Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AEROSOLS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Aerosol lidar intercomparison in the framework of the EARLINET project. 1. Instruments.

In the framework of the European Aerosol Research Lidar Network to Establish an Aerosol Climatology (EARLINET), 19 aerosol lidar systems from 11 European countries were compared. Aerosol extinction or backscatter coefficient profiles were measured by at least two systems for each comparison. Aerosol extinction coefficients were derived from Raman lidar measurements in the UV (351 or 355 nm), and aerosol backscatter profiles were calculated from pure elastic backscatter measurements at 351 or 355, 532, or 1064 nm. The results were compared for height ranges with high and low aerosol content. Some systems were additionally compared with sunphotometers and starphotometers. Predefined maximum deviations were used for quality control of the results. Lidar systems with results outside those limits could not meet the quality assurance criterion. The algorithms for deriving aerosol backscatter profiles from elastic lidar measurements were tested separately, and the results are described in Part 2 of this series of papers [Appl. Opt. 43, 977-989 (2004)]. In the end, all systems were quality assured, although some had to be modified to improve their performance. Typical deviations between aerosol backscatter profiles were 10% in the planetary boundary layer and 0.1 x 10(-6) m(-1) sr(-1) in the free troposphere.

Journal Article↗

Radiative transfer model for aerosols in infrared wavelengths for passive remote sensing applications.

A comprehensive analytical radiative transfer model for isothermal aerosols and vapors for passive infrared remote sensing applications (ground-based and airborne sensors) has been developed. The theoretical model illustrates the qualitative difference between an aerosol cloud and a chemical vapor cloud. The model is based on two and two/four stream approximations and includes thermal emission-absorption by the aerosols; scattering of diffused sky radiances incident from all sides on the aerosols (downwelling, upwelling, left, and right); and scattering of aerosol thermal emission. The model uses moderate resolution transmittance ambient atmospheric radiances as boundary conditions and provides analytical expressions for the information on the aerosol cloud that is contained in remote sensing measurements by using thermal contrasts between the aerosols and diffused sky radiances. Simulated measurements of a ground-based sensor viewing Bacillus subtilis var. niger bioaerosols and kaolin aerosols are given and discussed to illustrate the differences between a vapor-only model (i.e., only emission-absorption effects) and a complete model that adds aerosol scattering effects.

Journal Article↗

Facemasks and facial deposition of aerosols.

Passage of aerosol around or through a facemask can result in deposition on the face and in the eyes. The present study quantified facial and eye deposition in a model simulating drug delivery to a young child. Aerosol delivery and facial deposition of radiolabeled saline test aerosols were studied in vitro with filters and a gamma camera. A child's face facsimile, attached to a piston pump, was used to simulate the patient receiving aerosol therapy. A filter placed in the oropharynx of the face facsimile measured aerosol delivery (inhaled mass). Seven commercially available facemasks in combination with three jet nebulizers were studied for aerosol delivery to the "patient" as well as for deposition on the face and in the eyes. Inhaled mass varied from 2.24-5.96% of nebulizer charge (drug placed in the nebulizer). Facial deposition varied from 0.44-2.34% of nebulizer charge, with eye deposition at 0.09-1.78%. All facemasks leaked aerosol, with significant facial and eye deposition approaching in magnitude delivery to the lung. Factors affecting facial and eye deposition include the interactive design characteristics of the facemask and nebulizer, as well as the aerodynamic properties of the aerosol.

Aerosols↗

Trocar site recurrence is unlikely to result from aerosolization of tumor cells.

