Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “insertion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Prospective examination of epidural catheter insertion.

BACKGROUND: Although it is generally accepted that inserting epidural catheters 3-4 cm into the epidural space minimizes complications, no prospective randomized examination of epidural catheter insertion length has been published. METHODS: Eight hundred healthy parturients requesting epidural analgesia were randomized to have open-tip epidural catheters inserted 2, 4, 6, or 8 cm within the epidural space. The incidences of intravenous cannulation, unilateral sensory analgesia, and subsequent catheter dislodgment were recorded. Catheter insertions that resulted in intravenous cannulation or unilateral analgesia were incrementally withdrawn and retested with additional local anesthetic to determine the effectiveness of epidural catheter manipulation. RESULTS: Epidural catheters inserted 8 cm within the epidural space were more likely to result in intravenous cannulation. Epidural catheters inserted 2 cm within the epidural space were less likely to result in unilateral sensory analgesia but were more likely to become dislodged. Twenty-three percent of epidural catheters inserted > 2 cm within the epidural space required manipulation. Epidural catheters inserted 2 or 4 cm required replacement more often than epidural catheters inserted 6 or 8 cm. Ninety-one percent and 50% of epidural catheters that resulted in unilateral sensory analgesia and intravenous cannulation, respectively, provided analgesia for labor and delivery after incremental withdrawal. CONCLUSIONS: Epidural catheters should be inserted either 2 cm when rapid labor is anticipated or 6 cm when prolonged labor or cesarean delivery is likely. Additionally, epidural catheters that result in intravenous cannulation or unilateral sensory analgesia can be manipulated effectively to provide analgesia for labor and delivery.

Adult↗

A prospective, randomized study of intramedullary nails inserted with and without reaming for the treatment of open and closed fractures of the tibial shaft.

OBJECTIVES: To determine if there are differences in healing, complications, or number of procedures required to obtain union among open and closed tibia fractures treated with intramedullary (IM) nails inserted with and without reaming. DESIGN: Prospective, surgeon-randomized comparative study. SETTING: Level One trauma center. PATIENTS: Ninety-four consecutive patients with unstable closed and open (excluding Gustilo Grade IIIB and IIIC) fractures of the tibial shaft treated with IM nail insertion between November 1, 1994, and June 30, 1997. INTERVENTION: Interlocked IM nail insertion with and without medullary canal reaming. MAIN OUTCOME MEASURES: Time to union, type and incidence of complications, and number of secondary procedures performed to obtain union. RESULTS: For open fractures, there were no significant differences in the time to union or number of additional procedures performed to obtain union in patients with reamed nail insertion compared with those without reamed insertion. A higher percentage of closed fractures were healed at four months after reamed nail insertion compared with unreamed insertion (p = 0.040), but there was not a difference at six and twelve months. More secondary procedures were needed to obtain union after unreamed nail insertion for the treatment of closed tibia fractures, but the difference was not statistically significant given the limited power of our study (p = 0.155). Broken screws were seen only in patients treated with smaller-diameter nails inserted without reaming, and the majority occurred in patients who were noncompliant with weight-bearing restrictions. There were no differences in rates of infection or compartment syndrome. CONCLUSION: Our findings support the use of reamed insertion of IM nails for the treatment of closed tibia fractures, which led to earlier time to union without increased complications. In addition, canal reaming did not increase the risk of complications in open tibia fractures.

Adolescent↗

Effect of shoe insert construction on foot and leg movement.

