The dual-tube microsurgical suction instrument.

A dual-tube suction instrument intended for both macro- and microsurgery has been developed. A detachable air-tight inner tube is fitted into a conventional suction instrument; extending the ordinary sucking tube. The inner tube can easily be fitted, as well as removed from the other tube; a particular advantage in case the inner tube becomes obstructed. On removal of the inner tube the outer tube becomes cleaned and is at once, ready for re-use. Since the suction instrument does not have to be removed from the suction hose, valuable time is saved, enabling permanent sucking capacity.

Equipment Design↗

The effects of suctioning techniques on the distal tracheal mucosa in intubated low birth weight infants.

Microscopic pathology of the distal trachea at autopsy was retrospectively reviewed in 51 low birth weight infants (less than 1250 g). Twenty-six patients from 1977 who had nasal and/or orotracheal intubation and who underwent suctioning with uncontrolled deep suctioning technique were compared to 25 patients from 1980 who had orotracheal intubation with suctioning to the tube tip only. Clinical diagnoses, duration of intubation and number of intubations were correlated to degree of distal tracheal injury: absent (normal epithelium), mild (focal epithelial loss), moderate (diffuse epithelial loss/some inflammation), or severe (submucosal ulceration/squamous metaplasia). From 1977 to 1980 the mortality rate, mean gestational age and mean birth weight all decreased by 20% (P less than 0.05), 1.1 week (P less than 0.05) and 118 g (P less than 0.01) in both autopsied and non-autopsied infants. In 1977, 15 of 26 autopsies (58%) revealed mild (6), moderate (5) or severe (4) pathology. The mean duration of intubation was 71.3, 11.8, and 265 h. respectively. No history of intubation was obtained in two patients with mild injury. No significant tracheal pathology was seen in 11 patients (42%) in 1977. In 1980, fewer patients, 10 of 24 autopsies (42%), revealed mild (3), moderate (4) or severe (3) pathology. The mean duration of intubation was 19.3, 318.3 and 1391.3 h, respectively. One patient with no history of intubation had mild tracheal injury. No significant tracheal pathology was seen in 15 patients (58%) in 1980. The diagnoses of hyaline membrane disease, anemia, hyperbilirubinemia and coagulation disorder were seen more frequently in patients with moderate and severe tracheal pathology both in 1977 and 1980. Despite factors which should lead to greater tracheal injury--longer duration of intubation, lower birth weights and younger gestational age--less tracheal injury was seen in infants undergoing careful suctioning techniques. Clinical implications for the low birth weight neonate are discussed.

Bronchi↗

Preservation of regional myocardial function and myocardial oxygen tension during acute ischemia in pigs: comparison of selective synchronized suction and retroinfusion of coronary veins to synchronized coronary venous retroperfusion.

OBJECTIVES: The efficacy of selective synchronized suction and retroinfusion of coronary veins was compared with synchronized coronary venous retroperfusion in preventing ischemic reduction of regional myocardial function and myocardial oxygen tension. BACKGROUND: Because incomplete protection by synchronized coronary venous retroperfusion during ischemia might result from nonselective retroinfusion and only passive drainage of the veins, a suction device was added to a retroinfusion system. METHODS: Regional myocardial function (ultrasonic crystals) and myocardial oxygen tension (polarographic electrodes) were studied in 30 pigs during 10-min occlusion of the left anterior descending coronary artery (ischemia), followed by reperfusion. During ischemia, group A (n = 10) was supported by selective synchronized suction and retroinfusion; group B (n = 10) was supported by synchronized coronary venous retroperfusion, and group C (n = 10) was not supported by retroinfusion. RESULTS: In group A, subendocardial segment shortening decreased from 21 +/- 4% (mean +/- SD) before ischemia to 11 +/- 5% during ischemia. In contrast, systolic dyskinesia was observed in group B (-2 +/- 4%, p < 0.001) and group C (-2 +/- 5%, p < 0.001). During ischemia, the decrease in intramyocardial oxygen tension was less pronounced in group A (41 +/- 15 vs. 27 +/- 12 mm Hg) than in group B (40 +/- 10 vs. 19 +/- 10 mm Hg, p = 0.1) or group C (33 +/- 11 vs. 12 +/- 8 mm Hg, p = 0.002). During ischemia, myocardial surface oxygen tension was preserved > 0 mm Hg only in group A. CONCLUSIONS: Preservation of regional myocardial function and myocardial oxygen tension was substantially higher by selective synchronized suction and retroinfusion of coronary veins than by synchronized coronary venous retroperfusion in pigs.

