Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Attachment of plasma membranes of cultured cells to silicon chips for high magnification imaging in scanning electron microscopy.

In the membrane preparation method described in this paper, a polylysine-coated silicon chip is adsorbed to the exposed apical surface of a cell monolayer. Upon removal, the adsorbed chip separates the plasmalemma from the residual bodies of the cultured cells. This sandwich-membrane separation approach simplifies access to the cytoplasmic aspects of both the apical and the basal plasmalemma which remains on the culture substrate and is covered to a varied extent by cytoplasmic infrastructures. To stabilize the attached membranes, small crosslinking agents are used in a controlled osmium impregnation. Large crosslinkers are avoided since they induce thickening of fine structures. Optimal conditions for attachment of plasmalemma of cultured adrenal endothelial cells to the cationic chip are defined. Effective cleaning procedures of the chips and useful molecular weights of polylysine are determined by quantitating colloidal gold adherence to the surface of the chips. The specimens are examined by high resolution scanning electron microscopy.

Adrenal Cortex↗

[Reduction of radical cavities by homologous cartilage chips].

The article reviews, first of all, the common obliteration methods of radical cavities. This is followed by a description of the author's own technique which has been practiced for the last 13 years. This method employs preserved (Cialit solution 1:5000) homologous septal cartilage chips, shaped into small cubes of 3-4 mm. size. The chips are implanted in obscure districts (apical mastoid, sinus dura angle) of radical cavities for primary or secondary (old cavities) partial obliteration, as shown in Figs. 1 and 2. Crushed homologous septal cartilage plates and temporal muscle fascia are placed additionally on the chips. The effect is the construction of a small, easy-care cavity, which can be appreciated at a glance. Statistical results of 314 cases (170 cases of primary obliteration, 144 old cavities) are presented. Chips in cavities are well tolerated. Chips were partially rejected in 13 cases only, whereas in 3 cases they were completely rejected. A permanent dry cavity and dry ear was achieved in 86% of the cases. Cholesteatoma recurred in 5 cases. The homologous cartilage technique is contraindicated in fistulas on the labyrinth or fenestra, as well as in exposed facial nerve or dehiscence of the facial nerve canal, in case of healed fistula of the dura, and in dissection of the sinus sigmoideus. In these cases, autologous cartilage (tragus, cavum conchae) must be implanted. One of the most important advantages of this method is that there is no crumpling up of the obliterated areas and no retractions over a longer period of time, compared with other relevant techniques (i.e., pedicled subcutis muscle grafts or free tissue flaps).

Cartilage↗

Vibration syndrome in chipping and grinding workers.

A clear conclusion from these studies is that vibration syndrome occurs in chipping and grinding workers in this country and that earlier reports that it may not exist were probably inaccurate. The careful selection of exposed and control groups for analysis strengthens the observed association between vibration syndrome and the occupational use of pneumatic chipping hammers and grinding tools. In the foundry populations studied the vibration syndrome was severe, with short latencies and high prevalences of the advanced stages. The shipyard population did not display this pattern. This difference can be attributed to variations in work practices but the more important factor seems to be the effect of incentive work schedules. Comparisons of groups of hourly and incentive workers from the shipyard and within foundry populations consistently demonstrated that incentive work was associated with increased severity of vibration syndrome. Excessive vibration levels were measured on chipping and grinding tools. Of the factors studied, reduction of throttle level decreased the vibration levels measured on chipping hammers. For grinders, the working condition of the tool affected the measured vibration acceleration levels. Grinders receiving average to poor maintenance showed higher vibration levels. The results of objective clinical testing did not yield tests with diagnostic properties. To date, the clinical judgment of the physician remains the primary focus of the diagnosis of vibration syndrome. A number of actions can be taken to prevent vibration syndrome. Preplacement medical examinations can identify workers predisposed to or experiencing Raynaud's phenomenon or disease. Informing employees and employers about the signs, symptoms, and consequences of vibration syndrome can encourage workers to report the condition to their physicians promptly. Engineering approaches to preventing vibration syndrome include increased quality control on castings to reduce finishing time and automation of the finishing process. Tool manufacturers can contribute by modifying or redesigning tools to reduce vibration. The technology to reduce vibration from hand tools exists but the engineering application is difficult. Vibration from chain saws has been reduced through changes in design and some companies have begun to redesign jackhammers, scalers, grinders, and chipping hammers. As these become available, purchasers can encourage manufacturers by selecting tools with antivibration characteristics. Vibration from tools currently in use can be controlled by periodically scheduled inspection and maintenance programs for vibrating tools.(ABSTRACT TRUNCATED AT 400 WORDS)

Equipment Design↗

[Emission of organic substances from chip-boards].

