Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

An accurate technique for detailed prostatic interstitial temperature-mapping in patients receiving microwave thermal treatment.

A minimally invasive prostatic interstitial temperature-mapping technique is described that supplies accurate, detailed information on thermal doses delivered to precisely localized tissue sites. The technique employs a comparatively large numbers of thermosensors, highly accurate placement of those thermosensors at specified three-dimensional coordinates, fiberoptic technology that avoids significant interaction between the thermosensors and the applied microwave field, and continuous temperature readout. Biplane ultrasound imaging and fluoroscopy were used to ensure stereotactic accuracy of thermosensor placement. The technique was applied in 15 patients with benign prostatic hyperplasia (BPH) undergoing a 1-hour microwave thermal treatment session. The thermal mapping procedures and microwave treatment were generally well tolerated. The mean maximum temperature in the prostate and periprostatic tissue (57.9 +/- 1.9 degrees C) was significantly higher (P < 0.001) by more than 18 degrees C than that in either the urethra (39.6 +/- 0.9 degrees C) or the rectum (40.8 +/- 1.7 degrees C). In a representative patient, microwave treatment resulted in stable elevation of temperature 5 mm radially from the urethra that averaged 66.0 +/- 0.1 degrees C. At 10 mm from the urethra, the temperature averaged 50.5 +/- 0.1 degrees C. Urethral and rectal temperatures remained at innocuous levels. In conjunction with pathologic studies, this interstitial thermal mapping method should prove useful in defining the optimal thermal doses for microwave therapy. The method should also find uses in evaluating different microwave treatment systems, which can vary markedly in thermal performance, as well as other modalities that apply heat to prostatic tissue.

Aged↗

Green tea catechins protect rats from microwave-induced oxidative damage to heart tissue.

We investigated the effects of green tea catechin on oxidative damage in microwave-exposed rats. The microwave-exposed rats received one of three diets: catechin-free (MW-0C), 0.25% catechin (MW-0.25C), or 0.5% catechin (MW-0.5C). Rats were sacrificed 6 days after microwave irradiation (2.45 GHz, 15 minutes). Cytochrome P(450) levels in the MW-0C group was increased by 85% compared with normal, but was 11% and 14% lower in the MW-0.25C and MW-0.5C groups than in the MW-0C group. NADPH-cytochrome P(450) reductase activity in the MW-0C group was increased by 29%, compared with the normal group, but was significantly less in the MW-0.25C and MW-0.5C groups. Superoxide dismutase activity in the MW-0C group was decreased by 34%, compared with the normal group, but in the MW-0.25C and MW-0.5C groups was 19% and 25% higher. The activity of glutathione peroxidase in the MW-0C group was decreased by 28% but remained near normal with catechin supplements. Superoxide radical concentrations in the MW-0C group were increased by 35%, compared with the normal group. However, superoxide radicals in the MW-0.25C and MW-0.5C groups were 11% and 12% lower, respectively, compared with the MW-0C group. Microwave irradiation significantly increased levels of thiobarbituric acid-reactive substances, carbonyl values, and lipofuscin contents, but green tea catechin partially overcame the effects of the microwave irradiation. In conclusion, the mixed function oxidase system was activated, the formation of superoxide radical, lipid peroxide, oxidized protein, and lipofuscin was increased, and the antioxidative defense system was weakened in heart tissue of microwave-exposed rats, but the oxidative damage was significantly reduced by catechin supplementation.

Animals↗

Miscarriages among female physical therapists who report using radio- and microwave-frequency electromagnetic radiation.

