Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIATION MONITORING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination.

A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

Hazardous Substances↗

Experimental studies on the role of antibody fragments in cancer radio-immunotherapy: Influence of radiation dose and dose rate on toxicity and anti-tumor efficacy.

Whereas bivalent fragments have been widely used for radio-immunotherapy, no systematic study has been published on the therapeutic performance of monovalent conjugates in vivo. The aim of our study was, therefore, to determine the therapeutic performance of (131)I-labeled Fab as compared to bivalent conjugates and to analyze factors that influence dose-limiting organ toxicity and anti-tumor efficacy. The maximum tolerated doses (MTDs) and dose-limiting organ toxicities of the (131)I-labeled anti-CEA antibody MN-14 [IgG, F(ab')2 and Fab] were determined in nude mice bearing s.c. human colon cancer xenografts. Mice were treated with or without bone marrow transplantation (BMT) or inhibition of the renal accretion of antibody fragments by D-lysine or combinations thereof. Toxicity and tumor growth were monitored. Radiation dosimetry was calculated from biodistribution data. With all 3 (131)I-labeled immunoconjugates [IgG, F(ab')2 and Fab], the red marrow was the only dose-limiting organ; MTDs were 260 microCi for IgG, 1,200 microCi for F(ab')2 and 3 mCi for Fab, corresponding to blood doses of 17 Gy, 9 Gy and 4 Gy, respectively. However, initial dose rates were 10 times higher with Fab as compared to IgG and 3 times higher as compared to F(ab')2. The MTD of all 3 immunoconjugates was increased by BMT by approximately 30%. In accordance with renal doses below 10 Gy, no signs of nephrotoxicity were observed. Despite lower absorbed tumor doses, at equitoxic dosing, Fab fragments were more effective at controlling tumor growth than the respective bivalent fragment or IgG, probably due to higher intratumoral dose rates. Our data indicate that the improved anti-tumor effectiveness of antibody fragments as compared to IgG and the higher myelotoxicity at comparably lower red marrow doses are most likely due to the higher initial dose rates observed with antibody fragments.

Animals↗

Thallium-201-chloride scintigraphy in staging and monitoring radiotherapy response in follicular lymphoma patients.

PURPOSE: To study thallium-201-chloride scintigraphy (201Tl-S) in staging and monitoring response after radiotherapy in follicular lymphoma (FL) patients. PATIENTS AND METHODS: Forty-one consecutive and unselected FL patients were examined by 'Conventional Standard Staging' (CSS) procedures (history and physical examination, ultrasound, CT scans, biopsies and fine needle aspiration cytology) prior to irradiation. Eight standardized potentially affected lymphoma localizations (neck, axilla, mediastinum, spleen, paraaortic, parailiac, femoral and extranodal) per patient were separately studied, resulting in the investigation of 328 localizations. Thirty minutes after the intravenous administration of a tracer dose of 150 MBq thallium-201-chloride total body images were made, immediately followed by single photon emission computed tomography acquisition. All lymphoma localizations were subsequently irradiated. Patients were re-examined after a median of 4 weeks (range 3-6 weeks) by all CSS modalities and 201Tl-S. Diagnostic performance was evaluated both per site and per patient, both in the diagnostic phase of the study as well as in the post-treatment re-evaluation phase. RESULTS: In staging, 201Tl-S was positive in 82 of the 129 initial positive regions by CSS (64%). This percentage increased to 70% when eliminating upper abdominal lymph nodes from the analysis. In 24 patients all lesions were visualized by 201Tl-S, in 11 patients some but not all lesions were detected. In six patients none of the lesions were detected by 201Tl-S. In four patients, four additional lesions were initially found by 201Tl-S only. After irradiation, 83 of the total 86 positive regions reached a complete or partial remission by CSS. Eighty-one of these were also diagnosed as remission by 201Tl-S and two as stable disease. In 31 out of 35 patients (89%; 95% CI: 73-97%) the overall response in all irradiated sites was identical by 201Tl-S and CSS. Only two patients, in remission on CSS modalities, showed stable disease on 201Tl-S, while two others were diagnosed as CR by CSS and PR by 201Tl-S. CONCLUSIONS: 201Tl-S has limited additional value in staging FL patients, since only two-thirds of all localizations are detected. However, 201Tl-S is accurate in monitoring radiation treatment response in FL patients. If an FL patient with a positive 201Tl-S at diagnosis is treated by irradiation, the treatment response can be reliably ascertained by only performing a 201Tl-S.

