Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Metallocenes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Amperometric enzyme electrode for determination of theophylline in serum.

This paper describes an amperometric enzyme electrode for the rapid determination of theophylline in serum. The method is based on the catalysed oxidation of theophylline by the haem-containing enzyme theophylline oxidase. Results are presented for two approaches. First, ferrocene monocarboxylic acid was used as a mediator. The second-order rate constant was 1.1 x 10(3) 1 mol-1 s-1. Secondly, the organic conducting salt NMP.TCNQ was used to construct enzyme electrodes. These electrodes were employed for the rapid (60 s) measurement of theophylline in serum at a working potential of +100 mV versus Ag/AgCl. Linear calibration curves were obtained over the clinically relevant range (y = 0.13x + 0.22, n = 8). Caffeine, theobromine and 3-methylxanthine at levels up to 100 mg l-1 do not interfere and 1-methylxanthine shows cross-reactivity at concentrations greater than 50 mg l-1.

Biosensing Techniques↗

Non-leaking amperometric biosensors based on high-molecular ferrocene derivatives.

Poly(ethylene glycol)-bound ferrocene derivatives, synthesized after activation of ferrocene carboxylic acid with 1,1'-bis carbonyl diimidazol, are able to transfer electrons from the active site of reduced glucose oxidase to electrode surfaces. This opens a route to non-leaking mediated enzyme electrodes for the determination of glucose.

Biosensing Techniques↗

A glucose sensor fabricated by the screen printing technique.

A novel glucose sensor employing ferrocene-modified glucose oxidase is fabricated using the screen printing technique. Glucose oxidase is covalently bound to the electron mediator ferrocenecarboxylic acid in order to obtain higher enzyme activity. The ferrocene-glucose oxidase shows an increased catalytic current because the ferrocene acts as an electron transfer relay between the active centre of the enzyme and the gold electrode. Glucose sensors employing enzymes modified with ferrocene in various ways are successfully fabricated using the screen printing technique. The ink component containing the ferrocene-glucose oxidase is specially developed to be applicable to the printing machine. The printed glucose sensor chip offers a stable calibration profile and stable electrochemical properties.

Biosensing Techniques↗

Mechanism of action of ferrocene derivatives on the catalytic activity of topoisomerase IIalpha and beta--distinct mode of action of two derivatives.

Topoisomerase II is found to be present in two isoforms alpha and beta, and both the isoforms are regulated in cancerous tissue. Development of isoform-specific topoisomerase II poisons has been of great interest for cancer-specific drug targeting. In the present investigation using quantitative structure-activity analysis of ferrocene derivatives, we show that two derivatives of ferrocene, azalactone ferrocene and thiomorpholide amido methyl ferrocene, can preferentially inhibit topoisomerase IIbeta activity. Thiomorpholide amido methyl ferrocene shows higher inhibition of catalytic activity (IC(50) = 50 microM) against topoisomerase IIbeta compared to azalactone ferrocene (IC(50) = 100 microM). The analysis of protein DNA intermediates formed in the presence of these two compounds suggests that azalactone ferrocene readily induces formation of cleavable complex in a dose-dependent manner, in comparison with thiomorpholide amido methyl ferrocene. Both the compounds show significant inhibition of DNA-dependent ATPase activity of enzyme. These results suggest that azalactone ferrocene inhibits DNA passage activity of enzyme leading to the formation of cleavable complex, while thiomorpholide amido methyl ferrocene competes with ATP binding resulting in the inhibition of catalytic activity of enzyme. In summary, thiomorpholide amido methyl ferrocene and azalactone ferrocene show distinctly different mechanisms in inhibition of catalytic activity of topoisomerase IIbeta.

Adenosine Triphosphatases↗

A study of the topoisomerase II activity in HIV-1 replication using the ferrocene derivatives as probes.