Physical therapists are exposed to radio- and microwave-frequency electromagnetic radiation by operating shortwave and microwave diathermy units. Recent studies suggest that use of shortwave diathermy is associated with an excess risk of birth defects, perinatal deaths, and late spontaneous abortions among the offspring of exposed female therapists. To assess the impact of occupational use of microwave and shortwave diathermy at the time of conception, the authors mailed questionnaires to 42,403 physical therapists in 1989. Both occupational and reproductive histories were obtained. Exposures to shortwave and microwave diathermy were both assessed in the same fashion and were examined in relation to early recognized fetal loss in a nested case-control design. A total of 1,753 case pregnancies (miscarriages) were matched to 1,753 incidence density control pregnancies (other pregnancies except ectopic pregnancies). A pregnancy was considered "exposed" if the mother reported using microwave or shortwave diathermy anytime during the 6 months prior to the first trimester or during the first trimester. Pregnancies of mothers reporting microwave use 6 months prior to the pregnancy or during the first trimester were more likely to result in miscarriage (odds ratio (OR) = 1.28, 95% confidence interval (CI) 1.02-1.59). The odds ratio increased with increasing level of exposure (chi 2 = 7.25, p < 0.005). The odds ratio in the highest exposure group (20 or more exposures/month) was 1.59. The overall odds ratio was slightly lower after it was controlled for prior fetal loss (OR = 1.26, 95% CI 1.00-1.59), but the exposure-response effect remained (chi 2 = 5.17, p < 0.01). The risk of miscarriage was not associated with reported use of shortwave diathermy equipment (OR = 1.07, 95% CI 0.91-1.24). The odds ratio in the highest exposure group was 0.87.

Abortion, Spontaneous↗

Microwave thermography--an index of inflammatory joint disease.

Microwave thermography is a technique measuring microwave emission from sites of inflammation. Microwaves have a wavelength of around 10 cm and are therefore able to penetrate clinically useful depths of up to 4 cm directly measuring tissue thermal radiation. A microwave detector was applied to the study of joint inflammation in rheumatoid arthritis and in a normal control group. Fifty-two knees were scanned using the detector and a microwave thermographic index was calculated for each knee. A strong correlation was found between the microwave thermographic index, and the clinical and laboratory parameters measured. This technique was found to be reproducible, quick, simple to use at the bedside without a controlled environment and, since it measures internally emitted radiation, is inherently safe.

Arthritis, Rheumatoid↗

Microwave treatment enhances detection of RNA and DNA by in situ hybridization.

The use of oligonucleotide probes with nonisotopic detection systems has made in situ hybridization (ISH) more accessible for use in diagnostic pathology; however, ISH using formalin-fixed, paraffin-embedded tissues remains much more sensitive when performed with radioactively labeled probes compared with nonisotopic reporter systems, especially using oligonucleotide probes. We investigated the effects of microwave pretreatment on the detection of RNA and DNA in formalin-fixed, paraffin-embedded tissues in an attempt to improve the sensitivity of ISH with digoxigenin-labeled probes. Titration of normal tissues with oligonucleotide probe cocktails for albumin, prolactin, chromogranin (Cg) A and B mRNAs and a cDNA probe for JC virus showed a significant increase in sensitivity with the use of microwave treatment step rather than heating at 70 degrees C in 2 x SSC for 30 min. Analysis of various solutions used for microwaving showed that 10 mM citrate buffer was more effective than 2 x SSC, phosphate-buffered saline, tissue unmasking fluid, or water. A 15- to 20-min period of microwaving in an 800-W oven produced optimum results. Analysis of a group of tumors for albumin and CgA and B mRNAs and infected brain biopsies for JC virus DNA showed increased sensitivity of the microwave technique using digoxigenin-labeled probes. These results show that microwave treatment can enhance the detection of mRNA and DNA in formalin-fixed, paraffin-embedded tissues.

DNA↗

Abnormal cardiovascular responses induced by localized high power microwave exposure.

A hypothesis of microwave-induced circulatory under perfusion was tested in ketamine anesthetized rats whose heart rate, mean arterial pressure, pulse pressure, respiration rate, and body temperatures were monitored continuously. Fifty-eight ventral head and neck exposures in a waveguide consisted of sham-exposure and exposure to continuous wave (CW) and pulsed 1.25 GHz microwaves for 5 min. The 0.5 Hz (10 microseconds, 2 W average) and 16 Hz (1 microsecond, 6.4 W average) pulse-modulated microwaves were delivered at 400 kW peak power. The CW microwaves were 2 and 6.4 W. The average specific absorption rate was 4.75 W/kg per watt transmitted in the brain and 17.15 W/kg per watt transmitted in the neck. Respiration rate and mean arterial pressure were not altered. Changes in heart rate and pulse pressure were observed in rats exposed to higher power (16 Hz pulses and 6.4 W CW) but not to the lower average power microwaves (0.5 Hz pulses and 2 W CW). Depression of pulse pressure, an indication of a decrease in stroke volume, and increased (tachycardia) or decreased (bradycardia) heart rate were noted in presence of whole-body hyperthermia. The cardiac output of those animals exposed to higher average power microwaves was considered to be below normal as hypothesized. Decreased cardiac output and normal mean arterial pressure resulted in an increase in the total peripheral resistance which was contrary to the anticipated thermal response of animals.

