Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bromates”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Semiconductor-mediated photocatalysed degradation of two selected azo dye derivatives, amaranth and bismarck brown in aqueous suspension.

Semiconductor-mediated photocatalysed degradation of two selected azo dye derivatives such as amaranth (1) and bismarck brown (2) has been investigated in aqueous suspension by monitoring the change in substrate concentration employing UV spectroscopic analysis technique as a function of irradiation time. The degradation was studied under different conditions such as types of TiO(2), pH, substrate concentration, catalyst concentration, and in the presence of electron acceptors such as hydrogen peroxide (H(2)O(2)), potassium bromate (KBrO(3)) and ammonium persulphate (NH(4))(2)S(2)O(8) besides air. The degradation rates were found to be strongly influenced by all the above parameters. The photocatalyst Degussa P25 showed comparatively highest photocatalytic activity. The dye derivative, bismarck brown (2) was found to degrade faster than amaranth dye (1).

Amaranth Dye↗

Temperature dependent polarized Raman spectra of nonaaqualanthanoid (Pr) single crystal.

Polarized Raman spectral changes with respect to temperature were investigated for Pr(BrO3)3.9H2O single crystals. FTIR spectra of hydrated and deuterated analogues were also recorded and analysed. Temperature dependent Raman spectral variation have been explained with the help of the thermograms recorded for the crystal. Factor group analysis could propose the appearance of BrO3 ions at sites corresponding to C3v (4) and D3h (2). Analysis of the vibrational bands at room temperature confirms a distorted C3v symmetry for the BrO3 ion in the crystal. From the vibrations of water molecules, hydrogen bonds of varying strengths have also been identified in the crystal. The appearance upsilon1 mode of BrO3- anion at lower wavenumber region is attributed to the attachment of hydrogen atoms to the BrO3- anion. At high temperatures, structural rearrangement is taking place for both H2O molecule and BrO3 ions leading to the loss of water molecules and structural reorientation of bromate ions causing phase transition of the crystal at the temperature of 447 K.

Crystallography, X-Ray↗

Risk analysis of drinking water microbial contamination versus disinfection by-products (DBPs).

Managing the provision of safe drinking water has a renewed focus in light of the new World Health Organization (WHO) water safety plans. Risk analysis is a necessary component to assist in selecting priority hazards and identifying hazardous scenarios, be they qualitative to quantitative assessments. For any approach, acute diarrhoeal pathogens are often the higher risk issue for municipal water supplies, no matter how health burden is assessed. Furthermore, potential sequellae (myocarditis, diabetes, reactive arthritis and cancers) only further increase the potential health burden of pathogens; despite the enormous uncertainties in determining pathogen exposures and chemical dose-responses within respective microbial and chemical analyses. These interpretations are currently being improved by Bayesian and bootstrapping approaches to estimate parameters for stochastic assessments. A case example, covering the health benefits of ozonation for Cryptosporidium inactivation versus potential cancers from bromate exposures, illustrated the higher risks from a pathogen than one of the most likely disinfection by-products (DBPs). Such analyses help justify the industries long-held view of the benefits of multiple barriers to hazards and that microbial contamination of water supplies pose a clear public health risk when treatment is inadequate. Therefore, efforts to reduce potential health risks from DBP must not compromise pathogen control, despite socio-political issues.

Carcinogens↗

Bayesian analysis of physiologically based toxicokinetic and toxicodynamic models.

Physiologically based toxicokinetic (PBTK) and toxicodynamic (TD) models of bromate in animals and humans would improve our ability to accurately estimate the toxic doses in humans based on available animal studies. These mathematical models are often highly parameterized and must be calibrated in order for the model predictions of internal dose to adequately fit the experimentally measured doses. Highly parameterized models are difficult to calibrate and it is difficult to obtain accurate estimates of uncertainty or variability in model parameters with commonly used frequentist calibration methods, such as maximum likelihood estimation (MLE) or least squared error approaches. The Bayesian approach called Markov chain Monte Carlo (MCMC) analysis can be used to successfully calibrate these complex models. Prior knowledge about the biological system and associated model parameters is easily incorporated in this approach in the form of prior parameter distributions, and the distributions are refined or updated using experimental data to generate posterior distributions of parameter estimates. The goal of this paper is to give the non-mathematician a brief description of the Bayesian approach and Markov chain Monte Carlo analysis, how this technique is used in risk assessment, and the issues associated with this approach.

