Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPECIMENS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Clinicopathologic findings from lacrimal sac biopsy specimens obtained during dacryocystorhinostomy.

PURPOSE: To retrospectively review the pathologic diagnoses and clinical characteristics of patients undergoing dacryocystorhinostomy (DCR). METHODS: Specimens accessioned between 1991 and 2001 in a single ophthalmic pathology laboratory were reviewed. All of the specimens included a lacrimal sac biopsy specimen. The pathologic diagnoses were recorded. The clinical features of the patients with significant pathologic abnormalities were reviewed to determine if the pathology was suspected before or at the time of the DCR. RESULTS: There were 377 DCR specimens from 316 patients representing 1.8% of 21,018 ophthalmic pathology specimens accessioned between 1991 and 2001. Diagnoses, in decreasing order of frequency, were nongranulomatous inflammation (321, 85.1%), granulomatous inflammation consistent with sarcoidosis (8, 2.1%), lymphoma (7, 1.9%), papilloma (4, 1.11%), lymphoplasmacytic infiltrate (4, 1.1%), transitional cell carcinoma (2, 0.5%), and single cases of adenocarcinoma, undifferentiated carcinoma, granular cell tumor, plasmacytoma, and leukemic infiltrate. A total of 31 (8.2%) specimens from 25 (7.9%) of patients demonstrated significant pathology. Among 17 specimens (4.5%) from 14 patients with neoplasms whose clinical histories were available, 8 (2.1%) were not suspected before surgery. CONCLUSIONS: Nongranulomatous inflammation consistent with chronic dacryocystitis is the most common diagnosis in lacrimal sac specimens obtained at DCR. Neoplasms resulting in chronic nasolacrimal duct obstruction occurred in 4.6% of cases and were unsuspected before surgery in 2.1% of patients. We recommend pathologic examination of DCR specimens.

Adolescent↗

Comparison of first void urine and urogenital swab specimens for detection of Mycoplasma genitalium and Chlamydia trachomatis by polymerase chain reaction in patients attending a sexually transmitted disease clinic.

OBJECTIVE: The objective of this study was to compare urogenital swab specimens and first void urine (FVU) specimens from male and female patients at a sexually transmitted disease clinic for the detection of Mycoplasma genitalium and Chlamydia trachomatis infections using in-house, inhibitor-controlled polymerase chain reaction (PCR). STUDY DESIGN: Urethral swabs and FVU were collected from 1856 men and 753 women who also had a cervical swab collected. A positive diagnosis of infection was made if any 1 of the specimens tested positive and were confirmed in a second PCR assay targeting independent genes. RESULTS: M. genitalium DNA and C. trachomatis DNA were detected in 126 (6.8%) and 246 (13.3%) of the male sample sets and in 51 (6.8%) and 73 (9.7%) of the female specimen sets, respectively. Using our in-house PCR and sample preparation methods, FVU was found to be the most sensitive diagnostic specimen for both pathogens, but for optimal sensitivity, it should be supplemented with a cervical specimen in women. In a small subset of female FVUs, storage at -20 degrees C led to false-negative M. genitalium PCR results in 27% of specimens found positive when a sample preparation was performed before freezing. The age-specific prevalence of M. genitalium in men was almost constant between 18 and 45 years of age in contrast to C. trachomatis infections, which were more common in younger men. CONCLUSION: Urine appeared to be a better diagnostic specimen than the urethral swab for M. genitalium and C. trachomatis detection by PCR in this cohort of sexually transmitted disease clinic attendees but should be supplemented with a cervical specimen in women.

Adolescent↗

Type-specific detection of parainfluenza viruses by enzyme-immunoassay and radioimmunoassay in nasopharyngeal specimens of patients with acute respiratory disease.

