadaver livers: analysis and policy development to increase the application of split-liver transplantation.

The American Society of Transplant Surgeons and the American Society of Transplantation jointly sponsored a conference in Crystal City, Virginia, on March 28th and 29th, 2001, to explore mechanisms for maximizing the cadaver-organ donor pool. Participants from transplantation medicine, surgery, organ procurement organizations, the general public, and government convened to address expanding utilization of each organ type. The committee assigned to review liver organ utilization identified multiple practices that could expand the potential donor pool including non-heart beating donors, marginal grafts, efficient allocation of cadaver organs, and wider application of split-liver transplantation. This article details the data reviewed by the liver committee and their recommendations on policy development for the expanded application of split-liver transplantation.

Cadaver↗

Comparison of trochlear block recession and trochlear wedge recession for canine patellar luxation using a cadaver model.

OBJECTIVE: To compare trochlear block recession (TBR) to trochlear wedge recession (TWR) with regards to patellar depth (percentage of patellar volume under the trochlear ridges), patellar articular contact, percentage of recessed trochlear surface area, and resistance to patellar luxation. STUDY DESIGN: In vitro computed tomography (CT) and biomechanical evaluation using a cadaver model. SAMPLE POPULATION: Twelve normal, large-breed canine cadavers. METHODS: Bilateral pelvic limb specimens with intact stifle joints were mounted on a positioning device. The femoral trochlear ridges were reduced to provide a standard shallow trochlea. TBR or TWR was performed to a standard depth randomly on paired specimens. CT and biomechanical evaluations were performed pre- and postoperatively in both an extended (148 degrees ) and flexed (113 degrees ) stifle position. CT images were digitized and measurements made using an image-analysis software program. Biomechanical testing consisted of applying 40 degrees of internal tibial rotation and documenting patellar luxation. RESULTS: The change in trochlear depth (depth of recession) was not significantly different between groups. In the extended stifle position (patella in the proximal trochlea), patellar depth and patellar articular contact with the recessed trochlea were significantly greater after TBR compared with TWR. The percentage of recessed trochlear surface area was significantly greater after TBR compared with TWR. In the extended position, a smaller percentage of the patellae luxated within 40 degrees of internal tibial rotation after TBR compared with TWR. CONCLUSIONS: TBR increases proximal patellar depth, increases patellar articular contact with the recessed proximal trochlea, recesses a larger percentage of trochlear surface area, and results in a greater resistance to patellar luxation in an extended position as compared with TWR. CLINICAL RELEVANCE: TBR may help limit the development of stifle DJD in dogs treated for canine patellar luxation.

Animals↗

Effects of superior check desmotomy on flexor tendon and suspensory ligament strain in equine cadaver limbs.

OBJECTIVE: To measure the effects of transection of the accessory ligament of the superficial digital flexor (SDF) muscle (superior check desmotomy) on flexor tendon and suspensory ligament (SL) strain in vitro. STUDY DESIGN: In vitro experimental biomechanical investigation. ANIMALS USED: Ten equine cadaver forelimbs. METHODS: The effects of superior check desmotomy were determined using equine cadaver forelimbs secured in a servocontrolled hydraulic testing machine. Strain sensors were used to measure strain on the superficial and deep digital flexor tendons and SL, and a goniometer was used to measure joint angles when the limb was loaded at 890 N and 3,115 N before desmotomy, and at 3,115 N after desmotomy. RESULTS: Superior check desmotomy was associated with significantly increased strains on the SDF tendon and SL, and significant alterations in the angles of the metacarpophalangeal and carpal joints. CONCLUSIONS: The superior check ligament has an important role in maintaining joint angles and load distribution in the forelimb. Lengthening of the SDF musculotendinous unit after superior check desmotomy may be associated with increased strain on the SL. CLINICAL RELEVANCE: Transection of the accessory ligament of the SDF muscle may predispose horses to SL desmitis postoperatively.

Animals↗

Internal mammary perforators: a cadaver study.

Microsurgeons currently employ the internal mammary artery and vein as recipient vessels for microvascular reconstruction of the breast with increasing frequency. Recent reports have demonstrated that the perforating branches of the internal mammary artery and vein can also be used as recipient vessels. The purpose of the following cadaver study was to determine the location and diameter of these internal mammary perforators and whether they are suitable as recipient vessels. Ten fresh cadavers were obtained for this project. Using a micrometer under loupe magnification, bilateral measurements were taken of the perforators from the first five interspaces. The largest arterial perforator averaged 1.74 mm in diameter and the largest venous perforator averaged 1.78 mm in diameter. The largest perforators were most commonly found in the second interspace. Based on the results of this study, the internal mammary perforators appear to have suitable diameter for microvascular anastomosis and should be considered.

