Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Suction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

[1st results with a new suction curettage system].

The point is a self-developed Suction-curette-system, consisting of a suction-curette of diametres of 3, 4, 5, 6, 7 und 8 mm, a cervicometer and a filter. Effectivity and histological evidence of 1. Suction-curettage after hysterectomy 2. Suction-curettage before hysterectomy in full-narcosis 3. Suction-curettage without full-narcosis were examined. Advantages of this method are discussed.

Adult↗

Optimal suction system for dissection work in surgery.

A new system for improved suction in surgical dissection work is presented, in which the suction tube end has slits. The air suction capacity of the pump is 30 litres a minute, and the maximal vacuum pressure in the systems is limited to -0.3 at by means of a membrane pressure regulator. This system allows a continuous atraumatic suction with adequate suction capacity and convenient operation.

Dissection↗

[Modification of refraction and visual noise perception by suction cup oculocompression].

In 17 ocularly healthy persons the IOP was artificially raised by suction cup oculopression (negative pressure: 65 mmHg [8.67 kPa]) from initially 15.5 +/- 2.2 mmHg (2.07 +/- 0.29 kPa) to 25.2 +/- 4.0 mm Hg (3.36 +/- 0.53 kPa) (mean +/- SD). Continuing the initial refractive correction, visual acuity (Landolt's rings) decreased from initially 1.06 +/- 0.13 to 0.39 +/- 0.22 (P less than 0.001* [*t-test, paired ties each]). A new optical refraction with suction cup in position significantly raised the visual acuity to 0.64 +/- 0.24 (P less than 0.002*). The suction cup itself induced astigmatism of 2.15 +/- 1.46 dpt (Canon Auto-Refractometer RK-1), which significantly differed from the initial astigmatism (0.32 +/- 0.23 dpt) (P less than 0.001*). The minus cylinder axis initially showed no preferential position. During artificial IOP elevation it shifted to 90 degrees...125 degrees (referred to the right eye) and thus ran about perpendicular to the meridian the suction cup was positioned on the eyeball. Effects of such refractive changes on differential light threshold and VEP amplitude are demonstrated. The results presented allow critical interpretation of previous IOP tolerance tests. The influence of suction cup oculopression on the perception of the white-noise field is shown in some glaucoma patients: the speed of the white-noise campimetry allows the increase in field defects during artificial IOP elevation to be followed up directly.

Adult↗

Suction v. conventional curettage in incomplete abortion. A randomised controlled trial.

This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation of the uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0.0001) and a significantly higher mean haemoglobin level at follow-up compared with the 178 patients who had conventional curettage. Suction curettage was a faster procedure and less painful. No difference was found between the two groups with regard to the incidence of post-abortal sepsis, or the re-evacuation rate. No problems were encountered with the use of suction curettage in the presence of uterine sepsis. In an era where blood transfusions should be kept to an absolute minimum, suction curettage will help to save blood in several ways.

Abortion, Incomplete↗

Acoustical factors of noise created by suctioning middle ear fluid.

OBJECTIVE: To quantify the intensity, spectral content, and duration of exposure for suction noise created during aspiration of middle ear fluid following myringotomy. DESIGN: Case series. SETTING: Tertiary care center. PATIENTS OR OTHER PARTICIPANTS: Convenience sample of 245 myringotomies performed on 124 patients ranging in age from 6 months to 14 years (mean age, 2 years 8 months). MAIN OUTCOME MEASURES: Intensity, spectral content, and duration of exposure associated with suction noise were defined by electroacoustic analysis of high-fidelity tape recordings of the noise created during suctioning middle ear fluid. RESULTS: The intensity of suction noise ranged from 74 to 117 dB; most acoustic energy was concentrated in the frequency range between 1.7 and 6.0 kHz, and the duration of exposure varied from 4 to 23 seconds.

Acoustics↗

Techniques of liver resection. Comparison of suction knife, ultrasonic dissector, and contact neodymium-YAG laser.

Liver resections were performed in 18 pigs with an inexpensive disposable plastic suction knife, an ultrasonic dissector, or a contact neodymium (Nd)-YAG laser. Technical aspects and intraoperative and postoperative data were compared. Intraoperative blood loss was less with the suction knife (112 +/- 28 mL) than with the ultrasonic dissector (149 +/- 45 mL) or Nd-YAG laser (174 +/- 25 mL). Operating time was similar in all groups. The number of ligatures used in the Nd-YAG laser group (12 +/- 1) was significantly less than in the ultrasonic dissector (27 +/- 2) or suction knife (32 +/- 2) groups. In the ultrasonic dissector group, there was an increase in postoperative white blood cell count and liver enzyme levels compared with the other two groups. Light microscopy revealed dilated bile ducts in the ultrasonic dissector resection group, which may reflect biliary stasis. There were no significant differences in mortality among the three experimental groups. Results indicated that the ultrasonic dissector and the contact laser method were not substantially better than an inexpensive, easily modified plastic suction catheter in performing a major nonanatomic liver resection in piglets.

