Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Myopia”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Clinical outcome of wavefront-guided laser in situ keratomileusis in eyes with moderate to high myopia with thin corneas.

PURPOSE: To evaluate the clinical outcome of wavefront-guided laser in situ keratomileusis (LASIK) for the treatment of moderate to high myopia associated with a thin cornea. SETTING: Enaim Laser Medical Center, Tel Aviv, Israel. METHODS: This retrospective study included 98 eyes of 49 patients with moderate to high myopia (-5.20 to -10.35 diopters [D]) and thin corneas (456 to 498 mum) treated with wavefront-guided LASIK (Zyoptix, Bausch & Lomb) and followed for 36 months. Preoperative wavefront analysis was performed with a Hartmann-Shack aberrometer, and treatment was performed with the Technolas 217 z excimer laser system (Bausch & Lomb). Final refraction data, uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), optic zone size, ablation depth, optical aberrations, and night glare complaints were evaluated. RESULTS: Mean patient age was 28 years +/- 7 (SD), and mean preoperative spherical equivalent refraction was -7.06 D (range -5.20 to -10.35 D). Final UCVA ranged between 6/6 and 6/30. The safety index of the technique was 1.03, and the efficacy index was 0.67. Undercorrection of more than 0.50 D was observed in 41.3% of the high-myopic eyes (-7.00 to -10.35 D, n = 58) compared with 10% in the moderately myopic eyes (-5.00 to -6.75 D, n = 40). A significant reduction in spherical aberration (Z(4)0) was found 12 months postoperatively in all eyes. Night glare was documented in 4 eyes (4%) in the high myopia group. There were no cases of corneal ectasia. CONCLUSION: Zyoptix was safe in eyes with moderate to high myopia with relatively thin corneas (<498 microm). For myopia between -7.00 D and -10.35 D, a small optical zone (4.3 to 5.6 mm) may be applied as night glare was relatively rare, but significant undercorrection should be expected.

Adult↗

Changes in contrast sensitivity after Artisan lens implantation for high myopia.

PURPOSE: To determine the effects of Artisan lens implantation on contrast sensitivity. DESIGN: Prospective consecutive interventional case series. PARTICIPANTS AND CONTROLS: Forty-nine eyes of 30 patients with myopia and myopia with astigmatism, who underwent implantation of the Artisan iris-fixated phakic intraocular lens. Preoperative testing served as the control. INTERVENTION: Implantation of the Artisan phakic intraocular lens to correct myopia. MAIN OUTCOME MEASURES: Refractive predictability and Snellen visual acuity were evaluated preoperatively and at least 4 months postoperatively. Additionally, photopic and mesopic contrast sensitivities were measured at 1.5, 3, 6, 12, and 18 cycles per degree, with and without glare testing. RESULTS: The mean preoperative spherical equivalent (SE) was -12.16 diopters (D) (range, -6.88 to -18.00). The mean postoperative SE was -0.46+/-0.58 D (range, +0.50 to -1.75). Ninety percent of eyes were within 1.00 D of the predicted result, and 39% gained > or =1 lines of best-corrected visual acuity (BCVA). When compared with preoperative measurements, postoperative contrast sensitivity was increased under photopic conditions and slightly decreased under mesopic conditions. Adverse events were one wound leak requiring resuturing in the immediate postoperative period and one subluxed lens after significant blunt trauma. No eyes lost > or =2 lines of BCVA. CONCLUSIONS: Artisan implantation for the correction of high myopia seems to be a predictable procedure. Increases in photopic contrast sensitivity values after implantation of this phakic intraocular lens stand in distinction to the decreases in photopic contrast sensitivity previously reported after LASIK correction of this degree of myopia.

Adult↗

Atropine for the treatment of childhood myopia.

