Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Rotator Cuff Injuries”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

[Biomechanical tests for type II SLAP lesions of the shoulder joint before and after arthroscopic repair].

Superior labral anterior-to-posterior (SLAP) lesions can cause shoulder pain partly by causing glenohumeral instability. The purpose of this study was to examine the effect of a simulated type II SLAP lesion and subsequent repair on glenohumeral translation of the vented shoulder. In eight cadaver joints, a robotic/UFS testing system was used to measure joint translation by applying an anterior, posterior, or inferior load of 50 N to each shoulder. The "apprehension tests" for anterior and posterior instability were simulated by applying an anterior load of 50 N with an external rotation torque of 3 Nm or a posterior load of 50 N with an internal rotation torque of 3 Nm. Each loading condition was applied at 30 degrees and 60 degrees of glenohumeral abduction with a constant joint compressive load (44 N) to the intact, simulated SLAP lesion, and repaired shoulder. Repair of the type II SLAP was then performed by placing a Suretac through the labrum both anterior and posterior to the biceps anchor and testing was repeated. ANOVA was used to compare translation of the intact joint, the joint after the type II SLAP lesion had been simulated, and after repair. At 30 degrees of abduction, anterior translation of the intact vented shoulder joint from anterior loading was 18.7+/-8.5 mm and increased to 26.2+/-6.5 mm after simulation of the type II SLAP lesion ( p< or =0.05). The arthroscopic repair did not restore anterior translation (23.9+/-8.6 mm) to the same degree as the intact joint ( p> or =0.05). At 60 degrees of abduction, anterior translation of 16.6+/-9.6mm in the intact joint was not significantly increased at 19.4+/-10.1 after simulation of the type II SLAP lesion ( p=0.0527). AP loading also resulted in inferior translation. At 30 degrees of abduction it was 3.8+/-4.0 mm in the intact joint and increased to 8.5+/-5.4 mm after the type II SLAP lesion ( p< or =0.05. After repair the inferior translation decreased significantly to 6.7+/-5.3 mm ( p< or =0.05). Although inferior translations were less at 60 degrees of abduction, results were similar to those at 30 degrees after repair. There were no significant increases in translation after SI/AP combined external rotation torque or posterior-anterior combined internal rotation torque loading. In this study the repair of a type II SLAP lesion only partially restored translations to the same degree as an intact vented shoulder joint. Therefore, improved repair techniques or an anteroinferior capsulolabral procedure in addition to the type II SLAP lesion repair might be needed to restore normal joint function.

Arthroscopy↗

[MR imaging of tendon diseases. Exemplified using the examples of rotator cuff, epicondylitis and achillodynia].

Diseases of tendons have recently increased in importance. This may be due to the increasing popularity of free time sport, but also to the increasing number of treatment possibilities. The origin of damage to the tendons can be explained by a series of mechanisms, of which reduced tissue perfusion and mechanical irritation with microtrauma, which lead to degeneration, can be considered as the most important. Imaging diagnostics plays a significant role in the diagnosis and planning of the therapy of such illnesses. In addition to the conventional x-ray to determine the position of the joint and bony structures, ultrasound can be used to examine the tendons, bursae and tissue.MRI is an excellent method for examining the pathology of tendons due to its exceptional qualities for imaging tissue and joints as well as its high specificity. Using MRI, it is possible to determine the degree of morphological change, make reproducible examinations, as well as determining comorbidity factors or the reasons for the changes early in the illness. It therefore influences surgical decisions and can play a key role in the planning of operations. MRI arthography can-depending on the question-increase the diagnostic power in cases of alterations in the rotator cuff.

Achilles Tendon↗

[Intramuscular lengthening and range of motion after local tendon transfer for repair of retracted supraspinatus tendon defects. A biomechanical study].

BACKGROUND: The current cadaver study was performed to evaluate and compare infraspinatus (ISP) vs. subscapularis (SSC) tendon transfer used for the repair of a large supraspinatus (SSP) rotator cuff defect. The main outcome measures were the range of motion and intramuscular length changes during motion. METHODS: Thirteen fresh-frozen cadaver shoulders were used in the study. A supraspinatus defect extending to the apex of the humeral head (Patte size II) was created. Transosseous repair was then attempted with the ISP and with the SSC in all cases; intramuscular length changes were measured by Hall effect transducers during motion of the arm in steps of 30 degrees. RESULTS: Repair was successful in all cases when the ISP was used, while use of the SSC resulted in a successful repair in only 8 of the 13 (61.5%). Passive range of motion did not differ between ISP and SSC. ISP was shortened during flexion and abduction in contrast to the SSC that was lengthened during flexion (p<0.05) and shortened to a lesser degree (p<0.05). Length changes during rotation were not significantly different. CONCLUSIONS: In this cadaver model the ISP proved more favorable than the SSC for covering a Patte size II SSP defect if the assumption is true that lengthening of a muscle is less favorable than shortening because of the vascularization of the tendon.

