Bacterial identification by infrared spectrophotometry. II. Effect of instrumental and environmental variables.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: The pediatric variable stiffness colonoscope is believed to have theoretical advantages over the standard colonoscope, however a systematic evaluation of this instrument in routine clinical practice involving adult patients is lacking. METHODS: Consecutive patients (blinded) undergoing colonoscopy in an outpatient endoscopy center by one of 4 experienced colonoscopists had the procedure performed with a standard colonoscope (n=384) or pediatric variable stiffness colonoscope (n=413). Failure to negotiate the sigmoid colon within 10 minutes was regarded as a failure and, if suitable, the patient was crossed over to colonoscopy with the alternative instrument. RESULTS: Median (95% CI) time to the cecum was significantly faster in the pediatric variable stiffness colonoscope group (odds ratio 5.0: 95% CI[4.7,5.3] minutes) compared with the standard colonoscope group (odds ratio 5.5: 95% CI[5.2,5.8] minutes, p=0.01). There were 22 failures overall (2.8%), 14 in the standard colonoscope group (3.6%) and 8 in the pediatric variable stiffness colonoscope group (1.9%; p=0.1). With regard to the 14 failures in the standard colonoscope group, colonoscopy was attempted with the pediatric variable stiffness colonoscope in 13 and completed successfully in 12 (92%). The pediatric variable stiffness colonoscope was superior in cases of severe stenosing diverticular disease; two of 27 examinations with the pediatric variable stiffness colonoscope were rated as failed vs. 12 of 18 with the standard colonoscope (p<0.001). CONCLUSIONS: Intubation time was faster with the pediatric variable stiffness colonoscope, but use of this instrument was not associated with a superior cecal intubation rate compared with the standard colonoscope. However, in patients with severe stenosing diverticular disease, the intubation rate with the pediatric variable stiffness colonoscope was superior.
Real-time myocardial contrast echo (MCE) provides the potential to assess myocardial blood flow from time-intensity refilling curves after high-energy bubble destruction. This study validated the accuracy of this approach and the effect of specific examination variables and instrument settings on results. The effects of examination depth and angle as well as dynamic range, pulse repetition frequency, and line density were assessed with the use of in vitro incremental flow rates produced in an in vitro tissue phantom. In vivo recordings of real-time imaging with an infusion of a contrast agent (Optison) were obtained in 7 open-chest dogs with graded left anterior descending artery stenosis at baseline and during adenosine hyperemia, and were compared with flow probe measurements. After bubble destruction, time-intensity data were fitted to an exponential function, and the rate of intensity increase (b) and peak plateau intensity (A) were derived from refilling curves. In vivo real-time values for b, but not A, correlated closely with flow probe measures (r = 0.93). A similar correlation for b was observed in vitro (r = 0.98). The correlation between flow rate and b was influenced by several examination variables, including depth, angle, and instrument settings. Real-time MCE provides accurate quantification of coronary flow by assessing the rate of microbubble refilling. However, this parameter may be affected by several examination and instrument variables. Therefore, real-time MCE refilling measures are best applied by comparing baseline values with those of stress studies.
Data from the U.S. Environmental Protection Agency Air Quality System, the Southeastern Aerosol Research and Characterization database, and the Assessment of Spatial Aerosol Composition in Atlanta database for 1999 through 2002 have been used to characterize error associated with instrument precision and spatial variability on the assessment of the temporal variation of ambient air pollution in Atlanta, GA. These data are being used in time series epidemiologic studies in which associations of acute respiratory and cardiovascular health outcomes and daily ambient air pollutant levels are assessed. Modified semivariograms are used to quantify the effects of instrument precision and spatial variability on the assessment of daily metrics of ambient gaseous pollutants (SO2, CO, NOx, and O3) and fine particulate matter ([PM2.5] PM2.5 mass, sulfate, nitrate, ammonium, elemental carbon [EC], and organic carbon [OC]). Variation because of instrument imprecision represented 7-40% of the temporal variation in the daily pollutant measures and was largest for the PM2.5 EC and OC. Spatial variability was greatest for primary pollutants (SO2, CO, NOx, and EC). Population-weighted variation in daily ambient air pollutant levels because of both instrument imprecision and spatial variability ranged from 20% of the temporal variation for O3 to 70% of the temporal variation for SO2 and EC. Wind