Aged↗

[Spiral CT in arytenoid cartilage dislocation: the optimization of the study parameters with a cadaver phantom and its clinical evaluation].

PURPOSE: To evaluate an optimal scan protocol in a cadaver phantom and its clinical assessment in 40 patients. MATERIALS AND METHODS: In a cadaver larynx phantom helical CT (HiSpeed Advantage; GE, Milwaukee, Wis) was performed with increasing collimation (1-10 mm) and pitch (1.0-3.0). 40 patients with an immobile vocal cord were randomly assigned to undergo CT with a certain protocol. RESULTS: Best resolution was obtained with a collimation of 1 mm and pitch 1. The pitch could be increased up to 2 without losing information. With a collimation of 3 mm and higher, anatomical details were missed. In the patient studies a combination of 1 mm collimation with a pitch of 2.0 showed less motion artifacts than a pitch of 1.0. CONCLUSION: The quality of CT imaging of the arytenoid cartilage depends greatly on the scanning parameters, the compliance of the patients and the mineralisation of the cartilage. For clinical assessment a collimation of 1 mm with a pitch of 2 is recommended. The increase pitch has the advantage of shorter acquisition times and decreased radiation exposure.

Artifacts↗

Endoscopy of spinal cord and posterior fossa by a lumbar percutaneous approach: endoscopic anatomy in cadavers.

Endoscopy has a long history and is used extensively today following recent technical improvements. Endoscopy has been used in neurosurgery to examine ventricles, cisterns, and intra-arteries. In this study, we evaluated the possibility of endoscopic examination and treatment in the narrow confines of the subarachnoid space of the spine and the posterior fossa. Endoscopes with external diameters of 0.5, 1.4, and 2.2 mm were used. While the first two endoscopes had rigid tips, the 2.2-mm endoscope had a directable tip. Each endoscope was inserted percutaneously in the lumbar region in five cadavers and was advanced cranially into the posterior fossa under endoscopic monitoring. Arteries, veins and nerve roots upon the surface of the spinal cord could be distinguished readily with all endoscopes. All endoscopes could be inserted under direct observation, avoiding these vessels and nerve roots. Further rostral advancement of the endoscope permitted visualization of the upper spinal cord, cisterna magna at the foramen magnum, and the fourth ventricle. The lower aspect of the cerebellum, the foramen of Magendie, and the cerebral aqueduct could be observed from below. When the endoscope was advanced ventrolaterally, the vertebral artery and lower cranial nerves were observed. From this preliminary cadaver study, endoscopy via lumbar puncture appeared useful for inspection of structures surrounding the spinal cord and posterior fossa, and for some simple treatments.

Cadaver↗

Immunologic factors determining survival of cadaver-kidney transplants. The effect of HLA serotyping, cytotoxic antibodies and blood transfusions on graft survival.

We assessed immunologic factors determining graft survival in 510 recipients of primary cadaver allografts at one center. The degree of HLA match grade did not directly affect graft survival (54 per cent in no-antigen match, and 42 per cent in three-antigen match, at two years). There was no correlation between the HLA match grade and the degree of stimulation of the mixed lymphocyte culture. Patients receiving more than five blood transfusions had a significantly better graft survival than nontransfused recipients (52 versus 23 per cent, respectively, at two years, P less than 0.001). The beneficial effect of transfusions was noted whether or not lymphocytotoxic antibodies were produced, provided adequate screening was performed before transplantation. Transfusions did not alter the degree of stimulation in the mixed lymphocyte culture. More liberal use of transfusions and frequent screening for cytotoxic antibodies would probably result in more effective cadaver-kidney transplantation.

Blood Transfusion↗

The incidence of basal sphenoid bony bridges in dried crania and cadavers: their anthropological and clinical relevance.

