Force transducer for measurement of muscle contraction.

Single channel force transducers, intended for measurement and evaluation curves of preconditioned fibres in muscles contracting synergistically during direct or indirect electric stimulation of isolated muscle, were designed, developed and experimentally tested. The force transducers were made up of a full Wheatstone bridge composed of four semiconductor strain gauges bonded on a specially designed cantilever. The transducers with a natural frequency 350 Hz and compliance of 0.25 micron g-1 represents a very linear dependence of the output voltage upon the load giving a sensitivity for the transducers of 0.5 mV mN-1 with a bridge excitation voltage of 5 V. The nominal range of each transducer is 0-70 mN. The system is able to record even a contraction of only a few muscle fibres, both single twitches as well as sustained tonic contractions.

Animals↗

ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.

Intracranial pressure (ICP) monitoring has become the mainstay of multimodal neuromonitoring of comatous patients after head injury. In the presence of rising ICP and faced with pressures, difficult to control, aggressive measures, such as hypothermia may be used. The ICP readings should not be influenced by temperature changes. A laboratory test was designed to simulate temperature variations between 20 degrees C and 45 degrees C at different pressure levels under physiological conditions. Five types of transducers were examined: Epidyn Braun Melsungen, ICT/B-Titan Gaeltec, Camino-OLM-110-4B, Codman MicroSensor ICP-Transducer, Neurovent ICP transducer Rehau Ag+Co. Tests were performed at 6 different pressure levels between 0 mmHg and 50 mmHg. The results show very low drifts of less than 0.15 mmHg degree C-1 for Codman, Epidyn and Neurovent. Gaeltec and Camino exhibited higher drifts of 0.18 mmHg and 0.2 mmHg degree C-1 respectively. Within the temperature range from 35 degrees C to 42 degrees C all probes tested show insignificant temperature drift. Whether these results also apply to other types of transducers needs further evaluation. Problems and requirements related to the design of a laboratory test for the in vitro assessment of ICP transducers are discussed in detail.

Biomedical Engineering↗

A new optical transducer for arterial pressure measurement.

A new optical pressure transducer system (Viggo) has been assessed and compared with a standard P10 transducer (Spectramed) using a similar 20-gauge cannula, both in vitro in terms of linearity and frequency response and in vivo using an animal model. The linearity of the transducers was comparable; the resonant frequencies were 106 Hz and 75 Hz, respectively. However, the resonant frequency of the complete Spectramed system including 150-cm tubing was 11 Hz. The frequencies at which the output amplitude error exceeded 10% of the initial amplitude for the Viggo and for P10 with and without 150-cm tubing were 32 Hz, 24 Hz and 4 Hz, respectively. The principal advantage of the new transducer is that it is sufficiently compact to be mounted directly in the cannula at the wrist, so obviating the use of connecting tubing between the transducer and the cannula.

Animals↗

The importance of measurement of effective transducers radiating area in the testing and calibration of "therapeutic" ultrasonic instruments.

The data presented show early results from a longitudinal survey of "therapeutic" ultrasonic instrument performance in clinical physiotherapy. Previous studies undertaken in North America and the United Kingdom have shown that these units tend not to be scientifically tested and recalibrated, and have been found to have measured outputs at variance with the metered values if tests have been undertaken. This study measured effective transducer radiating area and, concurrently, the total power output at the metered intensity used for the area estimations. Actual output, in terms of total power and space averaged intensity was then compared with expected values derived both from manufacturers' data and from measured transducer radiating area. Only four of eighteen transducers (22%) were within the specified tolerance when actual transducer area was taken into account. Range was 179-31% of expected values. False assumptions of acceptable and unacceptable output can arise from failure to measure actual transducer radiating area.

Calibration↗

An approach for measuring ultrasonic backscattering from biological tissues with focused transducers.

