Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RESPIRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Modulating effect of respiration on atrioventricular conduction time assessed using PR interval variation.

Respiratory sinus arrhythmia (RSA) is the variation of heart rate (or RR interval) in phase with respiration and has been extensively studied. However, the effect of respiration on atrioventricular conduction delay (and hence PR interval length) has not yet received much attention. This work reports on measurements of respiration and associated RR and PR variability, in 11 subjects, assessed through surface electrocardiogram measurements, for both paced and spontaneous respiration in the supine position. A wavelet-based approach was used to extract RR and PR intervals. The accuracy of RR and PR interval measurement was consistent with previously published work. Respiratory atrioventricular conduction delay variability (RCV) was assessed using three techniques: spectral, peak-to-trough and cosinor methods. All measures showed statistically significant variations in PR interval due to respiration during paced respiration at 6 min(-1). Of the three measures, cosinor analysis was most reliable in highlighting RCV. Using this measure, statistically significant RCV was seen in ten out of the 11 subjects during paced respiration. The magnitude of the variability was estimated as +/- 5.9% of the mean PR interval. In spontaneous respiration, statistically significant RCV was seen in approximately half of the subjects, with an estimated variability of +/- 1.5%. As a control, statistically significant values for RSA were also obtained from the same data, which agreed with previously published measurements. It was concluded that respiration does indeed modulate atrioventricular conduction delay, deep breathing in the supine position accentuates this effect, and cosinor analysis provides a reliable means for quantifying this effect.

Adult↗

Impaired postural compensation for respiration in people with recurrent low back pain.

This study evaluated the degree to which the disturbance to posture from respiration is compensated for in healthy normals and whether this is different in people with recurrent low back pain (LBP), and to compare the changes when respiratory demand is increased. Angular displacement of the lumbar spine and hips, and motion of the centre of pressure (COP), were recorded with high resolution and respiratory phase was recorded from ribcage motion. With subjects standing in a relaxed posture, recordings were made during quiet breathing, while breathing with increased dead-space to induce hypercapnoea, and while subjects voluntarily increased their respiration to match ribcage expansion that was induced in the hypercapnoea condition. The relationship between respiration and the movement parameters was measured from the coherence between breathing and COP and angular motion at the frequency of respiration, and from averages triggered from the respiratory data. Small angular changes in the lumbopelvic and hip angles were evident at the frequency of respiration in both groups. However, in quiet standing, the LBP subjects had a greater displacement of their COP that was associated with respiration than the control subjects. The LBP group had a trend for less hip motion. There were no changes in the movement parameters when respiratory demand increased involuntarily via hypercapnoea, but when respiration increased voluntarily, the amplitude of motion and the displacement of the COP increased in both groups. The present data suggest that the postural compensation to respiration counteracts at least part of the disturbance to posture caused by respiration and that this compensation may be less effective in people with LBP.

Adult↗

Seasonal, daily and diurnal variations in the stable carbon isotope composition of carbon dioxide respired by tree trunks in a deciduous oak forest.

The stable C isotope composition (delta13C) of CO2 respired by trunks was examined in a mature temperate deciduous oak forest (Quercus petraea). Month-to-month, day-to-day and diurnal, measurements were made to determine the range of variations at different temporal scales. Trunk growth and respiration rates were assessed. Phloem tissue was sampled and was analysed for total organic matter and soluble sugar 13C composition. The CO2 respired by trunk was always enriched in 13C relative to the total organic matter, sometimes by as much as 5 per thousand. The delta13C of respired CO2 exhibited a large seasonal variation (3.3 per thousand), with a relative maximum at the beginning of the growth period. The lowest values occurred in summer when the respiration rates were maximal. After the cessation of radial trunk growth, the respired CO2 delta13C values showed a progressive increase, which was linked to a parallel increase in soluble sugar content in the phloem tissue (R=0.95; P<0.01). At the same time, the respiration rates declined. This limited use of the substrate pool might allow the discrimination during respiration to be more strongly expressed. The late-season increase in CO2 delta13C might also be linked to a shift from recently assimilated C to reserves. At the seasonal scale, CO2 delta13C was negatively correlated with air temperature (R=-0.80; P<0.01). The diurnal variation sometimes reached 3 per thousand, but the range and the pattern depended on the period within the growing season. Contrary to expectations, diurnal variations were maximal in winter and spring when the leaves were missing or not totally functional. By contrast to the seasonal scale, these diurnal variations were not related to air temperature or sugar content. Our study shows that seasonal and diurnal variations of respired 13C exhibited a similar large range but were probably explained by different mechanisms.