PURPOSE: To evaluate the efficacy and safety of topical atropine, a nonselective muscarinic antagonist, in slowing the progression of myopia and ocular axial elongation in Asian children. DESIGN: Parallel-group, placebo-controlled, randomized, double-masked study. PARTICIPANTS: Four hundred children aged 6 to 12 years with refractive error of spherical equivalent -1.00 to -6.00 diopters (D) and astigmatism of -1.50 D or less. INTERVENTION: Participants were assigned with equal probability to receive either 1% atropine or vehicle eye drops once nightly for 2 years. Only 1 eye of each subject was chosen through randomization for treatment. MAIN OUTCOME MEASURES: The main efficacy outcome measures were change in spherical equivalent refraction as measured by cycloplegic autorefraction and change in ocular axial length as measured by ultrasonography. The primary safety outcome measure was the occurrence of adverse events. RESULTS: Three hundred forty-six (86.5%) children completed the 2-year study. After 2 years, the mean progression of myopia and of axial elongation in the placebo-treated control eyes was -1.20+/-0.69 D and 0.38+/-0.38 mm, respectively. In the atropine-treated eyes, myopia progression was only -0.28+/-0.92 D, whereas the axial length remained essentially unchanged compared with baseline (-0.02+/-0.35 mm). The differences in myopia progression and axial elongation between the 2 groups were -0.92 D (95% confidence interval, -1.10 to -0.77 D; P<0.001) and 0.40 mm (95% confidence interval, 0.35-0.45 mm; P<0.001), respectively. No serious adverse events related to atropine were reported. CONCLUSIONS: Topical atropine was well tolerated and effective in slowing the progression of low and moderate myopia and ocular axial elongation in Asian children.

Administration, Topical↗

Neural and optical limits to visual performance in myopia.

We investigated the relative importance of neural and optical limitations to visual performance in myopia. A number of visual performance measures were made on all or subsets of 121 eyes of emmetropic and myopic volunteers aged 17-35 years. These tests included visual measures that are mainly neurally limited (spatial summation out to +/-30 degrees in the horizontal visual field and resolution acuity out to +/-10 degrees in the horizontal visual field) and central ocular aberrations. We found that myopia affected the neurally limited tests, but had little effect on central higher order aberration. The critical area for spatial summation increased in the temporal visual field at 0.03 log units/dioptre of myopia. Resolution acuity decreased at approximately 0.012 log units/dioptre of myopia. Losses of visual function were slightly greater in the temporal than in the nasal visual field. The observed visual deficit in myopia can be explained by either global retinal expansion with some post-receptor loss (e.g. ganglion cell death) or a posterior polar expansion in which the point about which expansion occurs is near the centre of the previously emmetropic globe.

Adolescent↗

A randomized trial of rigid gas permeable contact lenses to reduce progression of children's myopia.

PURPOSE: To test whether rigid gas permeable (RGP) contact lens wear can reduced the rate of myopia progression in school age children. DESIGN: Randomized clinical trial. METHODS SETTING: Single clinical center. STUDY POPULATION: Both eyes of 428 Singaporean children. INCLUSION CRITERIA: 6 through 12 years of age with myopia between -1 and -4 diopters, astigmatism <or= 2 diopters, no prior contact lens wear, no other ocular pathologies. INTERVENTION: Spectacle or RGP lens correction for myopia. After a 3-month adaptation period, 383 children were followed, and 298 (78%) remained after 24 months. OUTCOME MEASURES: Cycloplegic subjective refraction, keratometry, and axial length measured at 12 and 24 months. RESULTS: Children who adapted to contact lenses wore them for a median of 7 hours per day, but no more than 40% wore them at least 8 hours per day, 7 days per week. Spectacles were worn for a median of 15 hours per day at the time of the 24-month follow-up. There was an increase in the spherical equivalent of -1.33 and -1.28 diopters (P =.64), and axial length increased by 0.84 and 0.79 mm (P =.38) over 2 years among children randomized to contact lenses and spectacles, respectively. Adjustment for baseline differences between the groups and for hours per day of contact lens wear did not alter these findings. CONCLUSIONS: Rigid gas permeable lenses did not slow the rate of myopia progression, even among children who used them regularly and consistently. It is unlikely that this intervention holds promise as a method by which to slow the rate of progression of myopia in children.