Adult↗

Scrap metals industry perspective on radioactive materials.

With more than 80 reported/confirmed accidental melts worldwide since 1983 and still counting, potential contamination by radioactive materials remains as a major concern among recycled scrap and steel companies. Some of these events were catastrophic and have cost the industry millions of dollars in business and, at the same time, resulted in declining consumer confidence. It is also known that more events with confirmed radioactive contamination have occurred that involve mining of old steel slag and skull dumps. Consequently, the steel industry has since undergone massive changes that incurred unprecedented expenses through the installation of radiation monitoring systems in hopes of preventing another accidental melt. Despite such extraordinary efforts, accidental melts continue to occur and plague the industry. One recent reported/confirmed event occurred in the Republic of China in 2004, causing the usual lengthy shutdown for expensive decontamination efforts before the steel mill could resume operations. With this perspective in mind, the metal industry has a long-standing opposition to the release of radioactive materials of any kind to commerce for fear of contamination and the potential consequences.

Decision Making↗

Cancer in children of nuclear industry employees: report on children aged under 25 years from nuclear industry family study.

OBJECTIVE: To determine whether children of men and women occupationally exposed to ionising radiation are at increased risk of developing leukaemia or other cancers before their 25th birthday. DESIGN: Cohort study of children of nuclear industry employees. SETTING: Nuclear establishments operated by the Atomic Energy Authority, Atomic Weapons Establishment, and British Nuclear Fuels. SUBJECTS: 39 557 children of male employees and 8883 children of female employees. MAIN OUTCOME MEASURES: Cancer incidence in offspring reported by parents. Employment and radiation monitoring data (including annual external dose) supplied by the nuclear authorities. RESULTS: 111 cancers were reported, of which 28 were leukaemia. The estimated standardised incidence ratios for children of male and female employees who were born in 1965 or later were 98 (95% confidence interval 73 to 129) and 96 (50 to 168) for all malignancies and 109 (61 to 180) and 95 (20 to 277) for leukaemia. The leukaemia rate in children whose fathers had accumulated a preconceptual dose of >/=100 mSv was 5.8 times that in children conceived before their fathers' employment in the nuclear industry (95% confidence interval 1.3 to 24.8) but this was based on only three exposed cases. Two of these cases were included in the west Cumbrian ("Gardner") case-control study. No significant trends were found between increasing dose and leukaemia. CONCLUSIONS: Cancer in young people is rare, and our results are based on small numbers of events. Overall, the findings suggest that the incidence of cancer and leukaemia among children of nuclear industry employees is similar to that in the general population. The possibility that exposure of fathers to relatively high doses of ionising radiation before their child's conception might be related to an increased risk of leukaemia in their offspring could not be disproved, but this result was based on only three cases, two of which have been previously reported. High conceptual doses are rare, and even if the occupational association were causal, the number of leukaemias involved would be small; in this study of over 46 000 children, fewer than three leukaemias could potentially be attributed to such an exposure.

Adolescent↗

Comet assay in genetic ecotoxicology: a review.

The Comet assay, also called the single cell gel electrophoresis (SCGE) assay or microgel electrophoresis (MGE) assay, primarily measures DNA strand breakage in single cells. Since the protocol was published by Singh et al. [1988], its use has increased in different topic areas: clinical applications, human monitoring, radiation biology, genetic toxicology, and genetic ecotoxicology. This study is a review of the investigations that have involved the alkaline version of the Comet assay in genetic ecotoxicology. It focuses mainly on the type of organisms (plants, worms, molluscs, fish, amphibians, and mammalians) but also on the type of cells that have been used for ecotoxicological studies. In the 23 papers published since 1993 and presented here, the original test procedure may have been slightly modified according to the cell type. In vitro and in vivo experiments as well as in situ studies have been carried out in various environments (water, soil, and air). Although the Comet assay is able to detect genotoxic effects of chemical and physical agents, only chemical substances and environmental complex mixtures will be considered in this review.