PURPOSE: This study was undertaken to investigate the ability of a high-pressure CO2 environment to aerosolize tumor cells in both in vitro and in vivo models. (An aerosol is defined as a stable gaseous suspension of insoluble particles). Also, this study was designed to determine if rapid desufflation is capable of transporting fluid laden with tumor cells. METHODS: The four in vitro aerosol experiments were performed in an 18.9-1 plastic vessel fitted with two 7-mm ports and a compliant latex balloon affixed to the top. After CO2 insufflation, the vessel was desufflated through a sterile soluset containing 25 ml of culture media that was subsequently emptied into a culture dish, incubated for two weeks, and periodically assessed for growth. At the bottom of the vessel, one of the following was placed: Study 1 and 2, a suspension of B16 melanoma or colon 26 tumor cells in liquid culture media; Study 3, colon 26 cells in saline solution; Study 4, several pieces of solid colon 26 tumor. In Studies 1 to 3, cell preparations were subjected to the following high-pressure CO2 conditions (pneumo): 1) static pneumo of 15 and 30 mmHg (10 minute dwell); 2) a continuous flow (CF) of CO2 (1O l) while maintaining a pressure of 15 or 30 mmHg in the vessel. In Study 4, only the 30 mmHg static and CF conditions were tested. Between 6 and 12 determinations were performed for each condition and cell preparation. In vivo aerosol experiments consisted of Spraque Dawley rats that received intraperitoneal injections of 10-5 B16 cells in 0.1 ml of liquid media. Two laparoscopic ports were placed in the abdomen, one each for insufflation and desufflation. Study groups were: 1, static CO2 pneumo of 15 mmHg; 2 and 3, continuous CO2 flow (10 l) at a stable pneumo pressure of 5 and 10 mmHg. Desufflation was performed via the same collecting device and handled in an identical manner to the in vitro experiments described above. The in vitro balloon experiment was designed to investigate the ability of desufflation to transport fluid-containing tumor cells; latex balloon model was used. To prevent complete loss of volume on desufflation, a wire coil was placed inside the balloon. Twenty ml of media containing 20 x 10(-6) B16 cells was placed in the bottom of the balloon. The balloon was insufflated with 1 to 2 l of gas. There were three study groups that differed in the degree to which the cell suspension was agitated before desufflation. Study conditions were as follows: 1) no agitation; 2) moderate agitation to coat the lower walls and coil; 3) maximum agitation to coat the entire balloon. To verify the viability of tumor cells, at the end of each in vitro and in vivo study, a sample of tumor cells or peritoneal washing was incubated in sterile media. These samples served as positive controls. RESULTS: In vitro aerosol studies consisted of the following. At the end of two weeks of incubation, no tumor growth was noted in any of the 124 test dishes. The 14 control samples all demonstrated tumor growth. In vivo aerosol studies consisted of the following. Zero of 18 experimental dishes grew tumor. All three peritoneal washing samples demonstrated growth. In vitro balloon studies consisted of the following. Zero of 12 test dishes in Groups 1 and 2 demonstrated growth, whereas five of six dishes did so in Group 3 (maximally agitated before desufflation). Again, positive controls all grew tumor cells. SUMMARY: We were unable to demonstrate aerosol formation in any of the in vitro and in vivo studies performed. In the balloon experiment, desufflation-related transport of tumor cells was demonstrated but only when the entire balloon surface was coated with the tumor cell suspension before desufflation. CONCLUSION: Aerosols of tumor cells are not likely to form. Free intraperitoneal tumor cells are most likely found in liquid suspension. Desufflation is a potential means of transport of cell-laden fluid.

Aerosols↗

The temporal and spatial variations of acid aerosols in the geothermal area of metropolitan Taipei, Taiwan.

This study involved sampling over 1 year of data on exposure to acid aerosols in the geothermal area of metropolitan Taipei. The temporal and spatial variations of the concentrations of acid aerosols were assessed by sampling at three sites: A, B, and C. Results indicate that the SO2 concentrations lead the concentrations of other acid aerosols at site C because two active fumaroles surround this site. The mean SO2 concentrations at sites A, B, and C were 2.4, 2.4, and 6.2 ppb. Previous studies have found that H2S levels were highest at site C. However, the SO4(-2) and H+ concentrations among the three sites were similar. The mean aerosol SO4(-2) concentrations were 7.0, 5.7, and 5.7 microg m(-3) at sites A, B, and C, respectively; their H+ concentrations were 5.5, 4.2, and 5.4 nmol m(-3). No seasonal variations are observed for most of the acid aerosols in the geothermal area except that the types of hot spring affect the SO4(-2) concentration nearby. The different seasonal fluctuation among the sites reflect the determinant of SO4(-2) emission from different geothermal sources. Sulfur-rich aerosols and some SO2 emitted from geothermal sources are obvious. The predominance of nitrogen-containing gases (sum of NO2 + HNO2 + HNO3) over SO2 indicates the importance of the anthropogenic origin of emissions. The effect of multiple exposures to sulfur-rich aerosol (including H2S, SO2, and SO4(-2)), H+, and nitrogen-containing aerosols on the health of nearby residents warrants concern.