PURPOSE: The purpose of this study was to quantify changes in foot eversion and tibial rotation during running resulting from systematic changes of material composition of five shoe inserts of the same shape. METHODS: Tests were performed with 12 subjects. The inserts had a bilayer design using two different materials at the top and bottom of the insert. The functional kinematic variables examined in this study were the foot-leg in-eversion angle, beta, and the leg-foot tibial rotation, rho. Additionally, the subject characteristics of arch height, relative arch deformation, and active range of motion were quantified. The statistical analysis used was a two way repeated measures MANOVA (within trials and inserts). RESULTS: The average group changes resulting from the studied inserts in total shoe eversion, total foot eversion, and total internal tibial rotation were typically smaller than 1 degree when compared with the no-insert condition and were statistically not significant. The measured ranges of total foot eversion for all subjects were smallest for the softest and about twice as large for the hardest insert construction. Thus, the soft insert construction was more restrictive, forcing all feet into a similar movement pattern, whereas the harder combinations allowed for more individual variation of foot and leg movement and did not force the foot into a preset movement pattern. The individual results showed substantial differences between subjects and a trend: Subjects who generally showed a reduction of tibial rotation with all tested inserts typically had a flexible foot. However, subjects who generally showed an increase of tibial rotation typically had a stiff foot. CONCLUSIONS: The results of this study suggest that subject specific factors such as static, dynamic, and neuro-physiological characteristics of foot and leg are important to match specific feet and shoe inserts optimally.

Adult↗

Relationship between footwear comfort of shoe inserts and anthropometric and sensory factors.

PURPOSE: The purposes of this study were (a) to determine lower extremity anthropometric and sensory factors that are related to differences in comfort perception of shoe inserts with varying shape and material and (b) to investigate whether shoe inserts that improve comfort decrease injury frequency in a military population. METHODS: 206 military personnel volunteered for this study. The shoe inserts varied in arch and heel cup shape, hardness, and elasticity in the heel and forefoot regions. A no insert condition was included as the control condition. Measured subject characteristics included foot shape, foot and leg alignment, and tactile and vibration sensitivity of the plantar surface of the foot. Footwear comfort was assessed using a visual analog scale. Injury frequency was evaluated with a questionnaire. The statistical analyses included Student's t-tests for repeated measures, ANOVA (within subjects), MANOVA (within insert combinations), and chi-square tests. RESULTS: The average comfort ratings for all shoe inserts were significantly higher than the average comfort rating for the control condition. The incidence of stress fractures and pain at different locations was reduced by 1.5-13.4% for the insert compared with the control group. Foot arch height, foot and leg alignment, and foot sensitivity were significantly related to differences in comfort ratings for the hard/soft, the viscous/elastic, and the high arch/low arch insert combinations. CONCLUSIONS: Shoe inserts of different shape and material that are comfortable are able to decrease injury frequency. The results of this study showed that subject specific characteristics influence comfort perception of shoe inserts.

Adult↗

The safety and efficacy of direct trocar insertion with elevation of the rectus sheath instead of the skin for pneumoperitoneum.

Abdominal access in endoscopic surgery carries a finite risk of visceral injury. Bleeding, subcutaneous emphysema, gastrointestinal tract perforation, minor and major vascular injury, and intraperitoneal adhesions are the potential complications associated with abdominal access and creation of pneumoperitoneum. There are 4 basic techniques used to create pneumoperitoneum: blind Veress needle, direct trocar insertion, optical trocar insertion, and open laparoscopy. Veress needle and direct trocar insertion are blind techniques, and their use can result in severe visceral and vascular injuries. To prevent visceral and vascular injuries caused by the technique used for the creation of pneumoperitoneum, laparoscopic surgeons and gynecologists look for safe and effective laparoscopic access techniques. Direct trocar insertion without previous pneumoperitoneum was reported to be a safe alternative to Veress needle insertion. We carried out this study to compare the ease of use, safety, and efficacy of direct trocar insertion with elevation of the rectus sheath and blind insertion of the Veress needle in laparoscopic surgery. In 578 laparoscopic procedures, the patients were assigned to one of the following groups: blind insertion of the Veress needle (group 1, n = 301) and direct trocar insertion with elevation of the rectus sheath using 2 towel clips (group 2, n = 277). Total complication rates were 15.7% (n = 33) and 3.3% (n = 4) in groups 1 and 2, respectively (P < 0.05). Direct trocar insertion with elevation of the rectus sheath using 2 towel clips is an easy, safe, and effective technique.

Digestive System Diseases↗

A literature search on pharmacokinetic drug interactions of statins and analysis of how such interactions are reflected in package inserts in Japan.