Analysis of Variance↗

Control of respiration and of motility in ejaculated bull spermatozoa.

The relations between motility and respiration were studied in ejaculated bull spermatozoa respiring with lactate. Motility was quantitatively evaluated by a turbidimetric procedure as percentage of cells moving per minute from the bottom of the cuvette into the light path. For selective inhibition of ATP-consuming reactions including motility or of mitochondrial respiration, vanadate or cyanide, respectively, were used. Both inhibitors were found to produce proportional changes in motility and respiration. The simultaneous changes in motility and respiration were linked to shifts in the cellular ATP/ADP ratio. Partial uncoupling of respiration in vanadate-inhibited cells gave similar relations between respiration and ATP/ADP ratios as stepwise inhibition of ATP-utilizing reactions by vanadate. Presuming saturation kinetics with respect to the ATP/ADP ratio, half maximum constants of 1.7 and 4.7 for the ATP/ADP ratio and maximum values of about 130% and 300% (in comparison to untreated cells) were estimated for motility and respiration, respectively. Respiration showed a much steeper dependence on the ATP/ADP ratio than motility resulting in an apparent cooperativity coefficient of 2.9. From these dependences on the ATP/ADP ratio, the shares in the control of ATP turnover in untreated cells were estimated. At sufficient supply with substrate, more than 80% of control were excreted by motility and other ATP-utilizing reactions, the rest by mitochondrial ATP production, i.e., the reactions of oxidative phosphorylation.

Adenosine Diphosphate↗

Effect of inhibitors of electron transport and oxidative phosphorylation on Trypanosoma cruzi respiration and growth.

Antimycin A and 2-heptyl-4-hydroxyquinoline N-oxide, two specific inhibitors of the b-c1 segment of the respiratory chain, affected the respiration of Trypanosoma cruzi epimastigote forms. The half-maximum inhibitory concentrations were about 0.05 and 4.0 micrograms/mg cells (dry wt.), respectively. The maximum effect of antimycin (about 80% inhibition of respiration) was at about 0.1 microgram antimycin/mg cells. Differential spectrophotometry of T. cruzi epimastigotes in the presence of antimycin, cyanide (or sulfide) and uncouplers, revealed the presence of functional cytochromes aa3, b and c558. In the stationary growth phase respiration by T. cruzi was completely inhibited by cyanide and effectively inhibited by sulfide, but in the exponential growth phase respiration was about 20% insensitive to 5 mM cyanide. Cyanide- and antimycin-insensitive respiration was completely inhibited by salicylhydroxamic acid (2 mM). Antimycin inhibited the operation of the tricarboxylic acids cycle in T. cruzi, as shown by the lesser production of 14CO2 and by the modification of 14C distribution in epimastigotes incubated with [1-14C]glucose, [2-14C]acetate or NaH14CO3. The inhibition of electron transport by antimycin increased the rate of the fumarate reductase reaction, an alternative electron pathway for the oxidation of reduced pyridine nucleotides. Addition of carbonyl cyanide 3-chlorophenylhydrazone to epimastigotes increased the rate of respiration and promoted the oxidation of reduced cytochrome b components, thus showing that these components are subject to respiratory (acceptor) control. Pentachlorophenol similarly affected the cytochrome b redox level but did not modify the rate of respiration. The uncouplers released N,N'-dicyclohexylcarbodiimide inhibition of respiration, and uncouplers and cyanide significantly decreased the ATP level in epimastigotes. The combined effects of the assay inhibitors on respiration, cytochrome b redox level, ATP content and energy charge confirmed the operation of oxidative phosphorylation in T. cruzi epimastigotes. Antimycin, uncouplers and N,N'-dicyclohexylcarbodiimide inhibited growth of T. cruzi, thus proving the essential role of oxidative phosphorylation for the parasite.