Animals↗

Data considerations for regulation of water contaminants.

There are several pieces of legislation based on human health assessment that set the framework for U.S. EPA's regulation of water contaminants, such as bromate. The Safe Drinking Water Act, for example, specifies that the best available science be used in support of regulation of drinking water contaminants, and highlights that regulations must provide protection to sensitive human populations. Recent EPA guidance, including the 2005 Cancer Guidelines, emphasize analyzing data, and using defaults only in the absence of adequate data. This represents a major shift from the former practice of invoking default methodologies or values unless it was judged that there were sufficient data to depart from them. The Guidelines further present a framework for assessing data in order to determine if a mode of action (MOA) can be established, based on a modification of the Bradford-Hill criteria for causality. A similar approach is used by the International Programme on Chemical Safety (IPCS). To illustrate the application of the framework for evaluating animal tumors, three case studies are considered here. In the first example (chloroform carcinogenicity), sufficient data exist to identify the MOA in animals, and the data are used to illustrate the evaluation of the plausibility of the animal MOA in humans, taking into account toxicokinetics and toxicodynamics. In this case, the MOA was judged to be relevant to humans, and was used to determine the approach for the cancer quantitation. In the second example (naphthalene inhalation carcinogenicity), the key question is whether the weight of evidence (WOE) is sufficient to establish the MOA in animals. Atrazine-induced mammary tumors form the final example, illustrating the reasoning used to determine that the tumor MOA in animals was not considered relevant to humans; atrazine is therefore considered not likely to be a human carcinogen.

Animals↗

Evaluation of the sensitivity of three sublethal cytotoxicity assays in human HepG2 cell line using water contaminants.

The in vitro toxicological index IC50 (the millimolar concentration of compound which inhibits response assay by 50% compared to the solvent control) of 11 water contaminants (acrylamide, atrazine, B[a]P, BPA, 2,4-DAT, 17-alphaEE, H(2)O(2), 4-OP, sodium bromate, sodium chlorate, sodium nitrate) was evaluated on the human hepatoma (HepG2) cells using three short-term bioassays related to their morbidity status [radiometric RNA synthesis assay (RNA), luminometric ATP assay (ATP), fluorometric Alamar blue assay (AB)]. Among all substances, we were not able to determine atrazine IC50 value whatever the test used. Furthermore, B[a]P was not cytotoxic in the ATP and AB assays. Statistical analysis revealed a correlation between the IC50 values obtained in the three assays. Except with 4-OP, RNA assay was always inhibited at lower concentrations than those required in the other assays, suggesting that this assay is a very sensitive indicator of the presence of toxic compounds. ATP and AB assays responded to a similar pattern. Due to its higher sensitivity and its reliability, RNA synthesis assay using HepG2 cell line provides the most suitable tool for the screening of water contaminants.

Adenosine Triphosphate↗

Oxidative degradation of N-nitrosodimethylamine by conventional ozonation and the advanced oxidation process ozone/hydrogen peroxide.

This study investigates the oxidative degradation of N-nitrosodimethylamine (NDMA), a probable human carcinogen, by conventional ozonation and the advanced oxidation process ozone/hydrogen peroxide (AOP O(3)/H(2)O(2)). The rate constants of reactions of NDMA with ozone and hydroxyl radical ((*)OH) were determined to be 0.052+/-0.0016M(-1)s(-1) and (4.5+/-0.21)x10(8)M(-1)s(-1), respectively. The experiments performed with buffered deionized water varying solution pH and employing H(2)O(2) and HCO(3)(-) clearly showed that the reaction with (*)OH dominates the NDMA oxidation during ozonation. Conventional ozonation with up to 160 microM (=7.7 mgL(-1)) ozone led to less than 25% NDMA oxidation in natural waters. The AOP O(3)/H(2)O(2) required 160-320 microM ozone ([O(3)](0)/[H(2)O(2)](0)=2:1) to achieve 50-75% NDMA oxidation. However, multiple injections of ozone of the same overall dose somewhat improved the oxidant utilization efficiency by minimizing (*)OH scavenging contribution of oxidants. Methylamine (MA) was found to be a major amino product from NDMA oxidation initiated by (*)OH. The mechanism of NDMA oxidation to MA is discussed based on the results obtained in this study and the previous literature. Bromate formation may be the limiting factor for NDMA oxidation during ozonation and ozone-based AOPs in bromide-containing waters.