Aged↗

[Rotator cuff tears: diagnosis and therapy].

Since the life span of our society is increasing and the expectation of high functional demands is growing more and more older people take part in sports activities emphasises the necessity of early diagnosis of rotator cuff lesions and their correct treatment. The goal of any diagnostic means should be a proper treatment of rotator cuff lesions according to the detected pathology. New arthroscopic techniques to surgically reconstruct rotator cuff tears have brought the operative repair techniques another step further. In cases of large and complex cuff tears the surgeon can individually select an adequate reconstruction procedure which includes anatomical-, partial-, tendon-transfer and muscle-transfer repairs. In cases of irreparable tears with cuff-tear arthropathy and consecutive superior migration of the humeral head hemiarthroplasty or the inverse deltoid prosthesis have to be considered. Based on clinical, radiological and arthroscopic findings we developed algorithms that will lead to the best suited procedure for a given lesion.

Algorithms↗

[Biomechanics of the shoulder].

The shoulder joint takes a special position among all the other joints of the human body because of its special requirements of stability and mobility. Knowledge of the biomechanics of the shoulder joint forms the basis for the development of modern concepts of reconstructive surgery and arthroplasty. Most of the biomechanical findings are the result of research performed on cadaver shoulders using increasingly sophisticated methods of measurement. These studies elucidate the interaction of the static and dynamic factors which contribute to the delicate balance of the glenohumeral joint. Recently performed research is increasingly being focussed on more detailed analyses of muscle forces and stress distribution in the subchondral bone and periarticular soft tissues. The efficiency of the computer systems now available has enabled the development of complex, virtual shoulder models and three-dimensional finite element analyses. In the future a pure mechanical understanding has to be modified to extend to a concept which includes more data obtained from living subjects, especially with regard to muscle activity under varying loads and neuromuscular feedback systems which currently are difficult to assess.

Biomechanical Phenomena↗

[MRI of the shoulder. Degenerative changes and rotator cuff tears].

MRI currently offers the best imaging information for the diagnosis of subacromial pain syndrome, rotator cuff tears and osteoarthritis of the shoulder. The excellent anatomical and tissue specific imaging allows a detailed evaluation of the rotator cuff as well as the adjacent bony structures. If the cause of subacromial pain can not be determined despite extensive clinical, sonographical and radiological examination, MRI is indicated if there is a suspected pathology of the bony structures or the glenohumeral joint that could influence the further therapeutic procedures. In addition, MRI evaluation of muscular atrophy has become an important factor for determining appropriate therapy, particularly in cases of massive rotator cuff tears.

Acromion↗

The comparison of patellar tendon-bone autografting and free flexor-tendon autografting in infraspinatus defect of the shoulder: biomechanical and histological evaluation in a sheep model.

The purpose of this study was to investigate the biomechanical and histological features of patellar tendon-bone autografting and free flexor-tendon autografting, which were fixed by two different techniques at the tendon-bone junction in reconstruction of an infraspinatus defect in sheep. Merino type sheep ( n=10) were divided into two groups. Following a defect in the infraspinatus tendon, in group I (flexor-tendon autografting) the free end of the flexor tendon was passed through the holes in the greater tuberosity for fixation. In group II (patellar tendon-bone autografting), fixation was obtained by impaction of the tibial bone plug to the greater tuberosity. Twelve weeks later, animals were sacrificed and specimens were evaluated biomechanically and histologically. Recovery of tensile mechanical properties was achieved to a level of approximately 50% in Group I and 70% in Group II at the end of the 12th week. No difference in the stiffness values was found. In group I, there was a difference between operated and contralateral (non-operated) tendons for the ultimate tensile strength values, but no difference was found in group II. Histologically, in group I, the defective area, which filled with a hypercellular connective tissue, could hardly be differentiated from the normal tendon tissue. In group II, complete incorporation of the bone block was seen in all specimens. These results suggested that patellar tendon-bone autografting is more advantageous than free flexor-tendon autografting in infraspinatus defect, providing rapid healing and better mechanical properties, especially in the early period of healing.

Animals↗

Arthroscopic biceps tendon tenodesis: the anchorage technical note.

Treatment of long head biceps (LHB) tendon pathology has become an area of renewed interest and debate among orthopaedic surgeons in recent years. The background of this manuscript is a description of biceps tenodesis which ensure continual dynamic action of the tendon which depresses the head and impedes lateral translation. A new technique has been developed in order to treat LHB tendon irreversible structural abnormalities associated with cuff rotator lesions. This technique entails the construction of a biological anchor between the LHB and supraspinatus and/or infraspinatus tendons according to arthroscopic findings. The rationale, although not supported by biomechanical studies is to obtain a triple, biomechanical effect. The first of these biomechanical effects which we try to promote through the procedure of transposition is the elimination of the deviation and oblique angle which occurs as the LHB completes its intra-articular course prior to reaching the bicipital groove. Furthermore, we have found this technique extremely useful in the presence of large ruptures of the rotator cuff with muscle retraction. The most common complication associated to this particular method, observed in less than 3%, is failed biological fixation which manifests as subsidence of the tenodesis and consequent descent of the tendon with evident aesthetic deformity.