Animals↗

Endotracheal suctioning of the neonate: comparison of two methods as a source of mucus material for research.

Endotracheal suctioning in the neonatal intensive care setting is a routine procedure performed to maintain patency of the airway in ventilated infants. Harvested material can also be a source of mucus for research into neonatal respiratory disorders. We aimed to investigate whether the composition of material obtained by our clinically preferred technique of dry shallow suctioning differed significantly from that obtained with saline lavage and deep suctioning. Eleven pairs of dry and saline lavage aspiration samples were compared for neutrophil enzyme myeloperoxidase, total and active alpha(1)-antitrypsin, alpha(1)-antitrypsin complexed with elastase, and secretory leukoprotease inhibitor. Even though individual values of each analyte, expressed per gram of albumin, varied over at least a fivefold range, there was no difference between mean values of dry and lavage samples for any of the constituents. We conclude that the yield of material for research obtained by dry shallow suctioning is adequate and the quality at least as satisfactory as that provided by saline lavage.

Bronchoalveolar Lavage Fluid↗

Closed suction surgical wound drainage after orthopaedic surgery.

BACKGROUND: Closed suction drainage systems are frequently used to drain fluids, particularly blood, from surgical wounds. The aim of these systems is to reduce the occurrence of wound haematomas and infection. OBJECTIVES: To evaluate the effectiveness of closed suction drainage systems for orthopaedic surgery. SEARCH STRATEGY: We searched the Cochrane Musculoskeletal Injuries Group specialised register (May 2001), MEDLINE (1996-May 2001) and references from articles. SELECTION CRITERIA: All randomised or quasi-randomised trials comparing the use of closed suction drainage systems with no drainage systems for all types of elective and emergency orthopaedic surgery. DATA COLLECTION AND ANALYSIS: Both reviewers independently assessed trial quality, using a nine item scale, and extracted data. Wherever appropriate and possible, the data are presented graphically. MAIN RESULTS: Twenty-one studies involving 2772 patients with 2971 wounds were included in the analysis. The types of surgery involved were hip and knee replacement, shoulder surgery, hip fracture surgery, spinal surgery, cruciate ligament reconstruction, open meniscectomy and fracture fixation surgery. Many of the studies had poor methodology and reporting of outcomes. Pooling of results indicated no difference in the incidence of wound infection, haematoma or dehiscence between those allocated to drains and the un-drained wounds. There was a tendency to an increased risk of re-operation for wound complications in the group with drains (relative risk (RR) 2.25, 95% confidence intervals (CI) 0.95 to 5.33), but due to the small numbers of cases involved definite conclusions cannot be made for this outcome. Blood transfusion was required more frequently in those who received drains (RR 1.41, 95% CI 1.10 to 1.80). The need for reinforcement of wound dressings (RR 0.22, 95% CI 0.13 to 0.40) and bruising around the operation site was more common in the group without drains. REVIEWER'S CONCLUSIONS: There is insufficient evidence from randomised trials to support or refute the routine use of closed suction drainage in orthopaedic surgery. Further randomised trials are required before definite conclusions can be made.

Hematoma↗

A trial of suction drainage in inguinal hernia repair.

A prospective randomized trial was conducted on 301 adult males undergoing inguinal herniorrhaphy to assess the value of postoperative suction drainage. Hernias were classified into 'complicated' and 'simple'. In the 'complicated' group suction drainage for 24 h significantly reduced the incidence of wound haematoma, seroma or infection from 48.7 per cent to 17.6 per cent (P < 0.01); there was also a noticeable effect on the postoperative morbidity in the 'simple' hernias, although this just failed to achieve significance (4.5 per cent in the suction group compared with 9.8 per cent in the controls). It is concluded that suction drainage should be employed postoperatively following repair of hernias where dissection may be difficult or where other complicating factors are present.

Clinical Trials as Topic↗

Atraumatic suction tip for microsurgery: technical note.

During microneurosurgery, frequent suction is essential for a successful operative course. A new self-made disposable suction tip is described which facilitates atraumatic suction, even near vital anatomical structures. The efficacy of this suction tip was confirmed in selected operative procedures.