Acids↗

Deposition of aqueous aerosol of technetium-99m diethylene triamine penta-acetic acid generated and delivered by a novel system (AERx) in healthy subjects.

Deposition of technetium-99m diethylene triamine penta-acetic acid aqueous radioaerosols generated by a novel aerosol delivery system (AERx) was studied in six healthy subjects using both planar and single-photon emission tomography (SPET) imaging. AERx is a microprocessor-controlled, bolus inhalation device that is actuated at pre-programmed values of inspiratory flow rate and volume. The aims of the study were to determine the effects of posture and inhaled volume upon deposition of the aerosol in the lungs. Each subject inhaled the radioaerosol in two positions (supine vs sitting) and with two inspiratory manoeuvres [vital capacity (VC) vs "fixed volume" of 1 l above functional residual capacity]. Simultaneous transmission-emission planar and tomographic images were acquired. The results showed diffuse deposition of the aerosol in the lung. Neither the breathing manoeuvre nor the posture was found to affect the distribution of the aerosol as measured by the ratio of the activity (counts per pixel) in the peripheral:central (penetration index, PI) or in the apex:base regions of the planar lung images (P>0.1). A small, albeit statistically significant, difference in PI (P<0.03) was found between VC and fixed volume sitting manoeuvres with SPET only. The PI values themselves indicate that the radioaerosol was well distributed in the lung, with the periphery having 45%-64% of the activity of the central region. Superposition of transmission SPET lung outline on emission SPET visually confirmed the excellent peripheral deposition of the aerosol. The AERx system showed high efficiency of delivery, with approximately 50% of the extruded dose in the device depositing in the lung. The uniformity of radioactivity distributed throughout the lung is attributed to the fine particle size (mass median aerodynamic diameter of 2 microm) of the aerosol and the electronic control of aerosol inhalation by the device. In conclusion, the AERx system can be ideal for diffuse aerosol deposition of therapeutic or diagnostic agents and is largely unaffected by inhaled volume and posture. The efficiency of the device device can limit the total radiation exposure of patients and staff administering the radioaerosols, and can make it suitable for delivery of expensive drugs.

Adult↗

Synergistic interaction between nitrogen dioxide and respirable aerosols of sulfuric acid or sodium chloride on rat lungs.

We examined interactions in rats between NO2 gas and respirable aerosols of sulfuric acid (H2SO4) or sodium chloride (NaCl). Rats were exposed for 1, 3, or 7 days to 5 ppm of NO2 gas, alone or in combination with 1 mg/m3 of H2SO4 or NaCl aerosols. The apparent rate of collagen synthesis by lung minces was measured after 7 days of exposure, and the protein content of whole lung lavage fluid was measured after 1 or 3 days of exposure. Responses from rats exposed to 5 ppm of NO2 alone were significantly different from controls by these assays. A synergistic interaction was demonstrated between 5 ppm of NO2 and 1 mg/m3 of either H2SO4 or NaCl aerosol as evaluated by measurement of the rate of lung collagen synthesis. A synergistic interaction was also demonstrated by the criterion of increased protein content of lung lavage fluid in rats exposed to 5 ppm of NO2 and 1 mg/m3 of H2SO4 aerosol after 1 day of exposure and between 5 ppm of NO2 and 1 mg/m3 of NaCl aerosol after 3 days of exposure. These observations with 5 ppm of NO2 alone and in combination with 1 mg/m3 of NaCl aerosol support the hypothesis that formation of nitrosyl chloride may contribute to a synergistic interaction between NO2 gas and NaCl aerosol. These results suggest that, in general, combinations of oxidant gases with respirable acidic aerosols or with acidogenic gases will demonstrate interactive effects on rat lungs. Such a hypothesis is testable and makes specific predictions about effects of inhalation of pollutant mixtures.

Acid Phosphatase↗

Effects of fine and ultrafine sulfuric acid aerosols in guinea pigs: alterations in alveolar macrophage function and intracellular pH.

