At least 379 records · Page 21Linked to original sources

Separation and determination of methyl tert-butyl ether and its degradation products by a laboratory-constructed micro-cryogenic chromatographic oven.

A laboratory-made micro-cryogenic chromatographic oven was mainly improved in size, which was controlled at 6 x 6 x 2.5 cm. A thermoelectric system was used to cool the capillary column instead of the traditional liquid cryogen. A cold block connected to the cryogenic module was directly solidified at room temperature with thermally conductive adhesive so that the uniformity of transferring heat was greatly improved, and the size of the system was reduced. Moreover, this system was inexpensive and convenient for both operation and control. The newly developed device coupled with headspace solid-phase microextraction (SPME) was successfully applied to the determination of methyl tert-butyl ether (MTBE) and its degradation products. During the analysis procedure, a 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used to extract MTBE and its degradation products. The extraction was controlled at 50 degrees C for 30 min and the NaCl content in the sample was maintained at 35%. The limits of detection (LODs) ranged from 0.006 microg mL(-1) (for MTBE) to 0.206 microg mL(-1) (for methyl acetate) and the relative standard deviations (RSD%) were below 4%. The spiked recoveries for the developed method were evaluated using various water samples as a matrix.

Chromatography↗

Verapamil drug metabolism studies by automated in-tube solid phase microextraction.

Verapamil is a common calcium antagonist described with antianginal, antihypertensive and antiarrythmic properties. The metabolites of verapamil have also shown pharmacological properties and therefore sample preparation and analysis techniques capable of metabolic screening for verapamil are important. In-tube SPME is a relatively new method integrating sample extraction, concentration and introduction into one single step without the use of organic solvents. The capability of in-tube SPME in bioanalysis has been reviewed but there has been no application described in the field of drug metabolism. Since automation and interfacing of in-tube SPME coupled to liquid chromatography-mass spectrometry (LC-MS) is possible, we confirm in this study that it is a powerful method to monitor the main metabolites of verapamil in various biological matrices like plasma, urine and cell culture media. Further, we show that it could also be used in routine pharmacokinetics measurements. An in-tube SPME LC-MS method was developed to extract and analyze the metabolic profile of verapamil from biological matrices. The detection limit for verapamil, gallopamil, norverapamil and PR22 were 52, 53, 65 and 83 ng/ml (UV detection) and 5, 6, 6 and 8 ng/ml (MS detection), respectively. The precision of the method was calculated in various biological matrices and the average % R.S.D. (N=5) for verapamil, gallopamil, norverapamil and PR22 was 3.9, 3.7, 3.8 and 4.3% (MS detection), respectively. The linear dynamic range was determined to be 100-800 ng/ml (UV detection) with a total sample preparation and analysis time of 34 min.

Animals↗

Sorptive sample preparation -- a review.

Most sample-enrichment procedures currently available rely on adsorption of the analytes of interest by a suitable adsorbent material. Although good performance can be obtained for many practical problems, in some cases the applicability of adsorptive sample preparation falls short, particularly for the enrichment of polar and/or high-molecular-weight compounds, especially in combination with thermal desorption. Because of the very strong retention of adsorbent materials, undesired effects such as incomplete desorption and artifact formation are observed. Polar solutes are easily adsorbed but readily undergo surface-catalyzed reactions and on desorption yield compounds different than those originally sampled. High-molecular-weight compounds cannot be desorbed because of extremely strong interactions with the adsorbent and their low volatility. To overcome some of these problems sample-preparation techniques based on polydimethylsiloxane sorption have been developed over the past 15 years. In contrast with adsorptive trapping, sorption is based on dissolution of the analytes in a liquid polymeric material. This is a much more inert means of solute retention which overcomes some of the limitations encountered when working with adsorbents. In this contribution, the basic principles of sorption, the different instrumentation used, and applications of the technique will be reviewed. The review covers the sorptive sample-preparation techniques, open-tubular trapping (OTT), solid-phase microextraction (SPME), gum-phase extraction (GPE), equilibrium gum-phase extraction (EGPE), and stir-bar-sorptive extraction (SBSE). Because of the nature of sorptive sample-preparation techniques, which perform particularly well in combination with thermal desorption, this review focuses strongly on gas chromatography as the means of chemical analysis.