Humans↗

Comparison of throat swabs and nasopharyngeal suction specimens in non-sputum-producing patients with cystic fibrosis.

Both throat swabs and nasopharyngeal suction (NPS) specimens are used for microbiological assessment in non-sputum-producing patients with cystic fibrosis (CF), but studies comparing their diagnostic yield are lacking. We, therefore, conducted a prospective study in young CF patients, in which both techniques were performed in random order. Forty-seven consecutive CF children aged 6 months to 10 years were studied during routine visits to the clinic. CF relevant pathogens were found in the majority of patients with no significant differences in the rate of positive cultures for Staphylococcus aureus, Haemophilus influenzae, or Pseudomonas aeruginosa. A statistically significant difference was observed in the rate of detection of other organisms with only 9/47 (19%) of throat swab specimens and 27/47 (57%) of NPS specimens being positive (P = 0.0004). This included 12 positive cultures for Streptococcus pneumoniae and 11 cultures that were positive for Moraxella catarrhalis, both of which are frequent colonizers of the upper airway. Therefore, the most common bacterial pathogens affecting the CF lung appear to be detected in similar frequency by throat swab as by nasopharyngeal suction. There is evidence that nasopharyngeal suction yields more specimens of Streptococcus pneumoniae and Moraxella catarrhalis, which may reflect upper airway colonization rather than lower airway infection. We conclude that nasopharyngeal suction is not routinely warranted as there is no benefit over throat swab in detection of CF pathogens in infants and young children with CF.

Bacteria↗

Suction fixation system for stereotactic radiosurgery of intraocular malignancies.

We designed a suction fixation system for the radiosurgical treatment of intraocular malignancies with the Leksell gamma unit (gamma knife). OUr device consists of a circular suction chamber and an adjustable unit to be fixed to the Leksell stereotactic head frame. All components are made of plastic materials in order to avoid artifacts in CT or MRT imaging. A permanent suction of 600 to 800 millibars is provided by a standard vacuum pump, powered by a portable battery. Suction times up to 40 minutes were well tolerated in all cases. In the gamma knife of the Neurosurgical Department at the University of Vienna, we successfully used this device. Up to January 1994 we have performed 19 radiosurgical treatments in 9 patients with large or extra-large uveal melanomas and in one patient suffering from a choroidal metastasis.

Aged↗

Open and closed suction drainage after hepatic resection.

A retrospective study was conducted to compare open conduit drains with closed suction drains, with regard to the occurrence of intraperitoneal septic complications after hepatectomy (IPSCH). The subjects comprised 50 consecutive Japanese patients who underwent hepatic resection followed by the insertion of a closed suction drain and the control group comprised 50 patients in whom a simple conduit drain had been placed following liver surgery. There were no significant differences between the two groups in sex, age, underlying liver disease, or the type of hepatectomy performed; nor was there a significant difference in the incidence of IPSCH, the simple conduit drain group versus the closed suction drain group being (10% versus 8%, respectively). However, bile leakage was highly related to IPSCH, the incidence being 60% and 100% in the simple conduit drain and closed suction drain groups, respectively. Thus, to prevent IPSCH, the treatment of bile leakage is a much more important factor than the type of drain used.

Aged↗

Clinical evaluation of closed suction drainage following hepatectomy.

A prospective randomized study on 186 patients was conducted to determine the influence of closed suction drainage (n = 102) versus open drainage (n = 84) on the incidence of postoperative complications after elective hepatic resection. The patients were randomly allocated between the two groups. A total of 60 complications occurred in 31 of the 84 patients (36.9%) given open drainage, while 24 complications occurred in 15 of the 102 patients (14.7%) given closed suction drainage. The incidence of pleural effusion, postoperative ascites, and infected subphrenic collections was significantly lower in the closed suction drainage group than in the open drainage group, at 31% vs 16% (P < 0.05), 19% vs 3% (P < 0.01), and 17% vs 5% (P < 0.05) respectively. However, both groups showed similar rates of subphrenic hematoma and bile collection. These findings indicate that closed suction drainage significantly reduces the incidence of postoperative complications after elective hepatic resection.

Adult↗

Fat suction versus abdominoplasty.

The author describes his fat-suction technique for the treatment of abdominal adiposity. He stresses the importance of the proper selection of patients prior to surgery and the indications for such surgery, analyzing especially the accumulation of subcutaneous adiposity and muscular flaccidity. He divides surgical techniques into four separate groups: isolated fat suction; fat suction associated with infraumbilical cutaneous resection; fat suction associated with conventional abdominoplasty; and, conventional abdominoplasty. The criteria of indications for each separate procedure are strongly emphasized.