Acidic sulfate is the most toxicologically important sulfur oxide which exists in the ambient air. To determine if particle size influences toxic effects of sulfuric acid, we investigated the effects of sulfuric acid aerosols of two different sizes on biochemical and cellular parameters of bronchoalveolar lavage fluid from exposed guinea pigs. Guinea pigs were exposed to fine (mass median diameter, 0.3 micron), and ultrafine (mass median diameter, 0.04 micron) sulfuric acid aerosols at 300 micrograms/m3 for 3 hr/day. The animals were euthanized immediately and 24 hr after 1 and 4 days of exposure and lungs were lavaged. Elevated beta-glucuronidase, lactate dehydrogenase activities, and total protein concentration as well as decreased cell viability were observed in the lavage after a single exposure to sulfuric acid aerosols of both sizes. These alterations were small, though statistically significant, and transient. No alteration in these parameters was observed after 4 days of exposure to acid aerosols. In contrast, sulfuric acid-induced alterations in alveolar macrophage function were more pronounced and longer lasting. Immediately after a single exposure to fine acid, there was a 2.7-fold increase in the spontaneous tumor necrosis factor (TNF) release over that in the control group while endotoxin-stimulated TNF release was increased by 2.2-fold. In addition, acid aerosols of both sizes increased the TNF release from macrophages after 4 days of exposure, although there was no clear temporal pattern of induction or recovery. Furthermore, immediately after 4 days of exposure to either fine or ultrafine acid, the amount of H2O2 that could be induced from baseline production by alveolar macrophages was 2.2-fold higher than that of the controls. The phagocytic function of macrophages was also altered by exposure to sulfuric acid aerosols. Twenty-four hours after single or multiple exposure, fine acid enhanced (as high as 78% above control) the in vitro phagocytic activity of alveolar macrophages while ultrafine acid depressed the phagocytic capacity (as much as 50% below that in the control). In addition to these biochemical parameters and cellular functions, we also measured the intracellular pH (pHi) of macrophages harvested after exposures to these acid aerosols using a pH-sensitive fluorescent dye. The resting pHi was depressed after a single exposure to both acid aerosols. The depression in pHi persisted 24 hr after ultrafine acid exposure.(ABSTRACT TRUNCATED AT 400 WORDS)

Aerosols↗

Inhalation provocation tests using nonisotonic aerosols.

The measurement of bronchial hyperresponsiveness with inhaled aerosols is now accepted as an objective measurement of the severity of asthma. The most commonly used agents administered as aerosols are methacholine and histamine, which are believed to cause airways to narrow by contracting bronchial smooth muscle via specific receptors. Patients with asthma may also have an attack provoked by inhaling aerosols that increase or decrease the osmolarity of the fluid lining the airways. There is evidence to suggest that a change in the osmolarity of the airways causes the release of mediators from inflammatory cells in the airways. Thus, inhalational challenge with nonisotonic aerosols, such as water and hyperosmolar saline, may be useful to assess bronchial hyperresponsiveness to endogenously released mediators. Described in this article are some of the techniques used to challenge with nonisotonic aerosols, and airway responses are discussed in relation to responses obtained with other bronchial provocation tests. The mechanisms whereby these aerosols cause airways to narrow are considered, and the clinical implications of identifying responsiveness to these aerosols are discussed. Specific recommendations are made with respect to equipment, technique, and choice of aerosol.

Aerosols↗

Aerosol exposure of pigs to viable or inactivated Actinobacillus pleuropneumoniae serotype 9 induces antibodies in bronchoalveolar lining fluids and serum, and protects against homologous challenge.

A dose-defined nose-only inhalation system for pigs was used to study the immunogenic and protective potentials of a single aerosol application of viable or killed Actinobacillus pleuropneumoniae serotype 9. Respiratory volumes were measured for each pig to calculate inhaled individual doses. Eight pigs inhaled 107 CFU A. pleuropneumoniae CVI 13261 reference strain for serotype 9. Another eight pigs received an identical dose of killed actinobacilli. After three weeks the pigs and nonexposed controls were challenged with 108 CFU of the homologous strain by aerosol. Bronchoalveolar lavage (BALF) in pigs was performed during the experiment to obtain lavage samples for assessment of local antibodies. Isotype-specific antibody responses in serum and BAL fluids were measured by ELISAs based on whole-cell antigens. The protective efficacy of aerosol immunization was evaluated by clinical and post-mortem examinations. The controls developed fever and severe pleuropneumonia, whereas previously exposed pigs had less fever and less extensive gross pulmonary lesions. After the first aerosol exposure pulmonary IgM, and IgG antibodies reactive with A. pleuropneumoniae increased significantly in both aerosol exposed groups. IgA in BALF and serum concentrations of each Ig class were significantly increased in the group exposed to viable bacteria when compared to the non-exposed controls. After aerosol challenge a pronounced increase of systemic and pulmonary IgA, IgM, and IgG antibodies was detected in both exposure groups. Aerosol application of whole-cell A. pleuropneumoniae bacterins induced similar protective effects against aerosol challenge infection as administration of an identical dose of viable bacteria. Inhalation of A. pleuropneumoniae may lead to asymptomatic carriers in some pigs that could spread the disease under field conditions.