A relatively small number of investigations on emissions of organic substances from chip-board is available up to now. The emissions known to date are caused by glues or other additives rather than by the wood itself. As concerns aminoplast glues (urea-formaldehyde or melamine-formaldehyde resins) the most important point of public interest has been the off-gassing of formaldehyde from chip-board. Chip-board with phenol-formaldehyde glues has been known in some cases to give off phenol. The formation of diamino diphenyl methane from isocyanate glues is still a matter of discussion. A further source for possible emissions are wood and fire protectives which are added during the manufacturing process. Finally, coating of chip-board may lead to emissions of organic substances. The lack of adequate detection methods has so far delayed the treatment of questions in relation to emissions from chip-board. Even now, there are numerous problems in this field especially when investigating isocyanate glues. Problems in relation to the origin of emissions due to the kind of glue used and the manufacturing process are discussed, and proposals are made how to solve some of these problems. The question of the health risk is dealt with from the view-point of the civil engineer and in an general economic context.

Adhesives↗

Microbiological aspects of wood chip storage in tropical environments.

The microbiology of tropical wood chip storage has been examined in small experimental piles at two sites in New Guinea. Biodeterioration occurred in the forms of wood discoloration and loss of wood substance, including cellulosics; over a period of 2-4 months c. 20% per month of the chip pile by volume was seriously discoloured by microorganisms, and wood substance loss amounted to c. 1.5% per month (microscopic assessment). A range of microorganisms which produce discoloration were isolated. Decay was mainly due to soft-rotting microfungi such as Chaetomium globosum, C. thermophile, Humicola lanuginosa, Cephalosporium acremonium and Gliomastix subiculosa. Wood-rotting basidiomycetes were infrequent, although pockets of decayed (white rot) mycelial-matted chips were observed in the outer 1.5 m during dismantling of the 4-month-old pile at Vanimo. A successional trend of colonizing microorganisms was established, and profiles of the main zones of microbiological activity have been determined. The rapid rise in temperature, which is characteristic of wood chip piles after construction, had a marked influence on the microbial populations. Thermotolerant isolates included Humicola spp., Aspergillus spp., some actinomycetes, and members of the bacterial genus Bacillus. Reasonable chemical control of biodeterioration was achieved by dipping chip samples in a 1% solution of sodium pentachlorophenate. Three trichlorophenol formulations were less effective.

Alkaline Phosphatase↗

Exploring the Translation of Organ-on-a-Chip Technology for Human-Relevant Diagnostic Biomarkers.

Microphysiological systems (MPSs) are gaining traction as a viable alternative model for toxicity studies. Further characterization is necessary to explore the full translational potential of MPSs to human physiology, along with the utility of these platforms to serve as a diagnostic tool. Multiomics analyses have emerged as a key means for identifying host biomarkers associated with chemical and drug exposure. Correlations between published human omics and MPS technology omics data will inform the potential of organ chips to accurately represent human responses and provide an alternative approach for improved biomarker discovery for toxicity assessment and exposure identification. To interrogate these potential overlaps, TissUse Chip3 multiorgan chips (MOCs) seeded with kidney organoids, liver organoids, and respiratory tract tissue were exposed to low, therapeutic, and toxic doses of acetaminophen (n = 4 for each condition) for 24 h and subjected to proteomic and metabolomic analysis. The data from our organ chips are largely consistent with biomarkers and dysregulations identified in published human omics data, in vitro and in vivo data, to include the identification of several known acetaminophen metabolites and biotransformation products. These data suggest that organ chips may be a suitable surrogate for human biomarker identification and drug or hazardous chemical exposure diagnosis.

Humans↗

Measuring reaction kinetics in a lab-on-a-chip by microcoil NMR.

A microfluidic chip with an integrated planar microcoil was developed for Nuclear Magnetic Resonance (NMR) spectroscopy on samples with volumes of less than a microliter. Real-time monitoring of imine formation from benzaldehyde and aniline in the microreactor chip by NMR was demonstrated. The reaction times in the chip can be set from 30 min down to ca. 2 s, the latter being the mixing time in the microfluidic chip. Design rules will be described to optimize the microreactor and detection coil in order to deal with the inherent sensitivity of NMR and to minimize magnetic field inhomogeneities and obtain sufficient spectral resolution.