OBJECTIVE: To test the psychometric properties of an instrument for measuring psychological variables and adherence to treatment behaviors in persons with HIV infection or AIDS. METHODS: A cross-sectional study was performed with 68 subjects who were seropositive for the human immunodeficiency virus (HIV) and who were being treated in a health facility in the city of Hermosillo (Sonora), Mexico, at the time the study was carried out. Five consecutive statistical testing procedures were applied for data analysis: the Student t test for comparison of means, for assessing the comprehensibility of the questions; an exploratory factorial analysis with varimax rotation for determining construct validity; Cronbach's alpha coefficient for determining reliability; Pearson's correlation coefficient (r) for assessing concurrent validity; and multiple linear regression for determining predictive value. RESULTS: In 25 out of a total of 30 questions, the Student t test for comparison of means gave statistical significance values of P < or = 0.05, P < or = 0.005, P < or = 0.01, and P < or = 0.001. A four-factor structure was found with the factorial analysis with varimax rotation: (1) current adherence behavior and treatment; (2) underlying reasons for adherence or lack of adherence; (3) psychological well-being and social competencies; (4) past adherence behavior with values above 1 that, taken as a whole, explain 65.50% of the variance. An overall alpha coefficient of 0.852 was obtained with the test for reliability. The test for concurrent validity showed correlations between factors 1 and 2 (r = 0.615; P < or = 0.01), between factor 2 and factors 3 and 4 (r = -0.178; P < 0.05 and r = 0.265; P < 0,05, respectively), and between factor 3 and duration of infection in months (r = 0.265; P < 0.05). Finally, multiple linear regression showed that psychological factors 2 and 4, which together explain 48.6% of the variance, predicted current adherence behavior (adjusted determination coefficient [R2] = 0.486). CONCLUSION: According to the results obtained, the instrument has optimal reliability as well as construct validity, concurrent validity, and predictive validity.
BACKGROUND: Push enteroscopy is a well-established technique for evaluation of the small intestine. However, looping of the enteroscope within the stomach limits depth of insertion. Stiffening overtubes that minimize gastric looping are tolerated marginally by patients and disliked by endoscopists. A variable stiffness instrument has the potential to eliminate the need for an overtube while still minimizing gastric looping. The performance of a prototype variable stiffness enteroscope was compared prospectively with that of a conventional push enteroscope with and without use of an overtube. METHODS: Consecutive patients undergoing enteroscopy were randomized to have the procedure with a variable stiffness instrument, a conventional instrument with overtube, or a conventional instrument without overtube. Depth of insertion distal to the ligament of Treitz was determined by plain abdominal radiography. OBSERVATIONS: In total, 67 patients were randomized to variable stiffness enteroscopy (25 patients), enteroscopy with overtube (23 patients), and enteroscopy without overtube (19 patients). Median depth of insertion distal to the ligament of Treitz, respectively, for each group, was 89 cm, 68 cm and 41 cm (p = 0.03). In multivariate analysis, variable stiffness instrument use was predictive of intubation to 65 cm distal to the ligament of Treitz (odds ratio 5.53: 95% CI [1.25, 31.25] vs. no overtube, and odds ratio 2.50: 95% CI [0.63, 11.1] vs. overtube). Procedure duration and overall patient tolerance did not differ significantly among the 3 groups, although more patients in the overtube group required additional sedation than patients in the variable stiffness group (p = 0.03). Both endoscopists' (r = 0.34) and nurses' (r = 0.36) estimates of patient discomfort during the procedure correlated poorly with patient tolerance. CONCLUSIONS: A variable stiffness push enteroscope enhances insertion depth compared with the conventional instrument with or without overtube. Further studies are required to determine whether this improved performance increases diagnostic yield.
INTRODUCTION: A study was designed to assess variability between different fluorescence spectroscopy devices. Measurements were made with all combinations of three devices, four probes, and three sets of standards trays. Additionally, we made three measurements on the same day over 2 days for the same combination of device, probe, and standards tray to assess reproducibility over a day and across days. MATERIALS AND METHODS: The devices consisted of light sources, fiber-optics, and cameras. We measured thirteen standards and present the data from the frosted cuvette, water, and rhodamine standards. A preliminary analysis was performed with the data that were wavelength calibrated and background subtracted; however, the system has not been corrected for systematic intensity variations caused by the devices. Two analyses were performed on the rhodamine, water, and frosted cuvette standards data. The first one is based on first clustering the measurements and then looking for association between the 5 factors (device, probe, standards tray, day, measurement number) using chi-squared tests on the cross-tabulation of cluster and factor level. This showed that only device and probe were significant. We then did an analysis of variance to assess the percent variance explained by each factor that was significant from the chi-squared analysis. RESULTS: The data were remarkably similar across the different combinations of factors. The analysis based on the clusters showed that sometimes devices alone, probes alone, but most often combinations of device and probe caused significant differences in measurements. The analysis showed that time of day, location of device, and standards trays do not vary significantly; whereas the devices and probes account for differences in measurement. We expected this type of significance using unprocessed data since the processing corrects for differences in devices. However, this analysis on raw data is useful to explore what combination of device and probe measurements should be targeted for further investigation. This experiment affirms that online quality control is necessary to obtain the best excitation-emission matrices from optical spectroscopy devices. CONCLUSION: The fact that the device and probe are the primary sources of variability indicates that proper correction for the transfer function of the individual devices should make the measurements essentially equivalent.