Adenosine Triphosphate↗

Evaluation of single-use masks and respirators for protection of health care workers against mycobacterial aerosols.

BACKGROUND: The recent increase in multidrug-resistant tuberculosis has spawned a major controversy concerning the degree of respiratory protection needed by health care workers, particularly during sputum-inducing procedures. The objective of this study was to measure the filtration efficiencies of a single-use submicron surgical mask, two disposable dust/mist respirators, a dust/mist/fume respirator, and a high-efficiency particulate air respirator against aerosolized mycobacteria. Facial fit was not addressed. METHODS: In a specially designed enclosed test apparatus, an aerosol was generated with a Collison nebulizer from a known concentration of Mycobacteria chelonae, used as a surrogate for Mycobacterium tuberculosis. Aerosol concentrations were measured with Anderson samplers upstream and downstream of the test masks and respirators, which were heat sealed to a metal plate. RESULTS: Mean efficiencies ranged from approximately 97% for the surgical mask and a dust/mist respirator to more than 99.99% for the high-efficiency particulate air respirator. Measurements of filter efficiency with an Aerodynamic Particle Sizer for the M. chelonae aerosol and independent challenge tests with latex spheres correlated closely with measurements of M. Chelonae collection efficiency determined with Andersen samplers. CONCLUSIONS: Analysis of variance and Tukey's method for multiple comparisons indicated that the dust/mist/fume respirator and the HEPA respirator collected M. chelonae with significantly greater efficiency than did either the surgical mask or the dust/mist respirator. Even the least efficient mask tested, however, had a filter efficiency of more than 97% against particles averaging less than 1 micron in aerodynamic diameter.

Aerosols↗

Hypolipidemic agents alter hepatic mitochondrial respiration in vitro.

The direct effects of three different classes of structurally diverse hypolipidemic agents on respiration were studied in mitochondria isolated from donor Sprague-Dawley rats. Two classes of peroxisome proliferators (i.e. plasticizers and hypolipidemic hormones and drugs) and one class of peroxisome inhibitors (i.e. anti-psychotic drugs) were studied. The phthalate ester plasticizers dibutylphthalate, ethylhexanoic acid and di(2-ethylhexyl) adipate, the hypolipidemic hormones or drugs dehydro-epiandrosterone (DHEA), thyroxine (T4), triiodothyronine (T3), gemfibrozil, clofibrate and naphthoflavone, and the anti-psychotic drugs chlorpromazine, thioridazine and fluphenazine were studied. As the dose of the plasticizer dibutylphthalate increased from 8 to 200 mumol/l, there was a decrease (P < 0.05) in state 3 (+ADP) respiration and in the respiratory control ratio for both substrates tested. The anti-psychotic drug chlorpromazine decreased state 3 malate + pyruvate-supported respiration and increased state 3 succinate-supported respiration. As the concentration of all three anti-psychotic drugs increased, there was a linear increase in state 4 respiration (-ADP) and a decrease in the respiratory control ratio for both substrates tested. As the dose of the hypolipidemic agents DHEA, gemfibrozil and T4 increased, there was a linear reduction in state 3 malate + pyruvate-supported respiration. However, when succinate was used as the substrate to support respiration, only the thyroid hormones significantly decreased state 3 respiration. Gemfibrozil, T4 and T3 increased state 4 respiration, regardless of the substrate used. As the dose of clofibrate, gemfibrozil, and the thyroid hormones increased, there was a linear reduction in the respiratory control ratio for both substrates tested.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine Diphosphate↗

Different effects of chilling on respiration in leaves and roots of cucumber (Cucumis sativus).