Amphibians↗

MIRD pamphlet no. 16: Techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates.

This report describes recommended techniques for radiopharmaceutical biodistribution data acquisition and analysis in human subjects to estimate radiation absorbed dose using the Medical Internal Radiation Dose (MIRD) schema. The document has been prepared in a format to address two audiences: individuals with a primary interest in designing clinical trials who are not experts in dosimetry and individuals with extensive experience with dosimetry-based protocols and calculational methodology. For the first group, the general concepts involved in biodistribution data acquisition are presented, with guidance provided for the number of measurements (data points) required. For those with expertise in dosimetry, highlighted sections, examples and appendices have been included to provide calculational details, as well as references, for the techniques involved. This document is intended also to serve as a guide for the investigator in choosing the appropriate methodologies when acquiring and preparing product data for review by national regulatory agencies. The emphasis is on planar imaging techniques commonly available in most nuclear medicine departments and laboratories. The measurement of the biodistribution of radiopharmaceuticals is an important aspect in calculating absorbed dose from internally deposited radionuclides. Three phases are presented: data collection, data analysis and data processing. In the first phase, data collection, the identification of source regions, the determination of their appropriate temporal sampling and the acquisition of data are discussed. In the second phase, quantitative measurement techniques involving imaging by planar scintillation camera, SPECT and PET for the calculation of activity in source regions as a function of time are discussed. In addition, nonimaging measurement techniques, including external radiation monitoring, tissue-sample counting (blood and biopsy) and excreta counting are also considered. The third phase, data processing, involves curve-fitting techniques to integrate the source time-activity curves (determining the area under these curves). For some applications, compartmental modeling procedures may be used. Last, appendices are included that provide a table of symbols and definitions, a checklist for study protocol design, example formats for quantitative imaging protocols, temporal sampling error analysis techniques and selected calculational examples. The utilization of the presented approach should aid in the standardization of protocol design for collecting kinetic data and in the calculation of absorbed dose estimates.

Humans↗

Development and characterization of a DNA solar dosimeter.

In this paper, we report the development and characterization of a solar ultraviolet (UV) dosimetry system that can be used as a film badge for radiation monitoring. DNA molecules are coated on a thin nylon membrane as a UV dosimeter. The membrane is sealed in a polyethylene filter envelope with silica gel to keep the humidity low. After exposure to UV or solar light, induced DNA damage is measured by an immunochemical reaction. The intensity of color developed during the immunological reaction can be correlated linearly with the irradiated UV dose delivered by an Oriel solar simulator within a limited dose range. We observe no effects of temperature on the level of damage induction. The membrane is proficient for measuring DNA damage for more than 21 days when stored at either 37 or 4 degrees C. The induced damage remains stable on the membrane for at least 22 days at both 37 and 4 degrees C. In addition to these indoor experiments, we report measurements of solar UV dose in outdoor experiments.

DNA↗

Energy response of CaSO4:Dy teflon TLD disk dosimeters to photons and electrons.

The photon energy response of CaSO4:Dy teflon disk dosimeters used widely in radiation dosimetry is computed using the energy absorption coefficient values for calcium, sulfur, oxygen, and carbon taken from J. H. Hubbell's tables. For fluorine, the energy absorption coefficients were obtained from the values given by F. H. Attix for CaF2 and Ca. The energy response of the radiation-monitoring disk for the range of 10 keV to 10 MeV, relative to air, is computed and plotted. The response is maximum between 20 and 30 keV and then gradually falls to a constant at 200 keV to 10 MeV. This computed response for different energies is compared with the experimental TL response of the dosimeter. The electron energy response of these TLD disks is computed using the stopping-power values for the different component elements. The electron stopping power for sulfur and calcium from 10 keV to 10 MeV is computed using the Bethe-Bloch formula. Those for oxygen and carbon are taken from the tables given by M. J. Berger and S. M. Seltzer. For fluorine, the values are computed from those for Li and LiF given in the same tables. This calculated response is compared with the experimental beta response of the TL dosimeter.

