Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Optical properties of ovalbumin in 0.130-2.50 microm spectral region.

In our continuing series of measurements of the complex index of refraction for representative samples of biological materials, we measured ovalbumin (egg albumin) over the spectral region from 0.130 (76,923 cm(-1)) to 2.50 microm (4000 cm(-1)). Films of ovalbumin suitable for optical analyses were prepared and measured in addition to solutions of ovalbumin in water. We show several examples of how the methods used in this study produced accurate results for this complex and difficult to measure material. The present work is applicable to quantitative optical studies involving ovalbumin and other serpin proteins, as well as the study of proteinaceous toxins.

Animals↗

Optical properties of Erwinia herbicola bacteria at 0.190-2.50 microm.

We measure the complex index of refraction of Erwina herbicola (also known as Enterobacter agglomerans or Pantoea agglomerans) bacteria (ATTC 33243) over the spectral region from 0.190 to 2.50 microm (4000-52,632 cm(-1)). Transmission measurements are made on solid films of E. herbicola and on suspensions of the bacteria in water. These measurements, combined with spectral reflectance and Kramers-Krönig analysis, allow the determination of the real and imaginary parts over the entire wavelength interval. Accurate and consistent results are obtained for this complex and difficult to measure material. This is part of a continuing series of measurements of the optical constants of representative biological materials that are applicable to the development of methods for detection of airborne biological contaminants, where the material under study is used as a surrogate for a pathogenic agent.

Bacteria↗

Structural properties of poly C-scleroglucan complexes.

Successive changes of solvent conditions can be used to dissociate and reassociate the triple-helical structure of (1,3)-beta-D-glucans. Ultramicroscopic techniques have revealed a blend of circular and other structures following renaturation. When this solvent exchange process is carried out in the presence of certain polynucleotides, the process creates a novel macromolecular complex. Here, we use size exclusion chromatography (SEC) to study such (1,3)-beta-D-glucan-polynucleotide complexes. Online multi-angle laser-light scattering (MALLS) and refractive index (RI) detectors allowed determination of molecular weight and radius of gyration of the molecules. An ultraviolet (UV) detector allowed specific detection of the polynucleotide. The poly-cytidylic acid (poly C) shifted to coelution with the linear fraction of the scleroglucan following the renaturation of poly C-scleroglucan blends, indicating that poly C is incorporated in linear, but not in circular, structures of scleroglucan. This conclusion was consistent with AFM topographs that revealed a decreased fraction of circular structures upon addition of poly C during the renaturation process. The combined information about radius of gyration (R(g)) and molecular weight (M(w)) allowed us to conclude that the poly C-scleroglucan complexes are more dense and have a higher persistence length than linear scleroglucan triple helixes. The experimentally determined mass per unit length was used as a basis for elucidating possible molecular arrangements within the poly C-scleroglucan complex.

Biopolymers↗

Optical waveguide lightmode spectroscopy (OWLS) to monitor cell proliferation quantitatively.

The use of microscopic observations used for in situ monitoring of cell proliferation in the production of epidermal autografts is not satisfactory. In particular, the identification of the projected cell area from microscopic pictures by image analysis (IA) depends on intensity edges and level of contrasts and is thus limited to subconfluent cultures. Some of these problems can be solved by using optical waveguide lightmode spectroscopy (OWLS), which measures the effective refractive index of a thin layer above an Si(Ti)O(2) waveguide surface. In this study the use of OWLS to monitor cell adhesion, spreading, and growth was studied. The sensitivity of the method was investigated by using three different cell lines, two fibroblasts and one hepatoma cell line. Cell proliferation of two strains of fibroblasts and hepatoma cells was monitored up to 2 days with the OWLS. In parallel, cell density was determined at different time points microscopically using an additional window in the measuring chamber. The cell density of fully spread cells ( approximately 4 h after attachment) was found to be proportional to the OWLS signal. In long-term cultures the influence of the cell density from single cells to confluent cell cultures upon the OWLS signal was investigated. The exponentially growing number of hepatoma resulted in a linear increase of the sensor signal. Due to this and to the fact that the proliferating cells exhibit contact inhibition, it was concluded that the cell contact area must decrease exponentially. The results show the strength of OWLS for monitoring the adhesion and proliferation of anchorage-dependent cells in applications where an on-line indicator of the total biomass is needed. Additionally, OWLS provides metabolic information through detection of the cell mass in close contact with the waveguide.