Human Topoisomerase II is present in two isoforms, 170KDa alpha and 180KDa beta. Both the isoforms play a crucial role in maintenance of topological changes during DNA replication and recombination. It has been shown that Topoisomerase II activity is required for HIV-1 replication and the enzyme is phosphorylated during early time points of HIV-1 replication. In the present study, we have studied the molecular action of Topoisomerase II inhibitors, azalactone ferrocene (AzaFecp), Thiomorpholide amido methyl ferrocene (ThioFecp), and Ruthenium benzene amino pyridine (Ru(ben)Apy) on cell proliferation and also on various events of HIV-1 replication cycle. The Topoisomerase II beta over-expressing neuroblastoma cell line shows a higher sensitivity to these compounds compared to the Sup-T1 cell line. All the three Topoisomerase II inhibitors show significant anti-HIV activity at nanomolar concentrations against an Indian isolate of HIV-1(93IN101) in Sup-T1 cell line. An analysis of action of these compounds on proviral DNA synthesis at 5h of post-infection shows that they inhibit proviral DNA synthesis as well as the formation of pre-integration complexes completely. Further analysis, using polymerase chain reaction and western blot, showed that both the Topoisomerase II alpha and beta isoforms are present in the pre-integration complexes, suggesting their significant role in HIV-1 replication.

Antigens, Neoplasm↗

An electrochemical study of enzymatic oligonucleotide digestion.

This paper describes the synthesis and application of a novel ferrocene (Fc) label that can be efficiently attached to oligonucleotides. We demonstrate how pulse electrochemical methods can be used to measure very low concentrations of ferrocene label and, importantly, show good electroanalytical discrimination between a labelled oligonucleotide and an enzyme digested labelled oligonucleotide, in which the ferrocene label nucleotide conjugate has been released. Real time in situ analysis gives a much greater understanding of the process. Potential applications include the detection of specific nucleic acid sequences and measurement of nuclease activity.

Biosensing Techniques↗

The electrochemical behaviour of ferrocene in a photocurable poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) film for a glucose biosensor.

A single-step fabrication of a glucose biosensor with simultaneous immobilization of both ferrocene mediator and glucose oxidase in a photocurable methacrylic film consisting of poly(methyl methacrylate-co-2-hydroxylethyl methacrylate) was reported. The entrapped ferrocene showed reversible redox behaviour in the photocured film and no significant leaching of both entrapped ferrocene and enzyme glucose oxidase was observed because of the low water absorption properties of the co-polymer films. From electrochemical studies, ferrocene entrapped in the co-polymer film demonstrated slow diffusion properties. A linear glucose response range of 2-11 mM was obtained at low applied potential of +0.25 V. The glucose biosensor fabricated by this photocuring method yielded sensor reproducibility and repeatability with relative standard deviation of <10% and long-term stability of up to 14 days. The main advantage of the use of photocurable procedure is that biosensor membrane fabrication can be performed in a single step without any lengthy chemical immobilization of enzyme.

Biosensing Techniques↗

A conductive ormosil encapsulated with ferrocene conjugate and multiwall carbon nanotubes for biosensing application.

Highly non-toxic and conductive ormosil composite film was prepared using (3-aminopropyl)triethoxysilane and 2-(3,4-epoxycyclohexyl)-ethyltrimethoxysilane by doping with ferrocenemonocarboxylic acid-bovine serum albumin (FMC-BSA) conjugate and multiwall carbon nanotubes (MWNTs). With glucose oxidase (GOD) as a model enzyme this film could be used to design an amperometric biosensor for glucose determination. The entrapped FMC-BSA conjugate performed excellent redox electrochemistry and the immobilized GOD was highly stable. Under optimal conditions this biosensor was able to detect glucose with a detection limit of 20 microm (S/N=3) in the linear range of 0.05-20.0 mm in flow system, which was wider than the batch amperometric mode, with an analysis time of 25 s for each sample. The value of K(M)(app) was 6.6 mm. The proximity of these three components FMC-BSA, MWNTs and GOD enhanced the electron transfer between the film and electrode. This film could be used efficiently for the entrapment of other redox bioactive compounds and biosensing/bioelectrochemical applications.

Biosensing Techniques↗

Rational design of novel diketoacid-containing ferrocene inhibitors of HIV-1 integrase.

Molecular interaction field, density functional, and docking studies of novel potential ferrocene inhibitors of HIV-1 integrase (IN) are reported. The high docking scores, analysis of the ligand-receptor interactions in the active site as well as the molecular interaction potential calculations at the binding site of the receptor indicate important features for novel HIV-1 IN inhibitors. We also confirm in this work a novel binding trench in HIV-1 integrase, recently reported in a theoretical work by other authors. This observation may be interesting since the lack of detailed structural information about IN-ligand interactions has hampered the design of IN inhibitors. Our proposed ligands are open to experimental synthesis and testing.

Acids↗

Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers.