Child↗

The quality of life in patients with pathologic myopia.

PURPOSE: To evaluate the functional status in daily life and the quality of life (QOL) of pathologic myopia patients. METHODS: A cross-sectional study was conducted using data of consecutive pathologic myopia patients (n = 200) and control subjects (n = 144). The influence of the disease on the daily life and the QOL of patients were evaluated using a self-rated questionnaire. The questionnaire covered the full range of daily life activity, including daily tasks depending on visual acuity, social and emotional handicaps, and cognition of disease, and the QOL of pathologic myopia patients. RESULTS: The functional status in daily life and the QOL of patients were reduced compared with control subjects. The influence of pathologic myopia on a patient's daily life was primarily the result of three major factors, handicap, disability, and support. All three factors correlated with the QOL, the degree of handicap having the strongest correlation. CONCLUSION: The functional status in daily life and the QOL of pathologic myopia patients were reduced; this decline in QOL was attributed to handicap and disability caused by the ocular disease.

Adolescent↗

Changes in blood-retinal barrier permeability in form deprivation myopia in tree shrews.

To study the correlation between blood-retinal barrier (BRB) permeability and development of form deprivation (FD) myopia, FD was induced in tree shrews. The refractive error and the axial dimensions of the optical elements were measured. Ocular fluorescence was measured before and after fluorescein-Na injection. The inward permeability (P(in)) of the BRB was measured before and 15, 30, and 45 days after FD was induced. FD eyes became significantly myopic 15 days after FD was induced (P<0.01), and myopia progressed 45 days after FD was induced compared with untreated controls. Neither anterior chamber length nor lens thickness changed significantly. The vitreous chamber in FD eyes, however, was significantly elongated from 15 days after FD was induced (P<0.01) compared with controls. The P(in) ratio (P(in) [FD eye]/P(in) [untreated control]), increased significantly 45 days after FD was induced (P<0.05). In FD myopia in tree shrews, the BRB permeability increases abnormally. Impaired BRB function might be a secondary effect of myopia development rather than the cause of myopia.

Animals↗

Similar genetic susceptibility to form-deprivation myopia in three strains of chicken.

Myopia development in humans depends on a complex interplay between genetic and environmental factors. Many of those who become myopic when exposed to a myopigenic environment are likely to do so because of a genetic susceptibility, whereas others somehow remain immune. In the most intensively studied model of environmentally induced myopia, form-deprivation myopia in the chick, there is convincing evidence of differential genetic susceptibility to myopia development, both within-strains and between-strains. To date, however, these have involved relatively small differential responses. The aim of this investigation was to examine genetic susceptibility to a highly uniform regimen of form-deprivation in three strains of chick (white leghorn, brown leghorn and broiler) expected to differ greatly in genetic background and in normal eye size, and to gauge the potential for mapping the quantitative trait loci (QTL) underlying this differential susceptibility. Despite striking differences in normal eye size, all three strains studied developed a similar degree of induced myopia. Whilst the degree of induced vitreous chamber elongation differed significantly between-strains, it was concluded that the high within-strain variation in the response to form-deprivation would prevent the effective application of QTL mapping approaches to identify genes conferring this susceptibility. In contrast, the strains used here would be ideal for use in mapping QTL controlling normal ocular component dimensions.

Analysis of Variance↗

Flicker parameters are different for suppression of myopia and hyperopia.

