Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dentin Permeability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Influence of specimen size and regional variation on long-term resin-dentin bond strength.

OBJECTIVES: Verify whether the dimension of a bonded specimen stored prior microtensile testing and its regional variation may affect the resin-dentin bond strength (BS) over time. METHODS: Thirty human third molars had a flat dentin surface exposed and all peripheral enamel removed. Two adhesive systems (Single-Bond and One-Step) were applied and composite resin crowns (Z250) were constructed. Teeth were divided into three groups (n = 5). Group A specimens were sectioned to obtain sticks to be tested in tension (0.5 mm/min) immediately. Group B specimens were stored in water for 6 months, before sectioning and testing. Group C specimens were sectioned; the sticks were stored for 6 months and tested. In groups A and B, the origin of the sticks, periphery and inner regions was controlled. Bond strength (BS) was expressed as an index that considers cohesive failures and estimated values of premature debonded specimens. One-way ANOVA and Tukey's test (alpha = 0.05) were used to compare groups A, B and C, and a second analytical approach (A and B) employed a two-way ANOVA (time versus regional differences) for each adhesive system. RESULTS: For Single-Bond (SB), the BS for specimens in group A was higher than for groups B and C. For One-Step (OS), the BS in group A was higher than for B, which was in turn higher than for C. In the second group approach, no difference was found when the test was performed immediately; however, after 6 months, the inner sticks from group B showed significantly higher BS. SIGNIFICANCE: (1) The amount of decrease in BS is dependent on the specimen size; (2) the decrease in BS was greater for peripheral specimens than more centrally located specimens.

Analysis of Variance↗

Mechanical stability of resin-dentin bond components.

OBJECTIVES: To evaluate the effects of long-term storage on the mechanical properties of the components of resin-dentin bonds, that is, resin composite, adhesive system, demineralized and mineralized dentin. METHODS: Specimens of resin composite (Z250) and adhesive systems (Single Bond-SB; One-Step-OS and Clearfil Liner Bond 2V-CL) were cast in molds. Dentin specimens were prepared from dentin discs obtained from the crowns of extracted human molars. Specimens of demineralized dentin were obtained by immersion of dentin discs for 6 days in 0.5 mol/l EDTA (pH 7.0). Both dentin and resin-based substrates were shaped to hourglass or I-beam specimens that were used to determine the true stress (TS) or apparent modulus of elasticity (E), respectively. Control specimens were subjected to tensile testing at 0.6 mm/min after 24 h of immersion in distilled water. Experimental specimens were stored at 37 degrees C in either distilled water or mineral oil and tested after 12 months. The data of each group were individually analyzed by ANOVA and Tukey's test. RESULTS: Both TS and E of the resin-based materials decreased significantly after 12 months of storage in water (p < 0.05) except the TS of SB (p > 0.05). No changes were observed for specimens of mineralized dentin, regardless of storage condition (p > 0.05). Storage of demineralized dentin in water did not cause any significant effect in either TS or E (p > 0.05), however, significant reductions of TS and E of demineralized dentin occurred after storage in oil for 1 year (p < 0.05). SIGNIFICANCE: Storage time and medium may be deleterious to the mechanical properties of the resin-dentin bond components, which ultimately could compromise the durability of resin-dentin bonds.

Analysis of Variance↗

Effects of etching time of primary dentin on interface morphology and microtensile bond strength.