When the standard substitution method is used with a focused transducer to measure the backscattering coefficient from biological tissues including blood, it yields erroneous results. Extending the backscattering measurements to frequencies beyond 15 MHz necessitates the use of focused transducers because of the worsened signal-to-noise ratio--caused by the increased attenuation and the smaller transducer aperture size--in order to make the measurements close to the transducer. An approach which allows the use of focused transducers in backscattering measurements has been developed. It has been used to measure the backscattering coefficient of red cell suspensions of hematocrit ranging from a few percent to 30% in the frequency range from 5 MHz to 30 MHz. The results at hematocrits below 20% agree well with those obtained with the standard substitution method, although they differ as the hematocrit is increased beyond 20%. The experimental results also show that the fourth-power dependence of backscatter on frequency is in general approximately valid for suspended erythrocytes of hematocrit between 6% and 30%.

Animals↗

Narrowband impedance matching layer for high efficiency thickness mode ultrasonic transducers.

A new matching layer design concept has been proposed for narrowband continuous wave (CW) devices. Analysis has shown that the mechanical impedance of a resonant-type transducer in thickness mode CW operation does not equal its acoustic impedance rhoVs but roughly equals rhoVs/Q, where p is density, Vs is acoustic velocity, and Q is the mechanical quality factor. The value of rhoVs/Q is much lower than the acoustic impedance of water for any transducer material, including lead zirconium titanate (PZT), single crystals, or polyvinylidene fluoride (PVDF). With this new approach, the impedance of the matching layer must also be between water and pVs/Q, but there are few such practical low impedance materials. To realize equivalent low impedance structure, a novel double layer design is presented: a relatively low impedance material (such as polyethylene or polyurethane) on the inside and a relatively high impedance material (such as polyester or metal) on the outside. A high power CW transducer structure was designed and fabricated with PVDF-TrFE (polyvinylidene fluoride trifluoroethylene) to operate at 1.4 MHz. The basic quarter wavelength resonator structure is 0.7-mm alumina/0.2-mm piezo-polymer/0.25-mm polyester, and the matching section is 0.2-mm polyurethane and 0.25-mm polyester. A maximum power output of 6 to 9 W/cm2 with conversion efficiency of 30 to 35% was observed. For the transducer without matching section, the observed power was 3 to 4 W/cm2. Mason's model analyses (1) predict that the traditional matching layer is for broadband purposes and reduces output power both for PZT and PVDF-TrFE (2); this new matching scheme can be applied to PZT high power transducer. This high efficiency technique has application in various CW systems, such as Doppler sensors, interferometry, phase-sensitive imaging, or high energy focused beam systems.

Aluminum↗

Design, construction, and evaluation of a bioacoustic transducer testing (BATT) system for respiratory sounds.

Many different transducers are employed for recording respiratory sounds including accelerometers and microphones in couplers. However, there is no standard lung sound transducer or any device to compare transducers so that measurements from different laboratories can be determined to be of physiologic origin rather than technical artifacts of the transducers. To address this problem, we designed and constructed a prototype of a device that can be used to compare accelerometers, microphones enclosed in couplers, and stethoscopes. The prototype device consists of a rigid chamber containing a loudspeaker that opens to an antechamber covered by a viscoelastic material with mechanical properties similar to human skin and subcutaneous tissue. When driven by a white noise source, we found the sound output at the surface to be useful to comparatively evaluate sensors between 100 and 1200 Hz where lung sounds have most of their spectral energy. We compared the viscoelastic layer to similar thicknesses of fresh meat and fat and found them to produce similar acoustic spectra. This device allows air-coupled transducers, accelerometers, and stethoscopes used in respiratory sounds measurements to be compared under physical conditions similar to their intended use.

Acoustics↗

Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers.