A four-year solid phase enzyme-immunoassay (EIA) and radioimmunoassay (RIA) techniques were applied for the type-specific detection of parainfluenza type 1, 2 and 3 virus antigens in sonicated nasopharyngeal specimens of patients with acute respiratory disease. Guinea-pig antiviral immunoglobulins as the secondary antibodies, and horseradish peroxidase-labelled swine anti-rabbit immunoglobulins (EIA), or 125I-labelled sheep anti-rabbit IgG (RIA) as the indicator antibodies. A total of 174 nasopharyngeal specimens collected by mucus extractor were tested, and the results were compared with those obtained by a routinely used immunofluorescence (IF) technique. The same number of positive specimens were achieved by the EIA and the RIA and 3/4, 4/4, and 19/20 immunofluorescence (IF)-positive nasopharyngeal specimens were positive by the parainfluenza type 1, 2 and 3 immunoassays respectively. In addition, four parainfluenza type 1 and three parainfluenza type 3 virus-positive specimens were found by the immunoassays out of 146 parainfluenza IF-negative specimens. The type-specificities of the parainfluenza immunoassays were confirmed by showing that no cross-reactions occurred when purified immunizing antigens and the EIA- and RIA-positive clinical specimens were cross-tested. The results indicate that parainfluenza type-specific antigens can be detected directly in nasopharyngeal specimens by the immunoassays and the preliminary findings with a small number of positive specimens suggest that these assays have a diagnostic potential which is similar or slightly better than the IF techniques.

Acute Disease↗

A freeze-fracture replication apparatus for biological specimens.

A freeze-fracture apparatus of original design has been constructed which can be fitted onto a standard vacuum evaporator unit. In it, cell suspensions and organized tissue may be processed by inserting a sample into a cylindrical holder. By leaving a small part of the tissue protruding from the holder, pre-selected and aligned portions of the specimen can subsequently be revealed by fracture under vacuum. After rapid freezing, the specimen remains firmly attached to the inner wall of the sample holder, preventing its possible loss during fracturing. A mechanism, in the form of a double-sided converging wedge, which is operated from outside the vacuum chamber, is used to produce a fracture in the specimen. The device gently induces a fracture in the desired part of the tissue and lifts the protruding part of the specimen out of the way. In this way, reasonably flat fracture faces are produced for subsequent replication. As the fracturing mechanism comes into contact only with the outer edges of the specimen, damage and contamination liable to occur when the entire specimen is traversed by a blade, is avoided. In addition the specimen stage is surrounded by a cold metal shroud which acts as an efficient trap for contaminants. In this way, favourable vacuum conditions are produced in the vicinity of the specimen. Such effective enclosing of the specimen also facilitates controlled sublimation of the sample.

Freeze Fracturing↗

Inhibitory effects of acid water prepared by an electrolysis apparatus on early plaque formation on specimens of dentine.

The aim of this study was to compare the effects of acid water prepared by an electrolysis apparatus with placebo treatment on the ultrastructure of early plaque formed on dentine specimens attached to retainers in the oral cavity. Dentine specimens were taken from 12 healthy extracted human 3rd molars. 4 dentine specimens were placed in the both the right and left buccal flanges of retainers fabricated from self-setting acrylic resin. The retainers were placed on both maxillary buccal sites in 6 subjects. The test solution was acid water (AW) prepared by an electrolysis apparatus with a pH of 2.7 and an oxidation-reduction potential of more than 1100 mV. As a positive control, 0.2% chlorhexidine digluconate (CHX) solution was used and normal saline solution as a negative control. 4 specimens placed in the right and left retainers were randomly allocated to 4 treatments as follows: treatment A, washing with AW; treatment B, washing with CHX solution; treatment C, washing with normal saline; treatment D, no washing. Washing was carried out in a plastic beaker containing 30 ml of each solution for 30s 2X daily over a 7-day period. The specimens were then carefully removed from the retainers, the morphology and thickness of the plaque formed examined by SEM, and the developmental condition of the plaque analyzed statistically. The plaque on the specimens in treatments A and B consisted mainly of coccoid forms. Mature plaque formation with complex flora was seen on the specimens in treatments C and D. The mean thickness of the plaque deposits on the dentin specimens as measured on SEM photographs magnified 2000 times was 8.80 mm for treatment. A, while in treatment B it was 3.90 mm. Plaque thickness for treatment C was 24.97 mm, and for treatment D 25.67 mm. The thickness of plaque formed on the sectioned specimens was significantly less for treatments A and B than for treatments C and D. However, there was no statistically significant difference between treatments A and B, and between treatments C and D (p < 0.0001). The results of this short-term study indicate that AW washing has almost the same potential for inhibition of plaque formation as CHX washing, and is more effective for inhibiting plaque formation than washing with sterile saline. It is therefore concluded that AW may be useful as an anti-plaque agent.