OBJECTIVES: To determine the influence of different etching times (5, 15 or 30 s) on the morphology and micro-tensile bond strength (muTBS) of primary dentin. METHODS: For muTBS study, nine primary molars were randomly distributed in three experimental groups. Three Class I cavities per tooth were drilled and etched (37% orthophosphoric acid gel for 5, 15 or 30 s). Excite adhesive was applied and cavities restored with a resin composite (Tetric Ceram). Composite/dentin bars (ca. 1 mm2 section) were obtained from teeth and tested in tension until debonding. Means of muTBS results were compared with ANOVA and Student-Neuman-Keuls post hoc tests. Morphology: Three occlusal cavities were prepared in five primary molars. Each cavity was etched and restored as described for previous groups and teeth were sectioned mesio-distally. One half of each tooth was prepared for using under optical microscopy using Masson's trichromic dye technique and the other half was examined by SEM. RESULTS: muTBS mean (S.D.) results (in MPa) were 5 s etch: 6.20 (2.81), 15 s: 13.43 (5.91), 30 s: 13.04 (5.67). muTBS groups were Excite 5 s < Excite 15 s = Excite 30 s. Masson's trichromic technique stained the demineralized dentin layer red in all specimens. The mean (S.D.) thickness of the demineralized layers (in mu) were 5 s: 3.28 (1.23), 15 s: 3.83 (1.26), 30 s: 4.44 (1.70). There is a statistically significant linear relationship between time of application of etching and mean depth of demineralized layer. This relationship was established as depth (in mu) = 3.08 + 0.05 time (in s). SIGNIFICANCE: The minimum adequate etching time for primary dentin is 15s.

Acid Etching, Dental↗

Marginal adaptation and microtensile bond strength of composite indirect restorations bonded to dentin treated with adhesive and low-viscosity composite.

OBJECTIVES: This study evaluated the marginal adaptation of composite indirect restorations bonded with dual curing resin cement after different strategies to seal dentin. Different bonding techniques associated or not with a low-viscosity composite resin (LVCR) were utilized. In addition, the bond strength between composite resin and pre-sealed dentin was evaluated in the buccal and pulpal walls of class I cavities, prepared for indirect restorations. METHODS: Thirty-three freshly extracted human molars were used for this study, divided into three groups (n=11) representing different techniques to seal dentin-(Group 1) Conventional technique: the adhesive system was applied and polymerized just before the cementation of the indirect restoration; (Group 2) Dual bonding technique: a first layer of the adhesive system was applied and polymerized just after preparation, and a second layer just before the final cementation; (Group 3) Resin coating technique: a LVCR was applied and polymerized after the first layer of the adhesive system, and before the impression. A further application of the adhesive system was performed before the placement of the restoration. The restorations were polished and a solution of acid red propylene-glycol was dropped on each specimen's occlusal surface for 10 s. The dye penetrations were captured under stereoscopic lens and the images were transferred to a computer with a measurement program, in order to determine the extension of the dye penetration. The microtensile bond strength test (muTBS) was applied on pulpal (P) and buccal (B) walls of the restorations for Groups 1-3. The subgroups for muTBS were: Group 1P (n=13); Group 1B (n=7); Group 2P (n=6); Group 2B (n=14); Group 3P (n=14); Group 3B (n=15). All specimens were sectioned to obtain an area of 0.8 mm2. The specimens were mounted on a microtensile device and fractured using a universal testing machine at a cross-head speed of 1mm/min. Failure modes were analyzed by SEM. One-way ANOVA and multiple-comparison Tukey's test were used for statistical analysis of the marginal adaptation scores and muTBS test. Non-parametrical Kruskal-Wallis test was used for failure mode analysis. RESULTS: Group 3 showed a significantly higher mean value of marginal dye penetration (45.59) when compared to Groups 1 (8.44) and 2 (18.92). For pulpal walls, Group 1P showed significantly higher mean muTBS (25.93+/-2.27) when compared to Groups 2P (14.71+/-1.78) and 3P (16.07+/-2.81). There was no statistical difference between Groups 2P and 3P. For buccal walls, Group 2B presented significantly higher mean muTBS (23.29+/-1.42), and Group 1B the lowest mean values (11.37+/-1.14). The failure mode analysis presented a considerable variation, according to the treatment and to the wall. SIGNIFICANCE: The results of this study indicated that a previous sealing of dentin using the adhesive system, followed by a second application just before the cementation, is an effective alternative technique, since it maintains the marginal adaptation of indirect composite resin restorations, and improves the bond strength at the interface on buccal walls, which are the most critical regions for the long-term durability of these procedures.