The effects of chilling on respiration (SHAM-resistant, cytochrome pathway and KCN-resistant, alternative pathway), temperature sensitivity, relative electrolyte conductivity, and degrees of oxidative stress (H(2)O(2) and malonaldehyde (MDA) contents) were separately examined in leaves and roots of cucumber (Cucumis sativus L.). After chilling at 8 degrees C for 4 days, both total respiration and KCN-resistant respiration in roots increased at different measurement temperatures. In contrast, SHAM-resistant respiration remained unchanged. In comparison, chilling significantly decreased the total respiration in leaves and this decrease was mostly due to a decrease in SHAM-resistant respiration. Chilling apparently decreased the sensitivity of KCN-resistant respiration to changes of temperature. The reduction levels of ubiquinone pool (UQr/UQt) increased both in chilled leaves and roots whilst pyruvate content increased only in chilled roots, but not in chilled leaves. Furthermore increases of H(2)O(2) and MDA contents were much greater in leaves than in roots. The same trend was also observed for ion leakage from tissues. Taken together, the results suggested that the higher chilling tolerance of roots was associated with their high total respiration and KCN-resistant respiration.

Cold Temperature↗

Respiration profiles in monitoring the composting of by-products from the olive oil agro-industry.

The composting of olive press cake (OPC) repeatedly mixed either with olive mill wastewater (OPC+OMW) or with tap water (OPC+W) was studied using the thermogradient respirometer, an apparatus that determines the respiration rates from a substrate over a wide range of different temperatures (respiratory profile). The composting processes took place over a period of five months during which nine moistenings of the OPC were performed with the respective liquids. The composting resulted in detoxification of the materials used in both treatments, as indicated by seed germination tests. However, the repeated applications of OMW resulted in recurring thermophilic phases (following each application) and in greater pH and conductivity increases in the final product, as compared to water applications. Respiration measurements performed at 35 degrees C were good indicators of the mean metabolic potential in the compost piles (the mean respiration derived from the whole respiration profile over a wide range of environmental temperatures). However, respiration measurements at higher temperatures (48.5 degrees C) were better indicators of the respiration activity occurring in situ. Following the initial thermophilic phase, the respiration potential of the composts at high temperatures (42-63 degrees C) increased drastically compared to their respiration potential at lower temperatures (17-42 degrees C) indicating the establishment of a thermophilic microflora. Subsequently, only the periodic new substrate-C applications in the form of OMW resulted in increased ratios of low temperature-to-high temperature respiration potential. These ratios decreased again following the respective thermophilic phase that each new OMW application had induced.

Agriculture↗

The O2-dependence of respiration and H2O2 production in the parasitic nematode Ascaridia galli.

1. Respiration in the parasitic nematode worm Ascaridia galli was inhibited at O2 concentrations in excess of 255 microM, and an apparent Km,O2 of 174 microM was determined. 2. Mitochondria-enriched fractions isolated from the tissues of A. galli have much lower apparent Km,O2 values (approx. 5 microM). They produce H2O2 in the energized state; higher rates of H2O2 production were observed in the presence of the uncoupler carbonyl cyanide m-chlorophenylhydrazone. 3. Antimycin A inhibited respiration in muscle tissue mitochondria by 10%, but had no effect on respiration in gut + reproductive tissue mitochondria; the major portion of respiration in both types of mitochondria could be attributed to an alternative electron-transport pathway. 4. o-Hydroxydiphenyl, an inhibitor of alternative electron-transport pathways, inhibits respiration by 98% and completely inhibits the production of H2O2 in gut-plus-reproductive-tissue mitochondria; respiration and H2O2 production in muscle tissue mitochondria were inhibited by 90 and 86% respectively. 5. Another inhibitor of alternative electron transport, salicylhydroxamic acid, had the same effect as o-hydroxydiphenyl on H2O2 production and respiration in gut-plus-reproductive-tissue mitochondria. However, its effect on muscle tissue mitochondria was complex; a low concentration (0.35 mM) stimulated H2O2 production, whereas 3 mM inhibited respiration by 87% and prevented H2O2 production completely. 6. The similarities between the apparent Km,O2 values for H2O2 production and respiration in muscle mitochondria and in gut-plus-reproductive-tissue mitochondria suggests that the site of H2O2 production on the alternative electron-transport chain is cytochrome 'o'. 7. These results are discussed in relation to potential O2 toxicity in A. galli.