Animals↗

Microwave exposure increases bone demineralization rate independent of temperature.

There is a long-standing controversy regarding an effect of microwaves, independent of increasing temperature, on the rate of bone demineralization. In this study, we exposed standardized samples of gerbil femur to constant microwave exposure while maintaining the demineralizing solution (ethylenediamine tetraacetic acid, EDTA) at 20 degrees C. Random samples were selected at 3 h intervals, embedded in plastic and sectioned for histological evaluation to determine the extent of demineralization. The time to complete demineralization was significantly faster with microwave exposure (33 h) compared to non-exposure on a tissue rotator (45 h) in a limited amount (5 mL/24 h) of EDTA. The presence of bone marrow was a significant barrier to the rate of demineralization and resulted in an asymmetrical pattern of mineral extraction. Samples without bone marrow were completely demineralized after 21 h of exposure to microwaves and EDTA. Additional comparisons were made between samples exposed to an effectively infinite supply of demineralizing agent (bone marrow intact). There was a significant increase in rate with unlimited demineralizing agent with (24 h) or without (30 h) microwaves when compared to tissue demineralized on the rotator. Our results establish a positive effect of microwaves on the rate of bone demineralization which is independent of temperature.

Animals↗

The influence of microwave radiation on transdermal delivery systems.

It has been alleged that the exposure of a transdermal delivery system to leakage of microwave radiation from a domestic microwave oven can result in the user receiving a second-degree burn in the area of the patch. Several transdermal delivery systems were exposed to microwave radiation from an Electro Medical Supplies Microtron 200 microwave diathermy unit. Temperature rises of up to 2.2 degrees C were recorded at a maximum power density of 800 W/m2. These temperature rises were considered insignificant compared to that required to produce a burn. The exposure of transdermal delivery systems to a microwave diathermy field or lower level leakage radiation from a microwave oven is unlikely to cause direct thermal injury to the wearer.

Administration, Cutaneous↗

Microwave endometrial ablation: development, clinical trials and outcomes at three years.

OBJECTIVE: To describe the introduction of microwave endometrial ablation to clinical practice, and to report the outcomes three years after endometrial ablation. DESIGN: A clinical trial using prototype microwave endometrial ablation equipment. SETTING: District general hospital. POPULATION: Forty-three women with completed families and with failed medical management for menorrhagia were treated with microwave endometrial ablation between October 1994 and April 1995. MAIN OUTCOME MEASURES: A statement of perceived menstrual loss and satisfaction supported by a menstrual symptom questionnaire score. Dysmenorrhoea was graded as a measure of described severity. Treatment time. RESULTS: Forty-three women had a total of 46 treatments. Mean treatment time: n = 43, was 141 seconds (50-310). Amenorrhoea: n = 16; 37.2%. Very light periods/discharge: n = 11; 25.6%. Improved periods and woman satisfied: n = 9; 20.9%. Improved periods and woman not satisfied: n = 1; 2.3%. Overall satisfaction at three years is 83.7%. Moderate (55.8%) or severe (27.9%) dysmenorrhoea pre-operatively had improved to 11.6% and 6.8% respectively at three years. Three re-treatments and four hysterectomies will be discussed. CONCLUSIONS: Microwave endometrial ablation is a new treatment for dysfunctional uterine bleeding using the application of microwave energy to the endometrium. This results in a rapid but restricted depth of intrauterine heating avoiding hysteroscopic fluid, operative haemorrhage and earthing risks. The technique is simple to learn and perform. Women report a high level of satisfaction three years after microwave endometrial ablation.