Imines↗

Application of surface biopassivated disposable poly(dimethylsiloxane)/glass chips to a heterogeneous competitive human serum immunoglobulin G immunoassay with incorporated internal standard.

A microfluidic platform for a heterogeneous competitive immunoassay of human immunoglobulin G (IgG) employing Cy5-human IgG as tracer and Cy3-mouse IgG as internal standard was developed. The device consisted of microchannels made of poly(dimethylsiloxane) and glass which were patterned with antibodies against human IgG and mouse IgG. Electrokinetic sample transport was employed in order to exploit the small difference between the net mobilities of analyte and tracer, thereby achieving favorable conditions for the performance of the competitive immunoreaction. The overall quality of the disposable chip and performance of the immunoassay were controlled by monitoring the fluorescence of bound tracer and bound internal standard. Analyses with an insufficient internal standard response were discarded, and immunoassay data evaluation was based on the ratio of tracer and internal standard fluorescence. Using synthetic samples in the range from 0 to 80 microg/mL IgG and alkaline running conditions, a concentration-dependent response with reproducible Cy5/Cy3 signal ratios (average relative standard deviation of 6.8%) was obtained. Chips stored with solution in the channels at 4 degrees C over a two-month period were found to perform like freshly prepared chips, whereas chips stored dry at -20 degrees C and rehydrated prior to use could not be employed. The analysis of patient sera showed that the immunoassay platform behaved differently in the presence of serum-based samples. Using the same conditions as for the synthetic samples, no concentration dependence was noted. With a large excess of tracer, however, an IgG concentration dependence was observed, permitting distinction of samples of patients with normal IgG serum levels (8-16 mg/mL) from those with elevated IgG concentrations (>16 mg/mL).

Animals↗

Immunoelectrophoresis of red blood cells performed on microcapillary chips.

Immunoanalysis of blood cells on a microcapillary electrophoresis (nuCE) chip has been studied using sheep erythrocytes (ShE) as an example. Two different buffer solutions, the phosphate-buffered saline (PBS) and the gelatin veronal buffer (GVB) were examined in regard to the electrokinetic transport behavior of ShE suspended in these solutions inside the rectangular channel engraved on a quartz chip. This clarified two advantages of the use of GVB for on-chip cell electrophoresis: gelatin coatings prevent (i) nonspecific sticking of ShE on the channel wall, and cause (ii) an appreciable reduction in the zeta potential of the wall suppressing the electroosmotic flow of the buffer solution. As a result ShE suspended in the GVB can smoothly migrate from the cathode to the anode, which is the opposite flow direction of immunoglobulin G (IgG) antibodies under the physiological pH condition of 7.4. Based on these results, on-chip capillary cell immunoelectrophoresis of ShE and rabbit anti ShE antibodies (IgG) have been proposed and successfully accomplished using the GVB. It is demonstrated that the variation of the cell migration velocity originating from the change in the surface charge after binding antibodies is applicable to the fast detection of immune reactions and also to single-cell typing.

Animals↗

Rapid analysis of protein interactions: On-chip micropurification of recombinant protein expressed in Esherichia coli.

We describe a rapid analysis of interactions between antibodies and a recombinant protein present in total cell lysates. Using a surface plasmon resonance biosensor, a low concentration of glutathione-S-transferase (GST) fused protein expressed in small scale Esherichia coli culture was purified on an anti-GST antibody immobilized sensor chip. The 'on-chip purification' was verified using matrix-assisted laser desorption/ionization-time of flight mass spectrometry by measuring the molecular masses of recombinant proteins purified on the sensor chip. The specific binding of monoclonal antibodies for the on-chip micropurified recombinant proteins can then be monitored, thus enabling kinetic analysis and epitope mapping of the bound antibodies. This approach reduced time, resources and sample consumption by avoiding conventional steps related to concentration and purification.

Blotting, Western↗

Analysis of drug action on tumor cell metabolism using electronic sensor chips.

Chemotherapeutic drugs affect the metabolism of tumor cells regardless of the specific target of action. Basic parameters of cell metabolism are extrusion of acids into the microenvironment and oxygen consumption. To analyze these changes on living cells in real-time, a test system based on multiparametric chips with an array of sensors for monitoring pH and O(2) as well as electric impedance has been developed. Cells are cultivated on these chips and supplied with medium by a fluid perfusion set-up which mimics microphysiological conditions and allows for drug addition and removal. Human colon carcinoma cells LS174T were used as a model to test the effect of drugs. Cells growing on chips were monitored for 24 h and longer. Untreated cells showed a continuous increase in the rate of acidification, while the rate of respiration remained fairly constant. Addition of chloroacetaldehyde (50 microM) rapidly attenuated O(2) consumption with a gradual decrease in acidification following. In contrast, with cisplatin (16.7 microM) a delayed and gradual decrease in both the rates of acidification and respiration effect occurred over 2-3 days. These results provide insights to the mechanisms of action of these drugs, which are coherent with those already known. Thus, multiparametric sensor chips provide elementary information on drug action.

