Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Measurement and characterization of angiotensin peptides in plasma.

We report a method for the extraction of angiotensin peptides from plasma with a mixture of acetone, 1 mol/L HCl, and water (40/1/5 by vol). The method is highly reproducible for the measurement of angiotensin I and angiotensin II in small sample volumes, with analytical recoveries of about 80% for both peptides. We investigated the influence of sample handling and found a standard procedure for blood collection, plasma preparation, and extraction was essential. The method was used to measure angiotensin I and II in rat and human plasma. In rat plasma, the mean (+/- SEM) concentrations of angiotensin I and angiotensin II were determined to be 67 (+/- 8) and 14 (+/- 1) pmol/L (n = 10), respectively. Neither angiotensin I nor angiotensin II was detectable 24 h after bilateral nephrectomy. Acute oral administration of the converting-enzyme inhibitor ramipril caused a significant increase of angiotensin I from 85 (+/- 6) to 257 (+/- 33) pmol/L (n = 10; P less than 0.001) and a significant decrease of angiotensin II from 12 (+/- 1) to 7 (+/- 0.4) pmol/L in rat plasma (n = 9; P less than 0.001). In human plasma, angiotensin I and angiotensin II values of 21 (+/- 1) and 6.6 (+/- 0.5) pmol/L (n = 10) were found. A single oral dose of the diuretic furosemide increased angiotensin I significantly from 21 (+/- 1) to 32 (+/- 1.7) pmol/L (n = 5); P less than 0.001), whereas angiotensin II remained unchanged, 6.6 (+/- 0.5) vs 6.4 (+/- 0.4) pmol/L (n = 5). Extracted peptides could be identified as [IIe5]-angiotensin I and [IIe5]-angiotensin II by HPLC in combination with specific radioimmunoassays for angiotensin I and angiotensin II.

Adult↗

Improved gas chromatography methods for micro-volume analysis of haloacetic acids in water and biological matrices.

A fast headspace solid-phase microextraction gas chromatography method for micro-volume (0.1 mL) samples was optimized for the analysis of haloacetic acids (HAAs) in aqueous and biological samples. It includes liquid-liquid microextraction (LLME), derivatization of the acids to their methyl esters using sulfuric acid and methanol after evaporation, followed by headspace solid-phase microextraction with gas chromatography and electron capture detection (SPME-GC-ECD). The derivatization procedure was optimized to achieve maximum sensitivity using the following conditions: esterification for 20 min at 80 degrees C in 10 microL methanol, 10 microL sulfuric acid and 0.1 g anhydrous sodium sulfate. Multi-point standard addition method was used to determine the effect of the sample matrix by comparing with internal standard method. It was shown that the effect of the matrix for urine and blood samples in this method is insignificant. The method detection limits are in the range of 1 microg L(-1) for most of the HAAs, except for monobromoacetic acid (MBAA) (3 microg L(-1)) and for monochloroacetic acid (MCAA) (16 microg L(-1)). The optimized procedure was applied to the analysis of HAAs in water, urine and blood samples. All nine HAAs can be separated in < 13 min for biological samples and < 7 min for drinking water samples, with total sample preparation and analysis time < 50 min. Analytical uncertainty can increase dramatically as the sample volume decreases; however, similar precision was observed with our method using 0.1 mL samples as with a standard method using 40 mL samples.

Acetic Acid↗

Determination of pentachlorophenol (PCP) in waste wood--method comparison by a collaborative trial.

Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground "real life" starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.5-20 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of approximately 19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation.

Chemistry Techniques, Analytical↗

A MALDI sample preparation method suitable for insoluble polymers

Polyamides are insoluble or poorly soluble in common organic solvents, which makes normal sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry very difficult. An new analytical protocol for MALDI analysis of polyamides or other insoluble samples is described. It consists of pressing a pellet from a solid mixture of the polymer and a matrix, both in the form of finely ground powder. This sample preparation is compared with the common dried droplet sample preparation method and found to perform much better, both in terms of robustness against variation of experimental parameters and high-mass capability.

Journal Article↗

Validated liquid chromatographic method for the determination of bexarotene in human plasma.

A new liquid chromatographic method is described for the determination of the anti-tumour agent bexarotene in human plasma over the range 0.500-1500 ng/ml, using 1 ml of sample. Sample preparation consists of liberating the analyte from plasma lipids by adding acetonitrile, followed by acidification of the plasma and liquid extraction using a mixture of isoamyl alcohol and pentane or hexane. Separation and quantitation are performed by reversed-phase column liquid chromatography with fluorescence detection. Parameters affecting the performance of these steps are discussed. Validation results on linearity, selectivity, accuracy, precision, recovery and stability are shown, as well as the application of the method to samples from clinical trials.