Chromatography, Gas↗

A simple method for detecting plasma propofol.

IMPLICATIONS: We measured plasma propofol levels by head space-gas chromatography analysis using solid-phase microextraction. This method saves time, and does not require elimination of interfering substances in the plasma. The coefficient variation was +/-5% to +/-30%. The detection limit was 10 ng/mL.

Anesthetics, Intravenous↗

Solid-phase microextraction fibre-water distribution constants of more hydrophobic organic compounds and their correlations with octanol-water partition coefficients.

Fibre coating-water distribution constants (Kfw) of more hydrophobic chemicals were determined with six different solid-phase microextraction fibre types (including a polyoctylmethylsiloxane (C8) prototype) by fibre exposure to agitated large-volume water samples lasting several days. The results obtained are comparable with Kfw values obtained under dynamic conditions. Octanol-water partition coefficients (Kow) were measured with the mixture of distributing substances to examine log Kfw-log Kow relationships based on a consistent dataset. Kfw values obtained with liquid polymer fibre coatings correlate reasonably well with the hydrophobicity of the test compounds (with decreasing sensitivity in the following order: 7 microm polydimethylsiloxane (PDMS)>100 microm PDMS>C8>polyacrylate) whereas this is not the case with the PDMS-divinylbenzene (DVB) and Carbowax-DVB fibres, partially porous coatings which provide the highest Kfw values for all substances tested.

Octanols↗

Degradation of chlortoluron in water disinfection processes: a kinetic study.

The kinetics of the reaction between chlortoluron, a phenylurea herbicide [N'-(2-hydroxy-4-methyl-5-chlorophenyl)-N,N-dimethylurea], and hypochlorite, the active species in water disinfection processes involving chlorine, were investigated by HPLC-UV and HPLC-electrospray ionisation mass spectrometry (HPLC-ESI-MS). In particular, the concentrations of the main chlortoluron by-products were monitored as a function of time by HPLC-ESI-MS and a kinetic model was developed to fit the relevant curves. The results showed that chlortoluron degradation starts with two parallel pathways, namely, chlorination and hydroxylation of the aromatic ring, which are then followed by consecutive chlorination reactions, and after almost 2 weeks by ring opening and partial mineralisation, as confirmed by head-space solid-phase microextraction gas chromatography-MS (SPME-GC-MS) and total organic carbon (TOC) measurements. Kinetic constants for the first reactions of the overall process, under pseudo-first-order conditions (hypochlorite excess), were estimated by a fitting procedure.

Chromatography, High Pressure Liquid↗

Factors affecting multiresidue determination of priority herbicides when using solid-phase microextraction.

A solid-phase microextraction (SPME) procedure was developed for the determination of 10 selected organonitrogen herbicides (s-ethyl dibropylthiocarbamate [EPTC], molinate, propachlor, trifluralin, simazine, atrazine, propazine, terbuthylazine, alachlor, and prometryn) and was tested with various natural waters. Gas chromatography coupled with flame thermionic and mass spectrometric detection was used for quantitation. For this purpose, polydimethylsiloxane and polyacrylate fibers were used and the factors affecting the SPME process such as pH, ionic strength, methanol content, memory effect, stirring rate, and adsorption-time profile were investigated and optimized. By using spiked liquid chromatography water, optimal factors were determined to be 25% salt, <0.5% methanol, stirring rate of 960 rpm, pH 4, and an equilibrium time of 30 min. These conditions were used in further studies of the fibers and in analysis of natural water samples. The method was applied to spiked natural waters such as ground water, sea water, lake water, and river water at a concentration range of 0.5-10 microg/L. Limits of detection ranged from 5 to 90 ng/L, and precision ranged from 5 to 15% (as relative standard deviation), depending on the pesticide, fiber, and detector used. The recoveries of herbicides were 70.2-118.4%, and the average r2 values of the calibration curves were >0.99 for all analytes. The results demonstrate the suitability of the SPME method to determine these organonitrogen herbicides in various natural waters. River water samples originating from the Epirus region (Northwestern Greece) were analyzed to verify the performance of the optimized method by comparing the results obtained by SPME with those obtained by using conventional solid-phase extraction of the selected herbicides.