BACKGROUND AND OBJECTIVES: Statins (HMG-CoA reductase inhibitors) are one of the most widely prescribed classes of drugs throughout the world, because of their excellent cholesterol-lowering effect and overall safety profile except for rare but fatal rhabdomyolysis arising either directly or indirectly by pharmacokinetic interactions with certain other drugs. As package inserts in pharmaceuticals are the primary source of information for health care providers, we carried out a literature search to examine how crucial information was provided in package inserts of five statins approved in Japan (simvastatin, atorvastatin, fluvastatin, pravastatin and pitavastatin). METHODS: A MEDLINE search from 1996 to June 2004 was carried out to identify studies on clinical pharmacokinetic drug interactions for the five statins. We mainly collected information on area under plasma concentration (AUC) following co-administration of statins with other drugs. The current package inserts used in Japan were obtained from the website of the Pharmaceutical and Medical Device Agency whereas USA package inserts were obtained from the Food and Drug Administration website. RESULTS: The majority of package inserts listed the drugs that interacted with statins with most describing the risk of rhabdomyolysis because of the possibility of increases in blood concentration. However, quantitative information such as change in AUC was provided in only a few cases. Instructions for dosage adjustment are seldom provided in the Japanese package inserts. USA package inserts list almost identical drug interactions as the Japanese package inserts, although they contain more quantitative data, especially for typical cytochrome P450 (CYP) inhibitors. CONCLUSION: All pharmacokinetic drug interactions including relevant quantitative data for potential effectors and details on mechanisms of interaction need to be given in package inserts as soon as the information becomes available, to ensure safe and proper use of the drugs concerned. Including such information in the package insert will be an extremely valuable aid for health care providers.

Area Under Curve↗

Birthweight in liveborn twins: the influence of the umbilical cord insertion and fusion of placentas.

OBJECTIVE: To assess the relation of umbilical cord insertion and fusion of placentas with birthweight in monozygotic monochorionic, monozygotic dichorionic, and dizygotic twins. DESIGN: A prospective population study. POPULATION: 4529 liveborn twin pairs whose birthweight was recorded, placentas were examined, and site of umbilical cord insertion was determined after delivery. RESULTS: Infants with a peripheral cord insertion weighed 150g less (P < 0.001) than infants with a central cord insertion. Dizygotic infants had a significantly (P < 0.001) higher incidence of central cord insertion (82%) than monozygotic dichorionic (65%) and monozygotic monochorionic (53%) infants. Monozygotic dichorionic infants with fused placentas and a peripheral cord insertion weighed on average 300g less (P < 0.01) than infants with separate placentas and a central cord insertion. In dizygotic infants, fusion of the placentas did not affect birthweight. CONCLUSIONS: Umbilical cord insertion is associated with birthweight in all types of twins. Fusion of the placentas only affects the birthweight of monozygotic dichorionic, not that of dizygotic infants. This might be due to the greater proximity of implantation of monozygotic dichorionic twins. Dizygotic twins weighed more than monozygotic twins only when placentas were fused and cord insertion was peripheral. Hence, the difference between the mean birthweights of dizygotic, monozygotic dichorionic, and monozygotic monochorionic infants may originate from the least favourable antenatal situation, namely fused placentas with a peripheral cord insertion, which occurs most frequently in monozygotic twins.

Analysis of Variance↗

Insertion of an intrauterine contraceptive device after induced or spontaneous abortion: a review of the evidence.