Bexarotene↗

Sensitive trace enrichment of environmental andiandrogen vinclozolin from natural waters and sediment samples using hollow-fiber liquid-phase microextraction.

The presence of vinclozolin in the environment as far as the endocrine disruption effects in biota are concerned has raised interest in the environmental fate of this compound. In this respect, the present study attempts to investigate the feasibility of applying a novel quantitative method, liquid-phase microextraction (LPME), so as to determine this environmental andiandrogen in environmental samples such as water and sediment samples. The technique involved the use of a small amount (3 microL) of organic solvent impregnated in a hollow fiber membrane, which was attached to the needle of a conventional GC syringe. The extracted samples were analyzed by gas chromatography coupled with electron-capture detection. Experimental LPME conditions such as extraction solvent, stirring rate, content of NaCl and pH were tested. Once LPME was optimized, the performance of the proposed technique was evaluated for the determination of vinclozolin in different types of natural water samples. The recovery of spiked water samples was from 80 to 99%. The procedure was adequate for quantification of vinclozolin in waters at levels of 0.010 to 50 microg/L (r> 0.994) with a detection limit of 0.001 microg/L (S/N= 3). Natural sediment samples from the Aliakmonas River area (Macedonia, Greece) spiked with the target andiandrogen compound were liquid-liquid extracted and analyzed by the methodology developed in this work. No significant interferences from the samples matrix were noticed, indicating that the reported methodology is an innovative tactic for sample preparation in sediment analysis, with a considerable improvement in the achieved detection limits. The results demonstrated that apart from analyte enrichment, the proposed LPME procedure also serves as clean-up method and could be successfully performed to determine trace amounts of vinclozolin in water and sediment samples.

Androgen Antagonists↗

Determination of 3-quinuclidinyl benzilate (QNB) and its major metabolites in urine by isotope dilution gas chromatography/mass spectrometry.

In response to the scheduled destruction of U.S. military stockpiles of the hallucinogenic agent 3-quinuclidinyl benzilate (QNB), a specific confirmatory test for human exposure to QNB was developed. The amount of the parent compound in the urine as well as the two major metabolites, 3-quinuclidinol (Q) and benzilic acid (BA), was determined because the relationship between QNB dose and levels of QNB and its metabolites in human urine is not known. QNB was determined in urine samples spiked at a target level of 0.5 ng/mL, and the metabolites BA and Q were determined at a target level of 5 ng/mL. The method uses solid-phase extraction to isolate each analyte from the urine and isotope dilution gas chromatography/mass spectrometry for quantitation. Each analyte is converted to its trimethylsilyl derivative for analysis. The analytical method was tested on eight different urine samples spiked with known amounts of the analytes near the target levels, at 10 times the target levels, and blank (unspiked) urine samples. The variabilities in the method are for the most part evenly distributed between three imprecision categories: GC/MS measurement, sample preparation, and the urine samples. The total imprecision (1 standard deviation) of a single measurement is about 15% of the value for each analyte.

Gas Chromatography-Mass Spectrometry↗

Monitoring of oxidation steps of ascorbic acid redox reaction by kinetics-sensitive voltcoulometry in unsupported and supported aqueous solutions and real samples.

Aqueous solutions of ascorbic acid in unsupported and supported aqueous solutions and real samples were studied by the kinetics-sensitive double-step voltcoulommetric method with the aim to contribute to a better understanding of its behavior in biological systems. The data obtained from measurements made on analytes prepared in the laboratory, as well as those made on real samples (some commercial orange drinks, flash of the fresh fruits) point to the redox reaction of L-ascorbic acid (L-AH2) being very sensitive to both the presence of dissolved gaseous species (O2, CO2) and the ionic strenght in the analyte. Either the dissolved gaseous species, or the higher ionic strength caused by both the presence of supporting electrolyte and increased total concentration of ascorbic acid, respectively, give birth to the degradation of L-AH2. Naturally, the highest percentage of L-AH2 was spotted in fresh fruit.

Ascorbic Acid↗

Flow-injection chemiluminescence determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids.

A novel, rapid and sensitive analytical method is described for determination of ofloxacin and levofloxacin by enhanced chemiluminescence (CL) with flow-injection sampling. The method is based on the CL reaction of the Ce(IV)-Na2S2O4-ofloxacin/levofloxacin-H2SO2 system. The enhanced CL mechanism was developed and the optimum conditions for CL emission were investigated. The CL intensity was correlated linearly (r = 0.9988) with the concentration of ofloxacin (or levofloxacin) in the range of 1.0 x 10(-8) - 1.0 x 10(-7) g ml(-1) and 1.0 x 10(-7) - 6.0 x 10(-6) g ml(-1). The detection limit (S/N = 3) is 7 x 10(-9) g ml(-1). The relative standard derivation (RSD, n = 11) is 2.0% for ofloxacin at 4 x 10(-7) g ml(-1) and for levofloxacin at 6 x 10(-7) g ml(-1). This method has been successfully applied for the determination of ofloxacin and levofloxacin in pharmaceutical preparations and biological fluids with satisfactory results.