Acids↗

Rapid semiautomated screening and processing of urine specimens.

A rapid urine culture procedure was evaluated in which positive urines were detected by using light-scatter photometry (Autobac). Specimens were analyzed at 3, 5, and 6 h. Specimens detected as positive at 3 h were then further evaluated by a direct 3-h susceptibility procedure (Autobac) and by a 4-h identification procedure (Micro-ID). Of 949 specimens, 175 had >10(5) colony-forming units per ml by colony count. Of these latter specimens, 75.4% had been detected by 3 h, and 95.4% were detected by 6 h. Of specimens positive by Autobac at 3 h, 96% (95.7%) had >10(5) colony-forming units per ml. If pure by Gram stain, those positive specimens were inoculated to direct susceptibility and identification systems. When direct Autobac susceptibilities were compared with the standard Autobac method done from the plate the following day, discrepancy rates were 1.3% very major, 2.1% major, and 7.4% total. The direct identifications were 94% (94.2%) correct when using the Micro-ID manual and a collection of octal patterns unique to this system, in which urine/broth culture inoculum was employed instead of the usual organism colony suspension. Those urine specimens negative after screening at 3 h were evaluated at 5 and 6 h, and an additional 126 specimens were detected as positive. These were then processed by routine plate inoculation, due to the limitations of the work day. By 6 h, 95.4% of specimens with >10(5) colony-forming units per ml were detected. The 4.6% false-negative results consisted of patients on antibiotics, or slowly growing bacteria suspected of being distal urethral contaminants. Thus, 83.5% of the urine cultures received by 9:00 a.m. (10.6% 3-h positives and 72.9% negative at 6 h) could be evaluated and reported within one 8-h work day.

Anti-Bacterial Agents↗

Direct immunofluorescence staining for detection of herpes simplex and varicella-zoster virus antigens in vesicular lesions and certain tissue specimens.

Direct immunofluorescence (IF) staining was compared with virus isolation for detection of herpes simplex viruses (HSV) and varicella-zoster virus (VZV) directly in clinical materials. These included 199 vesicular lesion specimens and 280 tissue specimens. Correspondence between IF and isolation results was 88% in testing for HSV in lesion specimens and 98% in testing for HSV in various tissue (mostly brain) specimens. Overall, IF was positive for 82% of the specimens in which HSV was demonstrated, and virus was isolated from 89% of the HSV-positive specimens. IF was markedly more sensitive than isolation for demonstrating VZV in lesion and tissue specimens, detecting all of the specimens positive for VZV, whereas isolation detected only 23%. IF detected VZV antigen in a number of lesion specimens taken late after onset, past the time when they would be expected to yield infectious virus. Specificity of positive IF reactions for HSV or VZV in the absence of virus isolation was supported by the facts that (i) staining was obtained with only a single, presumably homologous, immune conjugate, (ii) clinical symptoms were compatible with infection with the virus for which positive IF findings were obtained, and (iii) positive electron microscopy findings for herpesviruses or positive serological results for VZV were also obtained in some instances. Factors to be considered in achieving specificity of IF staining for these human herpesviruses are discussed.

Antigens, Viral↗

Effect of dexamethasone on detection of herpes simplex virus in clinical specimens by conventional cell culture and rapid 24-well plate centrifugation.

During a 4-month period, two methods for rapid detection of herpes simplex virus (HSV) were examined: (i) pretreatment of A549 cells with dexamethasone for conventional tissue culture (277 specimens) and (ii) 24-well plate centrifugation using A549 cells with and without dexamethasone pretreatment and staining with serotype-specific monoclonal antibodies (Syva Co., Palo Alto, Calif.) after incubation for 16 to 18 h (153 specimens). By conventional tube cell culture, both with and without dexamethasone, HSV was identified in 88 of 277 (32%) specimens. Significantly more specimens were positive for HSV at 24 h (46 versus 27 specimens) and at 48 h (a total of 72 versus 59 specimens) (P less than 0.0001) in dexamethasone-treated A549 cells. Of the 153 specimens tested by conventional culture and 24-well plate centrifugation, HSV was detected in 44 (29%) by conventional culture, and by 24-well plate centrifugation with and without dexamethasone, HSV was detected in 32 (21%) and 30 (20%) specimens, respectively. The sensitivity, specificity, and positive and negative predictive values of 24-well plate centrifugation with A549 cells for detection of HSV were 73 (71% without dexamethasone), 100, 100, and 90%, respectively. In conventional tube cell culture, pretreatment of A549 cells with dexamethasone results in more rapid detection of HSV. Centrifugal inoculation of dexamethasone-treated and untreated A549 cells in 24-well plates and staining with monoclonal antibodies after incubation for 16 to 18 h is an insensitive means to detect HSV in clinical specimens and should not replace conventional tube cell culture.