OBJECTIVE: Assess the safety and efficacy of intrauterine contraceptive device (IUCD) insertion immediately after induced or spontaneous abortion. DESIGN: Systematic search for randomised trials that had at least one treatment arm that involved IUCD insertion immediately after an induced or spontaneous miscarriage using Medline, Popline, EMBASE, and review articles supplemented by correspondence with investigators. POPULATION: Women of any age or gravidity who had an IUCD inserted immediately after evacuation for spontaneous or induced abortion. METHODS: Articles were abstracted and the raw data from tables were analysed with RevMan 3.1 software. We focused on Tietze-Potter gross life table probabilities with denominators of person-time of exposure. MAIN OUTCOME MEASURES: Rates of perforation, expulsion, pelvic inflammatory disease, contraceptive failure, and method continuation. RESULTS: Complication rates for immediate post-abortal IUCD insertion were low. Perforation was rare with a rate of approximately one per 1,000 insertions. One year gross cumulative expulsion rates ranged from 1.8% to 12.6%, pregnancy rates from 0.6% to 2.1%, and continuation rates from 54% to 90%. The net discontinuation rate due to pelvic inflammatory disease was low, ranging from 0.0 to 0.8 per 100 women at one year. Increasing gestational age at insertion was associated with increased expulsion rates. CONCLUSIONS: Post-abortal IUCD insertion is safe and effective. The risks of perforation, expulsion, pelvic inflammatory disease and contraceptive failure were low and similar to those reported for interval insertion. Second trimester gestational age is associated with an increased risk of expulsion. Immediate insertion may have a higher expulsion rate than delayed insertion. However, these risks may be outweighed by the benefit of immediate contraception.

Abortion, Induced↗

Does hard insertion and space improve shock absorption ability of mouthguard?

Mouthguards are expected to reduce sports-related orofacial injuries. Numerous studies have been conduced to improve the shock absorption ability of mouthguards using air cells, sorbothane, metal wire, or hard material insertion. Most of these were shown to be effective; however, the result of each study has not been applied to clinical use. The aim of this study was to develop mouthguards that have sufficient prevention ability and ease of clinical application with focus on a hard insertion and space. Ethylene vinyl acetate (EVA) mouthguard blank used was Drufosoft and the acrylic resin was Biolon (Dreve-Dentamid GMBH, Unna, Germany). Three types of mouthguard samples tested were constructed by means of a Dreve Drufomat (Type SO, Dreve-Dentamid) air pressure machine: the first was a conventional laminated type of EVA mouthguard material; the second was a three layer type with acrylic resin inner layer (hard-insertion); the third was the same as the second but with space that does not come into contact with tooth surfaces (hard + space). As a control, without any mouthguard condition (NOMG) was measured. A pendulum type impact testing machine with interchangeable impact object (steel ball and baseball) and dental study model (D17FE-NC.7PS, Nissin, Tokyo, Japan) with the strain gages (KFG-1-120-D171-11N30C2: Kyowa, Tokyo, Japan) applied to teeth and the accelerometer to the dentition (AS-A YG-2768 100G, Kyowa) were used to measure transmitted forces. Statistical analysis (anova, P < 0.01) showed significant differences among four conditions of NOMG and three different mouthguards in both objects and sensor. About acceleration: in a steel ball which was a harder impact object, shock absorption ability of about 40% was shown with conventional EVA and hard-insertion and about 50% with hard + space. In a baseball that was softer compared with steel ball, a decrease rate is smaller, reduction (EVA = approximately 4%, hard-insertion = approximately 12%, hard + space = approximately 25%) was admitted in the similar order. A significant difference was found with all the combinations except for between EVA and hard-insertion with steel ball (Tukey test). About distortion: both buccal and lingual, distortions had become small in order of EVA, hard-insertion, and hard + space, too. The decrease rate is larger than acceleration, EVA = approximately 47%, hard-insertion = 80% or more, and hard +space = approximately 98%, in steel ball. EVA = approximately 30%, hard-insertion = approximately 75%, and hard + space = approximately 98% in baseball. And a significant difference was found with all the combinations (Tukey test). Especially, hard + space has decreased the distortion of teeth up to several percentages. Acceleration of the maxilla and distortions of the tooth became significantly smaller when wearing any type of mouthguard, in both impact objects. But the effect of mouthguard was clearer in the distortion of the tooth and with steel ball. Considering the differences of mouthguards, the hard-insertion and the hard + space had significantly greater buffer capacity than conventional EVA. Furthermore, hard + space shows quite high shock absorption ability in the tooth distortion. Namely, hard + space has decreased the distortion of teeth up to several percentages in both impact objects.

Acceleration↗

The effect of timing of administration of oestradiol benzoate on characteristics of oestrus, timing of ovulation and fertility in Bos indicus heifers synchronised with a progesterone releasing intravaginal insert.