Adhesives↗

Effectiveness and dentin bond strengths of two materials for reinforcing thin-walled roots.

OBJECTIVES: To investigate the effectiveness of two restorative materials for reinforcing thin-walled roots and their microtensile bond strengths to root canal dentin. METHODS: Twenty-one decoronated maxillary central incisor roots were root filled and the canals enlarged to leave approximately 1.0 mm thick dentin walls. The roots were distributed randomly to three equal groups. Group 1 (control): a large tapered cast post-core was fabricated. Group 2 (BIS-CORE): a thick layer of dual-cured composite was placed in the post-hole before fabrication of a small-diameter tapered cast post-core. Group 3 (ChemFil Superior): a thick layer of glass-ionomer was placed, as before. Metal-ceramic crowns were fabricated for all teeth. Microtensile bond strength tests and optical and atomic force microscope observations were employed to examine adhesion between the two restorative materials and the root canal dentin. RESULTS: Mechanical loading (kN) demonstrated that composite 0.64 (S.D. 0.05), but not glass-ionomer 0.49 (0.05), significantly reinforced the fracture resistance of thin-walled roots, P<0.001. Microtensile bond strengths (MPa) were 21.7 (1.6) for composite and 12.9 (1.7) for glass-ionomer, P=002. SIGNIFICANCE: A thick intermediate layer of resin-bonded composite, sandwiched between the root dentin and a small-diameter cast Ni-Cr post or dowel, increased significantly the fracture resistance of the roots.

Adult↗

Technique sensitivity associated with air-drying of HEMA-free, single-bottle, one-step self-etch adhesives.

OBJECTIVES: This study examined the effect of air-drying on bond strength to dentin and nanoleakage in resin-dentin interfaces using HEMA-free one-step self-etch adhesives. METHODS: Twelve teeth had their occlusal dentin exposed and split in half. In the group of G-BOND (GB), the adhesive was dried gently or vigorously on each slit half tooth, and then light-cured. In the group of the experimental adhesive (EX), three coats of adhesive were dried using a single air-drying process prior to light-curing or dried after each of three coats of adhesive before light-curing. The split specimens were built-up with resin composite and then subjected to microtensile bond strength testing and TEM examination. RESULTS: GB showed significantly higher bond strength after vigorous drying than after gentle drying. Three teeth of from EX group showed higher bond strength after triple drying than after single drying, while two teeth showed no significant difference. Droplets were revealed in the adhesive layer after gentle drying with GB, and silver deposits existed along the interfaces in all groups. SIGNIFICANCE: The bonding quality to dentin may be improved by using an accelerated air-drying technique; although it is impossible to remove intrinsic dentin moisture that is drawn upwards from dentin tubules.

Acid Etching, Dental↗

Electric device improves bonds of simplified etch-and-rinse adhesives.

OBJECTIVES: This study investigated the effects of an electric field produced by a new device for the application of etch-and-rinse adhesives on demineralized dentin surfaces. METHODS: Three simplified etch-and-rinse adhesives (Single Bond, Prime&Bond NT and One-Step) were applied with the electric device and compared with controls prepared with disposable sponges. Specimens were processed for microtensile bond strength test and nanoleakage investigation using high resolution SEM. RESULTS: Microtensile testing revealed higher bond strengths (p<0.05) for all adhesives tested when electricity was used. Adhesive interfaces prepared with electric impulses exhibited very homogenous hybrid layers with minimal nanoleakage compared with the controls. SIGNIFICANCE: The use of electricity produced by a new electronic device during the application of dentin adhesives may increase adhesive adaptation to the dentin substrate and improve dentin hybridization due to the substrate modifications induced by an electric field on the demineralized dentin organic matrix.

Bisphenol A-Glycidyl Methacrylate↗

A 2-year evaluation of moisture on microtensile bond strength and nanoleakage.