Animals↗

Improvement in suction catheter efficiency and safety in arterial operations.

The Blood Shield is a new device which has been developed to attach easily to the tip of a conventional suction catheter. Two experiments were performed to determine if the Blood Shield could limit the degree of splash which occurs during vascular graft flushing and whether it could increase the efficiency of a standard suction tip in collecting shed blood for autotransfusion. The results of the experiments indicate that the Blood Shield, when added to a conventional suction catheter, diminishes the amount of spray which may occur during anastomotic flushing. Secondly, it more effectively collects blood from a flushed anastomosis or arteriotomy in comparison with a suction catheter alone.

Anastomosis, Surgical↗

Comparison of water seal and suction after pulmonary lobectomy: a prospective, randomized trial.

BACKGROUND: The objective of the present study was to assess whether placing chest tubes on water seal after pulmonary lobectomy reduced the duration of air leak compared with suction. METHODS: One hundred forty-five patients who underwent pulmonary lobectomy for lung cancer and with an air leak on the first postoperative day were prospectively randomly assigned to two groups: in group 1 (72 patients), chest tubes were placed on water seal on the morning of the first postoperative day; in group 2 (73 patients), chest tubes were on continuous suction (-20 cm H(2)O). Eighty percent of the patients who underwent upper lobectomy had also a pleural tent procedure. Preoperative, operative, and postoperative variables were compared between the groups. RESULTS: The two groups were evenly matched for preoperative and operative characteristics. No statistically significant differences were found between group 1 and group 2 in terms of air leak duration (6.5 versus 6.3, respectively; p = 0.9) and the incidence of prolonged air leak cases (27.8% versus 30.1%, respectively; p = 0.8). Similar results were obtained when the analysis was corrected for the length of the stapled parenchyma and the site of resection (upper and lower resections) or restricted to patients with a forced expiratory volume in 1 second less than 80% of predicted. Water seal patients had increased postoperative complications compared with suction patients (31.9% versus 17.8%, respectively; p = 0.056). CONCLUSIONS: Chest tubes placed on water seal after pulmonary lobectomy were generally well tolerated and safe; however, they did not reduce the duration of air leak or the incidence of prolonged air leak compared with suction.

Aged↗

Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device.

