Computed direct magnification radiography of bone tumors.

The purpose of this study was to assess the diagnostic performance of computed direct magnification radiography in diagnosing bone tumors as compared with conventional radiography. Ninety-one patients with primary bone tumors and tumor-like lesions were radiographed with conventional and magnification techniques. All radiographs were analyzed by one orthopedic surgeon and two radiologists and the findings were correlated with histopathology. Two microfocal X-ray units were used for computed direct magnification radiography with a focal spot size of 20-130 microm. Using magnification versus conventional radiography, the diagnosis of benign and malignant lesions as well as the individual tumor diagnosis was obtained with higher accuracy (85% versus 71% and 69% versus 51%, respectively, P<0.01). Margins of destruction, periosteal reactions, and matrix patterns were evaluated with higher accuracy by all observers (P<0.01). We conclude that computed direct magnification radiography may improve evaluation and diagnosis of bone tumors.

Adult↗

Advanced multiple beam equalization radiography (AMBER) in the detection of diffuse lung disease.

To evaluate the effects of scanning equalization radiography (SER) on the detection of diffuse lung disease a clinical comparison between an Advanced Multiple Beam Equalization Radiography (AMBER) unit and conventional chest radiography was performed. Even though the overall detection of focal pulmonary lesions with the AMBER unit has been shown to be significantly higher than with conventional radiography because of the improved demonstration of the costophrenic and retrocardiac regions, the utility of AMBER in the demonstration of diffuse lung disease has not been established. Twenty-one patients with diffuse lung disease (fibrosing alveolitis or sarcoidosis) and six patients with no pulmonary disease had high kVp frontal and lateral chest radiographs on both an AMBER unit and a conventional chest stand. The pooled results of five observers using Receiver Operating Characteristic (ROC) analysis indicate that there is a slight improvement but no statistically significant difference in observer performance between AMBER (Area under the ROC curve AZ = 0.934) and conventional radiography (AZ = 0.868) in the task of detecting diffuse lung disease.

Evaluation Studies as Topic↗

Differentiation of malignant from benign solitary pulmonary lesions using chest radiography, spiral CT and HRCT.

OBJECTIVE: The aim of this prospective study was to summarize all of the qualitative and quantitative imaging criteria for the differentiation of solitary pulmonary lesions (SPLs) as malignant (MSPLs) or benign (BSPLs) described in the literature and to critically analyze the different characteristics in order to evaluate their clinical importance and usefulness as criteria for a discrimination during the primary diagnostic assessment of SPLs using chest radiography, spiral computed tomography (SCT) and high-resolution computed tomography (HRCT). MATERIALS AND METHODS: SPLs were examined, evaluated and then completely removed by surgery in 104 consecutive patients (MSPLs n=81, BSPLs n=23). No SPL was excluded by size. Chest radiography was performed with frontal and lateral views, SCT was carried out with a slice thickness of 8 mm and HRCT with a slice thickness of 1 mm and a 12-cm field of view. RESULTS: All the characteristics which enabled a reliable differentiation of MSPLs from BSPLs were characteristics which were observed significantly more frequently in MSPLs than BSPLs. Useful characteristics for the differentiation of MSPLs from BSPLs (1) using chest radiography were the indistinct edge (P<0.0001) and a ground-glass opacity of the lung parenchyma adjacent to the SPL (P<0. 05); (2) using SCT the presence of spicules (P<0.0005), the vessel sign (P<0.0005), necrotic areas (P<0.001), spicules extending to the visceral pleura (P<0.005), circumscribed pleural thickening (P<0. 005), inhomogeneity (P<0.01), a ground-glass opacity of the lung parenchyma adjacent to the SPL (P<0.01), the lesion density (P<0.05), pleural retraction (P<0.05) and the bronchus sign (P<0.05); and (3) using HRCT the presence of spicules (P<0.00005), spicules extending to the visceral pleura (P<0.0005), the vessel sign (P<0.0005), pleural retraction (P<0.001), circumscribed pleural thickening (P<0. 001), the bronchus sign (P<0.005), a ground-glass opacity of the lung parenchyma adjacent to the SPL (P<0.01), the lesion density (P<0.05) and the length of spicules (P<0.05). Using any one of the characteristics with a significance level of P<0.01, the identification of MSPLs (1) using chest radiography showed a sensitivity of 64.2% and a specificity of 82.6% (accuracy of 68.3%); (2) using SCT a sensitivity of 88.9% and a specificity of 60.9% (accuracy of 82.7%); and (3) using HRCT a sensitivity of 91.4% and a specificity of 56.5% (accuracy of 83.7%). CONCLUSIONS: Using chest radiography, SCT and HRCT, a precise morphological assessment of the periphery of the pulmonary lesion and the adjacent visceral pleura is necessary to distinguish MSPLs from BSPLs. In this respect SCT and HRCT are useful in differentiation of MSPLs from BSPLs. However, metastases strongly resembled benign lesions in terms of size and edge type and chronic inflammatory pseudotumors as a group mimic MSPLs.