Calibration↗

Sample preparation with fiber-in-tube solid-phase microextraction for capillary electrophoretic separation of tricyclic antidepressant drugs in human urine.

Solid-phase microextraction (SPME) is a solvent-free sample preparation technique using a thin coating attached to the surface of a fused silica-fiber as the extraction medium, which has been successfully applied to the analysis of a wide variety of compounds by coupling to gas chromatography (GC). In recent years, in-tube SPME using GC capillary column as the extraction medium has also been developed and coupled with liquid chromatography (LC) for the preconcentration of nonvolatile compounds. In this study, an on-line interface between the fiber-in-tube SPME and capillary electrophoresis (CE) has been developed, and the preconcentration and separation of four tricyclic antidepressant (TCA) drugs, amitriptyline, imipramine, nortriptyline, and desipramine, were performed with the hyphenated system. Under the optimized condition, a better extraction performance than conventional in-tube SPME was obtained, even the length of the extraction medium was much shorter. The results clearly indicated that the fiber was working effectively as an extraction medium. For the separation of these four TCAs, capillary electrophoretic separation with beta-cyclodextrin as the buffer additive has been employed and the application of the developed system to the analysis of complex sample mixtures in a biological matrix is also demonstrated.

Amitriptyline↗

Solid-phase microextraction for the analysis of biological samples.

Solid-phase microextraction (SPME) has been introduced for the extraction of organic compounds from environmental samples. This relatively new extraction technique has now also gained a lot of interest in a broad field of analysis including food, biological and pharmaceutical samples. SPME has a number of advantages such as simplicity, low cost, compatibility with analytical systems, automation and the solvent-free extraction. The last few years, SPME has been combined with liquid chromatography and capillary electrophoresis, besides the generally used coupling to gas chromatography, and has been applied to various biological samples such as, e.g., urine, plasma and hair. The objective of the present paper is a survey of the application of SPME for the analysis of biological samples. Papers about the analysis of biologically active compounds are categorised and reviewed. The impact of SPME on various analytical fields (toxicological, forensic, clinical, biochemical, pharmaceutical, and natural products) is illustrated. The main features of SPME and its modes are briefly described and important aspects about its application for the determination of pharmaceuticals, drugs of abuse and compounds of clinical and toxicological interest are discussed. SPME is compared with other sample pretreatment techniques. The potential of SPME and its main advantages are demonstrated. Special attention is paid to new trends in applications of SPME in bioanalysis.

Chromatography, Liquid↗

Determination of organic compounds in water using dispersive liquid-liquid microextraction.

A new microextraction technique termed dispersive liquid-liquid microextraction (DLLME) was developed. DLLME is a very simple and rapid method for extraction and preconcentration of organic compounds from water samples. In this method, the appropriate mixture of extraction solvent (8.0 microL C2Cl4) and disperser solvent (1.00 mL acetone) are injected into the aqueous sample (5.00 mL) by syringe, rapidly. Therefore, cloudy solution is formed. In fact, it is consisted of fine particles of extraction solvent which is dispersed entirely into aqueous phase. After centrifuging, the fine particles of extraction solvent are sedimented in the bottom of the conical test tube (5.0 +/- 0.2 microL). The performance of DLLME is illustrated with the determination of polycyclic aromatic hydrocarbons (PAHs) in water samples by using gas chromatography-flame ionization detection (GC-FID). Some important parameters, such as kind of extraction and disperser solvent and volume of them, and extraction time were investigated. Under the optimum conditions the enrichment factor ranged from 603 to 1113 and the recovery ranged from 60.3 to 111.3%. The linear range was 0.02-200 microg/L (four orders of magnitude) and limit of detection was 0.007-0.030 microg/L for most of analytes. The relative standard deviations (RSDs) for 2 microg/L of PAHs in water by using internal standard were in the range 1.4-10.2% (n = 5). The recoveries of PAHs from surface water at spiking level of 5.0 microg/L were 82.0-111.0%. The ability of DLLME technique in the extraction of other organic compounds such as organochlorine pesticides, organophosphorus pesticides and substituted benzene compounds (benzene, toluene, ethyl benzene, and xylenes) from water samples were studied. The advantages of DLLME method are simplicity of operation, rapidity, low cost, high recovery, and enrichment factor.