Abdominal Muscles↗

Respiratory physiotherapy vs. suction: the effects on respiratory function in ventilated infants and children.

OBJECTIVE: To assess and compare the effects of physiotherapy and suction on expired tidal volume (V(TE)), respiratory compliance (C(rs)), resistance (R(rs)) and arterial blood gases. DESIGN: Randomised cross-over study comparing outcomes after both treatments on the same day. SETTING: Intensive tertiary care units, Great Ormond Street Hospital, London. PATIENTS: One hundred children on full ventilatory support requiring physiotherapy. Paired measurements were obtained in 90 participants, and 7 others were excluded because of tracheal tube leak. INTERVENTIONS: Respiratory physiotherapy and suction. MEASUREMENTS AND RESULTS: Physiotherapy lasted longer and required more saline and catheters per treatment. There were no significant group changes in V(TE) or C(rs) after either treatment, but a tendency for R(rs )to fall following physiotherapy which reached significance in patients on volume-preset ventilation. There were also small but statistically significant reductions in HCO(3)(-), base excess and SaO(2) after physiotherapy. V(TE) and C(rs) increased and R(rs) decreased in excess of their 95% limits of agreement for normal variability in approximately twice as many subjects following physiotherapy than suction, these differences being significant for V(TE) and approaching significance for C(rs) and R(rs). CONCLUSIONS: Physiotherapy appeared to have an advantage in reducing R(rs )in some patients, but also produced changes in derived blood gas parameters. Within individuals, physiotherapy treatments were also more likely to produce improvements in V(TE), C(rs) and R(rs) than suction. Further research should identify sensitive patient selection criteria and assess longer-term effects of such treatments.

Child↗

Report of experience in 190 patients with the use of closed suction drainage in arthroscopic knee procedures.

The goal of this study is to report our experience with the use of suction drainage for various arthroscopic knee procedures. One hundred and ninety patients who underwent arthroscopic knee procedures participated in the study, and were divided into two groups (Group 1: Suction drainage, Group 2: No suction drainage). For every patient, the following parameters were recorded: age, gender, operative time, tourniquet or pump use, the amount of fluid collected in the hemovac drain, presence of meniscal tear, type of the operative procedure, date of the operation, and presence of effusion at the follow-up. Statistical analysis was performed to detect any significant statistical difference between the amount of fluid collected in the hemovac drain and the other mentioned parameters in Group 1; and these patients were divided into four subgroups to facilitate the statistical evaluation between the procedures and the amount of fluid collected in the hemovac drain. The partial meniscectomy subgroup had significantly lower amounts of collected fluid when compared to the subtotal meniscectomy subgroup. Drilling of the osteochondral faces led to significantly higher amounts of fluid when compared to non-drilling cases. Use of an infusion pump during surgery and shorter operation time led to lower amounts of fluid to be collected. No case in either main group suffered from effusion at the follow-up. Our investigation demonstrated that in different arthroscopic interventions, variable amounts of fluid can be collected in the hemovac drains. Subtotal meniscal resection, drilling of the osteochondral faces and longer duration of the operation increase the amount of fluid. In cases of partial meniscal resection and/or chondral debridement, limited synovial and plica resection, suction drainage is unnecessary.

Adolescent↗

Laparoscopic splenectomy. How to make it easier using an innovative atraumatic suction grasper.

BACKGROUND: With the evolution of laparoscopic surgery comes the need for specific instruments that apply traction to parenchymal tissue, like the spleen, without exposing the organ to the associated high risk of bleeding. To meet this need, we designed and developed a suction-cup grasper that allows easy grasping and manipulation of the spleen. Some of the difficulties usually encountered during laparoscopic splenectomy may be overcome by using this device. MATERIALS: The instrument consists of a cone-shaped, silicone rubber suction cup designed with an antislip internal surface. The cup is connected to a support arm with a flexible distal end that can be rotated. Traction is exerted with a commonly available suction system. The device is inserted through a 12-mm-diameter guide sheath. RESULTS: The two interventions performed with the atraumatic device were completed with laparoscopic technique. No complications arose during or after the operations. The average operating time was 110 min. The patients were discharged after 4 and 5 days postoperative, respectively. CONCLUSIONS: As a device specifically designed for grasping parenchymal organs, the atraumatic suction grasper affords the operator a faster and safer technique in laparoscopic splenectomy.

Equipment Design↗