OBJECTIVES: This study evaluated the effect of moisture on the resin-dentin mu-bond strength (BS) and silver nitrate uptake (SNU) of three adhesive systems (Single Bond, One-Step and Syntac Single Component) soon after bonding (IM) and after 2 years of water storage (2Y). METHODS: Dentin surfaces were bonded on a dry (D), moist (W) or over-wet surfaces (OW). After restorations were constructed, specimens were stored in water (37 degrees C/24h). Resin-dentin sticks were prepared (0.8mm(2)) and they were divided for immediate (IM) and 2-year storage (2Y) testing. Half of the specimens from each period of time were tested in tension at 0.5mm/min and the other half was immersed in silver nitrate and examined by SEM-EDX. The data was analyzed by three-way repeated measures ANOVA and Tukey's tests (alpha=0.05). RESULTS: The overall BS (MPa) in the IM group under W condition was higher than in D and OW groups. After 2Y, the BS in W was lower than in the IM group, however higher than in the D and OW for OS and SB. The overall silver nitrate deposition (%) in the IM group under D, W and OW were similar. In the 2Y groups, the nanoleakage was higher than IM groups, however the increase was less pronounced in the W condition. SIGNIFICANCE: Higher BS and a significantly lower nitrate uptake were observed for IM groups, for OS and SB. Under W conditions, the BS reduction over time was less pronounced and less nitrate uptake occurred.

Absorption↗

Interfacial characteristics of adhesive luting resins and composites with dentine.

PURPOSE: To evaluate the interfacial characteristics of five adhesive resin luting agents with dentine including tensile bond strength, failure mode, extent of demineralisation, morphological changes and hybrid layer formation. MATERIALS AND METHODS: The products tested were Bistite II DC (BDC), C&B Super-Bond (CBM), M-Bond (MBD), Panavia-F (PAF) and Rely-X Unicem (RXU). For tensile bond strength measurements (TBS), metallic rods were bonded to standardised dentine surface areas (n=10), thermal-cycled (3000x 5-55 degrees C, 4 cycles/min) and debonded at 1mm/min crosshead speed. The failure mode was examined on dentine surfaces by LV-SEM (n=10), whereas the thickness of the hybrid layer by HV-SEM (n=4). FT-IR microscopy (n=4) and ESEM (n=4) were used to assess the extent of demineralisation and the morphological changes induced on dentine by the conditioning and priming treatments. RESULTS: TBS (MPa) values were BDC (13.01), MBD (9.19) and PAF (7.07) significantly different from CBM (4.79) and RXU (4.47). The percentage of debonded dentine area covered with resin showed the highest values in BDC (47.80) and MBD (38.12) significantly different from CBM (17.20), PAF (16.47), and RXU (16.50). The extent of demineralisation for CBM was 100%. No statistical differences were found among BDC (60.86%), MBD (60.22%) and PAF (51.99%). RUX (45.03%) showed the lowest value. CBM induced the most pronounced tubule funneling and intertubular dissolution, followed by PAF, BDC and MDB. RXU partially removed the smear layer without opening tubule orifices. The thickest hybrid layer was found in CBM (4.17microm) followed by MBD (2.39microm). No statistically significant differences were found between PAF (0.95microm) and BDC (1.12microm), whereas RXU showed no detectable hybrid layer. SIGNIFICANCE: Significant differences were found in the interfacial properties among the materials tested, that may lead to differences in their clinical performance.

Analysis of Variance↗

Durability of resin-dentin bonds: effects of direct/indirect exposure and storage media.