Dimethylnitrosamine↗

Protein S-glutathionylation correlates to selective stress gene expression and cytoprotection.

During situations of oxidative stress phenotypic adaptation to altered redox state is achieved by changes in expression of selected genes. The mechanisms regulating this may involve reversible S-glutathionylation of cellular proteins. In this study we compared and contrasted changes in gene expression patterns in human type II lung epithelial A549 cells and human endothelial ECV304 cells in correlation to glutathione oxidation and the formation of glutathione-protein mixed disulphides, after exposure to subtoxic levels of hydrogen peroxide, formed in the medium by addition of glucose oxidase, or the thiol oxidant diamide. Both the number of specific mRNAs and their levels of induction were grossly correlated to the degree of S-glutathionylation of cellular protein. Thus, diamide induced the expression of a variety of protein and DNA chaperones and transcriptional regulators, particularly in ECV304 cells. On the other hand, the peroxide failed to induce many of these species, in association with only minimal disturbances to glutathione homeostasis. The induction of the chaperone responses at the level of mRNA was clearly shown to translate into a more resistant morphological phenotype in response to both heat shock and oxidative stress induced by the DNA-damaging pro-oxidant potassium bromate.

Cell Line↗

Nitric oxide (NO): in vivo electrochemical monitoring in the dorsal horn of the spinal cord of the rat.

NO synthase (NOS) is largely distributed in the superficial and deep laminae of the dorsal horn as well as in dorsal root ganglion cells. It has been proposed that nitric oxide (NO) participates in the transmission of sustained, and possibly brief, nociceptive, inputs at the spinal level. The aim of this study was to check the ability of in vivo electrochemical monitoring of NO within the dorsal horn of the lumbar spinal cord (L3-L4 level) of chloral hydrate anesthetized or decerebrated spinalized rats. 30 microm diameter and 450 microm length treated carbon fiber electrodes coated with nickel(II) tetrakis (3-methoxy-4-hydroxy-phenyl) porphyrine and NafionR, and associated with differential normal pulse voltammetry, gave a peak of oxidation current around 650 mV (vs. Ag-AgCl) in vitro in NO solutions between 0.125 and 1.25 microM. In vivo, a 650 mV peak appeared which was stable (recording interval 2 min) for up to 3 h (+/-6%). Comparison between in vitro calibration and in vivo voltammograms gave an estimated in vivo extracellular concentration of 0.50 microM. In vivo, peaks decreased by 95% at 90 min and for up to 3 h after an i.p. injection of 100 mg/kg of the NOS inhibitor (NOSI) L-arginine-p-nitroanilide (L-ANA). At the same dose i.p., N(G)-nitro-L-arginine methyl ester (L-NAME) was almost ineffective after 90 min in animals paralyzed with pancuronium bromate or gallamine trethiodide. However, in non-curarized decerebrated spinalized animals, L-NAME depressed the voltammograms by 36% at 90 min. S-Ethylthiourea (80 mg/kg i.p.), also decreased the voltammograms by 45% at 140 min, and finally, 7-nitroindazole (7-NI, 90 mg/kg i.p), induced a important decrease of the 650 mV peak (23% of control) at 120 min. These results are in agreement with biochemical data showing the decrease of NOS activity within the lumbar spinal cord by L-NAME (45% of control at 90 min) and 7-NI (20% of control at 90 min). The NO donor hydroxylamine (30 mg/kg i.p.) significantly increased the peaks (140% at 90 min), and sodium nitroprusside (SNP, 20 mM) when directly superfused upon the spinal cord (200-300 microl min(-1)) induced a large increase in the peak (300% at 90 min). Moreover, SNP 60 min after L-ANA, or 90 min after L-NAME, rapidly restored the 650 mV peak up to control values. These results demonstrate the validity of electrochemical monitoring of NO within the dorsal horn of the spinal cord. The in vivo electrochemical detection of NO is in progress to study the implication of this messenger in the transmission of nociceptive messages at the spinal level.