Adult↗

Microwave and thermal balloon ablation for heavy menstrual bleeding: a systematic review.

OBJECTIVE: To compare the effectiveness of two second generation endometrial ablation techniques (microwave and thermal balloon endometrial ablation) with first generation techniques of endometrial ablation to treat heavy menstrual bleeding in women. SEARCH STRATEGY: We searched the Cochrane Library (issue 3, 2002), the National Research Register, MEDLINE (1966 to August 2002), Embase (1980 to August 2002) and Web of Science Proceedings (all years). We also searched reference lists and contacted experts and manufacturers in the field. SELECTION CRITERIA: Randomised controlled trials and controlled trials of microwave endometrial ablation and thermal balloon endometrial ablation versus transcervical resection and rollerball ablation, alone or in combination, to treat heavy menstrual bleeding were included. DATA COLLECTION AND ANALYSIS: Two reviewers independently selected studies for inclusion and extracted data. As there was considerable clinical and methodological heterogeneity among the studies, meta-analysis was not undertaken and results are presented descriptively. RESULTS: Two randomised controlled trials of microwave endometrial ablation and eight trials (six randomised controlled trials) of thermal balloon endometrial ablation were included in the review. No significant differences were found between first and second generation techniques in terms of amenorrhoea, bleeding patterns, pre-menstrual symptoms, patient satisfaction or quality of life. Microwave endometrial ablation and thermal balloon endometrial ablation had significantly shorter operating and theatre times than first generation techniques. Adverse effects were few with all techniques, but there were fewer peri-operative adverse effects with second generation techniques. CONCLUSION: Microwave endometrial ablation and thermal balloon endometrial ablation are alternatives to first generation techniques for treating heavy menstrual bleeding. No head-to-head trials of microwave endometrial ablation and thermal balloon endometrial ablation have been undertaken and there is not yet enough evidence of differences in clinical effectiveness between these two techniques.

Catheter Ablation↗

Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation.

INTRODUCTION: Radiofrequency current delivered during cardiac ablation is limited by a rise in impedance secondary to coagulum formation on the ablation electrode. Microwave antennas continue to deliver energy despite the presence of coagulum; thus, temperature control of the ablation electrode may be even more important for microwave than for radiofrequency ablations to avoid thromboembolic risks. The purpose of this study was to test the safety and efficacy of an ablation system utilizing a feedback control system to maintain a fixed target temperature for creating lesions with multiple applications of microwave energy. METHODS AND RESULTS: Microwave ablation was assessed using an 8.5-French catheter at 2 to 4 sites in 11 dogs. Microwave energy delivery was performed for 60 seconds three times at the same site. Power was regulated using a feedback control mechanism to maintain a target temperature of 75 degrees C. Ambulatory ECG monitoring was performed before and after ablation to assess arrhythmia occurrence. After follow-up, the dogs were euthanized, and lesion dimensions measured after fixation. The mean power applied to achieve the target temperature of 75 degrees C was 9.3+/-44 W. The mean depth of the lesions was 8.8+/-4.2 mm. The mean volume of the lesions was 304+/-240 mm3. Forty-four percent of the lesions were transmural. No endocardial thrombus was found. Ventricular tachycardia was observed acutely but resolved after 1 week. CONCLUSION: Temperature feedback control systems for microwave ablation using a temperature-controlled system is feasible for myocardial ablation and creates uniform and large lesions; however, such large lesions can be acutely proarrhythmic.

Animals↗

Microwave cyclodestruction: evaluation on human eyes.