OBJECTIVES: To evaluate the longevity of resin-dentin bonds of three adhesives using different storage media and specimen size. METHODS: Flat dentin surfaces from extracted human third molars were bonded with: a two-step etch-and-rinse self-priming adhesive (Single Bond), a two-step self-etching adhesive (Clearfil SE Bond), and a one-step self-etching adhesive (One-Up Bond F). Composite build-ups were constructed. The bonded teeth were stored under three conditions: dry, distilled water, or mineral oil. Half of the specimens were stored as intact bonded teeth (Indirect Exposure/IE). The other half were first sectioned into beams and stored under same conditions (Direct Exposure/DE). After storage periods of 24h, 3 months or 1 year, the intact teeth (IE) were sectioned into beams and both subgroups (DE and IE) were tested for microtensile bond strengths. Results were analyzed with multiple ANOVA and Student-Newman-Keuls tests. Fractographic analysis was performed by SEM. RESULTS: After 24h, Single Bond and Clearfil SE Bond performed equally and were superior to One-Up Bond F. After 3 months of DE to water storage, decreases in bond strengths were observed for Single Bond and One-Up Bond F, this decrease occurred for Clearfil SE Bond after 12 months of water storage. Bonded specimens aged in dry did not alter bond strengths over time. Bond strength increased when Single Bond was stored in mineral oil after 3 and 12 months. Micromorphological alterations were evident after water storage. SIGNIFICANCE: Although dentin bond strength of all the adhesives fell over time in DE, SE Bond fells the least.

Acid Etching, Dental↗

Effect of remaining demineralised dentine on dental microleakage accessed by a dye penetration: how to inhibit microleakage?

OBJECTIVES: To demonstrate that microleakage has taken place at the defect, which was analysed previously by a tensile test using dumbbell shaped specimens trimmed from bonded resin/dentine restorations, and to suggest how microleakage can be inhibited reliably in dental treatment. METHODS: A total of 60 Class V box cavities were prepared at the cemento-enamel junction on fresh bovine incisors and randomly divided into four groups of 15 specimens each. Exposure times of etching for 10:3 conditioner were set at 10, 30 or 60 s, and for 10% phosphoric acid (positive control) at 10 s. The cavity walls were rinsed with water for 10 s, air-dried for 10 s and hybridised with 4-META/MMA-TBB resin. All the cavities were filled with a light cured resin composite and stored in 37 degrees C water for 24 h and then immersed in 15% methylene blue for 2 h. The length of dye penetration along the interface was graded by defined criteria and analysed using Kruskal-Wallis and Mann-Whitney tests. The dye penetration patterns were examined by light microscopy and the remaining demineralised dentine was analysed by Transmission Electron Microscopy (TEM). RESULTS: The least leakage score was obtained in 10s-10:3 etched group with 12 out of 15 specimens demonstrating no leakage. Leakage was significantly lower at the cementum margin than for the other three groups. No significant difference in the extent of greatest dye penetration was found between the 60s-10:3 and 10s-phosphoric etched groups. Dye penetration along the cementum margins was significantly higher than that of the enamel margins in all groups, except the 10s-10:3 etched group. TEM examination confirmed that there were exposed collagen fibrils in the remaining demineralised dentine, where microleakage had taken place. SIGNIFICANCE: It could be concluded from this study that microleakage has taken place at the defect in the bonded specimens which has correlations with zones of incompletely infiltrated demineralised dentine that was observed using TEM. A reliable method of inhibiting microleakage is the presence of well prepared hybridised dentine.

Acid Etching, Dental↗

Shortening of primary dentin etching time and its implication on bond strength.

OBJECTIVE: The aim of this study was to investigate the influence of shortening the etching time on the bond strength of a conventional and a self-etching primer adhesive system used in primary tooth dentin. METHODS: Flat dentin surfaces were obtained from 24 primary molars, randomly assigned to 4 experimental groups. The adhesive systems Single Bond and Clearfil SE Bond were applied in two groups according to the manufacturers' recommendations. In the other two groups, the adhesives were applied after half-time of acid etching, 7 s for Single Bond and 10 s for Clearfil SE Primer. Resin crowns were built up and after 24 h storage in water at 37 degrees C, the teeth were sectioned to produce beams with cross-sectional area of approximately 0.49 mm2. Specimens were tested in tension at 0.5 mm/min until failure. Fractured specimens were analyzed to determine the failure mode. RESULTS: Tensile bond strengths for Single Bond in primary dentin were higher than for Clearfil SE Bond. Shortening of acid etching time improved bond strength only for Single Bond, while no statistically significant difference was observed for Clearfil SE Bond when both etching times were compared. SIGNIFICANCE: No detrimental effect on bond strength was observed when the time of acid etching was shortened in 50%. Shortening the time for a procedure in a small child without compromising the quality of the work is a very important finding for the practicing pediatric dentist.