Cells, Cultured↗

Improved stool concentration procedure for detection of Cryptosporidium oocysts in fecal specimens.

Epidemiologic and laboratory data suggest that coprodiagnostic methods may fail to detect Cryptosporidium oocysts in stool specimens of infected patients. To improve the efficacy of stool concentration procedures, we modified different steps of the Formalin-ethyl acetate (FEA) stool concentration technique and evaluated these modifications by examining stool samples seeded with known numbers of Cryptosporidium oocysts. Because these modifications failed to improve oocyst detection, we developed a new stool concentration technique that includes FEA sedimentation followed by layering and flotation over hypertonic sodium chloride solution to separate parasites from stool debris. Compared with the standard FEA procedure, this technique improved Cryptosporidium oocyst detection. The sensitivities of the two concentration techniques were similar for diarrheal (watery) stool specimens (100% of watery stool specimens seeded with 5,000 oocysts per g of stool were identified as positive by the new technique, compared with 90% of stools processed by the standard FEA technique). However, the most significant improvement in diagnosis occurred with formed stool specimens that were not fatty; 70 to 90% of formed stool specimens seeded with 5,000 oocysts were identified as positive by the new technique, compared with 0% of specimens processed by the standard FEA technique. One hundred percent of formed specimens seeded with 10,000 oocysts were correctly diagnosed by using the new technique, while 0 to 60% of specimens processed by the standard FEA technique were found positive. Similarly, only 50 to 90% of stool specimens seeded with 50,000 oocysts were identified as positive by using the standard FEA technique, compared with a 100% positive rate by the new technique. The new stool concentration procedure provides enhanced detection of Cryptosporidium oocysts in all stool samples.

Acetates↗

Evaluation of an enzyme-linked immunosorbent assay for detection of Cryptosporidium spp. in stool specimens.

We evaluated a commercially produced enzyme-linked immunosorbent assay (ELISA; LMD Laboratories, Inc.) for the detection of Cryptosporidium spp. in 296 stool specimens submitted to the Mayo Clinic parasitology laboratory for routine examination. The specimens examined were fresh (4 specimens), were stored frozen at -65 degrees C (49 specimens), or were preserved in 10% formalin (243 specimens). Results were compared with those obtained by indirect immunofluorescent antibody detection (Merifluor Cryptosporidium/Giardia; Meridian Diagnostics, Inc.). One hundred of the specimens were positive by indirect immunofluorescent antibody and ELISA, while 187 were negative by both methods; 91 of these negative stool samples contained 121 parasites of 17 different species. Eight ELISA false negatives and one false positive were observed. The ELISA sensitivity was 93%, specificity was 99%, and the positive predictive value was 99%. Storage of specimens preserved in 10% formalin or frozen fresh at -65 degrees C for up to 18 months did not appear to affect the results. There was no cross-reactivity with Giardia lamblia (54 negative specimens) or with the 16 other parasites present in the ELISA-negative stool samples. The ELISA is a fast, easy-to-read, and accurate method for the detection of Cryptosporidium spp. in stool specimens.

Animals↗

Application of PCR to multiple specimen types for diagnosis of cytomegalovirus infection: comparison with cell culture and shell vial assay.