Arthroscopy↗

Reconstruction of massive rotator cuff lesions with a synthetic interposition graft: a prospective study of 41 patients.

In the present prospective study, we report about our experience with massive rotator cuff tears treated by means of a non-resorbable transosseously fixated patch combined with subacromial decompression. Forty-one patients were followed clinically and radiographically for a mean duration of 43 months. Their mean preoperative Constant and Murley score improved (P<0.001) from 25.7 preoperatively to 72.1 postoperatively. Substantial pain relief and improvement in the performance of activities of daily living were obtained. Anatomically, the repair resulted in a mean acromiohumeral interval of 8.6 mm. At the latest follow-up, three patients presented with a new tear between the inserted mesh and the supraspinatus musculotendinous unit. Reoperations were not performed. For short-term periods, restoring a massive rotator cuff tendon defect with synthetic grafts combined with subacromial decompression can give significant pain relief and improvement of range of motion and strength with few complications.

Acromion↗

A study for evaluating the effect of the deltoid-flap repair in massive rotator cuff defects.

The repair of massive cuff defects by direct suture often is impossible. In these cases, a repair by musculo-tendineous flaps (latissimus-dorsi, pectoralis or deltoideus) is required. It was the goal of this study to evaluate the result of delta-flap repair in case of massive cuff defects with a diameter of 5 cm or more. Between 1998 and 2000 for all patients who were suffering from a massive rotator cuff tear more than 5 cm a deltoid transfer was performed. A total of 20 patients (14 male, 6 female; age: 60.9+/-8.7 years) were available for a follow-up after 47.2+/-8.0 (range, 36 to 60) month. The operation included an arthroscopic evaluation, acromioplasty with resection of the lateral clavicular end, and biceps tenodesis. The cuff defect was repaired by transfer a muscular flap from the anterior part of the deltoid (about 2 x 6 cm) into the defect. The patients subjectively rated their result-10 excellent, 9 good, and 1 poor. Preoperatively, the Constant amounted 26.3+/-5.1 points. At follow-up, the score significantly increased to 74.5+/-8.5 points. The acromiohumeral distance increased from 4.9+/-1.1 to 9.2+/-1.7 mm. In MRI examination of 11 patients all had an intact flap. Two complications (a wound hematoma and a deep infection) did not influence the result. The repair of massive rotator cuff tears by a deltoid transfer produces acceptable clinical and radiological results.

Acromion↗

Inverse knot: a personal sliding knot for arthrosopic surgery.

The development of arthroscopic reconstructive procedures has resulted in the creation of dedicated knots, sliding or not, to be used without skin incision and passed through the cannulas. Most of the recent studies are dedicated to realize and develop slip knots because they are easier and faster to use. The authors report their experience in use of a personal slip knot we called Inverse knot, due to the peculiar characteristic that is closed by the "post" strand.

Arthroscopy↗

Influence of tendon healing after arthroscopic rotator cuff repair on clinical outcome using single-row Mason-Allen suture technique: a prospective, MRI controlled study.

The reported functional results of rotator cuff repair performed arthroscopically have been good. Only little is known about the cuff integrity after arthroscopic repair and how it influences the outcome. The aim of the study is to set a baseline of what rate of healing response respectively re-tears to expect and how cuff integrity alters the outcome. Fifty-three consecutive patients with an isolated supraspinatus tendon tear were arthroscopically operated and their tendons repaired. All pre- and postoperative data were prospectively collected. At a minimum follow-up after 24 months (average 26.4 months), the integrity of the cuff was evaluated by an open magnetic resonance imaging and the patients' function and satisfaction were documented and graded to the sex- and age-related Constant-score also using a dynamometer for strength testing. The re-tear rate was 24.5% with 13 non-healed tendons. The Constant-score of all patients improved significantly. The scores of the patients with a re-tear were significantly lower than those of the patient with an intact cuff. That was due to a less good performance in strength testing. The other categories of the Constant-score did not show any differences. The age of the patients with a re-tear was significantly higher. With the exception of age, we did not find any negative prognostic factor for a re-tear, and with the exception of re-tear no other factor influenced the Constant-score. Arthroscopic supraspinatus tendon repair yields a re-tear rate of 25% which is comparable with the results of open or mini/open repair. Cuff integrity influences postoperative strength and Constant-score. Patients older than 65 years show a higher re-tear rate. Therapeutic Level IV is the level of evidence.