Acid Etching, Dental↗

Use of fluorescent compounds in assessing bonded resin-based restorations: a literature review.

OBJECTIVES: This work reviews fundamental concepts involved with fluorescent imaging in the dental materials field. DATA: Fluorescent dyes have been widely used: incorporated into adhesive system components, placed in the pulp chamber and allowed to diffuse toward the restorative interface, as well as used as a visible tracer in microleakage tests. CONCLUSIONS: Although use of fluorescent imaging has substantially contributed to the existing knowledge base, there is no standardized methodology used, and as a result, interpretation of study results as well as comparison of results among studies remains questionable.

Composite Resins↗

Conditioning effect on dentin, resin tags and hybrid layer of different acidity self-etch adhesives applied to thick and thin smear layer.

OBJECTIVES: to assess the conditioning effect (CE) of self-etch adhesives of different acidity applied to thick and thin smear layer (SL), the corresponding resin tags (RT) and hybrid layer (HL). METHODS: Twenty-seven molars had their occlusal dentin exposed and were sectioned into two halves. Each of them was ground with a 60 or 600-grit SiC paper, respectively for thick and thin SL production. Three self-etch adhesives: a mild (Clearfil SE Bond), an intermediary (Optibond Solo SE and Solo Plus) and a strong (Tyrian Self Priming Etchant+One Step Plus) and an etch-&-rinse system (Scotchbond Multi Purpose Plus) were used. For CE evaluation, the self-etch primers were applied and rinsed off with acetone and alcohol prior to SEM preparation. For RT and HL specimens self-etch adhesives were applied and restored with Z-250. For RT specimens, dentin was removed with HCl (6N) and NaClO (1%) baths. The HL specimens were fixed, dehydrated, dried with HMDS, embedded, polished and slightly demineralized (6N HCl) and deproteinized (1% NaClO). After gold sputtering they were observed by SEM. RESULTS: The thick smear layer was clearly not totally removed by the mild self-etch primer. RT varied in density and shape among the self-etch adhesives. Thicker HL was observed for the strong self-etch and etch-&-rinse adhesives. CONCLUSIONS: The etch-&-rinse adhesive presented the thickest HL and was the only adhesive to produce RT in high density and uniform distribution along the whole dentin surface, independently of the SL thickness.

Acid Etching, Dental↗

The role of acrylophosphonic acid monomers in the formation of hybrid layers based on self-etch adhesives.

UNLABELLED: The role of acrylophosphonic acid monomers in the formation of hybrid layers based on self-etch adhesives. OBJECTIVES: Our plan was to define the reaction products formed when an acrylophosphonic acid reacts with tooth hard tissue. Our aim was to describe the incorporation of the reaction products in the hybrid layer formed. METHODS: Potentiometric methods were used to measure acid dissociation constants and investigate calcium complex formation. Infrared spectroscopy and NMR were used to follow water contents and show transformation of phosphorous containing compounds. RESULTS: The acrylophosphonic acid contained in AdheSE (Ivoclar Vivadent, Schaan, Liechtenstein) is characterized by two acidities with pK(a1)=2.4 and pK(a2)=7.0, and interacts with calcium ions in a purely ionic fashion. When hydroxyapatite crystals are dissociated by the presence of AdheSE, brushite is formed together with a calcium cross-linked network of the phosphonate containing copolymer. CONCLUSION: The results give a new image of the hybrid layer where the adhesive behaves like an ionomer resin incorporating collagen but also minerals and salt bridges.

Acid Etching, Dental↗

Adhesive dentistry and endodontics. Part 2: bonding in the root canal system-the promise and the problems: a review.

One of the recent trends in endodontics has been the development of bonded obturating materials, in an effort to provide a more effective seal coronally and apically. Materials utilizing dentin adhesive technology have been borrowed from restorative dentistry and adapted to obturating materials. This review discusses the obstacles to effective bonding in the root canal system, the progress that has been made, and possible strategies for improved materials in the future. Much of the literature reviewed and many of the principles discussed are taken from the restorative dentistry literature and applied to the unique environment of the root canal system.