OBJECTIVE: To compare the timing of onset of oestrus and ovulation, characteristics of oestrus, and fertility in Bos indicus heifers synchronised with a progesterone releasing intravaginal insert (IVP4) and administration of oestradiol benzoate (ODB) either at the time of removal of the insert or 24 h later. DESIGN: Cohort study. PROCEDURE: Bos indicus and Bos indicus cross heifers were treated on two farms (Farm A, n = 273; Farm B, n = 47) with an IVP4 for 8 days with 1.0 mg of ODB administered at the time of device insertion and 250 mg of cloprostenol at the time of device removal. Heifers in the ODB-0 group were administered 0.75 mg of ODB at the time of device removal while heifers in the ODB-24 group were administered the same dose of ODB 24 h after device removal. Heifers were inseminated once daily after detection of oestrus. Heifers not detected in oestrus by 72 h after removal of inserts were inseminated at that time. Oestrus was detected in heifers on Farm A using heatmount detectors while on Farm B oestrus in heifers was monitored using radiotelemetry of mounting pressure. Ovarian follicular development was monitored daily in 30 heifers on Farm B from the time of administration of inserts until ovulation to a maximum of 96 h after removal of inserts, and again 11 days after removal of inserts (Day 19). A blood sample was collected from all heifers on Farm B on Day 19 and analysed for plasma concentration of progesterone. Pregnancy was diagnosed 6 to 8 weeks after insemination. RESULTS: Administration of ODB at the time of removal of inserts shortened the time interval to oestrus and ovulation (P < 0.001), increased the number of mounts recorded during oestrus (P = 0.04) and reduced the odds of pregnancy (P = 0.03). The proportion of heifers ovulating on Farm B was 67% and was not affected by treatment group (P = 0.61). The mean diameter of the largest follicle measured in ovaries was greater at the time of removal of inserts (9.1 +/- 0.6 vs 10.7 +/- 0.4; P = 0.03) and at the expected time of the LH surge (8.1 +/- 0.4 vs 11.5 +/- 0.3 mm; P < 0.001) in heifers that ovulated compared to heifers that failed to ovulate, respectively. Emergence of a new follicular wave was not detected during the synchronisation treatment in heifers that failed to ovulate. Concentrations of progesterone in plasma on Day 19 were less in non-pregnant heifers (P = 0.05) compared to heifers subsequently diagnosed as pregnant to insemination and were affected by the diameter of the ovulatory follicle (P = 0.01). CONCLUSION: Administration of ODB at the time of removal of inserts can shorten the time interval to oestrus and ovulation and can reduce fertility when insemination is carried out once daily. Further work is needed to determine if prolonged suppression of follicular development, anovulatory oestrus and premature ovulation occuring in some heifers is associated with administration of ODB.

Administration, Intravaginal↗

Frictional insertion kinetics of bone biopsy needles.

Patients undergoing a percutaneous bone biopsy often complain of pain during needle insertion, despite local anesthesia. Bone biopsy needles are typically inserted with combined axial and twisting motions. These motions could cause pain through frictional heating or direct mechanical irritation. The hypothesis of this study is that the insertion energy of bone biopsy needles can be reduced by modifying the insertion kinetics or by adding a friction-lowering coating to the needles. Jamshidi bone biopsy needles were driven into a bone analog model by an MTS materials testing machine operating under axial and rotational displacement control. The load/torque recordings showed that, to significantly decrease insertion energy and peak resistance to needle insertion, axial velocity and angular frequency had to be decreased to one quarter of the baseline, typical-usage parameters. However the increased insertion time may not be acceptable clinically. The majority of the insertion energy was associated with the needle axial thrust rather than with needle twisting. Overcoming friction against the side of the needle consumed much more of the insertion energy than did the process of cutting per se. None of five needle coatings tested succeeded in appreciably lowering the insertion energy, and none achieved a substantial decrease in peak resisting force.

Biopsy, Needle↗

Identification, distribution, and sequence analysis of new insertion elements in Caulobacter crescentus.