Anti-Infective Agents, Urinary↗

Preparation and characterization of nitrilotriacetic-acid-terminated self-assembled monolayers on gold surfaces for matrix-assisted laser desorption ionization-time of flight-mass spectrometry analysis of proteins and peptides.

On-target affinity capture, enrichment and purification of biomolecules improve detection of specific analytes from complex biological samples in matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) analysis. In this paper, we report a simple method for preparation of a self-assembled nitrilotriacetic acid (NTA) monolayer on gold surface which can be used as a MALDI-TOF-MS sample target specifically for recombinant oligohistidine-tagged proteins/peptides and phosphorylated peptides. The NTA functional groups are immobilized to the gold surface via the linkage of 1,8-octanedithiol which forms a self-assembled monolayer on gold. Characterization by X-ray photoelectron spectroscopy and MALDI analysis of the modified surface are described. The chemically modified surface shows strong affinity toward the analytes of interest, which allows effective removal of the common interferences, e.g. salts and detergents, and therefore leads to improved signal/noise ratio and detection limit. The use of the modified surface simplifies the sample preparation for MALDI analysis of these targeted analytes.

Gold↗

Capillary isoelectric focusing.

Capillary isoelectric focusing (CIEF) provides excellent resolution of proteins with the advantage that separations are carried out in a capillary format with on-tube detection and automated analysis. Recent advances in the technique provide improved resolution, reproducibility and reliability. This review summarizes improvements in sample preparation, capillary selection, and focusing and zone mobilization procedures which have helped CIEF become a more robust analytical method. New applications are reviewed, in particular the use of CIEF in analysis of biopharmaceutical products.

Electrophoresis, Capillary↗

Development of a reference material for residues of chlorfluazuron and fluazuron in beef fat ACSL CRM 3Part I. Preparation, homogeneity and stabilit.

A beef fat sample was prepared and tested as candidate reference material for the pesticides chlorfluazuron (CFZ) and fluazuron (FZN). An analytical method employing HPLC with UV absorbance detection was developed for homogeneity and stability testing. The material consisted of beef fat spiked with acetone solutions of CFZ and FZN to achieve concentrations close to 1.0 mg/kg for each compound. The coefficients of variation of 7 analyses carried out to test between-jar homogeneity were 1.8% and 2.3% for FZN and CFZ, respectively. No instability of CFZ was detected over a three month period. The candidate reference material was found to be suitable for certification by interlaboratory testing.

Journal Article↗

Capillary gas chromatographic-mass spectrometric determination of buspirone in plasma.

Methods for determining buspirone plus a deuterated analogue and for buspirone alone in plasma samples are described. Analytes are prepared from plasma by liquid extraction into n-butyl chloride and subsequent back-extraction clean-up steps. Instrumental analysis involves selected-ion monitoring gas chromatography-mass spectrometry with fused-silica capillary chromatography. Quantification is in the range 0.05-10 ng/ml with acceptable accuracy and precision.

Anti-Anxiety Agents↗

Automated high-performance liquid chromatographic method for determination of furosemide in dog plasma.

An automated high-performance liquid chromatographic method for the determination of the diuretic drug furosemide has been established. Dog plasma was injected directly into a two-column system with a BSA-ODS (ODS column coated with bovine serum albumin) precolumn and a C18 analytical column for the separation of furosemide. The two columns were automatically switched. Furosemide remained trapped on the precolumn while proteins were eluted to waste. After column switching, furosemide was washed onto the analytical column and analysed without interference. The greatest advantage of the method is its easy performance without manual sample preparation; it requires no extraction or deproteinization. The method allows determination of 0.1-10 micrograms/ml of furosemide with accuracy and precision comparable with previously reported values. The coefficients of variation obtained from replicate measurements of 1 microgram/ml and 5 micrograms/ml samples were 1.65% and 2.40%, respectively. This method was used to measure the plasma levels of furosemide in beagle dogs to whom the drugs was administered, as a reference, in a toxicological study.

Animals↗

The impact of hemolysis on Ortho-Clinical Diagnostic's ECi and Roche's elecsys immunoassay systems.