Axial eye growth rates in the chicken are controlled by local retinal image-processing circuits. These circuits quantify the loss of contrast for different spatial frequencies and promote axial eye growth rates in correlation with the amount of retinal image degradation ("deprivation myopia"). They also distinguish whether the plane of focus lies in front of or behind the retina. How the sign of defocus is detected still remains unclear. Cues from chromatic aberration are not important. In an attempt to isolate retinal circuits controlling the development of myopia or hyperopia, young chickens were raised in flickering light of different frequencies (12 and 6 Hz) and duty cycles (4-75%) produced by rotating chopper disks. The effects of flickering light on refractive errors and change in axial growth rates induced by translucent occluders or defocusing lenses were measured by infrared retinoscopy and A-scan ultrasound, respectively. Retinal electrical activity was evaluated by flicker ERG after matching flicker parameters and stimulation brightness at retinal surface. Changes in retinal and vitreal dopamine content caused by flicker in occluded and normal eyes were determined by HPLC-ECD. Strikingly, suppression of myopia occurred for similar flicker parameters, whether induced by translucent occluders ("deprivation") or negative lenses ("defocus"). The degree to which myopia was suppressed was correlated with the duration of flicker dark phase and with the ERG amplitude. In contrast, suppression of hyperopia did not correlate with these parameters. We conclude that two different retinal circuits with different temporal characteristics are involved in the processing of hyperopic defocus/deprivation and of myopic defocus, the first one dependent on flicker ERG amplitude. However, we did not find any correlation between the rate of dopamine release and the degree of inhibition of deprivation myopia in flickering light.

Animals↗

Form-deprivation myopia in monkeys is a graded phenomenon.

To shed light on the potential role of the phenomenon of form-deprivation myopia in normal refractive development, we investigated the degree of image degradation required to produce axial myopia in rhesus monkeys. Starting at about 3 weeks of age, diffuser spectacle lenses were employed to degrade the retinal image in one eye of 13 infant monkeys. The diffusers were worn continuously for periods ranging between 11 and 19 weeks. The effects of three different strengths of optical diffusers, which produced reductions in image contrast that ranged from about 0.5 to nearly 3 log units, were assessed by retinoscopy and A-scan ultrasonography. Control data were obtained from ten normal infants and three infants reared with clear, zero-powered lenses over both eyes. Eleven of the 13 treated infants developed form-deprivation myopia. Qualitatively similar results were obtained for the three diffuser groups, however, the degree of axial myopia varied directly with the degree of image degradation. Thus, form-deprivation myopia in monkeys is a graded phenomenon and can be triggered by a modest degree of chronic image degradation.

Animals↗

Degree of myopia in relation to intelligence and educational level.

Intelligence test scores and educational levels were compared for 5943 myopic and 9891 non-myopic 18-year-old men being drafted for military service in Denmark. The former were grouped by degree of myopia, in the range -0.25 diopters (D) to -7.75 D, according to the power of correcting lenses required. Myopes of all degrees had significantly higher test scores and educational levels than non-myopes. However, the relation of these two variables to degree of myopia was not linear; for both variables there were no significant differences among myopia groups in the range -2.0 to -7.75 D. Whereas factors associated with intelligence and education seem to be important in triggering the onset of myopia, they seem to be much less important in determining the degree to which myopia progresses.

Adolescent↗

Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology.

OBJECTIVE: This document describes laser in situ keratomileusis (LASIK) for myopia and astigmatism and examines the evidence to answer key questions about the efficacy and safety of the procedure. METHODS: A literature search conducted for the years 1968 to 2000 retrieved 486 citations and an update search conducted in June 2001 yielded an additional 243 articles. The panel members reviewed 160 of these articles and selected 47 for the panel methodologist to review and rate according to the strength of evidence. A Level I rating is assigned to properly conducted, well-designed, randomized clinical trials; a Level II rating is assigned to well-designed cohort and case-control studies; and a Level III rating is assigned to case series and poorly designed prospective and retrospective studies, including case-control studies. RESULTS: The assessment describes randomized controlled trials published in 1997 or later (Level I evidence) and more recent comparative and noncomparative case series (Level II and Level III evidence), focusing on results for safety and effectiveness. It is difficult to extrapolate results from these studies that are comparable to current practices with the most recent generation lasers because of the rapid evolution of LASIK technology and techniques. It is also difficult to compare studies because of variations in the range of preoperative myopia, follow-up periods, lasers, nomograms, microkeratomes and techniques, the time frame of the study, and the investigators' experience. CONCLUSIONS: For low to moderate myopia, results from studies in the literature have shown that LASIK is effective and predictable in terms of obtaining very good to excellent uncorrected visual acuity and that it is safe in terms of minimal loss of visual acuity. For moderate to high myopia (>6.0 D), the results are more variable, given the wide range of preoperative myopia. The results are similar for treated eyes with mild to moderate degrees of astigmatism (<2.0 D). Serious adverse complications leading to significant permanent visual loss such as infections and corneal ectasia probably occur rarely in LASIK procedures; however, side effects such as dry eyes, night time starbursts, and reduced contrast sensitivity occur relatively frequently. There were insufficient data in prospective, comparative trials to describe the relative advantages and disadvantages of different lasers or nomograms.