We describe two insertion elements isolated from Caulobacter crescentus that are designated IS298 and IS511. These insertion elements were cloned from spontaneous flagellar (fla) gene mutants SC298 and SC511 derived from the wild-type strain CB15 (ATCC 19089), in which they were originally identified as insertions in the flbG operon of the hook gene cluster (N. Ohta, E. Swanson, B. Ely, and A. Newton, J. Bacteriol. 158:897-904, 1984). IS298 and IS511 were each present in C. crescentus CB2 and CB15 in at least four different positions, but neither was present in strain CB13 or in several Caulobacter species examined, including C. vibrioides, C. leidyia, and C. henricii. Nucleotide sequence analysis across the chromosome-insertion element junctions showed that IS298 is located 152 base pairs (bp) upstream from the ATG translation start of the hook protein gene flaK, where it is bounded by a 4-bp direct repeat derived from the site of insertion, and that IS511 is inserted at codon 186 of the flaK coding sequence, where it is also bounded by a 4-bp direct repeat duplicated from the site of insertion. The ilvB102 mutation in strain SC125 was also shown to result from insertion sequence IS511, but no duplication of the genomic sequence was present at the insertion element junctions. IS298 contains an imperfect terminal inverted repeat 16 bp long, and IS511 contains a 32-bp inverted repeat at the termini. IS298 and IS511 are the first insertion elements described in C. crescentus.

Bacteria↗

Insertion mutagenesis of the gene encoding the ferrichrome-iron receptor of Escherichia coli K-12.

The ferrichrome-iron receptor of Escherichia coli K-12 encoded by the fhuA gene is a multifunctional outer membrane receptor with an Mr of 78,000. It is required for the binding and uptake of ferrichrome and is the receptor for bacteriophages T5, T1, phi 80, and UC-1 as well as for colicin M. The fhuA gene was cloned into pBR322, and the recombinant plasmid pGC01 was mutagenized by the insertion of 6-base-pair TAB (two amino acid Barany) linkers into CfoI and HpaII restriction sites distributed throughout the coding region. A library of 18 TAB linker insertions in fhuA was generated; 8 of the mutations were at CfoI sites and 10 were at HpaII sites. All mutations inserted a hexamer that encoded a unique SacI site. A large deletion in fhuA was also isolated by TAB linker mutagenesis. Except for the deletion mutant, all of the linker insertion mutant FhuA proteins were found in the outer membrane in amounts similar to those found in the wild type. Five of the linker insertion mutants were susceptible to cleavage by endogenous proteolytic activity: a second FhuA-related band that migrated at approximately 72 kilodaltons could be detected on Coomassie blue-stained gels and on Western blots (immunoblots) by using a carboxy terminus-specific anti-peptide antibody. Receptor functions were measured with the mutated genes present in a single copy on the chromosome. Some of the receptors conferred wild-type phenotypes: they demonstrated growth promotion by ferrichrome and the same efficiency of plating as that of wild-type FhuA; killing by colicin M was also unaffected. Several mutants were altered in their sensitivities to the lethal agents. TAB linker insertions after amino acids 69 and 128 abolished all receptor functions. Phage T5 id not bind to these mutant FhuA proteins in detergent extracts. The deletion mutant was also defective in all FhuA functions. Sensitivity to the lethal agents of cellsl that expressed mutant FhuAs with insertions after amino acids 59 and 135 was reduced by several orders of magnitude. Insertion at other selected sites decreased some or all receptor functions only slightly. An insertion after amino acid 321 selectively eliminated ferrichrome growth promotion. Finally, a strain carrying a mutant fhuA gene on the chromosome in which the linker insertion occurred after amino acid 82 showed a tonB phenotype. These subtle perturbations that were introduced into the FhuA protein resulted in changes in its stability and in the binding and uptake of its cognate ligands.

Amino Acid Sequence↗

Insertion of the human immunodeficiency virus CD4 receptor into the envelope of vesicular stomatitis virus particles.

