Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CT scan analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Can we predict poor outcome at presentation in patients with lobar hemorrhage?

OBJECTIVE: Supratentorial lobar hemorrhage can be devastating. Outcome prediction at presentation is important in triage and management decisions as well as appropriate resource utilization. We performed a decision tree analysis combining clinical and CT scan features to predict poor and hopeless outcome at initial presentation in patients with lobar hemorrhage. METHODS: We analyzed 81 patients with spontaneous lobar hemorrhage presenting within 48 hours of initial neurologic symptoms. In the first analysis, poor outcome was defined as Glasgow outcome score (GOS) of 1 (death), 2 (vegetative state) or 3 (dependence) at discharge. A second analysis was based on worst possible outcome (GOS 1-2). Binary recursive partitioning was fitted in a model, and odds ratios with 95% confidence intervals (CI) were calculated. RESULTS: Lobes involved were temporal (36%), parietal (33%), frontal (25%) and occipital (6%). Seventy-three percent of patients presented less than 17 h after initial ictus. The probability of poor outcome was 97% (CI 85-100%) in patients with hemorrhage greater than 40 cm(3). In the subset of patients with a volume less than 40 cm(3), time interval from ictus to presentation (< 17 h) together with a Glasgow coma score (GCS) less than or equal to 13 predicted poor outcome. Eighty-five percent (CI 42-99%) of those presenting early with GCS less than or equal to 13 had a poor outcome. In the second analysis, all patients with GCS less than or equal to 12 and septum pellucidum shift > 6 mm had GOS of 1 or 2 (CI 72-100%). CONCLUSION: Poor outcome in patients with lobar hemorrhage is associated with a hemorrhage size of more than 40 cm(3), GCS less than or equal to 13, but also dependent on time interval between ictus and presentation. This is consistent with prior studies demonstrating deterioration from enlargement may occur when patients present early on. Stupor and septum pellucidum shift greater than 6 mm on CT scan at presentation predict a hopeless outcome in conservatively treated patients. Ninety-one percent of patients were treated medically, thus these outcomes are largely a reflection of the natural history of spontaneous lobar hemorrhage. These signs may influence triage and management decisions.

Adolescent↗

Diagnosis of pneumonia with an electronic nose: correlation of vapor signature with chest computed tomography scan findings.

OBJECTIVES/HYPOTHESIS: The electronic nose is a sensor of volatile molecules that is useful in the analysis of expired gases. The device is well suited to testing the breath of patients receiving mechanical ventilation and is a potential diagnostic adjunct that can aid in the detection of patients with ventilator-associated pneumonia. STUDY DESIGN: A prospective study. METHODS: We performed a prospective study of patients receiving mechanical ventilation in a surgical intensive care unit who underwent chest computed tomography (CT) scanning. A single attending radiologist reviewed the chest CT scans, and imaging features were recorded on a standardized form. Within 48 hours of chest CT scan, five sets of exhaled gas were sampled from the expiratory limb of the ventilator circuit. The gases were assayed with a commercially available electronic nose. Both linear and nonlinear analyses were performed to identify correlations between imaging features and the assayed gas signatures. RESULTS: Twenty-five patients were identified, 13 of whom were diagnosed with pneumonia by CT scan. Support vector machine analysis was performed in two separate analyses. In the first analysis, in which a training set was identical to a prediction set, the accuracy of prediction results was greater than 91.6%. In the second analysis, in which the training set and the prediction set were different, the accuracy of prediction results was at least 80%, with higher accuracy depending on the specific parameters and models being used. CONCLUSION: The electronic nose is a new technology that continues to show promise as a potential diagnostic adjunct in the diagnosis of pneumonia and other infectious diseases.

Adult↗

Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature.