3T3 Cells↗

Optical and mathematical corrections of micropipette measurements of red blood cell geometry during anisotonic perifusion.

Accurate knowledge of red blood cell (RBC) membrane surface area and cellular volume is critical to understanding the geometric factors that affect RBC deformability. A useful method to determine RBC geometry is via micropipette aspiration in which the cell partially enters the tip of a glass pipette with a diameter of about 2 microns. Measurement of the cell while in the pipette allows calculation of cell geometry, but such measurements are subject to several artifacts. Herein, we analyze the effects of three artifacts on calculated RBC geometry during experimental osmotic manipulation. 1) The pipette internal diameter, as measured optically, requires correction for refractive index and focusing errors; 2) the pipette barrel is tapered rather than cylindrical; 3) the observed RBC outline is affected by a diffraction phenomenon. These optical and mathematical errors were all found to influence the calculated RBC geometry; both absolute values and relative changes during osmotic manipulation were affected. For RBC in isotonic medium, use of the above corrections significantly (p < 0.001) reduced the calculated area by 3.7%, the volume by 7.0%, and the minimum cylindrical diameter by 3.9%. The calculated membrane area dilation for cells exposed to hypotonic media was also significantly reduced; at 200 mOsm, the dilation was 2.8% +/- 0.2% without correction vs. 1.5% +/- 0.2% when all corrections were employed (p < 0.01). We therefore suggest that micropipette aspiration of RBC requires use of these correction techniques to obtain accurate values for RBC geometry and that such correction methods are of particular importance when RBC of different sizes are compared.

Adult↗

Refractive index measurement in viable cells using quantitative phase-amplitude microscopy and confocal microscopy.

BACKGROUND: The refractive index (RI) of cellular material provides fundamental biophysical information about the composition and organizational structure of cells. Efforts to describe the refractive properties of cells have been significantly impeded by the experimental difficulties encountered in measuring viable cell RI. In this report we describe a procedure for the application of quantitative phase microscopy in conjunction with confocal microscopy to measure the RI of a cultured muscle cell specimen. METHODS: The experimental strategy involved calculation of cell thickness by using confocal optical sectioning procedures, construction of a phase map of the same cell using quantitative phase microscopy, and selection of cellular regions of interest to solve for the cell RI. RESULTS: Mean cell thickness and phase values for six cell regions (five cytoplasmic and one nuclear) were determined. The average refractive index calculated for cytoplasmic and nuclear regions was 1.360 +/- 0.004. The uncertainty in the final RI value represents the technique measurement error. CONCLUSIONS: The methodology we describe for viable cell RI measurement with this prototype cell has broad generic application in the study of cell growth and functional responses. The RI value we report may be used in optical analyses of cultured cell structure and morphology.

Cell Survival↗

The effect of certain antibiotics on the keeping quality of bolti fish (Tilapia nilotica).

Fresh bolti fish (Tilapia nilotica), caught in the river Nile was immersed in 10 and 20 ppm tetracycline (TC) solutions for 10 and 15 min respectively and in 500 and 1000 R.U. nisin/g fish for 20 and 30 min respectively. Total volatile bases (TVN) showed in both fish treated with TC and nisin a slow increase at the first stage and after that a fast increase. There was an increase in trimethylamine (TMA) during the storage period, but the fish treated with TC and nisin contained less TMA than the control. Starting from 6 h the residual TC decreased gradually till the third day, when it disappeared completely. There is no change in pH values in both control and treated fish. Optical density (OD) of gills extract increased gradually as the storage period progresses. The treated fish showed lower OD values than the controls. The refractive index of muscle fluids and the OD of muscle extract showed no significant differences between the control and treated fish.

Animals↗

Thin film rheology and lubricity of hyaluronic acid solutions at a normal physiological concentration.

Using a surface forces apparatus to measure forces, and optical (multiple beam) interferometry to measure surface shapes and separations (to +/-1 A), the normal, viscous, and shear (lubrication) forces between smooth mica surfaces in aqueous hyaluronic acid (HA) solutions were measured. The experimental conditions of loading pressures, pH, and HA concentration were set to closely correspond to physiological human knee-joint conditions. From the force and optical (refractive index) measurements, it was concluded that, like other negatively charged polyelectrolytes, HA does not naturally adsorb on the mica surface which is hydrophilic and weakly negatively charged at physiological conditions: the polymer solution exhibits the bulk viscosity (22.5 +/- 1.5 cP) for films thicker than about 0.4 miccrom of the polymer, whereas for thinner films, the viscosity decreases monotonically toward the value of the pure electrolyte solution (1 cP) as HA is extruded from between the surfaces. This is indicative of a repulsive "depletion" interaction of HA with each mica surface and to a weakly attractive polymer-mediated force between the two surfaces. Thus, free HA in synovial fluid is not expected to act as a good "boundary lubricant." Relaxation measurements on approaching and receding surfaces in HA solutions were also performed, and it is shown that the presence of HA in the bulk solution can improve "hydrodynamic" modes of lubrication, for example, by assuaging the compression stroke. The study includes information that is beneficial to researchers working with biomaterials viscosupplementation devices.