Diagnosis, Differential↗

Diagnostic radiography in rheumatoid arthritis: benefits and limitations.

In the light of more modern techniques such as sonography and magnetic resonance imaging, the reader may well ask if plain radiography has still a role in the diagnostic work-up of rheumatoid arthritis. However, in daily routine, the value of diagnostic radiography in support of the clinical and laboratory diagnosis of rheumatoid arthritis is unrivaled. It allows differentiation from other joint diseases, such as osteoarthritis or crystal arthropathies, when the ARA criteria are not conclusive for the diagnosis of rheumatoid arthritis. Further, plain radiography is part of the basic documentation of the disease in measuring disease progression. Therapeutic decisions, such as systemic versus local therapy, and selection of drugs, as well as the form of local therapy, are heavily dependent on radiographs. However, the limitations of radiography in evaluating disease progression have to be recognized. Ultrasonography, as a 'bedside method', and MRI are indispensable adjuncts to radiography, because they are superior in detecting synovitis, early forms of cartilage damage as well as bone reaction such as erosions and cysts. A superior assessment of the degree of synovial changes is also possible with MRI.

Arthritis, Rheumatoid↗

A survey of pressure ulcer education within pre-registration radiography courses.

The prevention of pressure ulcers and the management of people with pressure ulcers is multi-disciplinary, though in many places it is considered a nursing problem. Radiography environments are a potential cause of pressure ulcers. This paper describes the results of a survey of pre-registration radiography education institutions regarding the education provision on the prevention of pressure ulcers within radiography environments. The survey comprised two parts--a desk top review of course prospectuses and a postal questionnaire. Course prospectuses for 23 of the 24 institutions were examined for specific mention of prevention and management of pressure ulcers but none was found. All 24 institutions in the United Kingdom were invited to respond to a questionnaire survey, and 14 replied (58% response rate). Responses covered both diagnostic and therapeutic radiography programmes. Nine institutions specifically identify teaching on pressure ulcers, with the majority of education appearing in year 1 of the course, with some courses providing further material later in the programme. The survey confirms anecdotal evidence reported in a previous study that radiographers have little training in the prevention and management of patients at risk of developing pressure ulcers during radiographic procedures. Thirteen out of 14 institutions stated that no final year student project had considered the prevention and management of pressure ulcers in radiography environments.

Adult↗

Digital radiography in the evaluation of oesophageal motility disorders.

AIMS: To develop a simple technique for examination of the oesophagus by digital radiography and to assess its role in the evaluation of motility disorders of the oesophagus. MATERIALS AND METHODS: Forty-nine patients and 44 control subjects underwent manometry and digital examination of the oesophagus. The digital study consisted of two parts: firstly examination of the pharynx and cervical oesophagus using 15 ml of fluid barium in anterio-posterior (AP) and lateral views, with image acquisition of four frames/s for 2 s. Secondly, examination of the thoracic oesophagus and oesophagogastric junction using 25 ml of barium in two prone oblique and one supine AP series, with image acquisition of one frame/s for 20 s. Oesophageal transit time (OTT) was measured in each case. Abnormal or non-peristaltic contractions were described regarding their morphology, time of visualization and length. The presence or absence of hiatal hernia, reflux or any associated organic lesions was noted. RESULTS: Digital radiography diagnosed 14 cases of achalasia and 28 cases of non-specific oesophageal motility disorder (NOMD). Normal OTT was 11.95 +/- 1.304 s. The OTT was prolonged (16 s or more) in all patients except five; four of these were cases of NOMD. Abnormal contractions were classified into circular and longitudinal types. The circular non-obliterating type was commoner. Achalasia was diagnosed in all cases, as failure of relaxation of the inferior oesophageal sphincter was always present and easily depicted by digital radiography. Abnormal contractions in the body of the oesophagus were elicited in 57% of cases of achalasia. The sensitivity of digital radiography in detecting oesophageal motility disorders was 85.7% based on the presence of abnormal contractions and 91.6% by eliciting a prolonged OTT. CONCLUSIONS: Examination of the oesophagus by digital radiography is simple, non-invasive, reproducible, rapid and without discomfort to patients. It allows the diagnosis of motility disorders of the oesophagus by detecting abnormal contractions and/or prolonged OTT and showed any associated organic lesions.Aly, Y. A. (2000). Clinical Radiology 55, 561-568.