Anesthesia, General↗

Effect of temperature on retention and selectivity in ion chromatography of anions.

The temperature dependence of retention of a wide range of inorganic anions is studied on two commercially available ion exchangers (Dionex AS11 and AS14 columns). Anion retention exhibited both exothermic and endothermic behavior, such that varying the temperature from ambient to 60 degrees C produced selectivity changes. The anions displayed three groupings of temperature dependence: weakly retained singly charged anions (e.g., iodate, bromate, nitrite, bromide and nitrate); multiply charged anions (sulfate, oxalate, phosphate and thiosulfate); and strongly retained singly charged anions (iodide, thiocyanate and perchlorate). Temperature was ineffective at changing the selectivity of retention between anions of the same grouping. However, significant selectivity changes, including elution order reversal, could be achieved between anions from different groupings.

Anions↗

Fast separation of UV absorbing anions using ion-interaction chromatography.

Ion-interaction chromatography on a short (30 x 4.6 mm) 3 microm ODS column has been investigated with the aim of developing fast chromatographic separations of selected inorganic anions. Tetrabutylammonium chloride (TBA-Cl) was used as the ion-interaction reagent in mobile phases that also contained up to 20% methanol. Separations of simple test mixtures of up to eight UV absorbing anions illustrated how excellent efficiencies (>50,000 plates/m) could be obtained under optimized conditions. The use of an optimised mobile phase containing 20 mM TBA-Cl and 20% methanol resulted in the baseline separation of five important anions (iodate, bromate, nitrite, bromide and nitrate) in a separation window of just 28 s, with a shortest total analysis time of 50 s. The method was briefly applied to the rapid analysis of nitrite and nitrate in both a drinking water and a river water sample with a view to future on-line monitoring.

Anions↗

Rapid and direct determination of iodide in seawater by electrostatic ion chromatography.

An electrostatic ion chromatographic (IC) method for rapid and direct determination of iodide in seawater is reported. Separation was achieved using a reversed-phase ODS packed column (250x4.6 mm I.D.) modified by coating with Zwittergent-3-14 micelles, with an eluent comprising an aqueous solution containing 0.2 mM NaClO4 and 0.3 mM Zwittergent-3-14 and using UV detection at 210 nm. Samples prepared by dissolving NaIO3, NaNO2, NaBr, NaBrO3, NaNO3, NaI, and NaSCN in artificial or real seawaters were analyzed using this IC system. Nitrite, iodate, bromide, bromate, and nitrate showed very little or no retention, while iodide and thiocyanate were well separated, being eluted within 6 and 16 min, respectively. The detection limit for iodide obtained by injecting 400 microL of sample was 0.011 microM (S/N = 3), and the precision values obtained by analyzing samples containing 0.1 or 0.3 microM iodide in real seawater samples were 2.3% RSD and 1.2% RSD, respectively. Direct determination of iodide in real seawater samples was possible using this proposed IC system.

Chromatography, Liquid↗

Fast ion chromatography of common inorganic anions on a short ODS column permanently coated with didodecyldimethylammonium bromide.

Fast ion-exchange chromatography has been developed and applied to the separation of common inorganic anions. Using a didodecyldimethylammonium bromide (DDAB) coated short (30 mm x 4.6 mm) ODS analytical column (3-microm particle size) and a 5 mM phthalate eluent (pH 7.5) the isocratic separation of nine common anions in 160 s was possible, with the first seven anions, including phosphate, chloride and sulphate, separated within 65 s. Detection was achieved using indirect UV at 279 nm. The high capacity, highly hydrophobic ion-exchange coating demonstrated excellent stability over time, even at elevated temperatures (45 degrees C) and exhibited unusual selectivity for common anions (retention order=fluoride, carbonate, phosphate, chloride, bromate, nitrite, sulphate, bromide and nitrate). The developed chromatography was successfully applied to the rapid analysis of river water and seawater samples.

Anions↗

Analysis of oxyhalides in water by ion chromatography-ionspray mass spectrometry.