Human cytomegalovirus (CMV) is a herpesvirus that is responsible for significant morbidity and mortality in congenitally infected infants and immunocompromised patients. Antiviral therapies are available, thus making timely diagnosis of significant importance to at-risk patients. A PCR system was devised. The newly devised system, unlike previously described systems, can be applied to a wide variety of specimen types in a clinical microbiology laboratory setting. Specimens from all sites routinely accepted for CMV culture were shown to be acceptable for CMV PCR. Sensitivity and specificity were established in comparison with those of both monolayer culture and shell vial assay (SVA). The sensitivity and specificity of PCR for detection of CMV in specimens exclusive of urine and blood were 97.5 (77 of 79 specimens) and 87.2% (41 of 47 specimens), respectively. The sensitivity and specificity of PCR for urine and blood specimens were 100 (10 of 10) and 95.7% (45 of 47) and 66.7 (4 of 6) and 78.8% (41 of 52), respectively. Discrepancies of positive PCR results with negative culture or SVA results occurred for specimens flanked chronologically by other culture- or SVA-positive specimens and were likely culture failures, increasing the specificity (100%) of PCR. Discrepancies of negative PCR results with positive culture or SVA results occurred in specimens with few cells or infectious foci by SVA or culture and may represent sampling variability associated with low virus titers.

Cytomegalovirus↗

Detection of Mycobacterium tuberculosis in respiratory specimens by strand displacement amplification of DNA.

A total of 294 clinical respiratory specimens, including 75 with culture-positive results, were tested for the presence of Mycobacterium tuberculosis by strand displacement amplification (SDA) of DNA. A region of the IS6110 insertion element and an internal control sequence were amplified and then detected by a chemiluminescence assay. Receiver operator-characteristic curves were used to evaluate three methods for declaring specimens positive for M. tuberculosis. By the preferred method, SDA chemiluminescence results were converted to theoretical numbers of M. tuberculosis organisms. A positive threshold (PT) value, above which 95% of the SDA results were judged to be M. tuberculosis positive (sensitivity = 95%), was found to be 2.4 M. tuberculosis organisms per SDA reaction. The analogous PT value for 95% sensitivity on smear-positive specimens was 3.6 M. tuberculosis organisms per reaction. The PT of 2.4 M. tuberculosis organisms per reaction detected 100% of culture-positive, smear-positive specimens (sensitivity = 100%), while 95% sensitivity was achieved with a PT of 15.5 M. tuberculosis organisms per reaction. Specificities, which were calculated with respect to culture- and smear-negative specimens, ranged from 96% at a PT of 15.5 M. tuberculosis organisms to 84% at a PT of 2.4 M. tuberculosis organisms per reaction. The M. tuberculosis-negative specimens were also segregated according to whether the patients received antituberculosis chemotherapy. SDA specificity ranged from 90% (PT = 2.4 M. tuberculosis organisms) to 98% (PT = 15.5 M. tuberculosis organisms) for the M. tuberculosis-negative specimens from patients who had not received chemotherapy. SDA specificity in the M. tuberculosis-negative specimens from patients who received chemotherapy was lower (85 to 94%). This study represents the first large-scale demonstration of M. tuberculosis detection in clinical sputum specimens by isothermal DNA amplification with SDA.

Bacteriological Techniques↗

Performance of the Amplicor human immunodeficiency virus type 1 PCR and analysis of specimens with false-negative results.

Over a 4-year period, the Roche Amplicor kit was used in a United Kingdom reference laboratory for the detection or confirmation of human immunodeficiency virus (HIV) type 1 infection, particularly in infants born to HIV-infected mothers. Of 408 specimens from adults and older children tested, the 122 seronegative specimens were all Amplicor negative. Of the 286 seropositive specimens, 268 were Amplicor positive. On the basis of these results, the Amplicor assay has a specificity of 100% and a sensitivity of 93.7%. In addition, for 247 specimens from infants and young children, serological results may not have been diagnostic because of placental transfer of maternal antibodies. Forty-eight were Amplicor positive, and of the 199 Amplicor-negative specimens, 19 were assumed to be false negative on the basis of clinical data, serological markers (including p24 antigen), and/or results for previous or follow-up specimens. This represents a sensitivity of 75% for the Amplicor test for specimens from patients under 2 years of age. Of these 37 false-negative specimens plus 2 specimens from other laboratories, 31 could be characterized by amplifying extracted material from them by an in-house nested gag PCR spanning the Amplicor target region. The amplicons were sequenced and found to represent subtypes A (35.5%), B (22.6%), C (22.6%), D (16.1%), and G (3.2%). False-negative results by the Amplicor assay may be ascribed to low-target copy number, the physical behavior of one primer (SK462), and sequence variation in the target region of the other primer (SK431).