Adolescent↗

[Compression-free biplanar radiography of the breast specimen with a specimen device].

PURPOSE: To develop a device for specimen radiography of impalpable breast lesions with microcalcifications in order to perform compression-free radiography in two planes and to document the original orientation of the specimen on the radiographic film. MATERIALS AND METHODS: A curved plate with its radius equal to the film-focus-distance enables specimen radiography without compression and with minimizing artifacts induced by beam divergency. Adjustable markers can document the topographic orientation of the specimen on the radiographic film. RESULTS: The presented specimen device for biplanar radiography avoids interfering compression artifacts for both radiologist and pathologist. Documenting the original topographic orientation of the specimen on the film helps to guide the surgeon in cases requiring further resection. DISCUSSION: Biplanar specimen radiography without compression of the specimen measures the distance of microcalcifications to the margin of the resected tissue more accurately and thus provides a better basis for planning any necessary additional resection.

Breast↗

Prospective randomised trial of computer-aided diagnosis and contrast radiography in acute small bowel obstruction.

OBJECTIVE: to compare the ability of computer-aided diagnosis and contrast radiography for the diagnosis of acute mechanical small bowel obstruction. DESIGN: Prospective randomised trial. SETTING: Kaunas University of Medicine, Lithuania. SUBJECTS: 80 patients with small bowel obstruction with no clinical evidence of strangulation who were randomised into two groups (n = 40 in each) to be investigated by computer-aided diagnosis and contrast radiography. INTENVENTIONS: 37 patients required operation (46%). MAIN OUTCOME MEASURES: specificity, sensitivity, false positive and negative predictive values of the 2 methods; time necessary to make the diagnosis; and morbidity and mortality. RESULTS: The specificity, sensitivity, positive and negative predictive values in the diagnosis of complete acute small bowel obstruction for the computer-aided group were 100%, 87.5%, 100% and 92.3%, and for the contrast radiography group 100%, 76.9%, 100% and 90%, respectively. The mean time period for making the diagnosis was 1 hour in the computer-aided group and 16 hours in the radiography group (p < 0.001). The overall mortality was 3% and morbidity 9%. CONCLUSION: Computer-aided diagnosis had no significant advantage over contrast radiography in the accuracy of diagnosis of the character of small bowel obstruction. However, significantly less time was needed to make the diagnosis in the computer-aided group.

Adolescent↗

Computed radiography for breast cancer.

In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses.

Breast Neoplasms↗

Effective dose equivalent and associated risks from mass chest radiography in Kuwait.

The number of x-ray examinations performed on persons undergoing mass chest radiography in Kuwait reached a maximum of 1.858 X 10(5) in 1982 with miniature radiography (70 mm) claiming more than 90% of the total number and the rest done with the large film technique. The annual prevalence of asymptomatic tuberculosis patients diagnosed by x rays, as reported by the project statistics, does not, in our opinion, justify exposing such a large population. In this paper, the effective dose equivalent is calculated from both miniature and large film mass chest radiography as applied in Kuwait. The values obtained are 283 mu Sv and 35.5 mu Sv, respectively. These figures yield calculated risks of fatal malignancies per examination of 3.37 X 10(-6) and 0.422 X 10(-6), respectively. The annual collective effective dose equivalent to the population undergoing mass chest radiography in Kuwait during the 7 y 1977-1983 is found to vary between 38-48 man-Sv. These figures are used to calculate an average of 0.5 additional cases of fatal malignancies per year, or about 12 excess fatalities in the forthcoming 25-y period if the number of mass chest x-ray examinations stays at its existing level. A total of 98% of these calculated excess fatalities result from the predominant technique, miniature radiography.