The enzyme glucose oxidase (GOx) has been immobilized electrostatically onto carbon and platinum electrodes modified with mixed ferrocene-cobaltocenium dendrimers. The ferrocene units have been used successfully as mediators between the GOx and the electrode under anaerobic conditions. In experiments carried out in the presence of oxygen, the cobaltocenium moieties act as electrocatalysts in the reduction of the oxygen in the solution, thus making possible the determination of the oxygen variation due to the enzymatic reaction, with high sensitivity. The current response of the electrode was determined by measuring steady-state current values obtained applying a constant potential. The effect of the substrate concentration, the dendrimer generation, the thickness of the dendrimer layer, interferences, and storage on the response of the sensors were investigated.

Adsorption↗

Synergetic effect for NADH oxidation of ferrocene and zeolite in modified carbon paste electrodes. New approach for dehydrogenase based biosensors.

The development of electrochemical biosensors using dehydrogenases associated with the corresponding cofactor is strongly related to the better understanding of NADH oxidation at the electrode surface. The aim is to lower the necessary overvoltage and consequently to escape interferences and electrode fouling. In this paper, we show that carbon paste electrode (CPE) modified with NaY zeolite fulfils this requirements thanks to its hydrophilic surface. Oxidation of NADH at ferrocene (FcH) modified carbon paste electrode exhibits a rather slow electrocatalytic effect. We demonstrated the existence of synergetic effect on the electrocatalytic oxidation of NADH when the CPE is doped with zeolite (NaY) and FcH mediator or with the zeolite exchanged beforehand with the mediator (Y-Ferricinium, YFcH). This cumulative effect permits to reach high sensitivity for NADH detection and offers new way for the development of enzymatic biosensors using dehydrogenases depending on NADH as cofactor.

Biosensing Techniques↗

Molecular assembly of redox-conductive ferrocene-streptavidin conjugates--towards bio-electrochemical devices.

Peptidic spacers, 0.4 and 2 nm in length, were used to couple ferrocene moieties to streptavidin. The resulting conjugates were immobilised on electrode surfaces using biotin binding. The electron transfer through multilayers of the conjugates is strongly dependent on the length of the spacer between the protein and the attached ferrocene. A monolayer of the long-linker conjugate immobilised on interdigitated microelectrode arrays was found to electrochemically bridge the 2 microm wide non-conductive gap between the electrodes. The redox current through the layer is dependent on external parameters such as the applied voltage difference between the two electrode arrays or the temperature. The long-range electrochemical conductivity in combination with the biotin binding capability is a prerequisite for the application of the conjugates in future bio-electrochemical devices.

Adsorption↗

Determination of hydrogen peroxide using amperometric sensor of polyaniline doped with ferrocenesulfonic acid.

The result of cyclic voltammetry shows that polyaniline doped with ferrocenesulfonic acid (PAnFc) can effectively catalyze the oxidation of hydrogen peroxide, so PAnFc is used as a sensor to determine the concentration of H2O2. Iron in the ferrocenesulfonic acid exists in two oxidation states: Fe2+ and Fe3+. They can reversibly oxidize and reduce between the Fe2+ and Fe3+ oxidation states, which play an important role in the catalytic oxidation of H2O2. The response current of the sensor depends on the pH, applied potential and temperature at a given concentration of H2O2. At optimum conditions, the sensor has a fast response to H2O2, good operational stability, a good linear response to H2O2 in the range from 4 to 64 microM, and a small temperature dependence of the response current.

Aniline Compounds↗

Amperometric biosensor for hydrogen peroxide based on ferrocene-bovine serum albumin and multiwall carbon nanotube modified ormosil composite.

A novel amperometric biosensor for hydrogen peroxide (H(2)O(2)) was developed by entrapping horseradish peroxidase (HRP) in a new ormosil composite doped with ferrocene monocarboxylic acid-bovine serum albumin conjugate and multiwall carbon nanotubes (MWNTs). The ormosil was prepared using 3-(aminopropyl)triethoxysilane and 2-(3,4 epoxycyclohexyl)-ethyltrimethoxy silane as monomers. The encapsulated conjugate showed excellent electrochemistry and acted as an electron transfer mediator. The presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H(2)O(2). The proposed H(2)O(2) biosensor exhibited a linear range of 0.02-4.0 mM with a detection limit of 5.0 microM (S/N = 3) and a K(M)(app) value of 2.0 mM. It could be used for flow injection analysis of hydrogen peroxide with a liner range from 0.02 to 4.5 mM, sensitivity of 0.042 microA/mM and analytical time of 20 s per sample. This biosensor possessed good analytical performance and storage stability.