Antineoplastic Agents↗

A microbial chip combined with scanning electrochemical microscopy.

A microbial chip for bioassay was fabricated and its performance was characterized by scanning electrochemical microscopy (SECM). The microbial chip was prepared by spotting a suspension of Escherichia coli on a polystyrene substrate by using a glass capillary pen. The respiration activity of the E. coli spot was imaged with SECM by mapping the oxygen concentration around the spot. The SECM images of the microbial chips clearly showed spots with lower reduction currents, indicating that E. coli in the spots uptake oxygen by respiration. The bactericidal effects of antibiotics (streptomycin and ampicillin) were measured using the E. coli-based microbial chip, and discussed in comparison with the minimum inhibitory concentration (MIC) determined by an agar plate dilution method.

Ampicillin↗

Automated chip-based nanoelectrospray-mass spectrometry for rapid identification of proteins separated by two-dimensional gel electrophoresis.

We report a method using a fully automated chip-based nanoelectrospray system for two-dimensional (2-D) gel sample analyses with mass spectrometric detection. The automated nanoelectrospray system, consisting of the NanoMate and electrospray ionization (ESI) chip, serves as both an autosampler and nanoESI source. This infusion system aspirates samples from a 96-well plate using disposable pipette tips and then delivers these samples sequentially to an ESI chip. This chip is a fully integrated monolithic device consisting of a 10x10 array of nozzles. The automated nanoelectrospray system is easily controlled through software, permitting the user to select the number of samples to be analyzed, the volume of sample to aspirate, the spray voltage, and analysis time. The system offers all the advantages of conventional nanoelectrospray plus automated, high-throughput analyses without analyte carryover. The system was used for a protein identification study of 2-D gel spots of both Escherichia coli and yeast crude cell extracts. The identification of 50 spots from E. coli crude cell extract and 27 spots from yeast extract is presented, demonstrating the powerful combination of the automated nanoESI system, the Thermo Finnigan LCQ Deca ion-trap mass spectrometer, and SEQUEST search software. In addition, the effects of silver staining and colloidal Coomassie blue staining of 2-D gel spots on the detection sensitivity and protein sequence coverage are compared and discussed. Furthermore, the comparison results using the multiwell microscale preparation kit versus manual extraction for in-gel samples are presented.

Animals↗

Chip electrospray mass spectrometry for carbohydrate analysis.

Currently two types of chip systems are used in conjunction with MS: out-of-plane devices, where hundreds of nozzles, nanospray emitters are integrated onto a single silicon substrate from which electrospray is established perpendicular to the substrate, and planar microchips, embedding a microchannel at the end of which electrospray is generated in-plane, on the edge of the microchip. In the last two years, carbohydrate research greatly benefited from the introduction and implementation of the chip-based MS. In two laboratories the advantages of the chip electrospray in terms of ionization efficiency, sensitivity, reproducibility, quality of data in combination with high mass accuracy, and resolution of detection were systematically explored for several carbohydrate classes: O- and N-glycopeptides, oligosaccharides, gangliosides and glycoprotein-derived O- and N-glycans, and glycopeptides. The current state-of-the-art in interfacing the chip electrospray devices to high-performance MS for carbohydrate analysis, and the particular requirements for method optimization in both positive and negative ion modes are reviewed here. The recent applications of these miniaturized devices and their general potential for glycomic-based surveys are highlighted.

Amino Acid Sequence↗

On the surface modification of microchannels for microcapillary electrophoresis chips.