AIMS: The study was set up to evaluate the effect of microwave cyclodestruction on human eyes. METHODS: Two human eyes were studied. For treatment a horn shaped 5.8 GHz microwave applicator and fibre optic thermometry were used. Just before enucleation, the rectangular (2 x 3 mm) microwave aperture was placed onto the conjunctiva at a position 1-2 mm posterior to the corneal scleral limbus. Each of three to four treatment spots was targeted to receive a thermal dose of 54 degrees C for 1 minute. Clinical, gross, and histopathological evaluations were performed. RESULTS: Clinical evaluations of the treatment sites (immediately after microwave application) revealed no evidence of conjunctival or scleral damage. Trace fluorescein 2% uptake was noted within the targeted zones. The first eye was sectioned along the equatorial axis. Examination of the ciliary body and pars plana revealed whitening of the ciliary processes and depigmentation. Histopathological evaluations revealed ciliary epithelial necrosis with pigment dispersion. The vascularity of the ciliary processes showed focal disruption and haemorrhage. The underlying ciliary muscle and sclera appeared to be unaffected. No other findings could be attributed to microwave cyclodestruction. CONCLUSION: The results of this phase I toxicity study suggest that microwave heating can be used to damage preferentially the epithelial layers of the human ciliary body.

Aged↗

Transurethral microwave treatment for benign prostatic hypertrophy: a randomised controlled clinical trial.

OBJECTIVES: To determine whether transurethral microwave treatment for patients with benign prostatic hypertrophy provides significant symptomatic relief, a reduction in residual urine volumes, and improvements in flow rates compared with sham treatment. DESIGN: Prospective double blind randomised study with follow up at three months. SETTING: Department of Urology in a London teaching hospital. PATIENTS: 40 men completed the study: 22 received microwave treatment and 18 received sham treatment. Entry criteria were symptoms of prostatism of at least six months' duration, a total symptom score > 14, and a peak urine flow rate < 15 ml/s or a residual urine volume > 50 ml. Exclusion criteria were prostatic cancer, a residual urine volume > 200 ml, a very large prostate, an obstructing middle lobe, acute urinary retention, impaired renal function, coexisting urinary tract disease, and previous prostatic surgery. INTERVENTIONS: A single 90 minute transurethral microwave treatment or sham treatment. OUTCOME MEASURES: Patients' symptoms (including daytime frequency and nocturia) recorded in a self assessment symptom score questionnaire, peak urinary flow rates, and residual urine volumes. RESULTS: The mean total symptom scores of the patients who received microwave treatment fell from 30 to 11 compared with a fall from 31 to 26 for patients who received sham treatment (p < 0.001). Among patients who received microwave treatment daytime frequency fell from 9.4 to 5.5 voids a day and night time frequency from 3.5 to 1.6 voids a night; residual urine volumes fell from 104 ml to 52 ml; and peak urine flow rates increased by 2.3 ml/s. In the control group there was no improvement in any of these features. Treatment preserved sexual function and antegrade ejaculation. CONCLUSIONS: For selected patients with prostatism microwave treatment is effective and has few side effects.

Double-Blind Method↗

Microwave antigen retrieval in immunocytochemistry: a study of 80 antibodies.

AIMS: To evaluate the effect of microwave irradiation on the staining quality of a range of commonly used primary antibodies in archival, formalin fixed, paraffin wax embedded material, with emphasis on antibodies that have previously worked successfully only on frozen tissue. METHODS: Immunocytochemistry (streptavidin-biotin complex technique) was performed on histological sections of a range of normal and pathological tissues, after varying treatment with microwave irradiation. The staining quality of each antibody was compared with that achieved without prior treatment of the sections or after enzyme predigestion. RESULTS: Microwave irradiation permitted successful immunostaining with 20 antibodies that stained only frozen tissues before. The staining characteristics of 21 antibodies that were already known to stain formalin fixed, paraffin wax embedded material were improved. Another 39 antibodies did not show enhanced staining with microwave irradiation. The method preserves tissue morphology and produces more consistent staining than that achieved by enzyme predigestion with many antibodies. Microwave irradiation may also allow some primary antibodies to be used at higher working dilutions. The citrate buffer used in this study avoids the necessity of exposure to heavy metal salts. CONCLUSIONS: Microwave antigen retrieval represents an important technical advance within immunocytochemistry that will greatly increase the range of antibodies which can be used to study formalin fixed, paraffin wax embedded tissues.

Antibodies, Monoclonal↗

Microwave ablation: principles and applications.