Adsorption↗

Enzyme electrodes based on sono-gel containing ferrocenyl compounds.

An amperometric-mediated glucose sensor has been developed by employing a silica sono-gel carbon composite electrode (SCC). The chosen mediators, ferrocene (Fc) and 1,2-diferrocenylethane (1), have been immobilized in the sono-gel composite matrix. The complex 1 has been employed for the first time as an electron transfer mediator for signal transduction from the active centre of the enzyme to the electrode conductive surface. After the optimisation of the construction procedure the best operative conditions for the analytical performance of the biosensor have been investigated in terms of pH, temperature and applied potential. Cyclic voltammetric and amperometric measurements have been used to study the response of both the glucose sensors, which exhibit a fast response and good reproducibility. The sensitivity to glucose is quite similar (6.7+/-0.1 microA/mM versus 5.3+/-0.1 microA/mM) when either Fc or 1 are used as mediators as are the detection limit ca. 1.0 mM (S/N=3) and the range of linear response (up to 13.0 mM). However, the dynamic range for glucose determination results wider when using 1 (up to 25.0 mM). The apparent Michaelis-Menten constants, calculated from the reciprocal plot under steady state conditions, are 27.7 and 31.6 mM for SCC-Fc/GOx and SCC-1/GOx electrodes, respectively, in agreement with a slightly higher electrocatalytic efficiency for the mediator 1.

Aspergillus niger↗

Dual electrochemical determination of glucose and insulin using enzyme and ferrocene microcapsules.

Dual electrochemical determination of glucose and insulin has been developed, based on enzymatic reaction and immunoassay with utilization of ferrocene microcapsules, respectively. Glucose was determined through electrochemical oxidation of formed product, hydrogen peroxide, by the action of glucose oxidase (GOx). The layer-by-layer (LbL) films on the ferrocene microcrystal followed by anti-insulin antibody sensitization were employed for the biolabled ferrocene microcapsules production. The antibody sensitized ferrocene microcapsules worked as a probe in the proposed system. The microcapsules provided a higher signal generating molecule to antibody (S/P) ratio of 4.52x10(6) to 12.4x10(6). Microcapsules with different antibody loads (388-1070 antibody molecules per capsule) were subjected to a solid-phase immunoassay for the detection of insulin. The microcapsule having 1030 anti-insulin antibody molecules per capsule demonstrated good performance for insulin determination. The calibration curve for insulin had a linear range of 10(-10) to 10(-7) g mL(-1) with R(2)=0.990, 3.9% R.S.D. The limit of detection for insulin was 10 pg mL(-1) of 100 microL sample (equivalent to 10(-12)g of insulin). The determination range for the glucose was 0.5 and 40 mM with R(2)=0.996 and 4.1% R.S.D.

Biosensing Techniques↗

Layer-by-layer hydroxymethyl ferrocene modified sensor for one-step flow/stop-flow injection amperometric immunoassay of alpha-fetoprotein.

A rapid one-step flow/stop-flow injection amperometric immunoassay for alpha-fetoprotein (AFP) using a novel home-produced electrochemical sensor was proposed. The sensor was prepared using layer-by-layer adsorption of positively charged poly(allylamine) (PAA) and negatively charged hydroxymethyl ferrocene on a screen-printed electrode (SPE). The electrochemistry of the immobilized ferrocene moieties showed a surface-controlled electrode process. Based on an electrochemical enzyme-linked immunoassay with the immobilized ferrocene moieties as an electron transfer mediator between the electrode and the horseradish peroxidase (HRP)-labeled anti-AFP antibody, a calibration curve with two linear ranges from 5 to 20 and 20 to 150 ng ml-1 and a detection limit of 2 ng ml-1 for AFP determination was obtained under the optimized conditions of 0.891 ml min-1 flow rate, 20 microl injection volume and +25 mV applied potential. The sensor showed good repeatability and reproducibility and retained more than 95% of its original signal after 15 days of storage. The proposed method eliminated the need for washing and addition of any substrate or mediator. The complete assay could be handled in less than 25 min with a one-step injection of a 40 microl sample solution. The proposed method would be valuable for the diagnosis and monitoring of carcinoma and its metastasis.

Biosensing Techniques↗