The use of stable-isotope tracer methodology to study substrate metabolic kinetics requires accurate measurement of the tracer to tracee ratio (TTR), often by gas chromatography/mass spectrometry (GC/MS). Many approaches for measurement of the TTR by GC/MS do not use standards of known isotopic enrichment to control for variability in instrument response. In addition, most GC/MS applications exhibit some degree of concentration dependency whereby the measured ion abundance ratio varies with the quantity of sample analyzed, thereby placing a limitation on the accuracy of isotopic enrichment standard curves unless the quantities of standards and samples analyzed are closely matched. We document the degree to which day-to-day variability can affect the instrument response for several GC/MS analyses of metabolic tracers when isotopic enrichment standards are not used to control for variable instrument response. Furthermore, we report a new approach that incorporates concentration dependencies within a standard curve to improve the accuracy and precision of TTR measurements over a range of sample quantities analyzed. The new approach was applied to plasma samples obtained from experimental protocols performed in human subjects with three commonly used tracers: 2H2-palmitate, 15N2-urea, and 13C-leucine. Variability in the day-to-day instrument response was 84% and 26% for 2H2-palmitate and 15N2-urea, respectively; in addition, up to 10% variability due to concentration dependency was noted for these applications. The new approach virtually eliminated these sources of variability. After controlling for concentration dependency, a threefold reduction in the standard error was noted when the enrichment of 13C-leucine measured by electron-impact (EI) ionization GC/MS was correlated against negative chemical ionization (NCI) GC/MS. These data demonstrate that our new approach decreases the errors in TTR determination caused by variations in instrument response and concentration dependency. This approach is generically applicable, and can improve the accuracy and precision of TTR determinations for most GC/MS analyses.
A method for simulation of acoustical bores, useful in the context of sound synthesis by physical modeling of woodwind instruments, is presented. As with previously developed methods, such as digital waveguide modeling (DWM) [Smith, Comput. Music J. 16, 74-91 (1992)] and the multi convolution algorithm (MCA) [Martinez et al., J. Acoust. Soc. Am. 84, 1620-1627 (1988)], the approach is based on a one-dimensional model of wave propagation in the bore. Both the DWM method and the MCA explicitly compute the transmission and reflection of wave variables that represent actual traveling pressure waves. The method presented in this report, the wave digital modeling (WDM) method, avoids the typical limitations associated with these methods by using a more general definition of the wave variables. An efficient and spatially modular discrete-time model is constructed from the digital representations of elemental bore units such as cylindrical sections, conical sections, and toneholes. Frequency-dependent phenomena, such as boundary losses, are approximated with digital filters. The stability of a simulation of a complete acoustic bore is investigated empirically. Results of the simulation of a full clarinet show that a very good concordance with classic transmission-line theory is obtained.
Fetal heart rate (FHR) and oxygen consumption were determined in 45 studies in 20 chronically instrumented, normoxic sheep. FHR variability was measured by a template device to determine amplitude range, and oscillatory frequency was manually counted over 5-min periods. During 26 min of isocapnic hypoxia, fetal O2 consumption decreased 39% and FHR decreased 18%, and FHR variability increased, the changes being maintained over the treatment period. It is suggested that the maintenance of FHR variability during this profound hypoxia denotes adequate cardiorespiratory compensatory mechanisms during the short period; prolongation of the hypoxia would probably result in fetal cerebral or myocardial decompensation, and disappearance of FHR variability. The increased variability may be due to increased alpha-adrenergic activity.