Animals↗

Linoleic acid-induced activity of plant uncoupling mitochondrial protein in purified tomato fruit mitochondria during resting, phosphorylating, and progressively uncoupled respiration.

An uncoupling protein was recently discovered in plant mitochondria and demonstrated to function similarly to the uncoupling protein of brown adipose tissue. In this work, green tomato fruit mitochondria were purified on a self-generating Percoll gradient in the presence of 0.5% bovine serum albumin to deplete mitochondria of endogenous free fatty acids. The uncoupling protein activity was induced by the addition of linoleic acid during the resting state, and in the progressively uncoupled state, as well as during phosphorylating respiration in the presence of benzohydroxamic acid, an inhibitor of the alternative oxidase and with succinate (+ rotenone) as oxidizable substrate. Linoleic acid strongly stimulated the resting respiration in fatty acid-depleted mitochondria but had no effect on phosphorylating respiration, suggesting no activity of the uncoupling protein in this respiratory state. Progressive uncoupling of state 4 respiration decreased the stimulation by linoleic acid. The similar respiratory rates in phosphorylating and fully uncoupled respiration in the presence and absence of linoleic acid suggested that a rate-limiting step on the dehydrogenase side of the respiratory chain was responsible for the insensitivity of phosphorylating respiration to linoleic acid. Indeed, the ADP/O ratio determined by ADP/O pulse method was decreased by linoleic acid, indicating that uncoupling protein was active during phosphorylating respiration and was able to divert energy from oxidative phosphorylation. Moreover, the respiration rates appeared to be determined by membrane potential independently of the presence of linoleic acid, indicating that linoleic acid-induced stimulation of respiration is due to a pure protonophoric activity without any direct effect on the electron transport chain.

Carbonyl Cyanide p-Trifluoromethoxyphenylhydrazone↗

Evaluation and field calibration of the Miniram PDM-3 aerosol monitor for measuring respirable and total coal dust.

The MIE Miniram PDM-3 is a real-time aerosol dust monitor designed to measure dust based on Mie scattering. It has an optional in-line filter that, when attached to a constant flow air sampling pump, allows a gravimetric air sample to be collected from the same air stream that passes through the Miniram sensing chamber. This study compared real-time Miniram digital respirable and total dust readings with concentrations from an in-line 5 microns polyvinyl chloride filter connected to a constant flow pump and with results from traditional respirable and total dust samples. Area samples were collected at three coal-fired power generating facilities over a 2-month period. Traditional respirable dust concentrations ranged from 0.04 to 10.8 mg/m3. In the monitored range of concentrations the Miniram respirable concentrations and the in-line respirable dust concentrations were not significantly different (p > or = 0.05), nor were the Miniram in-line filter concentrations and the side-by-side respirable dust concentrations significantly different (p > or = 0.05). However, the Miniram respirable concentrations and the traditional respirable concentrations were significantly different (p = 0.02). The Statistical Analysis System (SAS) procedure CALIS, which meets the statistical requirements for developing calibration lines for two variables each measured with error, is used to develop field calibration curves for the comparisons between direct-reading instrument concentrations and concentrations from traditional National Institute for Occupational Safety and Health methods for total and respirable dust.