Adolescent↗

Measurement of femoral anteversion by biplane radiography and computed tomography imaging: comparison with an anatomic reference.

RATIONALE AND OBJECTIVES: The ability of biplane radiography and standard computed tomography (CT) imaging techniques to measure accurately the human femoral anteversion was evaluated and compared with an anatomic reference: the osteometric method. METHODS: Femoral anteversion of 10 normal adult cadaveric human femora were determined using a standardized anatomic measurement method (the anatomic reference) and the 2 selected common imaging techniques (biplane radiography and CT). RESULTS: On average, anteversion measurements using biplane radiography were 21/2 times greater in magnitude than measurements using the anatomic reference (absolute mean difference, 13.5 degrees; P = 0.004). In contrast, the discrepancy between CT and anatomic reference measurements was notably less and not statistically significant (absolute mean difference, 2.8 degrees; P = 0.351). In addition, biplane radiography demonstrated greater inter- and intrarater variability than CT imaging for repeated measurements of the same bone specimens. CONCLUSIONS: Compared with the anatomic reference, CT imaging was an accurate and valid technique for measuring the femoral anteversion. In contrast, biplane radiography demonstrated significant inconsistencies in the measurement of this anatomic parameter.

Adult↗

Dorsolateral subluxation of hip joints in dogs measured in a weight-bearing position with radiography and computed tomography.

OBJECTIVE: develop a radiographic procedure to measure dorsolateral subluxation (DLS) of the femoral head in canine coxofemoral (hip) joints in a weight-bearing position. STUDY DESIGN: DLS measured on a radiographic projection was compared with DLS measured on computed tomography (CT) images of hip joints in a weight-bearing position. ANIMALS: A total of 24 dogs of varying ages were examined including Labrador retrievers, greyhounds, and Labrador-greyhound crossbreeds. METHODS: Anesthetized dogs were placed in sternal recumbency in a kneeling position in a foam rubber mold. The stifles were flexed and adducted with the femora perpendicular to, and in contact with, the table. To test for DLS, dogs were imaged in this weight-bearing position (DLS test) with routine radiography and CT. For each hip, the DLS score was determined by measuring the percentage of the femoral head medial to the lateralmost point of the cranial acetabular rim on the dorsoventral radiographic projection and the lateralmost point of the central, dorsal acetabular rim on the CT image. Higher DLS scores indicated better coverage of the femoral head by the acetabulum. DLS scores were compared with the distraction index (DI) by grouping joints according to their probability of developing osteoarthritis (OA) as predicted by the DI. RESULTS: The DLS score in the new position ranged from 29% to 71% for radiography and 15% to 59% for CT. Joints classified as OA unsusceptible had a mean score of 64% +/- 1.5% for radiography and 55% +/- 0.8% for CT (n = 10); hip joints having a high probability of developing OA had a score of 39% +/- 2.6% for radiography and 26% +/- 1.9% for CT (n = 8). When the DLS test was repeated on the same dogs at a different time, the intraclass correlation coefficient for the DLS score on the radiographs was 0.85 (left hip) and 0.89 (right hip). There was a strong correlation (r = .89 for both hips) between the DLS score measured on the weight-bearing radiograph and the CT image. A strong correlation also was observed between the DLS score and the DI (r = -.87). The DLS scores for OA unsusceptible joints and joints with a high probability of developing OA were significantly different (P < .05). CONCLUSIONS AND CLINICAL RELEVANCE: The DLS test can be performed with CT or routine radiography to measure variable amounts of DLS in weight-bearing hip joints oriented similarly to those of a standing dog. After additional long-term follow-up studies evaluating the development of OA and breed effects are performed, the DLS method may prove useful in studies of normal and abnormal hip joint development related to canine hip dysplasia.

Animals↗

Imaging properties of digital magnification radiography.