OBJECTIVE: Unenhanced CT scanning can reliably characterize incidentally detected adrenal masses when observers use density measurements of the adrenal gland. However, controversy exists as to the optimal density threshold required to differentiate benign from malignant lesions. This study attempts to establish a consensus by performing a pooled analysis of data found in the CT literature. MATERIALS AND METHODS: Ten CT reports were analyzed, from which individual adrenal lesion density measurements were obtained for 495 adrenal lesions (272 benign lesions and 223 malignant lesions). Threshold analysis generated a range of sensitivities and specificities for lesion characterization at different density thresholds. RESULTS: Sensitivity for characterizing a lesion as benign ranged from 47% at a threshold of 2 H to 88% at a threshold of 20 H. Similarly, specificity varied from 100% at a threshold of 2 H to 84% at a threshold of 20 H. CONCLUSION: The attempt to be absolutely certain that an adrenal lesion is benign may lead to an unacceptably low sensitivity for lesion characterization. The threshold chosen will depend on the patient population and the cost-benefit approach to patient care.

Adrenal Gland Diseases↗

[Computed assisted area measurement using CT scans: clinical application for craniosynostosis in children].

This paper describes a method for obtaining intracranial area measurements using CT scans with a software for quantitative analysis of tracing data. A Toshiba CT 1010 scanner was used (120 kv, 10 mm slice thickness) to examine 13 children before and after cranioplastic surgery for craniosynostosis. Using Scion Image (Scion Corporation) with Intuos tablet system (WACOM), the intracranial space was measured at approximately same scanning level. Our findings show that the reverse pi and bilateral canthal advancement procedures usually carried out are associated with increased intracranial area, 4.5 +/- 2.1% and 12.0 +/- 8.3%, respectively. This measurement method should be further modified to intracranial volume gain by several surgical procedures.

Craniosynostoses↗

Interpretation of CT scans with PACS image display in stack mode.

PURPOSE: To compare picture archiving and communication system (PACS) image display in so-called stack mode with conventional image display, tile mode, in efficacy of analysis of three-dimensional structure on computed tomographic (CT) scans. MATERIALS AND METHODS: A complex three-dimensional phantom composed of 20 entangled tubes was constructed and scanned. The resultant images were transferred to a PACS for analysis. Five experienced CT radiologists were asked to unravel the tubes by identifying their ends and to perform this task in both stack and tile modes. The time taken and any errors were recorded. RESULTS: All five radiologists performed considerably faster in stack mode than in tile mode; the speed varied by a factor of 3.2-5.7 times. The results of a paired t test showed this difference to be significant (P = .0002). Furthermore, no mistakes were made in stack mode, while two mistakes were made in tile mode. CONCLUSION: Stack mode facilitates analysis of three-dimensional structure depicted on CT scans.

Phantoms, Imaging↗

Prospective comparison of [18F]fluorodeoxyglucose positron emission tomography with conventional assessment by computed tomography scans and serum tumor markers for the evaluation of residual masses in patients with nonseminomatous germ cell carcinoma.

BACKGROUND: To assess the ability of [(18)F]fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET) to predict the viability of residual masses after chemotherapy in patients with metastatic nonseminomatous germ cell tumors (GCT), PET results were compared in a blinded analysis with computed tomography (CT) scans and serum tumor marker changes (TUM) as established methods of assessment. METHODS: Independent reviewers who were blinded to each other's results evaluated the PET results and corresponding CT scan and TUM results in 85 residual lesions from 45 patients. All patients were treated within prospective clinical trials and received primary/salvage, high-dose chemotherapy with autologous blood stem cell support for primary poor prognosis disease or recurrent disease. PET results were assessed both visually and by quantifying glucose uptake (standardized uptake values). Results were validated either by histologic examination of a resected mass and/or biopsy (n = 28 lesions) or by a 6-month clinical follow-up after evaluation (n = 57 lesions). RESULTS: F-18 FDG PET showed increased tracer uptake in 32 of 85 residual lesions, with 29 true positive (TP) lesions and three false positive (FP) lesions. Fifty-three lesions were classified by PET as negative (no viable GCT), 33 lesions were classified by PET as true negative (TN), and 20 lesions were classified by PET as false negative (FN). In the blinded reading of the corresponding CT scan and TUM results, 38 residual lesions were assessed correctly as containing viable carcinoma and/or teratoma. Forty-six lesions were classified as non-suspicious by CT scan/TUM (33 TN lesions and 14 falsely classified lesions). PET correctly predicted the presence of viable carcinoma in 5 of these 14 and the absence of viable carcinoma in 3 of these 14 lesions. Resulting sensitivities and specificities for the prediction of residual mass viability were as follows: PET, 59% sensitivity and 92% specificity; radiologic monitoring, 55% sensitivity and 86% specificity; and TUM, 42% sensitivity and 100% specificity. The positive and negative predictive values for PET were 91% and 62%, respectively. The diagnostic efficacy of PET did not improve when patients with teratomatous elements in the primary tumor were excluded from the analysis. In patients with multiple residual masses, a uniformly increased residual F-18 FDG uptake in all lesions was a strong predictor for the presence of viable carcinoma. CONCLUSIONS: F-18 FDG PET imaging performed in conjunction with conventional staging methods offers additional information for the prediction of residual mass histology in patients with nonseminomatous GCT. A positive PET is highly predictive for the presence of viable carcinoma. Other useful indications for a PET examination include patients with multiple residual masses and patients with marker negative disease.