OBJECTIVE: To assess the clinical performance of glucose meter systems when used with critically ill patients. DESIGN: Two glucose meter systems (SureStepPro and Precision G) and a modular adaptation (Immediate Response Mobile Analysis-SureStepPro) were assessed clinically using arterial samples from critically ill patients. A biosensor-based analyzer (YSI 2700) and a hospital chemistry analyzer (Synchron CX-7) were the primary and secondary reference instruments, respectively. PATIENTS AND SETTING: Two hundred forty-seven critical care patients at the University of California, Davis, Medical Center participated in this study. OUTCOME MEASURES: Error tolerances of +/-15 mg/dL for glucose levels </=100 mg/dL and +/-15% for glucose levels >100 mg/dL were used to evaluate glucose meter performance; 95% of glucose meter measurements should fall within these tolerances. RESULTS: Compared to the primary reference method, 98% to 100% of SureStepPro and 91% to 95% of Precision G measurements fell within the error tolerances. Paired differences of glucose measurements versus critical care variables (Po(2), pH, Pco(2), and hematocrit) were analyzed to determine the effects of these variables on meter measurements. Po(2) and Pco(2) decreased Precision G and SureStepPro measurements, respectively, but not enough to be clinically significant based on the error tolerance criteria. Hematocrit levels affected glucose measurements on both meter systems. Modular adaptation did not affect test strip performance. CONCLUSIONS: Glucose meter measurements correlated best with primary reference instrument measurements. Overall, both glucose meter systems showed acceptable performance for point-of-care testing. However, the effects of some critical care variables, especially low and high hematocrit values, could cause overestimated or underestimated glucose measurements.
Secure fixation of the sacrum is technically challenging. The bone of the dorsal sacral surface is often thin, making hook fixation tenuous. The use of bone screws in the sacral pedicles has gained popularity, but rigidity is often not achieved and screw pullout is common. Solid constructs have been achieved using angled rods to stabilize the ilium, but these methods are technically difficult and time-consuming to perform. A technique is described that achieves rigid sacral fixation by adding a bone screw placed through both cortical surfaces of the ilium. This bone screw is a new type that allows attachment to a rod at variable angles. It permits easy attachment to an appropriately contoured rod, which is affixed to sacral hooks or screws. The resulting configuration of the bone-metal interface creates a tripod for load distribution. Additionally, the splayed geometry of these purchase sites provides a significant biomechanical advantage preventing the instrument from being pulled out. The technique for this fixation method, particularly for patients with complex spinal disorders, is described. Use of this new technique provides significant advantages to the spine surgeon in situations in which substantial sacral fixation integrity is necessary.
This report reviews individual-related variables (age, sex, race, anatomical site, skin surface properties), intra- and interindividual variation (temporal, physical and mental activity, orthostatic effect, menstrual cycle/menopause), environment-related variables (light conditions, temperature) and various instrument-related variables that influence skin colour. CIE colorimetry (Minolta Chroma Meter) and spectrophotometric measurement (Derma Spectrometer) are considered. The guidelines give recommendations for measuring conditions and procedures.
AIM: To compare the shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals with different curvature and radius. METHODOLOGY: ProFile or K3.06 taper instruments were used to prepare simulated canals of 20 degrees curvature and 5 mm radius (n = 10) and 30 degrees curvature and 3 mm radius canals (n = 10) in resin blocks. All canals were prepared to an apical size 40 at 0.5 mm from the canal terminus using a variable tip crown-down sequence. Pre- and postinstrumentation digital images were recorded, and an assessment of the canal shape was determined using a computer image analysis program. The material removal from the inner and outer wall of the canal was measured at 28 measuring points, beginning 0.5 mm from the end-point of the canal and the data compared using the Mann-Whitney U-test. RESULTS: In 20 degrees and 30 degrees canals both instruments significantly removed more (P < 0.05) material on the outer wall than the inner wall in the apical half of the canal. For ProFile files there was no significant difference in the amount of material removed on the outer canal wall between the 20 degrees and 30 degrees canals. However, in the K3 groups significantly more (P < 0.05) outer canal wall was removed in the apical area in 20 degrees canals. When comparing both instruments the results showed that in 20 degrees canals K3 instruments removed more outer and inner canal wall than ProFile instruments (P < 0.05) but that there was no significant difference (P > 0.05) between the instruments in 30 degrees canals. CONCLUSION: Within the limitation of this study, both rotary nickel-titanium instruments prepared a well-shaped root canal with minimal canal transportation.
An instrument providing cyclic stress to cells cultured in vitro has been developed. The unit uses a vacuum to deform a plastic Petri dish yielding 0.13% compression to cells on the inner surface, measured by strain gauge recordings. A regimen of 25 s stress and 5 min relaxation induced no significant change in synthesis of a 45 X 10(3) Mr protein that comigrates with actin, whereas a 52 X 10(3) Mr protein that comigrated with tubulin decreased from 12.7 +/- 0.451% of the total protein synthesized in control, static cells to 8.53 +/- 0.182% in stressed cells. The unit may have a broad application in monitoring biochemical changes in response to stress in cells such as muscle, lung, tendon, ligament and bone that are normally subjected to tension or compression.
Explore the source record for details and available documents.