The aim of this study was to investigate the incidence of the pterygospinous and pterygoalar bony bridges and the variations in these bony bridges among Anatolians. A total of 452 adult dry skulls (258 males and 194 females) of the Anatolian population were investigated for both the pterygospinous and the pterygoalar bony bridges. In 80 of the 452 dry skulls (37 male and 43 female), it was possible to inspect the cranial cavity. In these skulls, sellar and sphenopetrous bridges were also investigated. In addition to this, the mandibular nerve of 9 fixed cadavers was carefully dissected and the distribution of its branches was determined on both sides. Complete pterygospinous osseous bridges were found in 5.5% of the samples and complete pterygoalar bridges in 4.9%. In the dry skulls with removed calvaria, complete sellar osseous bridges were found on both sides in 34.2% of specimens, complete pterygospinous bridges in 8.8% and complete pterygoalar bridges in 7.5%. No complete sphenopetrous bridges were found. In the cadaveric study, nerve entrapment due to a pterygoalar ligament on the left side was found in one cadaver. Such variations should be kept in mind in clinical complaints such as mandibular neuralgia, especially during chewing.

Anthropology, Physical↗

Permeability and retention studies of (-)epicatechin gel formulations in human cadaver skin.

(-)Epicatechin (EC) is a major antioxidant component of grape seed extract which has become increasingly popular in topical skin preparations. This study assessed the following: (1) the permeability through cellulose membranes of EC in three different gel formulations (Carbopol 940, Klucel, and Ultrez 10); (2) the effect of three different antioxidants (butylated hydroxytoluene (BHT), alpha-tocopherol (VE), and ascorbic acid (AA)) on the stability and penetration properties of EC; and (3) the permeability and retention of EC in Ultrez 10 gels, supplemented with BHT or VE, on human cadaver skin. Permeability studies through cellulose membranes showed that different gelling agents do not significantly affect the permeability of EC (n = 7/gel; p > 0.05). BHT and VE have antioxidant properties superior to AA (p < 0.05) and preserve 100% of the initial content of EC for 28 days. Permeation studies on cadaver human skin, following application of two anhydrous gel formulations (0.5% EC in Ultrez 10 containing BHT or VE), showed that EC was not detectable in the receiving solution. However, the EC amount in viable skin increased with time, indicating that EC penetrated and was retained in the upper part of the skin for approximately 1% and 3% of the dose for the formulations containing BHT and VE, respectively.

Acrylic Resins↗

An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study.

BACKGROUND: Image guidance provides additional anatomic information to the surgeon, which may allow more accurate insertion of spinal implants. Imprecise placement of anterior thoracic screws places the spinal cord and paraspinal structures at risk for injury. Image guidance may afford a safety benefit to patients when anterior thoracic screws are required in the setting of spinal stabilization after trauma. OBJECTIVES: To compare the accuracy of anterior thoracic screw placement using standard fluoroscopy, computer-assisted fluoroscopic image guidance, Iso-C3D image guidance, and electromagnetic fluoroscopic image guidance. STUDY DESIGN: A surgical simulation study in human cadaver spine specimens. METHODS: After an open thoracotomy approach, anterior thoracic screws were placed by experienced spine surgeons using 4 different image-guided techniques in 4 human cadaver thoracic spines. Screws were placed in the 9th, 10th, and 11th thoracic vertebrae of each specimen. The specimens were then examined with thin-cut computed tomography (CT) scans, and with sagittal and coronal reconstructions. Measurements included the distance of the screw from the spinal canal, the angle of the screw path in relation to a perpendicular to a line that bisects the spinous process, and the angle of screw divergence from the superior endplate. RESULTS: There was no evidence of spinal canal penetrance with any of the image-guided techniques used to place anterior thoracic vertebral body screws. Screws inserted with standard fluoroscopy tended to aim anterolaterally by 18 degrees. The image-guidance systems allowed more accurate placement of anterior thoracic screws in the transverse plane compared with standard fluoroscopy. There was no statistically significant difference in coronal plane screw angulation (angle of divergence with the superior endplate) between any of the imaging methods. CONCLUSIONS: Spinal image-guidance systems may allow spine surgeons to place anterior thoracic screws more precisely, particularly in the axial plane. The improved accuracy of spinal implant insertion could ultimately provide a benefit to patient safety, especially in the setting of malaligned vertebral bodies after trauma.

Aged↗

Therapeutic ultrasound: temperature increase at different depths by different modes in a human cadaver.