Academies and Institutes↗

Pathogenesis of transient high myopia after blunt eye trauma.

OBJECTIVE: To determine the pathogenesis of transient high myopia after blunt eye trauma. DESIGN: Two observational case reports and literature review. METHODS: Refraction was measured in two patients with an autorefractometer in the acute and convalescent stages after a blunt eye injury. The anterior chamber angle, the ciliary body, and the choroid were examined by ultrasound biomicroscopy (UBM) in the acute and convalescent stages. In one patient, the anterior chamber depth, lens thickness, and axial length were measured by A-scan ultrasonography in the acute and convalescent stages. MAIN OUTCOME MEASURES: Comparison of the refraction, anterior chamber depth, lens thickness, axial length, and the UBM-determined appearance of the choroid and ciliary body during the acute stage with the values during the convalescent stages. RESULTS: The first patient showed a myopic shift of -9.75 diopters (D) and an anterior chamber shallowing of 0.94 mm measured 3 days after trauma by an air bag inflation compared with the measurements at the convalescent phase. UBM showed an annular ciliochoroidal effusion with ciliary body edema, anterior rotation of the ciliary processes, and disappearance of the ciliary sulcus. Eleven days after the injury, these UBM findings normalized, and the myopia decreased to -0.75 D, 27 days after trauma. The second patient had a myopic shift of -8.9 D compared with the convalescent phase, immediately after blunt trauma by a firework. Seven days after the injury, UBM revealed a partial cyclodialysis in addition to findings similar to those in the first patient. Ten days after injury, a myopic shift (-4.75 D), anterior chamber shallowing (by 1.1 mm), and thickening of the crystalline lens (by 0.27 mm) were observed compared with the convalescent phase. Associated UBM findings confirmed the anterior shift of the lens-iris diaphragm. Seventeen days after trauma, the UBM findings, including the cyclodialysis, were normalized, and the myopia had decreased to -1.0 D. CONCLUSIONS: Transient high myopia after blunt trauma is caused by anatomic changes in the ciliary body and crystalline lens. The anterior shift of the lens-iris diaphragm caused by ciliochoroidal effusion with ciliary body edema and thickening of the crystalline lens from blunt eye trauma are involved in traumatic high myopia.

Adult↗

The relation of myopia and astigmatism in developing eyes.

The relation of astigmatism and myopia was analyzed in 298 myopic children, ages birth to 10 years. The mean spherical equivalent, determined by cyclopentolate retinoscopy, for the entire group was--2.9 diopters and did not change significantly with age. However, in 3-year-old children and younger, myopia progressed in eyes with greater than or equal to 1 diopter of cylinder and tended to increase through age 8 years in those having greater than or equal to 3 diopters of cylinder. Also, astigmatic errors greater than or equal to 1 diopter, especially of oblique orientation, were associated with higher degrees of myopia than nonastigmatic errors. These data from myopic children suggest that uncorrected astigmatism during a period of visual immaturity influences the course of myopia. Thus, naturally occurring astigmatic errors, that are frequent among infants and young children, appear to have a role similar to the vision blurring perturbations that trigger the development of myopia in young animals. Ascertainment and full correction of these refractive errors in young children may be important in assuring the best possible vision.

Age Factors↗

Results of excimer laser retreatment of residual myopia after previous photorefractive keratectomy.