BACKGROUND: Displacement of the heart to expose posterior vessels during off-pump coronary artery bypass may cause hemodynamic derangement. The aims of this study were (1) to elucidate the hemodynamic changes during off-pump coronary artery bypass for the obtuse marginal branch (OM) of the left circumflex artery; and (2) to compare the hemodynamic changes caused by a deep pericardial suture technique with those caused by a vacuum-assisted apical suction device for displacement of the heart. METHODS: Hemodynamic changes during posterior vessel off-pump coronary artery bypass were studied in a prospective randomized manner. A deep pericardial suture technique (group 1, n = 10) or a vacuum-assisted apical suction device (group 2, n = 10) was used to facilitate the exposure of the OM. Hemodynamic variables such as cardiac index, stroke volume index (SVI), mean arterial pressure, mean pulmonary artery pressure, central venous pressure, pulmonary capillary wedge pressure, heart rate, systemic vascular resistance, pulmonary vascular resistance, left ventricular stroke work index, and right ventricular stroke work index were monitored during off-pump coronary artery bypass. Hemodynamic data were obtained before revascularization of the left anterior descending coronary artery at a baseline (T0), 3 minutes after heart displacement for revascularization of OM (T1), 3 minutes after the beginning of OM grafting (T2), and 3 minutes after the completion of OM grafting and heart repositioning (T3). RESULTS: There were no significant differences in the baseline hemodynamic variables (T0) between the two groups. In group 1, SVI, cardiac index, left ventricular stroke work index, and right ventricular stroke work index decreased significantly, and central venous pressure and pulmonary capillary wedge pressure increased significantly, during displacement of the heart (T1, p < 0.05). In group 2, SVI decreased significantly, and central venous pressure, pulmonary capillary wedge pressure, and mean pulmonary artery pressure increased significantly during displacement of the heart (T1, p < 0.05). The percent changes of cardiac index, SVI, and right ventricular stroke work index during OM grafting (T2) in comparison with baseline values (T0) were significantly larger in group 1 than in group 2 (cardiac index, 73% +/- 12% versus 90% +/- 11%; SVI, 69% +/- 12% versus 86% +/- 8%; right ventricular stroke work index, 30% +/- 17% versus 71% +/- 25%, in groups 1 versus 2, respectively; p < 0.05). CONCLUSIONS: Displacement of the heart using either a deep pericardial suture technique or a vacuum-assisted apical suction device caused a significant decrease in SVI. The hemodynamic changes during OM grafting were smaller when using a vacuum-assisted apical suction device.

Blood Pressure↗

A randomized comparison of sublingual and vaginal misoprostol for cervical priming before suction termination of first-trimester pregnancy.

This randomized trial compares the efficacy and side effects of sublingual and vaginal misoprostol for cervical priming before first-trimester pregnancy termination. One-hundred pregnant women between 6 and 12 weeks of gestation opting for termination of pregnancy by suction evacuation were included in this study. The women were randomly allocated into two groups. Group 1 received 400 microg of sublingual misoprostol and group 2 received 400 microg of vaginal misoprostol 2 h prior to suction evacuation. The abortion was carried out by suction evacuation using a Karman's cannula attached to an electrically operated suction machine under intravenous analgesia. Baseline cervical dilatation, duration of the procedure, operative blood loss, side effects and complications were noted in both groups. There was a significant difference between the sublingual and vaginal misoprostol groups with respect to mean cervical dilatation (8.6 mm vs. 6.8 mm, p < 0.05). However, the duration of the procedure (3.03 min vs. 3.16 min) and the amount of blood loss (29 mL vs. 31.2 mL) were not significantly different between the two groups. The women in the sublingual group experienced significantly more shivering and preoperative vaginal bleeding (68% vs. 56%, p < 0.05). None of the women in the two groups had either uterine perforation or excessive hemorrhage. In our study, sublingual misoprostol (400 microg) was significantly more effective in facilitating cervical dilation prior to surgical abortion than vaginal misoprostol.

Abortifacient Agents, Nonsteroidal↗

Closed versus partially ventilated endotracheal suction in extremely preterm neonates: physiologic consequences.

This randomized cross over study aimed to compare the severity and incidences of desaturation and bradycardia between the partially ventilated endotracheal suction method (PVETS) and closed tracheal suction system (CTSS) in extremely preterm neonates. Fifteen intubated and ventilated extremely low birth weight preterm infants (mean birth weight 689g) randomly underwent both suction techniques within a 12-h period to obtain a paired reading group. The process was repeated 24-48h apart until three pairs of reading groups were collected. Changes in oxygen saturation measured with pulse oximetry and heart rate changes measured with electrocardiogram were recorded using Hewlett-Packard m240A monitor trending software. The mean of each parameter's variation from baseline was obtained using SPSS descriptive statistics and analyzed using SPSS repeated measures ANOVA. Fisher Exact Test was used to analyze the incidence of desaturation and bradycardia. The closed tracheal suction system reported a significantly smaller degree of oxygen saturation fall (P<0.005) and significantly fewer incidences of desaturation. There was also a significantly smaller degree of heart rate reduction although episodes of bradycardia were not significantly different between the two methods. Oxygen saturation and heart rate were significantly more stable during the use of CTSS compared to PVETS in the extremely low birth weight preterm population.