A specific increase in temperature is necessary to achieve a temperature-mediated therapeutic impact by ultrasound in rehabilitation. In order to obtain a physical basis for a definite temperature rise at a certain depths in the human body a human cadaver study in situ was conducted. A set of 16 experiments was carried out with an ultrasound frequency of 1 and 3 MHz. For each frequency the pulsed and continuous mode of energy delivery were compared at a variable intensity of 0.5, 1.0, 1.5 and 2.0 W/cm2. The ultrasonic energy was delivered in direct contact to the cadaver at the posterior crural compartment of the leg in a static manner. Temperature was monitored with a 1-minute interval during an insonation of 10 minutes. Results revealed that theoretical physical predictions concerning tissue heating by therapeutic ultrasound could not always be consolidated and that thermal therapeutic effects for deeper conditions are not obvious to be achieved by ultrasonic therapy.

Blood Circulation↗

A strategy to achieve donor-specific hyporesponsiveness in cadaver renal allograft recipients by donor haematopoietic stem cell transplantation into the thymus and periphery.

INTRODUCTION: We designed a prospective, randomized clinical trial to evaluate the immune response to thymic and peripheral infusions of donor haematopoietic stem cells (HSCs) to create tolerance in recipients of cadaver renal allografts. METHOD: We divided 24 patients into two equal groups. For group A, 350 ml of unfractionated bone marrow (BM) was aspirated from the anterior iliac crests of donor cadavers. A 2 ml aliquot of concentrated marrow was infused into the thymus of the subject and 100 ml into the BM before surgery; the remaining 250 ml was infused peripherally post-transplantation. The mean nucleated cell count inoculated into the thymus was 3.3 x 10(4) cells/cm(3) and into the periphery 8.6 x 10(7) cells/kg body weight. Group B (controls) underwent renal transplantation directly. Recipients were lymphocytotoxicity cross-match negative in both groups. Group A received low dose prednisolone and cyclosporin; controls also received azathioprine. RESULTS: Over a mean follow-up of 703 days for both groups, group A had significantly better graft function with minimum acute rejection episodes or cytomegalovirus (CMV) infections, a mean serum creatinine (SCr) of 1.23 mg/dl and no graft or patient loss. Group B, with a mean SCr of 2.19 mg/dl had three patients with single acute rejection episodes, two of whom died following uncontrolled rejection-associated infections. The third patient maintained an SCr of 2.5 mg%. Actuarial graft survival was 87.5% in controls at the end of 2 years compared with group A with 100% graft survival at the end of 2 years. CONCLUSION: This novel approach of introducing unfractionated HSCs into the thymus and periphery to create tolerance is safe and efficacious and gives significantly better graft function, minimum acute rejection and no CMV disease with monotherapy.

Adult↗

Optimal methods for shoulder tendon palpation: a cadaver study.

BACKGROUND AND PURPOSE: Physical therapists often must either palpate tendons of the shoulder or, as part of treatment, apply forces to those tendons. Many methods have been suggested for minimizing the amount of soft tissue that overlies these tendons, but no data have been presented to justify the use of any approach. The purpose of this study was to evaluate methods described in the literature by use of cadaver models. SUBJECTS: Twenty-four shoulders from 12 cadavers of individuals aged 55 to 92 years were dissected. METHODS: Shoulders were placed in the positions described in the literature, and the positions in which the tendons were maximally exposed (ie, had the least overlying tissue) were noted. RESULTS: Positions were found in which tendons were maximally exposed. CONCLUSION AND DISCUSSION. Positions described in the literature for optimizing the exposure of shoulder tendons are not always optimal, and palpation and treatment may be improved by using positions determined by research such as those suggested in this report.

Aged↗

Interpretation of accelerants in blood of cadavers found in the wreckage after fire.

Accelerants in the blood of 73 cadavers found in wreckage after fire were analyzed by gas chromatography (GC) and a combination of gas chromatography-mass spectrometry (GC-MS) to decide whether accelerants containing petroleum components had been used and whether the cadavers had been exposed to fire before or after death. In 16 of 26 cases in which accelerants were used to start a fire before death, accelerants were detected in the blood. In 7 cases in which accelerants were used to start a fire, the victims were determined to have been exposed to the vapor of accelerants after death because no accelerants were detected in the blood, no soot was found in the airways, and carboxyhemoglobin (COHb) concentrations were not higher than those found in smokers. In 9 of 34 cases in which accelerants were suspected to have been used to start a fire before death, accelerants were detected in the blood. When soot is not detectable by the unaided eye in the airways of a victim found in debris of a fire in which the use of accelerants is suspected, or the COHb concentration in the blood is no higher than in a smoker, analysis of accelerants in the blood seems to be helpful in determining the cause of death and whether inflammable were used.

Adolescent↗