Actinobacillus Infections↗

Different inhalation lethality between micron-sized and submicron-sized aerosols of organophosphorus insecticide, chlorfenvinphos, in rats.

This study was designed to evaluate that a difference in the route of absorption or the mode of lethality is responsible for the higher inhalation lethality of micron-sized organophosphorus insecticide, chlorfenvinphos (CVP), aerosols than the submicron-sized aerosols. Male Fischer 344 rats were exposed to the micron-sized (> 1 micron) or the submicron-sized aerosols (< 1 micron) for 4 h using the nose-only exposure system. LC50 of the micron-sized and the submicron-sized aerosols was 0.13 mg/l and 0.51 mg/l, respectively. Placing a drain cannula in the esophagus markedly increased LC50 of the micron-sized aerosols to 0.49 mg/l, but not that of the submicron-sized aerosols. There was no qualitative difference in lethal profile in cardiorespiration between 2 types of aerosols. The higher lethality of the micron-sized aerosols could be ascribed to swallowed CVP.

Absorption↗

Lidocaine blood levels following aerosolization and intravenous administration.

STUDY OBJECTIVE: To determine whether, following aerosolization of lidocaine for topical airway anesthesia, intravenous (IV) lidocaine produces toxic lidocaine blood concentrations. DESIGN: Randomized, double-blind study. SETTING: University-affiliated hospital. PATIENTS: Forty healthy patients scheduled for outpatient surgery. INTERVENTIONS: The patients received in a randomized, double-blind manner aerosolized lidocaine or placebo followed 10 minutes later by IV lidocaine or placebo. MEASUREMENTS AND MAIN RESULTS: After completion of lidocaine or placebo aerosolization and 2 minutes following IV administration of either lidocaine or the placebo, venous blood samples were obtained. Lidocaine concentration was measured using a homogenous enzyme assay. The group receiving both aerosolized and IV placebo and the group receiving aerosolized lidocaine and an IV placebo had undetectable (less than 0.05 micrograms/ml) serum lidocaine levels. The groups that received either an aerosolized placebo or aerosolized lidocaine and IV lidocaine had similar serum lidocaine concentrations [3.34 +/- 0.46 vs. 3.24 +/- 0.55 micrograms/ml (mean +/- SEM); p greater than 0.05 by Mann-Whitney U test]. CONCLUSION: IV lidocaine can be safely administered following aerosolization of lidocaine in spontaneously breathing patients without producing toxic blood lidocaine concentrations.

Aerosols↗

Other medications for aerosol delivery.

Although aerosol therapy is most commonly used to treat asthma and COPD, there are a large number of aerosol medications now used or in development for other diseases. Mucoactive agents have long been available by aerosol, but now we have truly effective drugs to improve effective airway clearance including dornase alfa, hyperosmolar saline, and aerosol surfactant. Inhaled antibiotics are available for the treatment of cystic fibrosis, bronchiectasis and other chronic airway infections. With the development of devices that can target aerosol to the deep lung, the opportunity to deliver medications systemically by the aerosol route has become a reality. Insulin, recently approved in the US as aerosol therapy, and other peptides are systemically absorbed from the distal airway and alveolus. Aerosol gene transfer therapy to correct abnormalities associated with cystic fibrosis, primary ciliary dyskinesia and other airway diseases also holds great potential.

Administration, Inhalation↗

Collection of three bacterial aerosols by respirator and surgical mask filters under varying conditions of flow and relative humidity.