Analysis of Variance↗

Is nasogastric suction necessary after elective colon resection?

It is commonly held that nasogastric suction is necessary after colon resection to prevent small and large bowel distension, wound complications, and anastomotic problems. In this retrospective study of 118 patients undergoing colon resection for malignancy or inflammatory disease, 83 underwent postoperative nasogastric suction and 35 did not. A wide variety of postoperative variables were evaluated in these two groups of patients and few differences were found. However, there were trends toward shorter postoperative hospital stays, and less abdominal distension, nausea, and vomiting could be discerned in the patients who did not undergo nasogastric suction. This retrospective study suggests that routine nasogastric suction may not be necessary or useful after elective colon resection.

Colon↗

Bubble oxygenation and cardiotomy suction impair the host defense during cardiopulmonary bypass: a study in dogs.

Decreased complement levels and impairment of polymorphonuclear leukocyte function increase the risk of infection during cardiopulmonary bypass (CPB). The effects of different types of oxygenator and of blood suction on this natural humoral and cellular host defense mechanism were investigated in dogs undergoing CPB during sham open-heart operations. Airborne contamination of the wound area and the CPB circuit was performed by aerosolizing Staphylococcus aureus. A membrane oxygenator in the CPB circuit maintained a normal host defense mechanism. The use of cardiotomy suction during CPB with this type of oxygenator affected the host defense to some extent. The use of a bubble oxygenator in the CPB circuit together with cardiotomy suction seriously impaired the host defense. Postoperatively bacteremia developed in no dogs in the membrane oxygenator group, whereas 8 of 15 dogs in the bubble oxygenator group had a positive blood culture for the indicator microorganism. We conclude that the use of a membrane oxygenator is helpful to maintain the host defense. Attention has to be paid to reduce the deleterious effects of cardiotomy suction.

Animals↗

Reduced threshold to suction-induced blister formation in insulin-dependent diabetics.

Diabetics may have an increased susceptibility to cutaneous blister formation clinically manifest as the bullous eruption of diabetes. We evaluated the mechanical force necessary to induce suction blisters in fifteen insulin-dependent diabetics and twenty age-matched normal controls. The mean suction blister threshold for the diabetics was 31.9 minutes versus 68.0 minutes for the controls, a highly significant difference (p less than 0.01). Histologic appearance of suction blisters was similar in diabetic and normal skin, under both light and electron microscopic examination, with a noninflammatory subepidermal separation in the lamina lucida between the cell membrane and the basal lamina. These results demonstrate that insulin-dependent diabetics have a marked reduction in suction blister threshold as compared to age-matched controls.

Adult↗

Appropriate suction device in rescue medicine.

In rescue medicine, a suction apparatus must function in a variety of environmental conditions. To find an appropriate device for the Swedish Air Force air rescue service the Laerdal suction device 790,000 was selected for further testing according to international standards for aviation safety. Tests showed that vibrations had deleterious effects on the internal construction of the suction device. In addition, an electromagnetic field was generated affecting the navigation, autopilot, and communication systems. We conclude that the suction apparatus and probably other devices as well must be tested for their functioning in adverse environments and their ability to meet international aviation safety regulations.

Aviation↗

Suction for venomous snakebite: a study of "mock venom" extraction in a human model.