Enveloped virus particles carrying the human immunodeficiency virus (HIV) CD4 receptor may potentially be employed in a targeted antiviral approach. The mechanisms for efficient insertion and the requirements for the functionality of foreign glycoproteins within viral envelopes, however, have not been elucidated. Conditions for efficient insertion of foreign glycoproteins into the vesicular stomatitis virus (VSV) envelope were first established by inserting the wild-type envelope glycoprotein (G) of VSV expressed by a vaccinia virus recombinant. To determine whether the transmembrane and cytoplasmic portions of the VSV G protein were required for insertion of the HIV receptor, a chimeric CD4/G glycoprotein gene was constructed and a vaccinia virus recombinant which expresses the fused CD4/G gene was isolated. The chimeric CD4/G protein was functional as shown in a syncytium-forming assay in HeLa cells as demonstrated by coexpression with a vaccinia virus recombinant expressing the HIV envelope protein. The CD4/G protein was efficiently inserted into the envelope of VSV, and the virus particles retained their infectivity even after specific immunoprecipitation experiments with monoclonal anti-CD4 antibodies. Expression of the normal CD4 protein also led to insertion of the receptor into the envelope of VSV particles. The efficiency of CD4 insertion was similar to that of CD4/G, with approximately 60 molecules of CD4/G or CD4 per virus particle compared with 1,200 molecules of VSV G protein. Considering that (i) the amount of VSV G protein in the cell extract was fivefold higher than for either CD4 or CD4/G and (ii) VSV G protein is inserted as a trimer (CD4 is a monomer), the insertion of VSV G protein was not significantly preferred over CD4 or CD4/G, if at all. We conclude that the efficiency of CD4 or CD4/G insertion appears dependent on the concentration of the glycoprotein rather than on specific selection of these glycoproteins during viral assembly.

Base Sequence↗

Long-range effects of retroviral insertion on c-myb: overexpression may be obscured by silencing during tumor growth in vitro.

The c-myb oncogene is a frequent target for retroviral activation in hemopoietic tumors of avian and mammalian species. While insertions can target the gene directly, numerous clusters of retroviral insertion sites have been identified which map close to c-myb and outside the transcription unit in T-lymphomas (Ahi-1, fit-1, and Mis-2) and monocytic and myeloid leukemias (Mml1, Mml2, Mml3, and Epi-1). Previous analyses showed no consistent effect of these insertions on c-myb expression, raising the possibility that other nearby genes were the true targets. In contrast, our analysis of four cell lines established from lymphomas bearing insertions at fit-1 (fti-1) (feline leukemia virus) and Ahi-1 (Moloney murine leukemia virus) shows that these display higher expression levels of c-myb RNA and protein compared to a panel of phenotypically similar cell lines lacking such insertions. An interesting feature of the cell lines with long-range c-myb insertions was that each also carried an activated Myc allele. The potential for oncogenic synergy between Myb and Myc in T-cell lymphoma was confirmed in transgenic mice overexpressing alleles of both genes in the T-cell compartment, lending further credence to the case for c-myb as the major target for long-range activation. In contrast, mapping and analysis of c-myb neighboring genes (HBS1 and FLJ20069) showed that the expression of these genes did not correlate well with the presence of proviral insertions. A possible explanation for the paradoxical behavior of c-myb was provided by one of the murine T-lymphoma lines bearing an insertion at Ahi-1 (p/m16i) that reproducibly down-regulated c-myb RNA and protein to very low levels or undetectable levels on prolonged culture. Our observations implicate c-myb as a key target of upstream and downstream retroviral insertions. However, overexpression may become dispensable during outgrowth in vitro, and perhaps during tumor progression in vivo, providing a potential rationale for the previously observed discordance between retroviral insertion and c-myb expression levels.

Animals↗

Anatomical study of the femoral and tibial insertions of the anteromedial and posterolateral bundles of human anterior cruciate ligament.