A sensitive method for analyzing chlorite, chlorate, bromate and iodate in water by ion chromatography (IC) coupled with ionspray tandem mass spectrometry (IS-MS-MS) has been developed. Prior to analysis, samples were subjected to off-line sample clean-up with Ba, Ag and H-form resins to remove sulfate, chloride and hydrogencarbonate, respectively. Oxyhalides in the purified samples were concentrated and separated on a short, high-performance anion-exchange column. An eluent consisting of ammonium nitrate in methanol-water (9:1, v/v) was found to be suitable for separating the analytes, while providing enhanced detector sensitivity. The coupling of IC with IS-MS-MS allows for the identification of the four oxyhalides mentioned above in a single run with very high specificity and sensitivity.

Drinking↗

Critical comparison of retention models for the optimisation of the separation of anions in ion chromatography. II. Suppressed anion chromatography using carbonate eluents.

Seven theoretical retention models, namely the linear solvent strength model (using the dominant equilibrium approach and competing ion effective charge approach), the dual eluent species model, the Kuwamoto model, the extended dual eluent species model, the multiple species eluent/analyte model and the empirical end-points model, were used to describe the retention behaviour of anions in suppressed ion chromatography (IC). An extensive set of experimental retention data was gathered for 24 anions (fluoride, formate, bromate, chloride, hexanesulfonate, bromide, chlorate, nitrate, iodide, thiocyanate, perchlorate, sulfite, succinate, sulfate, tartrate, selenate, oxalate, tungstate, phthalate, molybdate, chromate, thiosulfate and phosphate) on a Dionex AS4A-SC column using carbonate eluents of varying concentration and HCO3-:CO3(2-) ratios. Statistical comparison of the predicted and experimentally obtained retention factors showed that the performance of the theoretical models improved with the complexity of the model. However the empirical model (in which a linear relationship is assumed between the logarithm of retention factor and the logarithm of eluent strength, but the slope is determined empirically) gave the most consistent performance across the widest range of anions. The empirical end-points model was also shown to be the most satisfactory model due to its low knowledge requirements and easy solution. Compared with non-suppressed IC (see Part I), the retention behaviour in suppressed IC was found to be easier to model by all retention models.

Anions↗

Analysis of low-molecular-mass inorganic and organic anions by ion chromatography-atmospheric pressure ionization mass spectrometry.

Different nonvolatile mobile phases have been tested for the combination of ion-exchange chromatography combined with mass spectrometric detection of anions and organic acids. Buffer systems based on carbonate, sulfate, oxalate and citrate as the eluting species have been used. Among these, citrate proved to be the most versatile eluent allowing the separation of anions with absolute detection limits between 0.4 and 0.7 ng and of organic acids with detection limits between 0.4 and 4 ng in the non-suppressed mode. In the suppressed eluent mode iodate, bromate and chlorate could be separated using sodium carbonate as the mobile phase resulting in detection limits of 50 pg. The method was applied to the analysis of water samples containing oxyhalides originating from ozonization. Additionally, organic acids were separated by chromatographic separation techniques like reversed-phase, ion-pair or ion-exclusion chromatography and the compatibility with mass spectrometry was investigated with special respect to sensitivity of this detection mode.

Anions↗

Determination of chlorate at low microgram/l levels by ion-chromatography with postcolumn reaction.

A new method for the determination of low concentrations of chlorate in natural waters is described. Chlorate is analyzed by ion-chromatography followed by an osmate-catalyzed postcolumn reaction of chlorate with iodide and UV-detection of triiodide. The new osmate catalysis allows to carry out the oxidation of iodide by chlorate at pH 3 instead of 6 M HCl for the uncatalyzed reaction. A detection limit of 5 nM (0.4 microgram/l) chlorate is achieved. The method also allows the simultaneous determination of chlorite, bromate, and nitrite at the low microgram/l level.

Calibration↗

By-products formation during drinking water disinfection: a tool to assess disinfection efficiency?

In drinking water treatment, the inactivation of microorganisms increases with increasing disinfectant exposure (product of concentration and contact time, CT). Also, the formation of undesired (toxic) disinfection by-products increases with CT. The present study proposes a new concept that uses this undesired side effect of chemical water disinfection for a fast and reliable test of treatment efficiency. In laboratory systems, bromate formation during ozonation and the formation of trihalomethanes during chlorination were used to calculate the disinfectant exposure, which is a measure for the achieved degree of disinfection.

Animals↗