STUDY OBJECTIVE: We determine the percentage of mock venom recovered by a suction device (Sawyer Extractor pump) in a simulated snakebite in human volunteers. METHODS: A mock venom (1 mL normal saline solution, 5.0 mg albumin, 2.5 mg aggregated albumin) radioactively labeled with 1 mCi of technetium was injected with a curved 16-gauge hypodermic needle 1 cm into the right lateral lower leg of 8 supine male volunteers aged 28 to 51 years. The Sawyer Extractor pump was applied after a 3-minute delay, and the blood removed by suction was collected after an additional 15 minutes. A 1991 Siemens Diacam was used to take measurements of the radioactive counts extracted and those remaining in the leg and body. RESULTS: The "envenomation load," as measured by mean radioactivity in the leg after injection, was 89,895 counts/min. The mean radioactivity found in the blood extracted in the 15 minutes of suction was 38.5 counts/min (95% confidence interval [CI] -33 to 110 counts/min), representing 0.04% of the envenomation load. The postextraction leg count was less than the envenomation load by 1,832 counts/min (95% CI -3,863 to 200 counts/min), representing a 2.0% decrease in the total body venom load. CONCLUSION: The Sawyer Extractor pump removed bloody fluid from our simulated snakebite wounds but removed virtually no mock venom, which suggests that suction is unlikely to be an effective treatment for reducing the total body venom burden after a venomous snakebite.

Adult↗

Selective suction and pressure-regulated retroinfusion: an effective and safe approach to retrograde protection against myocardial ischemia in patients undergoing normal and high risk percutaneous transluminal coronary angioplasty.

OBJECTIVES: We sought to study the safety, feasibility and efficacy of selective suction and pressure-regulated retroinfusion to protect against myocardial ischemia in patients undergoing normal risk and high risk balloon angioplasty. BACKGROUND: In a pig model of acute myocardial ischemia it was previously shown that use of selective suction and pressure-regulated retroinfusion was able to substantially preserve regional myocardial function during ischemia with a higher efficacy than that obtained with unselective synchronized retroperfusion. METHODS: In 42 patients with normal risk (n = 27) or high risk (n = 15) percutaneous transluminal coronary angioplasty (PTCA), alternate balloon inflations of the left anterior descending coronary artery (60 s) were either supported or not supported by selective suction and pressure-regulated retroinfusion of the anterior interventricular vein. In an additional group of 10 patients with normal risk, retroinfusion was directly compared with autoperfusion during 10 min of ischemia. RESULTS: Balloon inflations without retroinfusion resulted in a decrease of regional myocardial function in the ischemic zone to 13% of baseline. In contrast, regional myocardial function was preserved at 76% of baseline (p < 0.05) during balloon inflation supported by retroinfusion. This preservation of regional myocardial function by retroinfusion was maintained during 10 min of ischemia with at least similar efficacy compared with autoperfusion. With retroinfusion, hemodynamic variables were stabilized in normal risk and high risk patients. No complications related to the catheterization of the anterior interventricular vein using a femoral approach (95% success rate) were observed, and clinical follow-up after 3 to 6 months was uneventful with regard to the coronary intervention. CONCLUSIONS: Use of selective suction and pressure-regulated retroinfusion was feasible and safe and had a high efficacy for preserving regional myocardial function and hemodynamic variables during PTCA in normal risk and selected high risk patients.

Aged↗

The inadequacies of contemporary oropharyngeal suction.

Airway management is the highest priority in any resuscitation. Suction equipment capable of rapidly clearing the oropharynx is mandatory for airway management. Inadequate oropharyngeal suction with standard equipment may be associated with major complications in emergency airway management. We report cases that illustrate the inadequacies of standard suction equipment. Available oropharyngeal aspirators and their limitations are discussed. Recent advances in the field of oropharyngeal suction also are described.

Adolescent↗

Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis.