BACKGROUND: Nine percent to 30% of all patients who undergo a single excimer laser photorefractive keratectomy (PRK) do not achieve an unaided visual acuity of 20/ 40 or better and may require optical correction to obtain adequate vision. METHODS: The authors performed a retrospective analysis of the records of 164 patients who had undergone retreatment with the excimer laser for residual myopia after a previous PRK. Mean follow-up was 35.5 +/- 15.2 weeks (range, 26-104 weeks). RESULTS: The mean spherical equivalent (MSE) before retreatment was -2.59 +/- 1.36 diopter (D) (range, -0.50 to -7.75 D). The final MSE after reablation was -0.52 +/- 1.36 D (range, 2.50 to -5.50). Of the 164 patients, 107 (65.2%) obtained a final refraction within 1.00 D of emmetropia and 111 (67.3%) achieved an unaided visual acuity of 20/40 or better. Only 10 patients (6.1%) lost more than one Snellen line of best-corrected visual acuity. The final MSE result for the subgroup of patients who had a pre-retreatment myopia of between -0.50 and -1.90 D (-0.31 +/- 1.09 D) was significantly closer to emmetropia than that of the subgroup with a residual myopia of -4.00 to -7.75 D (-1.62 +/- 1.94 D). CONCLUSIONS: Excimer laser retreatment may provide a relatively safe and predictable method of correcting residual myopia after an earlier PRK with a 25% extra correction recommended for residual myopia.

Adult↗

Predictability of spherical photorefractive keratectomy for myopia.

OBJECTIVE: This study aimed to examine the effects of purely spherical excimer laser photorefractive keratectomy (PRK) for myopia. DESIGN: Consecutive case series. PARTICIPANTS: A total of 3218 eyes with a mean preoperative mean spherical equivalent (MSE) of -3.75 diopters (D) +/- 1.73 D standard deviation (SD) (range, -1.00 D to -11.88 D) underwent PRK with a Nidek EC-5000 excimer laser. Eyes were divided into groups based on the degree of preoperative myopia in 1 D steps. INTERVENTION: All eyes underwent PRK with a Nidek EC-5000 excimer laser. MAIN OUTCOME MEASURE: Visual and refractive outcome of PRK treatment was measured. RESULTS: After a mean follow-up period of 52.6 weeks (range, 26-150 weeks), the final MSE was -0.07 D (+/-0.68 D) (range, -5.50 D to +4.50 D). Of the 3218 eyes, 2919 (90.7%) were within 1.00 D of emmetropia, and 3038 (94.4%) of eyes had an uncorrected visual acuity of 20/40 or better, with 1886 (58.6%) achieving 20/20 or better visual acuity. Eyes in the lower preoperative myopia groups had a greater chance of attaining 20/40 unaided visual acuity than those in the higher groups (e.g., 98.3% of the -2D group and 53.6% of the -9D group achieved 20/40 unaided visual acuity). Overall, mean postoperative haze was 0.29+/-0.39 SD (scale, 0-3), and 29 eyes (0.9%) lost 0.3 or more logarithm of the minimum angle of resolution (LogMAR) unit of best-corrected visual acuity. CONCLUSIONS: Excimer laser PRK is an effective treatment for myopia of up to -9.00 D. The outcome parameters are less predictable for eyes with greater than -9.00 D of myopia.

Adult↗

Laser in situ keratomileusis for moderate and high myopia and myopic astigmatism.