Adult↗

Thymic involvement in Hodgkin disease: CT and sonographic findings.

To evaluate the morphologic characteristics and frequency of thymic enlargement in Hodgkin disease, the initial and follow-up computed tomographic (CT) scans of 43 patients with newly diagnosed Hodgkin lymphoma were retrospectively analyzed. Sonograms of the thymic region in 21 patients were also available and were compared with the CT scans. Initial CT scans showed thymic enlargement in 17 of the 43 patients, no evidence of thymic enlargement in 15 patients, and equivocal findings in 11 patients. Analysis of follow-up CT scans indicated that seven of the 11 patients with initially equivocal findings had had thymic enlargement. In all seven patients, the anterior mediastinal tumor shrank with therapy and adopted a typical tongue-shaped thymic configuration. In nine of the 24 patients with thymic enlargement, the thymus remained enlarged after therapy and full clinical remission. The comparison of sonograms and CT scans showed that sonography could not help differentiate the normal-size thymus from surrounding fatty tissue. All thymic glands that were considered diseased because of enlargement at CT were sonographically visible due to an abnormal, hypoechoic structure. The results of the study show that thymic enlargement presumed to be due to involvement by Hodgkin disease seems to occur more frequently than previously reported.

Adolescent↗

Variability in densitometric assessment of pulmonary emphysema with computed tomography.

OBJECTIVES: The objectives of this study were to investigate whether computed tomography (CT) densitometry can be applied consistently in different centers; and to evaluate the reproducibility of densitometric quantification of emphysema by assessment of different sources of variation, ie, intersite, interscan and inter- and intraobserver variability, in comparison with intersubject variability. MATERIALS AND METHODS: In 5 different hospitals, 119 patients with emphysema were scanned using standardized protocols. In each site, an observer performed a quantitative densitometric analysis (including blood recalibration) on the corresponding patient group (n=23-25) and one observer analyzed the entire group of 119 patients. After several months, the latter observer analyzed all data for a second time. Subsequently, different sources of variation were assessed by variance component analysis with and without volume correction of the data. RESULTS: Inter- and intraobserver variability marginally contributes to the total variability (<0.001%). The interscan variability was 0.02% of the total variation after application of volume correction. The intersite variability was 48% as a result of one deviating CT scanner. Air recalibration normalized deviating air densities in CT scanners. Within sites, the intersubject variability ranged between 93% and 99% based on the analysis of 2 subsequent CT scans of the patients. CONCLUSIONS: Almost all variability in the density measurement of emphysema originates from differences between scanners and from differences in severity of emphysema between patients. Lung densitometry with multislice CT scanners is a highly reproducible measurement, especially if corrected for lung volume, because this reduces interscan variability.

Absorptiometry, Photon↗

The cost-effectiveness of low-dose CT screening for lung cancer: preliminary results of baseline screening.