PURPOSE: To determine the effects of microkeratome-cutting velocities and the suction ring on corneal flap creation. SETTING: Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. METHODS: Procedures were performed under clinical settings in 65 pig eyes. Keratometric diopters (D) were measured before and after application of the suction ring. Corneal thickness was measured before and after resection cutting, and the difference was taken as flap thickness. The microkeratome was initially set at a resection thickness of 160 microns. The blade oscillation (turbine velocity) was set at 30, 35, and 42 psi. The translational velocity was arbitrarily divided into high (1 to 2 seconds), moderate (3 to 5 seconds), and low (6 seconds or more). Data were analyzed by varying the velocities consecutively. Photographs of the cut surface were acquired by scanning electron microscopy to evaluate resection morphology by comparison. RESULTS: Mean refractive powers were 39.94 D +/- 0.66 (SD) and 39.69 +/- 0.98 D before and after application of the suction ring, respectively; however, no significant difference was observed (P = .216). Lower surgeon translational velocity resulted in a significantly thicker corneal flap in 8 of the 9 paired comparisons (P < .05). Higher turbine velocity resulted in a significantly thicker corneal flap in 7 of the 9 paired comparisons (P < .05). The cut surface was smoother at higher turbine and lower translational velocity. The initial cut margin was steeper at higher translational velocity. CONCLUSIONS: The increase in intraocular pressure induced by the suction ring had no significant effect on keratometric power. At higher turbine and lower translational velocities, the corneal flap was thicker and the cut surface smoother. Higher translational velocities made the initial cut margin steeper.

Animals↗

Endotracheal suctioning in adults with severe head injury: literature review.

Endotracheal suctioning is a routine but potentially dangerous nursing procedure. The research literature documenting approaches to minimising the complications of endotracheal suctioning in adults with severe head injuries is reviewed. Hyperoxygenation, hyperventilation, hyperinflation, normal saline instillation and the effects of endotracheal suctioning on intracranial pressure and cerebral perfusion pressure are examined. Recommendations for an evidence-based endotracheal suctioning protocol are made.

Adult↗

Effects of closed suction drainage in reducing pain after laparoscopic-assisted vaginal hysterectomy.

STUDY OBJECTIVE: To estimate whether closed suction drainage of the pelvis after laparoscopic-assisted vaginal hysterectomy (LAVH) reduces the frequency and intensity of shoulder-tip, abdominal, and back pain. DESIGN: Prospective, randomized study (Canadian Task Force classification 1). SETTING: Teaching medical center. PATIENTS: One hundred sixty-four women. INTERVENTION: LAVH. MEASUREMENTS AND MAIN RESULTS: For group 1 (80 women), closed suction (Jackson-Pratt) drains were inserted into the peritoneal cavity and cul-de-sac, whereas for group 2 (84), no drains were placed. Shoulder-tip, abdominal, and back pain were evaluated by visual analog scores (VAS) 3, 24, and 48 hours after surgery. The frequency of shoulder-tip pain was significantly lower in group 1 at 24 hours (23% vs 40%, p = 0.013) and 48 hours (9% vs 21%, p = 0.024; VAS scores at 24 hrs 2.2 +/- 1.1 vs 3.8 +/- 1.3, p = 0.010; VAS scores at 48 hours 1.5 +/- 1.0 vs 2.5 +/- 1.2, p = 0.018). At 48 hours fewer women in group 1 experienced abdominal pain (31% vs 50%, p = 0.039; VAS scores 2.0 +/- 1.1 vs 4.0 +/- 1.3, p = 0.007). No statistically significant differences in frequency and VAS scores for back pain were found at any time. The quantity of oral analgesics was greater for group 2 than for group 1 (12.4 +/- 1.6 vs 9.0 +/- 1.4, p <0.001). Economic evaluation of analgesic requirements and material costs for the two groups showed that simple analgesics were more cost-effective than closed suction drainage in the treatment of pain. CONCLUSION: Closed suction drains may reduce the frequency and intensity of shoulder-tip and abdominal pain and postoperative analgesia requirements after LAVH, but simple oral analgesics are more cost effective.