BACKGROUND: Hemolysis is regularly encountered in clinical specimens and often interferes with a variety of laboratory test methods. Although not widely recognized, immunoassays based on nonisotopic detection systems can also be affected by hemolysis. For this reason, we investigated the effect of differing amounts of hemolysis across a range of values for several immunoassays on the Ortho-Clinical Diagnostics ECi and Roche Elecsys platforms. METHODS: Hemolysate was prepared from whole blood and spiked at varying concentrations into pooled patient serum samples for different analytes. RESULTS: Out of the 21 analytes tested, six (28.6%) exhibited significant increases or decreases in measured concentrations with increasing amounts of hemolysis. CONCLUSIONS: Although immunoassays are generally thought to be impervious to hemolysis interference, hemolysis can interfere in immunoassay testing platforms. For these reasons, we recommend that laboratories conduct hemolysis interference studies for all laboratory test protocols.

Blood Specimen Collection↗

Occurrence of ionophore antibiotics in water and sediments of a mixed-landscape watershed.

Analytical methods for quantifying three ionophore antibiotics, monensin, salinomycin, and narasin, were developed for water and sediment matrices. Sample preparation was based on solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS) was used to separate and detect the compounds. Recoveries ranged from 83% to 117% for water and from 51% to 105% for sediment in three different concentrations with less than 10% of relative standard deviation. The statistical detection limit was 0.001-0.003 microg/L for water and 0.4-3.6 microg/kg for sediment. Ionophore antibiotics are only used to treat coccidiostats for broilers or turkeys, and to increase growth and feed efficiency for beef and dairy cattle. Since they are not used for human purposes, these compounds can act as markers for the transport of animal pharmaceuticals to the watershed. The occurrence of three ionophore compounds was determined at five sampling sites along the Cache la Poudre River in Northern Colorado representing pristine, urban, and agriculture landscapes. Statistical analysis demonstrates that the measured concentration was significantly different among sampling sites in different sampling events for both water and sediment. In addition, significant differences were observed among different sampling times at each sampling site. Furthermore, all three ionophores were found in the sediments at much higher concentrations than in water indicating the importance of this matrix when determining environmental impacts.

Agrochemicals↗

A method for quantitating the intracellular metabolism of AZT amino acid phosphoramidate pronucleotides by capillary high-performance liquid chromatography-electrospray ionization mass spectrometry.

A methodology has been developed for the analysis of the intracellular metabolism of 3'-azido-3'-deoxythymidine (AZT) amino acid phosphoramidates utilizing reverse-phase high-performance liquid chromatography interfaced with negative ion electrospray ionization mass spectrometry (LC/ESI(-) -MS). The presented work demonstrates the potential of capillary LC/MS and LC/MS/MS to identify and quantitate the cellular uptake and metabolism of nucleoside phosphoramidate. Significant intracellular amounts of D- and L-phenylalanine methyl ester or D- and L-tryptophan methyl ester AZT phosphoramidates were observed for human T-lymphoblastoid leukemia (CEM) cells incubated for 2 and 4 h with the prodrugs. AZT-MP was the primary metabolite observed for human T-lymphoblastoid leukemia (CEM) cells. In this paper, the details of using LC/MS to analyze AZT amino acid phosphoramidates in biological samples are discussed. LC/MS is an efficient method for analyzing multiple samples containing several analytes in a short period of time. The method also provides high selectivity and sensitivity, and requires minimal sample preparation. This approach should be broadly applicable for the analysis of the intracellular metabolism of nucleoside prodrugs and pronucleotides.

Amides↗

Laboratory and analytical method performance of lead measurements in paint chips, soils, and dusts.

The National Lead Laboratory Accreditation Program (NLLAP) recognizes laboratories capable of analyzing lead in paints, soils, and dusts. NLLAP requires successful participation in the Environmental Lead Proficiency Analytical Testing (ELPAT) program. For paint chip analyses, laboratory-to-laboratory variability is about 10% relative standard deviation (RSD) for lead levels near 0.5%, the HUD definition of lead-based paint. For soil analyses, RSDs are about 9 to 10% near relevant federal soil standards and 16% near the lowest state bare soil standard that currently exists. For dust wipe analyses, RSDs range from 10 to 16% for lead levels near relevant HUD standards. Of participating laboratories, 92 to 93% consistently meet ELPAT performance limits. A variety of analytical methods gives similar results. No conclusive significant differences were found among most frequently used hotplate and microwave sample preparation techniques. In addition, several participating laboratories have successfully used ultrasonic extraction methods, a method suitable for use at abatement sites. The three most frequently used instrumental techniques, flame atomic absorption (FAA), inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and graphite furnace atomic absorption show no statistically significant differences in ability to meet ELPAT performance limits. However, small statistically significant biases between these methods sometimes occur. The magnitude of biases is less than 5% of the corresponding laboratory mean near relevant federal standards except for lead levels near the lowest HUD lead wipe standard, where biases can be as high as 8%. Other instrumental methods that have been used successfully include ICP-mass spectroscopy, direct current plasma-atomic emission spectroscopy, dithizone spectrophotometry, and anodic stripping voltametry.

Accreditation↗