This paper presents systematic investigation of the microchannel surface properties in microCE chips. Three popular materials for microCE chips, polydimethylsiloxane (PDMS), quartz, and glass, are used. The zeta potentials of these microchannels are calculated by measuring the EOF velocity to evaluate the surface properties after surface modification. The hydrophobic PDMS is usually plasma-treated for microCE applications. In this study, a new method using a high-throughput atmospheric plasma generator is adopted to treat the PDMS surface under atmospheric conditions. In this approach, the cost and time for surface treatment can be significantly reduced compared with the conventional vacuum plasma generator method. Experimental results indicate that new functional groups could be formed on the PDMS surface after treatment, resulting in a change in the surface property. The time-dependent surface property of the plasma-treated PDMS is then measured in terms of the zeta potential. Results show that the surface property will reach a stable condition after 1 h of plasma treatment. For glass CE chips, two new methods for changing the microchannel surface properties are developed. Instead of using complicated and time-consuming chemical silanization procedures for CE channel surface modification, two simple and reliable methods utilizing organic-based spin-on-glass and water-soluble acrylic resin are reported. The proposed method provides a fast batch process for controlling the surface properties of glass-based CE channels. The proposed methods are evaluated using PhiX-174 DNA maker separation. The experimental data show that the surface property is modified and separation efficiency greatly improved. In addition, the long-term stability of both coatings is verified in this study. The methods proposed in this study show potential as an excellent solution for glass-based microCE chip surface modification.

Bacteriophage phi X 174↗

Computer vision based analysis of potato chips--a tool for rapid detection of acrylamide level.

In this study, analysis of digital color images of fried potato chips were combined with parallel LC-MS based analysis of acrylamide in order to develop a rapid tool for the estimation of acrylamide during processing. Pixels of the fried potato image were classified into three sets based on their Euclidian distances to the representative mean values of typical bright yellow, yellowish brown, and dark brown regions using a semiautomatic segmentation algorithm. The featuring parameter extracted from the segmented image was NA2 value which was defined as the number of pixels in Set-2 divided by the total number of pixels of the entire fried potato image. Using training images of potato chips, it was shown that there was a strong linear correlation (r = 0.989) between acrylamide level and NA2 value. Images of a number of test samples were analyzed to predict their acrylamide level by means of this correlation data. The results confirmed that computer vision system described here provided explicit and meaningful description from the viewpoint of inspection and evaluation purpose for potato chips. Assuming a provisional threshold limit of 1000 ng/g for acrylamide, test samples could be successfully inspected with only one failure out of 60 potato chips.

Acrylamide↗

BIACORE analysis of histidine-tagged proteins using a chelating NTA sensor chip.

While BIACORE instruments are routinely used for kinetic measurements and for the determination of binding constants, the immobilization of a ligand onto the sensor chip surface has to be individually optimized for every system. We show here that the histidine (His) tag, routinely used in protein purification and in detection is an ideal tag for immobilization, despite the intrinsically low affinity between an immobilized metal ion and the His tag. This is due to strong rebinding effects caused by the high surface density of immobilized Ni2+-nitrilotriacetic acid (NTA) on the chips used here. The immobilization of the ligand can be adjusted to a low level using the same chip, such that mass transport limitation and rebinding of the analyte to the immobilized ligand is minimal. Nine different proteins with different numbers of His tags were tested for stable binding to the Ni2+-NTA surface. Most proteins with one His tag dissociate very rapidly from the Ni2+-NTA surface, and the KD for the interaction between His tag and Ni2+-NTA was estimated to about 10(-6) m at neutral pH. In contrast, two His tags are usually found to be sufficient for stable binding. The kinetics of the chaperonin system of Escherichia coli GroEL and GroES were analyzed as a model using this system and found to be very similar to those obtained with covalently immobilized ligands. The sensor chip can be reused many times, because of the powerful regeneration methods. The ligand can be freshly immobilized after each cycle, thus eliminating potential denaturation upon regeneration as a source of error.

Adenosine Triphosphate↗

A vesicle capture sensor chip for kinetic analysis of interactions with membrane-bound receptors.

A novel sensor chip for use in surface plasmon resonance (SPR) biosensors has been developed to capture vesicles which may contain membrane-bound receptors. Sulforhodamine-containing vesicles were shown by fluorescence microscopy to be immobilized intact on the sensor chip. Binding of cholera toxin to captured vesicles containing ganglioside GM(1) was demonstrated using SPR, and the derived kinetic and affinity constants were similar to literature values. Biotinylated vesicles captured on the sensor chip were used to bind streptavidin and then biotinylated ss-DNA. The hybridization of complementary ss-DNA to the immobilized ss-DNA was then analyzed using SPR. The values obtained were similar to those obtained for an identical interaction analyzed using a commercially available streptavidin-containing sensor chip. Binding of vancomycin-group antibiotics to captured vesicles containing a bacterial cell wall mucopeptide analogue was demonstrated. No binding of the bacterial endotoxin Cry1A(c) to captured vesicles containing its cell surface receptor could be demonstrated.

Animals↗