Adult↗

Clinical evaluation of the automated COBAS AMPLICOR MTB assay for testing respiratory and nonrespiratory specimens.

We evaluated the COBAS AMPLICOR PCR system (Roche Diagnostics) for the routine detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. Diagnostic culture, considered as the reference method, was performed with BACTEC, Löwenstein-Jensen, Stonebrink, and Kirchner media. Occasionally MB-Redox, ESP, or MGIT medium was also used. A total of 643 respiratory and 506 nonrespiratory specimens collected from 807 patients were investigated. Of the 95 culture-positive specimens, 80 were COBAS AMPLICOR MTB positive, and of the 1,054 culture-negative specimens, 1,044 were COBAS AMPLICOR MTB negative. After resolving discrepancies by review of the medical history, the overall sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB assay, respectively, were 83.5, 98.8, 86.7, and 98.6% compared to those of diagnostic culture. In smear-positive specimens, the sensitivity of the COBAS AMPLICOR MTB assay was 96%, versus 48% for smear-negative specimens. No significant differences in the test performance between respiratory and nonrespiratory specimens were observed. The overall inhibition rate was less than 2%, excluding stool specimens. The clear advantages of the COBAS AMPLICOR PCR system are standardized procedures and reagents for specimen processing as well as an internal control for reliable monitoring of PCR inhibitors. By simplifying the work flow through a completely automated amplification and amplicon detection procedure, the COBAS AMPLICOR PCR system proved itself as a very useful component for routine diagnostic procedures.

Automation↗

Genus level identification of mycobacteria from clinical specimens by using an easy-to-handle Mycobacterium-specific PCR assay.

An easy-to-handle Mycobacterium-specific PCR assay for detection of the presence of a wide range of mycobacterial species in clinical samples was evaluated. The performance of the genus probe was compared with the performance of probes specific for Mycobacterium tuberculosis and Mycobacterium avium and with that of standard culture. In addition, the utility of an internal control in monitoring amplification inhibitors was studied. Of 545 respiratory and 325 nonrespiratory specimens (a total of 870 specimens), 58 (6.7%) showed the presence of amplification inhibitors, as determined by a negative result for the internal control. Of these 58 specimens, 31 (53%) were stool specimens; other material, even citrate blood after lysis of erythrocytes, did not pose a problem with regard to inhibition of PCR amplification. Eighty-one of the remaining 812 specimens had a positive Mycobacterium culture result. Of these culture-positive specimens, 58 (71.6%) showed a positive result with the Mycobacterium genus-specific probe. Seventy-two samples had a positive result with the Mycobacterium-specific probe but a negative culture result. Of these 72 samples, 26 samples were regarded as true positive, either because the M. tuberculosis- or M. avium-specific probe was also positive at the same time or because other specimens from the same patient taken at the same time were culture positive. The sensitivity of the Mycobacterium-specific probe was 78.5% and the specificity was 93.5%. This study showed that pretesting of clinical specimens for mycobacteria to the genus level with a Mycobacterium-specific probe offers the routine clinical laboratory the possibility of detecting tuberculous and nontuberculous mycobacteria with one test. Furthermore, specimens testing positive with the genus-specific probe can be immediately identified with species-specific probes.

Bronchi↗

Use of an enzyme immunoassay does not eliminate the need to analyze multiple stool specimens for sensitive detection of Giardia lamblia.

The relative sensitivities of a commercially available enzyme immunoassay (EIA) (ProSpecT Giardia; Alexon-Trend Inc., Ramsey, Minn.) and conventional ovum-and-parasite (O&P) examination for the detection of Giardia lamblia in preserved stool specimens were determined. Paired stool samples collected independently within a 7-day period from 103 patients were analyzed by both methods. A total of 54 specimens from 30 patients (18 asymptomatically infected with G. lamblia and 12 with symptoms consistent with intestinal giardiasis) were determined to be positive for G. lamblia, of which 48 (88.9%) were positive by microscopy and 52 (96.3%) were positive by EIA. Both specimens submitted were positive for G. lamblia by O&P examination for 66.7% (20 of 30) of the positive patients; for 26.7% (8 of 30) a single specimen was positive by O&P examination, and for 6.7% (2 of 30) of those determined to be infected with G. lamblia, both samples were negative by microscopy. The sensitivity of conventional O&P examination was somewhat higher in symptomatically infected individuals, with 75% (9 of 12) of patients in this category having G. lamblia detected in both samples, compared with 61% (11 of 18) of asymptomatic patients. A total of 24 positive patients (80%) had G. lamblia antigen detected by EIA in both submitted samples, 4 positive patients (13.3%) had one specimen positive by EIA, and the EIA was negative in both specimens from 2 infected individuals (6.5%), the sensitivity of EIA was substantially equivalent in asymptomatic and symptomatic individuals (77 versus 83% of patients with positive results on both specimens). Although the sensitivity of EIA for the detection of G. lamblia on a single stool specimen was somewhat higher than that of conventional O&P examination in symptomatic patients (83 versus 75%), in asymptomatic patients (77 versus 61%), and overall (80 versus 67%), examination of two specimens by either EIA or microscopy was necessary to achieve a diagnostic sensitivity of greater than 90%.