Dental Bonding↗

Bond strength between root dentin and three glass-fiber post systems.

STATEMENT OF PROBLEM: Glass-fiber posts were introduced for use after endodontic therapy instead of metal alloy and ceramic posts. There are several new types of glass-fiber post systems available, but little is known about how well these posts bond to the root surface. PURPOSE: The purpose of this in vitro study was to compare the bond strengths of 3 different types of glass-fiber post systems-opaque, translucent, and electrical glass-in 3 different locations of prepared post spaces. MATERIAL AND METHODS: Sixty human intact single-rooted extracted teeth were used. The root canals were prepared using a step-back technique and obturated with gutta-percha using lateral condensation. The roots were divided into 3 experimental groups and further divided into 2 subgroups according to testing time (n=10). Roots were restored with 1 of the following post systems according to the manufacturer's instructions: opaque glass-fiber posts (Snowpost), translucent glass-fiber posts (FiberMaster), and electrical glass-fiber posts (Everstick). A self-etching primer (Clearfil Liner Bond) was applied to the walls of the post spaces, allowed to etch for 30 seconds, and gently air dried. A dual-polymerized bonding agent (Clearfil Liner Bond, Bond A and B) was then applied to the same walls. A dual-polymerizing resin luting agent (Panavia F) was mixed for 20 seconds and then placed in the post spaces using a lentulo spiral instrument. The roots were placed in light-protected cylinders; then the light source was placed directly on the flat cervical tooth surfaces and the cement was polymerized. Specimens were stored in light-proof boxes for 24 hours or 1 week after the polymerization procedure. Each root was cut horizontally, and six 1-mm-thick root segments (2 apical, 2 middle, and 2 cervical) were prepared. Using a push-out test, the bond strength between post and dentin was measured after 24 hours or 1 week using a universal testing machine. Statistical analysis was performed with 3-way ANOVA followed by independent t tests (alpha=.05) to detect differences between groups defined by the specific interacting variables. The different combinations of posts and luting material from the cervical segments were analyzed with SEM. RESULTS: The 3-way ANOVA indicated that push-out test values varied significantly according to the post system used (opaque, electrical, and translucent) (P<.01); the root segments (cervical, middle, and apical) (P<.01), however, did not vary statistically according to the time of testing (24 hours and 1 week). Opaque and electrical glass-fiber posts showed higher bond strength values than translucent posts (P<.01). Push-out bond strength values of cervical segments were significantly higher than the middle and apical segments in translucent and electrical glass-fiber post groups (P<.01). In the opaque glass-fiber post group, there were no significant differences between cervical and middle segments. In SEM analysis, a distinct hybrid zone with long, numerous resin tags located between luting material and dentin was exhibited in all post systems. CONCLUSION: The opaque and electrical glass-fiber posts exhibited similar bond strengths, and translucent posts exhibited the lowest bond strength. The highest bond strength was observed in the cervical third of the post spaces for translucent and electrical glass-fiber post groups.

Dental Bonding↗

Dentin bonding as a function of dentin structure.

The traditional principles of operative dentistry have been challenged since Dr. Buonocore introduced the aid-etch technique in 1955. In spite of the numerous changes in clinical protocols and adhesive techniques, adhesion to dentin remains difficult. The importance of micromechanical bonding to dentin has been recognized over the last decade. Researchers now believe that dentin adhesion relies primarily on the penetration of adhesive monomers into the filigree of collagen fibers left exposed by acid etching. Two main strategies are currently in use for bonding to enamel and dentin: the self-etch technique and the total-etch technique. The efficiency of either bonding strategy depends very much on the dentin substrate used for bonding. Laboratory tests use ideal dentin from extracted teeth, which does not reflect the clinical reality. Clinical studies are the ultimate test for any dental adhesive material.

Clinical Trials as Topic↗