BACKGROUND: Recently, anatomical anterior cruciate ligament reconstruction with 2-bundle reconstruction has been proposed. Few previous publications have mentioned anatomical measurements of the insertions of these bundles. PURPOSE: To determine the precise anatomical measurements of the femoral and tibial insertions for anteromedial and posterolateral bundles of anterior cruciate ligament grafts. STUDY DESIGN: Descriptive laboratory study. METHODS: Thirty-two femurs and 31 tibias were selected. The anterior cruciate ligament was divided into anteromedial and posterolateral bundles to the insertion footprint. Six measurements of the femoral insertion and 4 measurements of the tibial insertion were examined. Locations of the femoral insertions were examined using lateral radiographs of the femur. RESULTS: The distance between the center of the femoral insertions of the anteromedial and posterolateral bundles and the posterior margin of the lateral femoral condyle averaged 7.6 and 7.0 mm, respectively. The distance between the center of the femoral insertions of the anteromedial and posterolateral bundles to the intercondylar roof averaged 4.1 and 11.3 mm, respectively. The sagittal distance between the center of the tibial insertions of the anteromedial and posterolateral bundles from the anterior margin of the tibial articular cartilage averaged 13.0 and 14.7 mm, respectively. The distance from the lateral margin of the articular cartilage of the tibial plateau to the center of the tibial insertions of the anteromedial and posterolateral bundles averaged 44.2% and 52.4% of the total widest width of the tibial plateau, respectively. On the lateral radiograph of femoral condyles, the center of the anteromedial bundle was located at 31.9% from the posterior margin of the femoral condyle and 26.9% from the roof, and that of the posterolateral bundle was located at 39.8% from the posterior margin of the femoral condyle and 53.2% from the roof. CLINICAL RELEVANCE: It is important to know the precise anatomy of anterior cruciate ligament bundles when performing reconstruction and to evaluate anterior cruciate ligament reconstruction surgery on an anatomical basis.

Anterior Cruciate Ligament↗

[The development and operation of a package inserts service system for electronic medical records].

To promote the appropriate use of pharmaceuticals and to prevent side effects, physicians need package inserts on medicinal drugs as soon as possible. A medicinal drug information service system was established for electronic medical records to speed up and increase the efficiency of package insert communications within a medical institution. Development of this system facilitates access to package inserts by, for example, physicians. The time required to maintain files of package inserts was shortened, and the efficiency of the drug information service increased. As a source of package inserts for this system, package inserts using a standard generalized markup language (SGML) form were used, which are accessible to the public on the homepage of the Organization for Pharmaceutical Safety and Research (OPSR). This study found that a delay occurred in communicating revised package inserts from pharmaceutical companies to the OPSR. Therefore a pharmaceutical department page was set up as part of the homepage of the medical institution for electronic medical records to shorten the delay in the revision of package inserts posted on the medicinal drug information service homepage of the OPSR. The usefulness of this package insert service system for electronic medical records is clear. For more effective use of this system based on the OPSR homepage pharmaceutical companies have been requested to provide quicker updating of package inserts.

Clinical Pharmacy Information Systems↗

Effect of shoe inserts on kinematics, center of pressure, and leg joint moments during running.

PURPOSE: The purposes of this project were to assess the effect of four different shoe inserts on the path of the center of pressure (COP), to quantify the effect of these inserts on selected knee joint moments during running, and to assess the potential of COP data to predict the effects of inserts/orthotics on knee joint moments. METHODS: Kinematics for the lower extremities, resultant ankle and knee joint moments, and the path of the COP were collected from the right foot of 15 male subjects while running heel-toe with five different shoe inserts (full or half with 4.5-mm postings). RESULTS: Individual movement changes with respect to the neutral insert condition were typically small and not systematic. Significant changes for the path of the COP were registered only for the full lateral insert condition with an average shift toward the lateral side. The mediolateral shift of the COP was not consistent for the full medial and the two half-shoe inserts. The subject-specific reactions to the inserts' intervention in the corresponding knee joint moments were typically not consistent. Compared with the neutral insert condition, subjects showed increases or decreases of the knee joint moments. The correlation between the individual COP shifts and the resultant knee joint moment was generally small. CONCLUSION: The results of this study showed that subject-specific reactions to the tested inserts were often not as expected. Additionally, reactions were not consistent between the subjects. This result suggests that the prescription of inserts and/or orthotics is a difficult task and that methods must be developed to test and assess these effects. Such methods, however, are not currently available.

Adult↗