Aged↗

Preliminary results after rotator cuff reconstruction augmented with an autologous periosteal flap.

Periosteal augmentation of tendons in the course of refixation to bone has been shown to be a suitable method for early primarily stable osteofibroblastic integration. The aim of this study was to evaluate the clinical and radiological results of open rotator cuff reconstruction using an autologous periosteal flap augmentation technique. The research was performed as a prospective cohort study. Twenty-three prospective patients (average age 59.7 years) with degenerative rotator cuff tears were operated on with an open technique and a subtendinous periosteal flap augmentation using bioabsorbable suture anchors and a modified Mason-Allen technique. Clinical evaluation consisted of the Constant-Score and the Simple Shoulder test. Radiological evaluation included standard radiographs and magnetic resonance imaging (MRI). Twenty patients were evaluated at a mean follow-up of 14.4 months. The average Constant Score increased significantly from 51.7 to 80.9 points (p<0.05) with 12 excellent, seven good and one satisfactory result. The Simple Shoulder test showed a significant increase of an average of 4.8-10.7 questions answered with yes (p<0.05). Four patients (20%) demonstrated a retear of the tendon on postoperative MRI. Ectopic ossifications in the supraspinatus tendon were found in four patients (20%) but these had no impact on the final clinical results. Open rotator cuff repair augmented with an autologous periosteal flap shows high patient satisfaction level with low rerupture rates. Mid- and long-term results remain to be seen. The potential benefits compared with conventional open or arthroscopic rotator cuff surgery must be examined in prospective randomized studies.

Activities of Daily Living↗

Biocompatibility of a polymer patch for rotator cuff repair.

Both mechanical and biological factors influence the high re-tear rate after rotator cuff repair. Mechanical factors have largely been addressed by the introduction of better implants and modification of suture configuration, but further improvements are needed to address the often poor tissue quality of the degenerated rotator cuff tendons. Current biological solutions provide only short-term reinforcement and have been associated with pseudo-infectious reactions. This pre-clinical animal study investigates the biological response to a novel polycarbonate polyurethane patch used for tissue augmentation in a rat rotator cuff repair model. Bilateral defects were created in the supraspinatus tendons of 12 Sprague Dawley rats. One side was repaired with a patch as a tissue augmentation device. The contralateral side acted as internal control without patch augmentation. After 6 weeks the tissues were harvested and underwent histologic and histomorphometric analyses. Histological evaluation demonstrated no inflammatory reaction; histomorphometry revealed tissue ingrowth of 79.9%. In conclusion, the polycarbonate polyurethane patch for tissue extension or augmentation in rotator cuff repair has demonstrated no inflammatory response and excellent tissue integration in a rat rotator cuff repair model.

Animals↗

Arthroscopic removal of an intramedullary nail in the humerus.

The most frequent criticism of antegrade humeral nailing is its potentially deleterious effect on shoulder function owing to the trauma to the rotator cuff at the insertion point. This problem may also occur when removing an intramedullary nail from the humerus. In an effort to decrease the trauma to the rotator cuff at the nail insertion site during removal of an intramedullary nail from the humerus and to allow recovery of shoulder function as soon as possible after removal, we performed arthroscopic removal of the intramedullary nail and arthroscopic rotator cuff repair. The advantages of this method include the fact that it is a less invasive approach, which causes minimal disruption of the rotator cuff, requires fewer days in hospital, and allows simultaneous arthroscopic correction of the accompanying lesion.

Adult↗

Arthroscopic hybrid double-row rotator cuff repair.

A Beath pin is drilled on the greater tuberosity under arthroscopy using an anterior cruciate ligament guide. The suture anchor is inserted in the lateral aspect of the footprint. Sutures are then passed through the margins of the rotator cuff tear and tied with sliding knot. One strand of tied suture anchor is passed into the bony trough. One passed strand and the other strand are then tied with a non-sliding knot on the greater tuberosity. The strength of cuff fixation does not only rely on the quality of the bone, it restores the footprint contact area of rotator cuff, and reduces the use of suture anchors to the minimum in this method.

Arthroscopy↗

MRI of the postoperative shoulder.

Performing and interpreting MRI of the shoulder in patients after surgery is a difficult task. The normal anatomic features are distorted by the surgical alterations as well as the artifacts that result from metal and other materials used in the surgical procedures. This article reviews the common surgical procedures undertaken in patients with rotator cuff disease and shoulder instability, and how they affect the appearance of the relevant anatomic structures on MRI examination. It also reviews the more common causes for residual and recurrent abnormalities seen in such patients and how MRI can be used to diagnose such lesions, thus aiding the orthopedic surgeon in treating these difficult clinical problems.

Artifacts↗

Progression from calcifying tendinitis to rotator cuff tear.

This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed.

Calcinosis↗