Chromatography, Gas↗

Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples.

The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.

Acetic Acid↗

Toluene induces rapid and reversible rise of hippocampal glutamate and taurine neurotransmitter levels in mice.

Toluene, a widely used aromatic organic solvent, has been well characterized as a neurotoxic chemical. Although the neurobehavioral effects of toluene have been studied substantially, the mechanisms involved are not clearly understood. Hippocampus, which is one of the limbic areas of brain associated with neuronal plasticity, and learning and memory functions, may be a principal target of toluene. In the present study, to establish a mouse model for investigating the effects of acute toluene exposure on the amino acid neurotransmitter levels in the hippocampus, in vivo microdialysis study was performed in freely moving mice after a single intraperitoneal administration of toluene (150 and 300 mg/kg). Amino acid neurotransmitters in microdialysates were measured by a high performance liquid chromatography system. The extracellular levels of glutamate and taurine were rapidly and reversibly increased within 30 min after the toluene administration in a dose-dependent manner and returned to the basal level by 1h. Conversely, the extracellular level of glycine and GABA were stable, and no significant change was observed after the toluene administration. To further investigate the brain toluene level in the hippocampus of toluene-administered mice, we used a solid-phase microextraction (SPME) method and examined the time course changes of toluene in the hippocampus of living mice. The brain toluene level reached the peak at 30 min after injection and returned to the basal level after 2h. In the present study, we observed the relationship between brain toluene levels and amino acid neurotransmitter glutamate and taurine levels in the hippocampus. Therefore, we suggest that toluene may mediate its action through the glutamatergic and taurinergic neurotransmission in the hippocampus of freely moving mice.

Animals↗

Evolution of solid-phase microextraction technology.

The main objective of this contribution is to describe the development of the concepts, techniques and devices associated with solid-phase microextraction, as a response to the evolution of understanding of the fundamental principles behind this technique. The discussion begins with an historical perspective on the very early work conduced almost a decade ago. As new fundamental understanding about the functioning of the technology developed, new ways of constructing and using the SPME devices evolved.

Chromatography, Liquid↗

Establishment of long-term preservation for dimethyl sulfide by the solid-phase microextraction method.

Dimethyl sulfide (DMS) derived from marine biological activity affects radiative forcing of the climate. The general analytical technique for DMS in seawater (purge and trap analytical method, P&T) is complex onboard ship. Thus it is difficult to obtain sufficient data for a comprehensive understanding of the spatiotemporal variability of DMS in the sea surface layer. On the other hand, a new analytical method for DMS using SPME (solid-phase microextraction) has recently been developed as an alternative method to P&T. This method is simpler than P&T because no special or complex apparatus is needed. If it is possible to preserve DMS for an extended period in excess of the duration of the cruise, the SPME method is a promising method for measuring DMS in seawater. We assessed an analytical method which can allow us to preserve DMS on the long-term scale using SPME. In liquid nitrogen (-196 degrees C), as preserved environment, for a period of 20 days after sampling, we found the preservation rate of DMS to be 94.7 +/- 4.4% (n = 6) in this study. Furthermore, estimating the distribution coefficient with respect to the effect of salinity on SPME, we found that DMS changed by 0.1 nM/% sal, suggesting that salinity has only a minor influence on oceanic DMS measurements in the open ocean because the minimal change of the open ocean salinity is within 2 %. Applying the SPME method to open ocean samples, we found that there were no significant differences in DMS between the unpreserved and preserved samples (r = 0.99, n = 26, SE = 0.01, p < 0.0001), showing the SPME method has potential for use for open ocean surveys.