The electromechanical coupling coefficient is an important figure of merit of ultrasonic transducers. The transducer bandwidth is determined by the electromechanical coupling efficiency. The coupling coefficient is, by definition, the ratio of delivered mechanical energy to the stored total energy in the transducer. In this paper, we present the calculation and measurement of coupling coefficient for capacitive micromachined ultrasonic transducers (CMUTs). The finite element method (FEM) is used for our calculations, and the FEM results are compared with the analytical results obtained with parallel plate approximation. The effect of series and parallel capacitances in the CMUT also is investigated. The FEM calculations of the CMUT indicate that the electromechanical coupling coefficient is independent of any series capacitance that may exist in the structure. The series capacitance, however, alters the collapse voltage of the membrane. The parallel parasitic capacitance that may exist in a CMUT or is external to the transducer reduces the coupling coefficient at a given bias voltage. At the collapse, regardless of the parasitics, the coupling coefficient reaches unity. Our experimental measurements confirm a coupling coefficient of 0.85 before collapse, and measurements are in agreement with theory.

Computer Simulation↗

Multifrequency ultrasound transducers for conformal interstitial thermal therapy.

Control over the pattern of thermal damage generated by interstitial ultrasound heating applicators can be enhanced by changing the ultrasound frequency during heating. The ability to change transmission frequency from a single transducer through the use of high impedance front layers was investigated in this study. The transmission spectrum of multifrequency transducers was calculated using the KLM equivalent circuit model and verified with experimental measurements on prototype transducers. The addition of a quarter-wavelength thick PZT (unpoled) front layer enabled the transmission of ultrasound at two discrete frequencies, 4.7 and 9.7 MHz, from a transducer with an original resonant frequency of 8.4 MHz. Three frequency transmission at 3.3, 8.4, and 10.8 MHz was possible for a transducer with a half-wavelength thick front layer. Calculations of the predicted thermal lesion size at each transmission frequency indicated that the depth of thermal lesion could be varied by a factor of 1.6 for the quarter-wavelength front layer. Heating experiments performed in excised liver tissue with a dual-frequency applicator confirmed this ability to control the shape of thermal lesions during heating to generate a desired geometry. Practical interstitial designs that enable the generation of shaped thermal lesions are feasible.

Animals↗

A new point contact surface acoustic wave transducer for measurement of acoustoelastic effect of polymethylmethacrylate.

A new acoustic transducer and measurement method have been developed for precise measurement of surface wave velocity. This measurement method is used to investigate the acoustoelastic effects for waves propagating on the surface of a polymethylmethacrylate (PMMA) sample. The transducer uses two miniature conical PZT elements for acoustic wave transmitter and receiver on the sample surface; hence, it can be viewed as a point-source/point-receiver transducer. Acoustic waves are excited and detected with the PZT elements, and the wave velocity can be accurately determined with a cross-correlation waveform comparison method. The transducer and its measurement method are particularly sensitive and accurate in determining small changes in wave velocity; therefore, they are applied to the measurement of acoustoelastic effects in PMMA materials. Both the surface skimming longitudinal wave and Rayleigh surface wave can be simultaneously excited and measured. With a uniaxial-loaded PMMA sample, both acoustoelastic effects for surface skimming longitudinal wave and Rayleigh waves of PMMA are measured. The acoustoelastic coefficients for both types of surface wave motions are simultaneously determined. The transducer and its measurement method provide a practical way for measuring surface stresses nondestructively.

Elasticity↗

Harmonic 3-D echocardiography with a fast-rotating ultrasound transducer.

Although the advantages of three-dimensional (3-D) echocardiography have been acknowledged, its application for routine diagnosis is still very limited. This is mainly due to the relatively long acquisition time. Only recently has this problem been addressed with the introduction of new real-time 3-D echo systems. This paper describes the design, characteristics, and capabilities of an alternative concept for rapid 3-D echocardiographic recordings. The presented fast-rotating ultrasound (FRU)-transducer is based on a 64-element phased array that rotates with a maximum speed of 8 Hz (480 rpm). The large bandwidth of the FRU-transducer makes it highly suitable for tissue and contrast harmonic imaging. The transducer presents itself as a conventional phased-array transducer; therefore, it is easily implemented on existing 2-D echo systems, without additional interfacing. The capabilities of the FRU-transducer are illustrated with in-vitro volume measurements, harmonic imaging in combination with a contrast agent, and a preliminary clinical study.