Flat panel detectors exhibit improved signal-to-noise ratio (SNR) and display capabilities compared to film. This improvement necessitates a new evaluation of optimal geometry for conventional projection imaging applications such as digital projection mammography as well as for advanced x-ray imaging applications including cone-beam computed tomography (CT), tomosynthesis, and mammotomography. Such an evaluation was undertaken in this study to examine the effects of x-ray source distribution, inherent detector resolution, magnification, scatter rejection, and noise characteristics including noise aliasing. A model for x-ray image acquisition was used to develop generic results applicable to flat panel detectors with similar x-ray absorption characteristics. The model assumed a Gaussian distribution for the focal spot and a rectangular distribution for a pixel. A generic model for the modulated transfer function (MTF) of indirect flat panel detectors was derived by a nonlinear fit of empirical receptor data to the Burgess model for phosphor MTFs. Noise characteristics were investigated using a generic noise power spectrum (NPS) model for indirect phosphor-based detectors. The detective quantum efficiency (DQE) was then calculated from the MTF and NPS models. The results were examined as a function of focal spot size (0.1, 0.3, and 0.6 mm) and pixel size (50, 100, 150, and 200 microm) for magnification ranges 1 to 3. Mammography, general radiography (also applicable to mammotomography), and chest radiography applications were explored using x-ray energies of 28, 74, and 120 kVp, respectively. Nodule detection was examined using the effective point source scatter model, effective DQE, and the Hotelling SNR2 efficiency. Results indicate that magnification can potentially improve the signal and noise performance of digital images. Results also show that a cross over point occurs in the spatial frequency above and below which the effects of magnification differ indicating that there are task dependent tradeoffs associated with magnification. The cross over point varies depending upon focal spot size, pixel size, x-ray energy, and source-to-image-distance (SID). For mammography, the cross over point occurs for a 0.3 mm focal spot while a 0.6 mm focal spot indicates that magnification does not improve image quality due to focal spot blurring. Thus, the benefit of magnification may be limited. For general radiography (as well as mammotomography), and chest radiography, the cross over point changes with SID. For a system with a 0.3 mm focal spot, 100 microm pixel size, a 2 m SID, and the applicable tissue thickness and scatter components, optimal magnification improved SNR2 by approximately 1.2 times for mammography and 1.5 times for general radiography (and mammotomography). These results indicate that the optimal geometry can improve image quality without changing patient dose or otherwise reduce dose without compromising image quality.

Algorithms↗

Chest radiography practice in critically ill patients: a postal survey in the Netherlands.

BACKGROUND: To ascertain current chest radiography practice in intensive care units (ICUs) in the Netherlands. METHODS: Postal survey: a questionnaire was sent to all ICUs with > 5 beds suitable for mechanical ventilation; pediatric ICUs were excluded. When an ICU performed daily-routine chest radiographs in any group of patients it was considered to be a "daily-routine chest radiography" ICU. RESULTS: From the number of ICUs responding, 63% practice a daily-routine strategy, in which chest radiographs are obtained on a daily basis without any specific reason. A daily-routine chest radiography strategy is practiced less frequently in university-affiliated ICUs (50%) as compared to other ICUs (68%), as well as in larger ICUs (> 20 beds, 50%) as compared to smaller ICUs (< 20 beds, 65%) (P > 0.05). Remarkably, physicians that practice a daily-routine strategy consider daily-routine radiographs helpful in guiding daily practice in less than 30% of all performed radiographs. Chest radiographs are considered essential for verification of the position of invasive devices (81%) and for diagnosing pneumothorax, pneumonia or acute respiratory distress syndrome (82%, 74% and 69%, respectively). On demand chest radiographs are obtained after introduction of thoracic drains, central venous lines and endotracheal tubes in 98%, 84% and 75% of responding ICUs, respectively. Chest films are also obtained in case of ventilatory deterioration (49% of responding ICUs), and after cardiopulmonary resuscitation (59%), tracheotomy (58%) and mini-tracheotomy (23%). CONCLUSION: There is notable lack of consensus on chest radiography practice in the Netherlands. This survey suggests that a large number of intensivists may doubt the value of daily-routine chest radiography, but still practice a daily-routine strategy.

Journal Article↗

Digital subtraction radiography in artificial recurrent caries detection.

The diagnostic accuracy of digital subtraction radiography in detection of artificial recurrent caries lesions was assessed in this project. The use of digital subtraction radiography has been shown to markedly increase the accuracy of the detection of destruction in the periodontal bone, but the method has not been evaluated in secondary caries detection. Defects of three different sizes, simulating recurrent caries, were sequentially prepared in the interproximal cavity preparation margins of 28 teeth. Two composite restorative materials with different radiographic densities were used as posterior restorations, and a radiograph was obtained of each defect size and restorative material. The radiographs were digitized and subtracted from the reference images, and the conventional radiographs and the subtraction images were evaluated by seven observers. The data were analysed with ROC statistics. Subtraction radiography was found to be superior to conventional radiography in recurrent caries detection, mainly by reducing the false-positive diagnoses. The radiopacity of the restorative material had a significant effect on accuracy with conventional but not with subtraction radiography.