Aerosols↗

Electrostatic N-95 respirator filter media efficiency degradation resulting from intermittent sodium chloride aerosol exposure.

The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.

Aerosols↗

Exposures of geotechnical laboratory workers to respirable crystalline silica.

Geotechnical laboratory testing involves the determination of the physical properties of soil, rock, and other building materials for engineering purposes. Individuals working in these laboratories are exposed to airborne soil, rock, and other dusts during the preparation and testing of these materials. Crystalline silica as quartz is a common constituent of these materials and represents a potential hazard to geotechnical laboratory workers when airborne as a respirable dust. The authors conducted an examination of the potential for geotechnical laboratory workers to be exposed to respirable dust and respirable quartz during the performance of three routine laboratory tasks. A task-based exposure assessment strategy was used. Although respirable dust was generated during the performance of each of these tasks, its impact on exposures was generally overridden by the presence of respirable quartz in the dust. Quartz content in the respirable dust ranged from below the detection limit to greater than 50 percent. Mean exposure to respirable quartz, based on the duration of the task and assuming no other exposures for the rest of the 8-hour day, exceeded the National Institute for Occupational Safety and Health (NIOSH) "action level" (the exposure level at which certain actions must be taken) of 0.025 mg/m3. If exposure was assumed to continue for the rest of the 8-hour day at the measured concentration, mean exposure to respirable quartz exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) time-weighted average (TWA), the Occupational Safety and Health Administration (OSHA) PEL, and the NIOSH REL. Seven percent of 57 individual task exposure measurements exceeded the TLV-TWA and the PEL, 18 percent exceeded the REL, and another 12 percent exceeded excursion limits as defined by ACGIH. The results of this study support the conclusion that geotechnical laboratory workers are potentially exposed to respirable crystalline silica as quartz at levels that may be harmful. Because the quartz content of the materials being tested in these laboratories is highly variable and is almost never determined prior to testing, all materials being tested in the geotechnical laboratory should be assumed to contain quartz. Appropriate controls should be used to protect workers from inhaling dusts generated from these materials.

Geological Phenomena↗

Assessment of the effectiveness of respirator usage in coke oven workers.

This program protection factor study was conducted to evaluate the effectiveness of filter cartridge respirators while coke oven workers performed their normal work. Benzene soluble fraction (BSF) of total particulate concentrations was measured inside and outside the respirators of nine coke oven workers who worked on the top of the battery of one older coke oven plant and who reported regular use of respirators. The measurements were taken for 3 consecutive days. Excluding two undetectable measurements inside the respirator, it was found that the outside respirator BSF concentrations (25 sets) ranged from 87 to 807 microg/m3, whereas the inside respirator BSF concentrations ranged from 16 to 509 microg/m3. A program protection factor (PPF) for each set of observations was calculated as the ratio of outside to inside air BSF concentrations. The mean PPF was 2.5 with a range of 1.1 to 9.6, and 12 of the 25 measurements (48%) were below 2.0. Although the workers claimed they regularly wore their respirators, the wide range and the low PPF findings suggest that worker behavior and respirator fit may influence the level of protection provided by the respirator.

Air Pollutants, Occupational↗

Cognitive performance during respirator wear in the absence of other stressors.