Microwave ablation is the most recent development in the field of tumor ablation. The technique allows for flexible approaches to treatment, including percutaneous, laparoscopic, and open surgical access. With imaging guidance, the tumor is localized, and a thin (14.5-gauge) microwave antenna is placed directly into the tumor. A microwave generator emits an electromagnetic wave through the exposed, noninsulated portion of the antenna. Electromagnetic microwaves agitate water molecules in the surrounding tissue, producing friction and heat, thus inducing cellular death via coagulation necrosis. The main advantages of microwave technology, when compared with existing thermoablative technologies, include consistently higher intratumoral temperatures, larger tumor ablation volumes, faster ablation times, and an improved convection profile. Microwave ablation has promising potential in the treatment of primary and secondary liver disease, primary and secondary lung malignancies, renal and adrenal tumors, and bone metastases. The technology is still in its infancy, and future developments and clinical implementation will help improve the care of patients with cancer.

Adolescent↗

Adjustments in metabolic heat production by squirrel monkeys exposed to microwaves.

Squirrel monkeys (Saimiri sciureus) were exposed in the far field of a horn antenna to both brief (10-min) and prolonged (90-min) periods of 2,450-MHz continuous microwaves. Ambient temperature (Ta) was constant at 15, 20, or 25 degrees C. Microwave power density ranged from 2.5 to 10 mW/cm2, representing a range of whole-body energy absorption from 0.4 to 1.5 W/kg. Reliable reductions in metabolic heat production (M), calculated from oxygen deficit in the monkey's expired air, were initiated at all Ta by 10-min whole-body exposures to power densities of 4 mW/cm2 (2 monkeys) or 6 mW/cm2 (1 monkey) and above. The magnitude of M reduction was linearly related to microwave intensity above the threshold level. Termination of microwaves was followed by a rapid M rebound. The change in M produced by a given power density was nearly the same in Ta = 15 and 20 degrees C. During 90-min exposures at Ta = 20 degrees C, the vigorous M reduction to microwave onset adapted slowly, ensuring continual precise regulation of internal body temperature. Thus cold-exposed endotherms readily compensate for microwave-induced body heating by reducing endogenous heat production.

Animals↗

Microwave imaging of the breast.

Microwave imaging for medical applications has been of interest for many years. Recently, microwave imaging for breast cancer detection has gained attention due to advances in imaging algorithms, microwave hardware and computational power. The breast is relatively translucent to microwaves, accessible for imaging, and there appears to be a significant electromagnetic property contrast between tumors and healthy tissues. Therefore, breast imaging may be the first clinically viable application of microwave imaging. This paper reviews recent developments in passive, hybrid, and active approaches to microwave breast cancer detection.

Breast Neoplasms↗

Hepatic microwave ablation with multiple antennae results in synergistically larger zones of coagulation necrosis.

BACKGROUND: Microwave ablation is a promising treatment for unresectable liver tumors. Unlike radiofrequency ablation, microwave ablation may be performed with multiple simultaneously active antennae. METHODS: Microwave ablation was performed in an in vivo porcine liver model by using a single antenna (n = 11) or three antennae in a triangular array, activated either sequentially (n = 11) or simultaneously (n = 13). Lesions were measured and assigned a qualitative shape score. RESULTS: Single-antenna microwave lesions had a mean volume of 7.4 +/- 3.9 cm(3), compared with 14.6 +/- 5.2 cm(3) and 43.1 +/- 4.3 cm(3) for sequential and simultaneous multiple-probe ablations, respectively (P <.001; analysis of variance). Simultaneous lesions were rounder than sequential ablations and were more effective near blood vessels. Simultaneous lesions created with probe separation of < or =1.7 cm were round and confluent, whereas clefts were present with distances >1.7 cm (P <.001). CONCLUSIONS: Microwave ablation has several theoretical advantages over currently available radiofrequency devices. Simultaneous three-probe microwave ablation lesions were three times larger than sequential lesions and nearly six times greater in volume than single-probe lesions. Additionally, simultaneous multiple-probe ablation results in qualitatively better lesions, with more uniform coagulation and better performance near blood vessels. Simultaneous multiple-probe ablation may decrease inadequate treatment of large tumors and decrease recurrence rates after tumor ablation.

Animals↗