Animals↗

Replicate PCR testing and probit analysis for detection and quantitation of Chlamydia pneumoniae in clinical specimens.

Nucleic acid amplification of clinical specimens with low target concentration has variable sensitivity. We examined whether testing multiple aliquots of extracted DNA increased the sensitivity and reproducibility of Chlamydia pneumoniae detection by PCR. Nested and non-nested C. pneumoniae PCR assays were compared using 10 replicates of 16 serial dilutions of C. pneumoniae ATCC VR-1310. The proportion positive versus the C. pneumoniae concentration was modeled by probit regression analysis. To validate the model, 10 replicates of 26 previously positive patient specimens of peripheral blood mononuclear cells (PBMC), sputum, or nasopharyngeal swabs (NPS) were tested. The proportion of replicates that were positive varied with the concentration of C. pneumoniae in the sample. At concentrations above 5 infection-forming units (IFU)/ml, both nested and non-nested PCR assay sensitivities were 90% or greater. The nested PCR was more sensitive (median detection, 0.35 versus 0.61 IFU/ml; relative median detection, 0.58; 95% confidence interval, 0.31 to 0.99; P = 0.04). In clinical specimens, replicate PCR detected 15 of 26 (nested) versus 1 of 26 (non-nested, P < 0.001). For PBMC specimens, testing 1, 3, or 5 replicates detected 3, 5, or 9 of 10 positive specimens, respectively. Median C. pneumoniae concentrations were estimated at 0.07 IFU/ml for PBMC and at <0.03 IFU/ml for NPS specimens. We conclude that performing 5 or 10 replicates considerably increased the sensitivity and reproducibility of C. pneumoniae PCR and enabled quantitation for clinical specimens. Due to sampling variability, PCR tests done without replication may miss a large proportion of positive specimens, particularly for specimens with small amounts of target C. pneumoniae DNA present.

Chlamydophila Infections↗

Rapid and simple method for detecting the toxin B gene of Clostridium difficile in stool specimens by loop-mediated isothermal amplification.

We applied the loop-mediated isothermal amplification (LAMP) assay to the detection of the toxin B gene (tcdB) of Clostridium difficile for identification of toxin B (TcdB)-positive C. difficile strains and detection of tcdB in stool specimens. tcdB was detected in all toxin A (TcdA)-positive, TcdB-positive (A(+)B(+)) and TcdA-negative, TcdB-positive (A(-)B(+)) C. difficile strains but not from TcdA-negative, TcdB-negative strains. Of the 74 stool specimens examined, A(+)B(+) or A(-)B(+) C. difficile was recovered from 39 specimens, of which 38 specimens were LAMP positive and one was negative. Amplification was obtained in 10 specimens that were culture negative, indicating that LAMP is highly sensitive. The LAMP assay was applied to detection of tcdB in DNA extracted by a simple boiling method from 47 of those 74 specimens, which were cultured overnight in cooked-meat medium (CMM). Twenty-two of 24 culture-positive specimens were positive for LAMP on DNA from the culture in CMM. Four specimens were culture negative but positive by LAMP on DNA from CMM cultures. The LAMP assay is a reliable tool for identification of TcdB-positive C. difficile as well as for direct detection of tcdB in stool specimens with high sensitivity. Detection of tcdB by LAMP from overnight cultures in CMM could be an alternative method of diagnostic testing at clinical laboratories without special apparatus.

Bacterial Proteins↗