Echocardiography, Three-Dimensional↗

Determination of an ultrasonic transducer's sensitivity and impedance in a pulse-echo setup.

The role that an ultrasonic piezoelectric transducer plays in an ultrasonic measurement system can be described in terms of the transducer's input electrical impedance and its sensitivity. Here, a new model-based approach is proposed to determine both the transducer impedance and sensitivity in a pulse-echo setup. This new method is much simpler to apply than previous "self-reciprocity" calibration methods for determining sensitivity and generalizes those methods. It is demonstrated that sensitivities obtained with this new method agree well with the sensitivities obtained by a three-transducer method commonly used in calibration studies. It is demonstrated that at the megahertz frequencies at which ultrasonic transducers operate it is important to compensate for cabling effects in these measurements. The influence of the pulser/receiver settings on the results obtained also will be discussed.

Computer-Aided Design↗

A six-degree-of-freedom acoustic transducer for rotation and translation measurements across the knee.

An acoustic transducer design to measure the relative translations and rotations across the knee with no mechanical coupling between the tibia and femur is presented. Platforms attached to femoral and tibial tracking fixtures hold acoustic sources and receivers, respectively. The distance from each source to each receiver is measured by the acoustic transit time and the translations and rotations across the knee joint are computed. For rotations less than 30 deg around the expected operating position, the resolution of the transducer is 0.3 deg; for translations less than 1.5 cm around the expected operating position, the resolution is 0.03 cm. Theoretical error analysis using a Monte Carlo method shows that the uncertainty in the measurement depends on the relative position of the sources and receivers. The analysis predicts the worst case resolution of the transducer as 0.09 cm in translation and 0.6 deg in rotation when the receiver platform is translated 8.0 cm parallel to the source platform. The transducer and fixturing system are demonstrated on a cadaver specimen for applied anterior force and applied internal-external rotation. Errors due to (soft tissue) motion of the transducer relative to the bone during in vivo measurements are assessed on the cadaver specimen. For internal-external rotation the error due to soft tissue motion is a maximum of 0.5 cm in translation and 1.8 deg in rotation. For applied anterior force the error due to soft tissue motion is a maximum of 0.16 cm in translation and 2.7 deg in rotation.

Biomechanical Phenomena↗

Spatial-angular compounding for elastography using beam steering on linear array transducers.

Spatial-angular compounding is a new technique that enables the reduction of noise artifacts in ultrasound elastography. Under this method, compounded elastograms are obtained from a spatially weighted average of local strain estimated from radio frequency (rf) echo signals acquired at different insonification angles. In previous work, the acquisition of the rf signals was performed through the lateral translation of a phased-array transducer. Clinical applications of angular compounding would, however, require the utilization of beam steering on linear-array transducers to obtain angular data sets, which is more efficient than translating phased-array transducers. In this article, we investigate the performance of angular compounding for elastography by using beam steering on a linear-array transducer. Quantitative experimental results demonstrate that spatial angular compounding provides significant improvement in both the elastographic signal-to-noise ratio and the contrast-to-noise ratio. For the linear array transducer used in this study, the optimum angular increment is around 1.5 degrees-3.75 degrees, and the maximum angle that can be used in angular compounding should not exceed 10 degrees.

Artifacts↗

Acoustic field of a wedge-shaped section of a spherical cap transducer.