Adsorption↗

Color characteristics of low-chroma and high-translucence dental resin composites by different measuring modes.

The objective of the described research was the evaluation of the effects of the differences in the color-measuring geometry (SCE, SCI) and the standard illuminant on the color and color change after polymerization and thermocycling of resin composites. White, translucent, and conventional shades of two brands of resin composites were measured before and after polymerization and after thermocycling according to the CIE L*a*b* color scale on a reflection spectrophotometer with SCE and SCI geometry under the standard illuminants A, D65, and C. Under both SCE and SCI modes, the color differences (DeltaE*) of specimens between the values measured under illuminants A and D65 or A and C were larger than those between D65 and C in unpolymerized, polymerized, and thermocycled conditions. With SCE geometry, DeltaE* after polymerization of the white shade group was 8.7-9.8 under D65, and was higher than the conventional shade group (p < 0.05) in both materials. With SCE geometry, DeltaE* between polymerized and thermocycled white, translucent shade was 4.4-7.1 under D65. With SCI geometry, the results were in general agreement with those of SCE mode. After polymerization, DeltaE* measured under illuminant A was generally higher than that under D65 or C (p < 0.01). After thermocycling, the color change was different depending on the color-measuring geometry and standard illuminant.

Barium↗

A comparative evaluation of the biostability of a poly (ether urethane) in the intraocular, intramuscular, and subcutaneous environments.

A transparent poly (ether urethane) (PEU) was considered for use as a foldable intraocular lens material. The PEU was found to possess excellent mechanical, optical, and surface characteristics for this application. In vitro hydrolytic and ultraviolet aging studies suggested the PEU to be tolerant to conditions simulating 3-10 years of normal intraocular exposure. Different behavior was obtained, however, from intraocular and subcutaneous implantation of the PEU. After 6 months of intraocular exposure in the feline model, prototype PEU lenses had lost most or all of their optical resolving power. SEM analysis demonstrated scattered pitting and cracking on the lens surfaces. Degradation was found to be more extreme after as little as 30 days of subcutaneous exposure in rabbits. Severe pitting over the entire surface of implanted flat PEU specimens was observed by SEM. Macroscopic examination showed the samples to be frosty in appearance. It was postulated that the subcutaneous implant environment provides an accelerated in vivo model for materials intended for intraocular use. A minimum acceleration of 6-10x was estimated on a preliminary basis. The PEU studied here was found to be unsuitable for use as a foldable intraocular lens material.

Animals↗

Shadowing and enhancement in ultrasonic echograms by reflection and refraction.

The action of reflection and refraction in producing shadows and enhancement in ultrasonic echograms behind cystic structures is well known, but the physical explanations usually used are incomplete. In this paper the emergent beam patterns for a number of cases are plotted and this data used to explain the shadows and enhancement observed. Cases are also illustrated of echoes displayed incorrectly within the shadow region and of reflectors within the shadow region displayed elsewhere. The use of the echographic appearances to assess the velocity of propagation in cystic structures is described.

Image Enhancement↗

Defocusing microscopy.

Transparent objects (phase objects) are not visible in a standard brightfield optical microscope. In order to see such objects the most used technique is phase-contrast microscopy. In phase-contrast microscopy the contrast observed is proportional to the optical path difference introduced by the object. If the index of refraction is uniform, phase-contrast microscopy then yields a measure of the thickness profile of phase objects. We show that by slightly defocusing an optical microscope operating in brightfield, phase objects become visible. We modeled such an effect and show that the image contrast of a phase object is proportional to the amount of defocusing and proportional to the two-dimensional Laplacian of the optical path difference introduced by the object. For uniform index of refraction, defocusing microscopy then yields a measure of the curvature profile of phase objects. We extended our previous model for thin objects to thick objects. To check our theoretical model, we use as phase objects polystyrene spherical caps and compare their curvature radii obtained by defocusing microscopy (DM) to those obtained with atomic force microscopy (AFM). We also show that for thick curved phase objects one can reconstruct their thickness profiles from DM images. We illustrate the utility of defocusing microscopy in biological systems to study cell motility. In particular, we visualize and quantitatively measure real-time cytoskeleton curvature fluctuations of macrophages (a cell of the innate immune system). The study of such fluctuations might be important for a better understanding of the engulfment process of pathogens during phagocytosis.