A variety of respirator filters and surgical masks were challenged with three aerosolized bacteria: Mycobacterium abscessus (M.a.) (a rod), Staphylococcus epidermidis (S.e.) (a sphere), and Bacillus subtilis (B.s.) (a rod). Tests were conducted at two flow rates (45 and 85 l./min) and two humidity levels (30 and 70%). Aerosols were measured with a total-particle, direct-reading, spectrometer and a viable particle cascade impactor. Measurements up- and downstream of the filter or mask were used in determining aerosol penetration; respirator or surgical mask fit was not evaluated. Bioaerosol penetration measured with two aerosol sampling instruments was found to correlate. Additionally, bioaerosol test parameters were evaluated with respect to their effect on penetration. Increasing flow resulted in increased penetration of all organisms while an increase in relative humidity did not exert a consistent effect on all organisms. Of the respirators approved by the National Institute for Occupational Safety and Health (NIOSH), filter efficiency was as expected with dust/mist respirators having the lowest and HEPA filters the highest efficiency. Surgical masks were the least efficient of all filters tested; these are not certified by NIOSH. Bioaerosol penetration was compared to that of a polystyrene latex sphere (PSL) aerosol. Penetration of the test aerosols was predicted on the basis of particle aerodynamic diameter and was expected to be in this order: PSL > M.a. > S.e. = B.s. The PSL aerosol was the most penetrating, as predicted. However, results showed that B.s. was more penetrating than S.e. The aerodynamic diameter may not be the best parameter for predicting aerosol penetration of non-spherical particles in these filters.

Aerosols↗

Response to different measles vaccine strains given by aerosol and subcutaneous routes to schoolchildren: a randomised trial.

BACKGROUND: More than one dose of measles vaccine is necessary for the sustained control of measles. The aerosol route is thought to be more immunogenic for booster doses than traditional subcutaneous injections, so we did a randomised comparative trial of aerosol and subcutaneous measles vaccines in South African schoolchildren. METHODS: 4327 schoolchildren (aged 5-14 years), assigned by block randomisation of classrooms, received standard titre doses of either Schwarz or Edmonston-Zagreb measles vaccines subcutaneously or by aerosol. Blood samples for antibody assay were collected before vaccination, at 1 month, and 1 year after vaccination. The main endpoints (antibody titres at 1 month and 1 year) were compared between groups. FINDINGS: 992 children had antibody titre data available for all timepoints. 14 (3.6%) of 385 children who received Edmonston-Zagreb vaccine by aerosol were seronegative 1 year after vaccination, compared with 28 (8.6%) of 326 children who received Edmonston-Zagreb subcutaneous vaccine and 39 (13.9%) of 281 children who received Schwarz subcutaneous vaccine. At 1 month, 326 (84.7%) children who received aerosol Edmonston-Zagreb vaccine had seroconverted, compared with 257 (78.8%) who received subcutaneous Edmonston-Zagreb vaccine and 176 (62.6%) who received subcutaneous Schwarz vaccine. At 1 month, only 116 (22.7%) of 511 children in the Schwarz aerosol group had seroconverted; this aerosol vaccine had no detectable potency after 2 min of nebulisation. There were no serious side-effects: about 5% of children in each group had a rash within 2 weeks of vaccination. INTERPRETATION: An aerosol vaccination method that uses currently available devices and a suitably stable vaccine is effective and acceptable. This form of delivery is adaptable to mass campaigns, avoids the risks associated with injections, and could help measles eradication.

Administration, Inhalation↗

Can 99mTc-DTPA aerosol scanning predict radiation pneumonitis?

PURPOSE: To investigate whether changes in diethylenetriamine pentaacetic acid (DTPA) aerosol clearance lung scans predict the development of radiation pneumonitis. METHODS AND MATERIALS: Thirty-three patients with advanced non-small-cell lung cancer were treated with palliative radiation therapy to thorax. All patients were subjected to pretreatment and post-treatment DTPA aerosol clearance lung scans. The clearance t1/2 values were compared using the paired t test. Changes in percentage aerosol deposition were also compared. The patients were serially assessed clinically and radiologically for development of radiation pneumonitis. RESULTS: For the whole group, the mean DTPA clearance t1/2 for the diseased lung fell from 36.33 to 28.85 min (p = 0.17). Twelve patients developed radiation pneumonitis, 8 Grade 1, 2 Grade 2, 1 Grade 3, and 1 Grade 4. In patients who developed radiation pneumonitis, the clearance t1/2 for the diseased lung decreased from 37.50 min to 29.00 min after treatment (p = 0.50). Other subgroups analyzed, including smokers, nonsmokers, those with and without endobronchial disease, as well as those free from radiation pneumonitis, also showed no significant change in the clearance of the aerosol. The difference between the percentage aerosol deposition of the diseased lung (37.92%) and that of the opposite lung (62.08%) for the entire sample was significantly different both before and after treatment (p < 0.01). Delivery of radiation did not significantly change the aerosol deposition in either lung. CONCLUSIONS: We conclude that, in patients with advanced non-small-cell lung cancer, significant change in the pulmonary clearance of 99mTc-DTPA aerosol could not be demonstrated after radiation therapy. In such patients, clearance of the aerosol does not predict the development of radiation pneumonitis.