BACKGROUND: Low-dose CT scan screening greatly improves the likelihood of detecting small nodules and, thus, of detecting lung cancer at a potentially more curable stage. METHODS: To evaluate the cost-effectiveness of a single baseline low-dose CT scan for lung cancer screening in high-risk individuals, data from the Early Lung Cancer Action Project (ELCAP) was incorporated into a decision analysis model comparing low-dose CT scan screening of high-risk individuals (ie, those > or = 60 years with at least 10 pack-years of cigarette smoking and no other malignancies) to observation without screening. Cost-effectiveness was expressed as the incremental cost per year of life saved. The analysis adopted the perspectives of the health-care system. The probability of the different outcomes following the decision either to screen or not to screen an individual at risk was based on data from ELCAP and the Surveillance, Epidemiology, and End Results Registry or published data, respectively. The cost of the screening and treatment of patients with lung cancer was established based on data from the New York Presbyterian Hospital's financial system. The base-case analysis was conducted under the assumption of similar aggressiveness of screen-detected and incidentally discovered lung cancers and then was followed by multiple sensitivity analyses to relax these assumptions. RESULTS: The incremental cost-effectiveness ratio of a single baseline low-dose CT scan was 2,500 US dollars per year of life saved. The base-case analysis showed that screening would be expected to increase survival by 0.1 year at an incremental cost of approximately 230 US dollars. Only when the likelihood of overdiagnosis was > 50% did the cost effectiveness ratio exceed 50,000 US dollars per year of life saved. The cost-effectiveness ratios were also relatively insensitive to estimates of the potential lead-time bias. CONCLUSIONS: A baseline low-dose CT scan for lung cancer screening is potentially highly cost-effective and compares favorably to the cost-effectiveness ratios of other screening programs.

Carcinoma, Non-Small-Cell Lung↗

Central nervous system paracoccidioidomycosis: imaging findings in 17 cases.

PURPOSE: To quantify the imaging findings of 17 patients with central nervous system (CNS) paracoccidioidomycosis. METHOD: Retrospective analysis of the clinical data, films, and laboratory findings of 17 patients with CNS paracoccidioidomycosis. The clinical data were obtained by medical records review. Plain chest films, cranial computed tomography scans (CT), and serum and liquor analysis were evaluated. RESULTS: All the patients were male, with a mean age of 46.5 years. Headache and hemiparesis were the most frequent symptoms. The head CT scans revealed two or more granulomas in 53% of the cases, frequently confined to the parietal lobes (35%) and cerebellar hemispheres (35%). The lesions were hypodense (53%) and irregular (76%) and showed ring-like contrast enhancement (94%). Perilesional edema was seen in 82% of the patients, and hydrocephalus was seen in 41%. CONCLUSION: Although CNS paracoccidioidomycosis might represent a suspicious lesion pattern on CT scan examination, correlation of the CT scan findings, clinical data, plain chest films, and laboratory results is necessary to define the diagnosis of this uncommon entity.

Adolescent↗

Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography.

We evaluated microfocal X-ray-computed tomography (micro-CT) as a method to visualize lung architecture two and three dimensionally and to obtain morphometric data. Inflated porcine lungs were fixed by formaldehyde ventilation. Tissue samples (8-mm diameter, 10-mm height) were stained with osmium tetroxide, and 400 projection images (1,024 x 1,024 pixel) were obtained. Continuous isometric micro-CT scans (voxel size 9 microm) were acquired to reconstruct two- and three-dimensional images. Tissue samples were sectioned (8-microm thickness) for histological analysis. Alveolar surface density and mean linear intercept were assessed by stereology-based morphometry in micro-CT scans and corresponding histological sections. Furthermore, stereology-based morphometry was compared with morphometric semi-automated micro-CT analysis within the same micro-CT scan. Agreement of methods was assessed by regression and Bland-Altman analysis. Comparing histology with micro-CT, alveolar surface densities (35.4 +/- 2.4 vs. 33.4 +/- 1.9/mm, P < 0.05) showed a correlation (r = 0.72; P = 0.018) with an agreement of 2 +/- 1.6/mm; the mean linear intercept (135.7 +/- 14.5 vs. 135.8 +/- 15 microm) correlated well (r = 0.97; P < 0.0001) with an agreement of -0.1 +/- 3.4 microm. Semi-automated micro-CT analysis resulted in smaller alveolar surface densities (33.4 +/- 1.9 vs. 30.5 +/- 1/mm; P < 0.01) with a correlation (r = 0.70; P = 0.023) and agreement of 2.9 +/- 1.4/mm. Non-destructive micro-CT scanning offers the advantage to visualize the spatial tissue architecture of small lung samples two and three dimensionally.