Chromatography, Liquid↗

Tequila volatile characterization and ethyl ester determination by solid phase microextraction gas chromatography/mass spectrometry analysis.

Solid phase microextraction (SPME) and gas chromatography were used for tequila volatile characterization and ethyl ester quantitation. Several factors determined the differences in tequila volatile profiles obtained by the SPME technique, namely, sampling mode, fiber coating, and fiber exposure time. Each of these factors determined the most suitable conditions for the analysis of volatile profiles in tequila. Volatile extraction consisted of placing 40 mL of tequila in a sealed vial kept at 40 degrees C. A poly(dimethylsiloxane) fiber was immersed in the liquid for 60 min and desorbed for 5 min into the gas chromatograph. The identified volatiles by mass spectrometry were mainly alcohols, esters, and ketones. The calibration curves for ethyl hexanoate, octanoate, and decanoate followed linear relationships with highly significant (p < 0.001) determination coefficients (R2 = 0.99). The coefficients of variation of less than 10% for ethyl ester concentrations indicated that the technique was reproducible. The limits of quantitation for ethyl esters were 0.05 parts per million, which were below the concentration range (0.27-15.03 ppm) found for different tequila samples. Quantitative differences in ethyl esters were found for the four most commonly known tequila types: silver, gold, aged, and extra-aged.

Alcoholic Beverages↗

A simple microthermal desorption device.

A new method for thermal desorption of small samples is presented. The method uses a solid phase microextraction (SPME) holder with the fiber removed. The sample-for example, an ink sample on paper-is simply placed inside the needle of the holder, where normally an SPME fiber is positioned. The thermal desorption is then performed on any kind of gas chromatograph in a manner similar to that for SPME analysis. The needle of the SPME holder penetrates the injector septum; the temperature of the thermal desorption is simply the temperature of the injector. No solvents or liquid nitrogen cooling are used. The paper sample is kept inside the holder needle during the analysis. After the analysis is completed, the sample is removed from the needle by pushing forward the steel wire inside the needle in the way normally used to perform sampling with the SPME fiber. The desorbed compounds were analyzed by gas chromatography with a flame ionization detector or by gas chromatography-mass spectrometry. The optimum temperature for desorption of ink samples on paper was 200 degrees C. The influence of the paper matrix is negligible at that temperature. Laboratories lacking the commercial device for thermal desorption can use this cheap device for the analysis of, for example, writing ink, printing ink, and inkjet ink samples on paper. Other types of samples can be investigated but the size of samples suitable for analysis is limited.

Journal Article↗

Headspace solid phase microextraction (SPME) analysis of flavor compounds in wines. Effect of the matrix volatile composition in the relative response factors in a wine model.

The application of headspace solid phase microextraction (SPME) for flavor analysis has been studied. Headspace SPME sampling was tested for nine common wine flavor compounds in 10% (v/v) aqueous ethanol: linalool, nerol, geraniol, 3-methyl-1-butanol, hexanol, 2-phenylethanol, ethyl hexanoate, ethyl octanoate, and ethyl decanoate. The chemical groups (monoterpenoids, aliphatic and aromatic alcohols, and esters) showed specific behavior in SPME analysis. SPME sampling parameters were optimized for these components. Relative response factors (RRFs), which establish the relationship between the concentration of the compound in the matrix liquid solution and the GC peak area, were estimated for all compounds. Log(10)(RRF) varied from 0 (3-methyl-1-butanol) to 3 (ethyl decanoate), according to their molecular weight. Quantification by SPME was shown to be highly dependent on the matrix composition; the compounds with higher RRF were the less affected. As a consequence, the data obtained with this methodology should be used taking into consideration these limitations, as shown in the analysis of four monovarietal Bairrada white wines (Arinto, Bical, Cerceal, and Maria Gomes).

Chromatography, Liquid↗