Adenocarcinoma↗

Is benzene a precursor for secondary organic aerosol?

It is currently assumed that benzene contributes only negligibly to secondary organic aerosol formation in the atmosphere. Our understanding of the capacity of benzene to generate secondary aerosols is based on the work of Izumi and Fukuyama (Atmos. Environ. 1990, 24A, 1433) in which two photosmog experiments with benzene in the presence of NOx were performed and no particle formation was observed. In contrast to the observations of Izumi and Fukuyama, experiments performed in the EUPHORE large outdoor simulation chamber have clearly shown aerosol formation during the photochemical oxidation of benzene in various NOx regimes. The maximum aerosol yields of 8-25% on a mass basis are comparable to yields obtained during the photochemical oxidation of other aromatic compounds under similar conditions. In addition, a density of 1.35+/-0.04 g/cm3 for the secondary organic aerosol from the benzene photochemical oxidation in the presence of NOx has been determined through the simultaneous measurement of aerosol volume and aerosol mass using two independent measurement techniques. Comparing the results in the present work with previous findings underscores the strong influence that the NOx content in the system has on aerosol formation during the photochemical oxidation of aromatic hydrocarbons and the importance of performing experiments with NOx concentrations relevant to the atmosphere.

Aerosols↗

Exceeding of Henry's law by hydrogen peroxide associated with urban aerosols.

Simultaneous measurements of gas- and aerosol-phase hydrogen peroxide (H2O2) have been made at two sites in Los Angeles, one near the Pacific coast at the University of California at Los Angeles (UCLA), and the other in downtown Los Angeles with close proximity to a heavily traveled freeway (freeway site). At both the freeway and UCLA sites, gas-phase H2O2 levels were similar, averaging 1.17 +/- 1.0 and 1.05 +/- 0.6 ppb, respectively. The particle-associated H2O2 in both fine (PM2.5) and coarse (>PM2.5) modes was higher at the freeway site, as compared to UCLA, by a factor of 2. However, when aerosol-phase H2O2 is normalized to particle mass loadings, the fine-mode H2O2 levels are very similar at the two sites: 0.42 +/- 0.3 and 0.58 +/- 0.3 ng H2O2/microg particle mass at the freeway and UCLA sites, respectively. The normalized coarse-mode H2O2 levels were significantly higher at the freeway site than at UCLA, 1.05 +/- 0.3 and 0.51 +/- 0.3 ng/microg, respectively. Estimating aerosol liquid water content on the basis of relative humidity and aerosol mass, a calculated equivalent H2O2 in aerosol liquid water averages 70 mM, more than 2 orders of magnitude higher than concentrations predicted by gas-particle partitioning (Henry's law), which averages 0.1 mM. This indicates that the sampled particles are capable of generating H2O2 in aqueous solution. These corresponding aqueous-phase H2O2 concentrations in aerosol liquid water exceed levels that have been observed to produce cellular damage to lung epithelial cells in laboratory experiments by at least 3 orders of magnitude. Although most measurements of H2O2 in particles were made using an extraction solution adjusted to pH 3.5, a set of measurements indicates that H2O2 from fine-mode particles extracted in the physiologically relevant pH range 5-7.5 also generate H2O2 with only slightly lowered efficiency; coarse-mode H2O2 production dropped by 75% at the upper end of this range. Finally, a small set of measurements was performed to investigate the degree to which the recently developed Versatile Aerosol Concentrator Enrichment System (VACES) affects H2O2 levels in concentrated ambient aerosols. The VACES appeared to a have minimal impact on particulate H2O2.

Aerosols↗