Reaction time, decision-making speed, and response accuracy were measured in 12 male and 5 female subjects performing computer-controlled tasks under nonexercise conditions during two 3.5-hour days, one with and one without (control) wearing a respirator, to assess the effects of respirator wear alone on cognitive performance. Tasks included measures of simple and choice reaction time (CRT), serial pattern matching, lexical discrimination (LD), visual selective attention, rapid visual scanning, and form discrimination (FD). Anxiety levels were assessed along with reaction time measures obtained at the start of each test day and after 1, 2, and 3 hours of testing. Reaction time and response accuracy did not differ significantly between respirator and control trials and were not changed over time. However, mean decision-making times were significantly faster during respirator wear compared to control for the LD (0.17 +/- 0.04 versus 0.19 +/- 0.05 sec) and FD (0.32 +/- 0.10 versus 0.36 +/- 0.12 sec) CRT tasks. Females exhibited significantly faster reaction times than males, but no differences within sex groups were observed between control and respirator trials. Response accuracy and decision-making speed did not differ within and between male and female groups for any reaction time tasks during respirator wear. The improvements in decision-making time observed during respirator wear probably reflect the effect of the respirator to increase arousal and improve focusing of attention by excluding peripheral visual stimuli. Furthermore, the results suggest that respirator wear over a relatively short period in the absence of other stressors should not inhibit cognitive function.

Adult↗

An evaluation of respirator maintenance requirements.

A telephone survey was developed as part of a pilot study to evaluate the inspection, cleaning, maintenance, and storage aspects of respirator protection programs (RPP). Regulations and consensus standards such as those published by the Occupational Safety and Health Administration in the Code of Federal Regulations (CFR) or the American National Standards Institute (ANSI) require or recommend that RPP contain elements that ensure that the respirators provide proper protection. A great deal of research has been done to evaluate the effectiveness of new respirators; however, little research has been conducted to evaluate how respirators behave over time in real industrial settings Respirator inspection, cleaning, maintenance, and storage are significant factors in determining how well a respirator continues to perform. The telephone survey was developed by reviewing the requirements and recommendations of CFR 1910.134 and ANSI Z88.2-1980. Approximately 30 companies were selected based on their use of negative air-purifying respirators. Most of the companies represented the hardgoods manufacturing or service industries. Although the majority of companies were meeting requirements, responses indicated that the following improvements in RPP were necessary: (1) inspection of all respirator parts should be carried out before and after each use, (2) replacement parts should be made readily available on site, (3) regular cleaning should be performed, and (4) more hands-on practice with respirators and their maintenance should be incorporated into training sessions.

Equipment Failure↗

Errors associated with three methods of assessing respirator fit.

Three fit test methods (Bitrex, saccharin, and TSI PortaCount Plus with the N95-Companion) were evaluated for their ability to identify wearers of respirators that do not provide adequate protection during a simulated workplace test. Thirty models of NIOSH-certified N95 half-facepiece respirators (15 filtering-facepiece models and 15 elastomeric models) were tested by a panel of 25 subjects using each of the three fit testing methods. Fit testing results were compared to 5th percentiles of simulated workplace protection factors. Alpha errors (the chance of failing a fit test in error) for all 30 respirators were 71% for the Bitrex method, 68% for the saccharin method, and 40% for the Companion method. Beta errors (the chance of passing a fit test in error) for all 30 respirator models combined were 8% for the Bitrex method, 8% for the saccharin method, and 9% for the Companion method. The three fit test methods had different error rates when assessed with filtering facepieces and when assessed with elastomeric respirators. For example, beta errors for the three fit test methods assessed with the 15 filtering facepiece respirators were < or = 5% but ranged from 14% to 21% when assessed with the 15 elastomeric respirators. To predict what happens in a realistic fit testing program, the data were also used to estimate the alpha and beta errors for a simulated respiratory protection program in which a wearer is given up to three trials with one respirator model to pass a fit test before moving onto another model. A subject passing with any of the three methods was considered to have passed the fit test program. The alpha and beta errors for the fit testing in this simulated respiratory protection program were 29% and 19%, respectively. Thus, it is estimated, under the conditions of the simulation, that roughly one in three respirator wearers receiving the expected reduction in exposure (with a particular model) will fail to pass (with that particular model), and that roughly one in five wearers receiving less reduction in exposure than expected will pass the fit testing program in error.

Adult↗