Animals↗

Safety of a single aerosol administration of escalating doses of the cationic lipid GL-67/DOPE/DMPE-PEG5000 formulation to the lungs of normal volunteers.

Several groups are assessing the use of cationic lipids for respiratory gene therapy. To date no human data are available regarding the safety of intra-pulmonary cationic lipid delivery. In preparation for a trial of pulmonary delivery of the CFTR gene, we have assessed the safety of nebulised lipid GL-67/DOPE/DMPE-PEG5000 (GL-67A), the cationic lipid formulation to be used in this study. Fifteen healthy volunteers were given incremental doses of GL-67A via a Pari LC Jet nebuliser; three volunteers in each of five dosing cohorts with a week interval between cohorts. Markers of safety included clinical assessment, measurement of lung function, chest CT scan, serological testing and analysis of induced sputum. Measurements were taken before administration and at intervals up to 21 days thereafter. No adverse clinical events were seen or any statistically significant changes in spirometry or gas transfer. There were no clinically significant changes in any of the blood parameters and no CT changes were seen. Comparisons of the cellular subpopulations (neutrophils, eosinophils, lymphocytes and macrophages) in induced sputum showed no significant alterations following administration of the GL-67A. This study suggests that a single application of aerosol formulation of GL-67A does not result in clinically detectable changes when given by nebulisation into the lungs of normal volunteers and provides an indication of a lipid dose tolerated in man.

Aerosols↗

[Quantitative measurement of ventricular dilatation on CT scan--a proposal of new index and review of literature].

CT scan is able to show cerebral atrophy more safely and more easily than pneumo-encephalography or cerebral angiography. Then, various methods have been reported for quantitative analysis of cerebral atrophy on CT scan. Generally, cerebral atrophy might be judged from the ventricular dilatation with some indices, calculated from various ventricular width. But, there is no general agreement on what index is the most reliable. In this paper, we attempted to establish the index, easy to measure and most reliable. Our method is as follow. Method. We carried out the CT scan (EMI 1010) on 89 neurologically intact patients. Scans were parallel to orbito-meatal line (OML), and were 10 mm in thickness. On CT scan films, various width, area of anterior horns and area of bodies of lateral ventricles were measured (Fig. 1). Measurement about the anterior horns of lateral ventricles were carried out on image the most clearly showed the foramen of Monro. And measurements about the bodies of lateral ventricles were on image, 20 mm above the image of anterior horn. Correlations of various width and areas were calculated (Table 1). Then we proposed new indices with high correlations (over 0.9) with ventricular area; Anterior horn CVI (Cerebro-Ventricular Index) and Body CVI (Fig. 2, 3). Patients with myotonic dystrophy show cerebral atrophy. We carried out the CT scan (GE-CT/T 8800) on 17 myotonic dystrophy patients and 30 controls. Between the two groups, age and sex were almost matched (Fig. 4).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Computed tomographic angiographic imaging of abdominal aortic aneurysms: implications for transfemoral endovascular aneurysm management.

PURPOSE: To describe anatomic features pertinent to patient selection and graft design for transfemoral endovascular aneurysm management (TEAM) of the infrarenal aorta using computed tomographic (CT) angiography. METHODS: A prospective noncomparative analysis of 102 spiral CT scans of the abdominal aorta of patients with abdominal aortic aneurysms was performed. From the original CT data set, slices were reconstructed perpendicular to the vessel axis (central lumen line) at a 10 mm interval. In these reconstructed slices, diameter measurements were performed. Vessel length was measured along the central lumen line. In each patient possibilities for TEAM were analyzed. RESULTS: Because of technical reasons, 36 scans were excluded from the analysis. Of the remaining 66 patients, 18 could potentially be treated with a bifurcated endovascular device. The infrarenal aortic diameter-to-iliac artery diameter ratio was less than 2 in most patients. The vessel segments judged to be adequate for endovascular graft anchoring had a noncylindrical shape in the majority of cases. CONCLUSION: Only a minority of patients with abdominal aortic aneurysms can at this stage be treated with an endovascular graft. The ideal endovascular graft should be a combination of rigid and flexible components. The proximal and distal attachment systems should have some flexibility with an intrinsic maximum diameter while the midsection of the graft can be relatively rigid.