Animals↗

2,2'-thiodiethanol: a new water soluble mounting medium for high resolution optical microscopy.

The use of high numerical aperture immersion lenses in optical microscopy is compromised by spherical aberrations induced by the refractive index mismatch between the immersion system and the embedding medium of the sample. Especially when imaging >10 micro m deep into the specimen, the refractive index mismatch results in a noticeable loss of image brightness and resolution. A solution to this problem is to adapt the index of the embedding medium to that of the immersion system. Unfortunately, not many mounting media are known that are both index tunable as well as compatible with fluorescence imaging. Here we introduce a nontoxic embedding medium, 2,2'-thiodiethanol (TDE), which, by being miscible with water at any ratio, allows fine adjustment of the average refractive index of the sample ranging from that of water (1.33) to that of immersion oil (1.52). TDE thus enables high resolution imaging deep inside fixed specimens with objective lenses of the highest available aperture angles and has the potential to render glycerol embedding redundant. The refractive index changes due to larger cellular structures, such as nuclei, are largely compensated. Additionally, as an antioxidant, TDE preserves the fluorescence quantum yield of most of the fluorophores. We present the optical and chemical properties of this new medium as well as its application to a variety of differently stained cells and cellular substructures.

Animals↗

Solubilization of hydrophobic drugs in octanoyl-6-O-ascorbic acid micellar dispersions.

Alkanoyl-6-O-ascorbic acid esters are easily obtained from vitamin C, and produce self-assembled aggregates in water solutions, with an inner hydrophobic pool surrounded by an external hydrophilic shell. Compared to ascorbic acid, their solubility in oils and fats is greatly enhanced, while the peculiar antioxidant activity is retained in the polar head groups of such surfactants. In virtue of their amphiphilic nature, ascorbic acid-based supramolecular systems can dissolve relevant amounts of hydrophobic, poorly water soluble chemicals such as drugs, vitamins, and so on, and at the same time they provide a suitable shield against oxidative deterioration of valuable materials. In this article we report our study on the self-assembling properties of octanoyl-6-O-ascorbic acid in water, and on the solubilization of some lipophilic molecules in its dispersions.

Antioxidants↗

Optical characterization of a low solubility organic compound.

The X, Y, and Z principal vibration directions along with the principal refractive indexes, optic angle, optical sign, birefringence, optical orientation, and crystal system for the low solubility compound 5-(tetradecyloxy)-2-furancarboxylic acid were determined with a polarizing microscope and spindle stage. The X and Z principal vibration directions are not coincident with the a and c crystallographic axes; however, the Y direction is considered to be coincident with the b axis. Therefore, the crystal is assigned to the monoclinic crystal system. The bladed/lath-shaped crystals rest on one of the two large orthopinacoid (100) faces and present the microscopist with a single plane of optical symmetry. A beta refractive index of 1.555 is observed with the crystal axis of elongation parallel to the polarizer, and a gamma of 1.600-1.660 is observed in the contiguous extinction position. Determination of the optic angle principal vibration directions, and principal refractive indexes was facilitated by mounting the crystals on a spindle stage for rotation about the b crystallographic axis (optic normal).

Crystallization↗

Determination of pharmaceutical compounds in animal feeds using high-performance liquid chromatography with refractive index detection.

Liquid chromatography with refractive index (RI) detection has been found to be very useful for the determination of pharmaceutical compounds in animal feeds. The RI detection can be especially valuable for the determination of compounds that have low ultraviolet-visible (UV-VIS) absorptions or absorb only at low UV wavelengths. The effect of the extraction solvent polarity, pH, and ion pairing reagents on feed extractables, as observed by RI and UV detection, has been studied. The RI detection typically shows less interference from the feed matrix than UV detection, particularly with polar extracting solvents. Changes in the extracting solvent pH do not significantly affect the response of feed extractables to RI or UV detection. With RI detection, analytes have been determined in feed at levels of 200 ppm with little or no cleanup.

Animal Feed↗