OBJECTIVE: This study evaluated the predictability, stability, and safety of laser in situ keratomileusis (LASIK) in myopia and myopic astigmatism. DESIGN: The study design was a prospective, unmasked, nonrandomized clinical trial. PARTICIPANTS: Participating were 25 patients with myopia (37 eyes) with astigmatism of less than 1.00 diopter (D), divided into 3 subgroups (-5.00 to -9.90 D, 8 eyes; -10.00 to -14.90 D, 10 eyes; -15.00 to -29.00 D, 19 eyes), and 37 patients with myopia (56 eyes) with corneal astigmatism of 1.00 to 4.50 D, divided into 3 subgroups (-5.00 to -9.90 D, 12 eyes; -10.00 to -14.90 D, 24 eyes; -15.00 to -29.00 D, 20 eyes). INTERVENTION: LASIK was performed using the Automatic Corneal Shaper and the Keracor 116 excimer laser. MAIN OUTCOME MEASURES: Visual acuity, manifest refraction, central corneal islands, ablation decentration, and patient satisfaction were measured. RESULTS: At 12 months, predictability, regression between 1 and 12 months, uncorrected visual acuity (UCVA), loss of two or more lines of corrected visual acuity, and patient satisfaction of the spherical (toric) groups are reported. Subgroups -5.00 to -9.90 D: 100% (75%) +1.00 D; regression less than or equal to 1.00 D in 100% (91.7%); UCVA greater than or equal to 20/40 in 87.5% (70%); none lost two or more lines; 100% (84%) highly satisfied. Subgroups -10.00 to -14.90 D: 60% (78.3%) +/-1.00 D; regression less than or equal to 1.00 D in 100% (87%); UCVA greater than or equal to 20/40 in 77.8% (86.4%); 10% (4.3%) lost two lines; 90% (91%) highly satisfied. Subgroups -15.00 to -29.00 D: 38.9% (21.4%) +/-1.00 D; regression less than or equal to 1.00 D in 72.2% (64.3%); UCVA greater than or equal to 20/40 in 33.3% (40%); 5.6% (7.1%) lost two lines; 78% (50%) highly satisfied. Differences of predictability and change of manifest refraction between subgroups of -5.00 to -9.90 D and -15.00 to -29.00 D were statistically significant. Central islands (decentrations) were observed in 17% (5.6%) of eyes of the spherical and in 16% (4.1%) of the toric group. Overall, the corneal interface was visible in 8.2%. CONCLUSIONS: The LASIK method used in this study showed stability of manifest refraction and adequate uncorrected central visual acuity in a large percentage of patients with myopia up to -15.00 D. Corneal stability was not as uniform. Central corneal islands were observed in a sizable minority of patients despite pretreatment. For myopia greater than 15.00 D, accuracy and patient satisfaction were sufficiently poor to advise against using the authors' treatment technique in these groups. Visually significant microkeratome and laser-related problems were noted in a smaller percentage of patients. Patients with astigmatism correction were less pleased with results than were patients who received spherical corrections.

Adolescent↗

Prospective comparison of single-zone and multizone laser in situ keratomileusis for the correction of low myopia.

OBJECTIVE: This study aimed to determine whether there is a true difference in predictability between single-zone and multizone laser in situ keratomileusis (LASIK) for the correction of low myopia or whether any difference in predictability is because of a need for separate clinical nomograms for the two treatments. DESIGN: A prospective, randomized, clinical trial. PARTICIPANTS: Fourteen surgeons and 190 eyes of 95 patients with myopia who desired surgical correction of myopia ranging from -2.00 to -7.00 diopters (D) participated. INTERVENTION: Fellow eyes of patients with myopia undergoing bilateral simultaneous LASIK were randomized to single-zone and multizone ablation. Astigmatism was not corrected at the time of LASIK. MAIN OUTCOME MEASURES: Predictability, postoperative videokeratography, and contrast sensitivity were assessed at 3 months after surgery. RESULTS: At 3 months, r2 values relating laser setting to change in spherical equivalent refraction were 0.78 for single-zone and 0.76 for multizone ablation; mean outcome with respect to intended was -0.84 D (0.65 standard deviation [SD]) for single-zone and -0.62 D (0.78 SD) for multizone eyes (P = 0.035). There was no relationship between single-zone and multizone ablation and the likelihood of asymmetric postoperative videokeratography (P = 0.83). The only difference in contrast sensitivity was a significantly greater decrease in log contrast for multizone eyes at 12 cyc/deg under undilated conditions. CONCLUSIONS: There is no true difference in predictability between single-zone and multizone LASIK for the correction of low myopia. Separate clinical nomograms for single-zone and multizone LASIK should eliminate the difference in predictability that was observed in this clinical trial.

Adolescent↗