Adult↗

Neuropsychological-neurophysiological alterations and brain atrophy in cirrhotic patients.

Psychometric performance has been reported to be related to brain atrophy in cirrhotics, but the relationship between brain atrophy and EEG findings is still unknown. The aim of this study was to ascertain the relationship among brain atrophy, EEG, and cognitive performance in cirrhotics. Sixty-eight cirrhotics (age = 55 +/- 10 years; males-66%) underwent psychometric evaluation (Symbol Digit Test, Trail Making Test-Part A, Scan test), EEG recording and spectral analysis (S-EEG), and brain CT scan. Central brain atrophy was ascertained by the following indexes of brain atrophy: the Evans' index, the bicaudate index, the cella media index, the bifrontal index, and the ventricular index; cortical brain atrophy by the sulci index. The severity of liver failure was assessed by the Child-Pugh score: 18% of patients were Child-Pugh Class A, 50% Class B, and 32% Class C. Central and cortical atrophies were found to be correlated with age, but not with the Child-Pugh score. Psychometric performance and the EEG mean dominant frequency (MDF) were found to be correlated with brain atrophy. Multivariate analysis showed that a poor psychometric performance was independently predicted by EEG slowing (MDF: p < 0.01) and by central brain atrophy (cella media index: p < 0.01). In conclusion, brain atrophy was associated with a poor psychometric performance and EEG alterations in cirrhosis. Both brain atrophy and EEG alterations independently predicted cognitive dysfunction in cirrhotic patients.

Adult↗

Suspected spinal cord compression in breast cancer patients: a multidisciplinary risk assessment.

Breast cancer is the most common cause of metastatic epidural spinal cord compression (SCC) in women, and this condition results in significant neurologic dysfunction and morbidity. Prior studies of patients with suspected SCC did not employ multivariate analysis techniques, often included persons with a wide variety of malignancies, and generally focused on identifying associated neurologic and radiologic features. We therefore conducted a study examining a more comprehensive set of potential clinical risk factors in breast cancer patients with suspected SCC. We retrospectively analysed 123 episodes of suspected SCC among 93 breast cancer patients evaluated by spine computed tomography (CT) scanning. Multiple logistic regression analysis was employed to identify independent predictors of SCC. Clinically significant metastatic epidural cancer was defined as thecal sac compression (TSC), which occurred in 33 episodes (27%). Four independent predictors of TSC were identified and included oncologic features (known bone metastases > or = 2 years, metastatic disease at initial diagnosis) in addition to neurologic and radiologic features (objective weakness, vertebral compression fracture on spine radiograph). These four predictors stratified episodes into subgroups with widely varying risks of TSC, ranging from 12% (0 risk factors) to 85% (> or = 3 risk factors). These results suggest that the evaluation of breast cancer patients with suspected SCC should include clinical information about their disease course in addition to neurologic examination and prior imaging studies. If confirmed, these predictors may help clinicians assess risk in this patient population.

Adult↗

A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data.

We developed a highly automated three-dimensionally based method for the segmentation of bone in volumetric computed tomography (CT) datasets. The multistep approach starts with three-dimensional (3-D) region-growing using local adaptive thresholds followed by procedures to correct for remaining boundary discontinuities and a subsequent anatomically oriented boundary adjustment using local values of cortical bone density. We describe the details of our approach and show applications in the proximal femur, the knee, and the skull. The accuracy of the determination of geometrical parameters was analyzed using CT scans of the semi-anthropomorphic European spine phantom. Depending on the settings of the segmentation parameters cortical thickness could be determined with an accuracy corresponding to the side length of 1 to 2.5 voxels. The impact of noise on the segmentation was investigated by artificially adding noise to the CT data. An increase in noise by factors of two and five changed cortical thickness corresponding to the side length of one voxel. Intraoperator and interoperator precision was analyzed by repeated analysis of nine pelvic CT scans. Precision errors were smaller than 1% for trabecular and total volumes and smaller than 2% for cortical thickness. Intraoperator and interoperator precision errors were not significantly different. Our segmentation approach shows: 1) high accuracy and precision and is 2) robust to noise, 3) insensitive to user-defined thresholds, 4) highly automated and fast, and 5) easy to initialize.

Algorithms↗