Analysis of Variance↗

Pelvimetry by digital radiography and its dosimetry.

Sonography is firmly established in obstetrics as the method of choice for the localization of fetus and placenta. However, for the determination of pelvic dimensions sonography does not suffice. Thus, for a few strictly selected indications conventional x-ray pelvimetry is used. This has the disadvantage of the relatively high radiation dose for the fetus and the maternal gonads. Since the introduction of digital radiography, there is the alternative of digital pelvimetry. We performed dosimetry comparing digital and conventional radiography with the new high amplifying screens (Quanta III, Dupont) using an ionization dosimeter and a wax phantom. The radiation dose of digital radiography was 24 mu Gy. This corresponds to about 15% of a comparable conventional exposure (177 mu Gy). A further advantage of digital radiography is a standardized and rapid exposure technique; furthermore pelvic dimensions can be measured directly. The disadvantages are the poorer spacial resolution and poor image quality in obese patients. Digital radiography because of its lower radiation dose is suitable for pelvimetry for special indications.

Computers↗

Computed radiography in musculoskeletal imaging: state of the art.

Computed radiography is a 2K x 2K x 10 bit digital radiographic system that replaces the film-screen combination with a photo-stimulable phosphor plate. The advantages of this relatively new technology include linear detector response, improved detector efficiency, and digital processing capabilities. Musculoskeletal applications benefit significantly from these attributes, which result clinically in the ability to reduce both radiation dose and number of exposures. Studies of observers' performance have shown no statistically significant difference in diagnostic accuracy between film-screen and computed radiographic musculoskeletal images. Computed radiography is particularly useful in the evaluation of the musculoskeletal system in traumatized patients with portable radiographs, spine radiographs, scoliosis studies, and depiction of soft-tissue abnormalities. Limitations include change in image format and size, high cost, decreased spatial resolution, restricted throughput, increased perception of noise, and new artifacts that must be recognized. Spatial resolution limitations of computed radiography in identification of fine detail information can be improved by using magnification techniques. Radiation dose reduction with an exposure decrease of 25-50% can be achieved without loss of diagnostic accuracy, although this depends on the examination and the abnormality. An interactive workstation is important in the use of a computed radiographic system with capabilities to adjust display parameters to best depict images and disease. We conclude that computed radiography is an alternative to film-screen radiography without significant differences in diagnostic quality in the evaluation of musculoskeletal images.

Humans↗

Sensitivity and value of digital CT scout radiography for detecting ureteral stones in patients with ureterolithiasis diagnosed on unenhanced CT.

OBJECTIVE: When unenhanced CT reveals ureterolithiasis, some patients will require baseline or follow-up conventional radiography to help guide clinical management. We sought to determine the sensitivity of routinely obtained scout radiographs for revealing stones to determine if the scout view can be used in place of baseline conventional radiography. MATERIALS AND METHODS: We retrospectively reviewed the CT scout radiographs in conjunction with axial CT images in a series of 215 consecutive patients in whom CT revealed a single ureteral stone. On the scout radiographs, stones were classified as definitely visible, definitely not visible, or indeterminate. In addition, a phantom was constructed using fragments of kidney stones to evaluate the effect of the digital scout kilovoltage settings on stone visualization. RESULTS: Forty-nine percent of stones were definitely visible on scout radiography, 47% were definitely not visible, and 4% were indeterminate. Four stones larger than 10 mm that were not visible on scout radiography were composed of uric acid (n = 2) or xanthine (n = 2). Scout radiographs of the phantom determined an optimal kilovoltage setting of 80-100 kVp to visualize stones less than 3 mm, whereas stones greater than or equal to 3 mm were visible at all kilovoltage settings. CONCLUSION: In our series, 49% of ureteral stones were visible on the often-overlooked routine CT scout radiograph. Imaging of phantoms showed that stone visualization can be optimized by using the lowest kilovoltage settings. Therefore, the CT scout view can be used as a baseline study in patients requiring follow-up radiography and for planning treatment of patients requiring lithotripsy or other intervention. Finally, large stones not visible on scout radiographs are likely composed of uric acid or xanthine.

Abdominal Pain↗