The acoustic pressure field at an arbitrary point in space is derived for a wedge-shaped section of a spherical cap transducer using the spatial impulse response (SIR) method. For a spherical surface centered at the origin, a wedge shape is created by taking cuts in the X-Y and X-Z planes and removing the smallest surface component. Analytic expressions are derived for the SIR based on spatial location. The expressions utilize the SIR solutions for a spherical cap transducer [Arditi et al., Ultrason. Imaging 3, 37-61 (1981)] with additional terms added to account for the reduced surface area of the wedge. Results from the numerical model are compared to experimental measurements from a wedge transducer with an 8-cm outer diameter and 9-cm geometric focus. The experimental and theoretical -3-dB beamwidths agreed to within 10% +/- 5%. The SIR model for a wedge-shaped transducer is easily extended to other spherically curved transducer geometries that consist of combinations of wedge sections and spherical caps.

Computer Simulation↗

An experimental study of acoustoelectric transducers with nonuniform distribution of the piezoelectric coefficient.

In this paper, an experimental test of a theoretical model published previously is presented that describes the behavior of an acoustoelectric transducer with a nonuniform distribution of the piezoelectric coefficient within its bulk. Results of this theoretical model are first reviewed. Uniform and nonuniform piezoelectric transducers were fabricated, following a procedure described herein. The receive transfer functions of the transducers were recorded experimentally, and a comparison is made with the theoretical transfer functions predicted by the model, which shows good agreement. The transmit transfer functions of the uniform and nonuniform transducers were also measured and are reported. Numerical calculations of the different transfer functions given by the theoretical model for a uniform transducer associated with different backing materials are also presented, and the results are shown to be equivalent to the results following from the Mason equivalent circuit. Comparisons with experimental results and with Mason's equivalent circuit verified the new theoretical model.

Electronics↗

Implications of using colocated strain-based transducers for output active structural acoustic control.

Piezoceramic transducers have become popular elements of smart structures that are used for active vibration control and active structural acoustic control. A spatial differentiation is performed by the piezoceramic transducers since they couple into the strain field of the piezostructure. This differentiation causes higher-frequency modes to be emphasized more heavily, causing the effective compliance of the structure as seen by the piezoceramic transducer to increase with frequency. This nonuniform compliance has significant impact on the performance that can be achieved through colocated direct rate feedback control. It is shown that the rectangular piezoceramic transducer is a low-pass wave number filter with a cutoff frequency inversely proportional to the aperture size. Thus DRFB performance can be greatly improved simply by making the size of the piezoceramic transducer large relative to the size of the structure. The resulting increase in coupling to the lower-frequency modes, which are generally targeted by the control system, results in a much reduced control effort. In the event that a large aperture is not practical, it is shown that dynamic compensation can be used to obtain good performance at the cost of much increased computational complexity. Analytical open and closed loop results for an acoustically radiating simply supported plate piezostructure are presented.

Acoustics↗

Candida parapsilosis fungemia associated with parenteral nutrition and contaminated blood pressure transducers.

During the period September 1983 through May 1985, Candida parapsilosis was isolated from intravascular sites (blood or vascular catheter tips) in 12 patients at a pediatric hospital. Of 205 patients with cultures of any site positive for Candida species, 32 (16%) had cultures positive for C. parapsilosis. In contrast, of 23 patients with intravascular cultures positive for Candida species, 12 (51%) had cultures positive for C. parapsilosis (P less than 0.001, Fisher's exact test). The 12 patients with intravascular cultures positive for C. parapsilosis were more likely to have received central venous nutrition therapy (10 of 12 versus 7 of 23; P less than 0.01, Mantel-Haenzel chi-square test) and had a longer duration of exposure to blood pressure transducers (P less than 0.08, paired t test) than the 23 ward- and age-matched controls. C. parapsilosis was isolated from 11 (32%) of 34 in-use and stored blood pressure transducers. After ethylene oxide sterilization of blood pressure transducers was begun, in-use pressure transducers showed no growth of C. parapsilosis. This study emphasizes the role of C. parapsilosis as a nosocomial pathogen associated with invasive devices and parenteral nutrition; it also emphasizes the importance of adhering to recommended procedures for sterilizing blood pressure transducers.