Calcium Sulfate↗

Radiation safety implications of 131I treatment in a patient with Grave's disease undergoing home hemodialysis.

The radiation safety implications following the administration of 131I for the treatment of Grave's disease to a patient undergoing home-based renal dialysis was investigated. External dose-rate measurements from the patient revealed a peak value at around day 2, post administration. The effective half-life was determined as 6.5 d. From day 3, the clearance of 131I was observed to be fairly constant and equated to 2.7% per day or 5.4% per dialysis session. From this the biological half-life was determined as 15 d. Radiation monitoring of the dialysis unit, disposables, and bed linen found no detectable contamination. For the purpose of useful protection, at a distance of 1 m from the patient, the average dose rate over the effective treatment duration was determined to be 8 microSv h(-1) and at 2 m distance, 2.6 microSv h(-1). Thus, in order to keep below a level of dose constraint of 3 mSv the total allowable time spent at 1 m would be 375 h or 15 h per day. To comply with a 1-mSv constraint, the average daily exposure allowable at 1 m would be 5 h per day. Neither of these time limits would be difficult to achieve for the majority of situations with fairly modest behavioral constraints. Initial discharge concentration rates into the waste water system are estimated at 200 MBq m(-3) and therefore might need to be considered depending upon the regulatory environment.

Female↗

Comment: a biological guide for electromagnetic safety: the stress response.

Questions of safety of electromagnetic (EM) fields should be based on relevant biological properties, i.e., specific cellular reactions to potentially harmful stimuli. The stress response is a well documented protective reaction of plant and animal cells to a variety of environmental threats, and it is stimulated by both extremely low frequency (ELF) and radio frequency (RF) EM fields. It involves activation of DNA to initiate synthesis of stress proteins. Thermal and non-thermal stimuli affect different segments of DNA and utilize different biochemical pathways. However, both ELF and RF stimulate the same non-thermal pathway. Since the same biochemical reactions are stimulated in different frequency ranges with very different specific absorption rates (SARs), SAR level is not a valid basis for safety standards. Studies of EM field interactions with DNA and with model systems provide insight into a plausible mechanism that can be effective in ELF and RF ranges.

Electromagnetic Fields↗

Apartment electrical wiring: a cause of extremely low frequency magnetic field exposure in residential areas.

Extremely low frequency (ELF) magnetic fields (MFs) were measured at 696 points in a room of a Japanese apartment building. The building had 124 rooms with layouts and wiring identical to those of the studied room. ELF-MFs exceeded 0.4 microT in 24% of the living space, and the maximum value, 1.8 microT, was detected at floor level. Analysis of the MF distribution revealed that 60 Hz 100 V electrical wiring for room lights within the floor and ceiling had been laid out in large rectangles, equivalent to 1 turn coils. Further plotting of the vertical components every 0.01 m on the floor indicated that the depth of the cable was 0.23 m. Further studies should be conducted in order to confirm that the building investigated in this pilot study is typical of Japanese apartment buildings in terms of ELF-MFs.

Body Burden↗

Survey of residential 50 Hz EMF exposure from transformer stations.

In Hungary it is typical that 10/04 kV transformer stations are being installed in multistory residential and office buildings. Magnetic fields (MFs) up to several tens of microT have been measured in apartments close to transformers. The aim of the present study was to provide systematic assessment of MF exposure of residents living above transformer stations. Out of 41 addresses provided by the electricity supplier, current load of 21 transformers and MF in 21 apartments was measured. Spot MFs at 1 m height and time weighted average 24 h MF exposure at bed height was measured. All-day personal MF exposure was measured at waist and HOME exposure was calculated. BED exposure was measured at bed height. Participants kept a time-activity diary. The time-weighted average 24 h MF exposure (3.03 microT) exceeded the usual residential exposure (<0.2 microT). The mean HOME and BED personal exposure above transformers was 0.825 and 1.033 microT, respectively. Our study provides exposure assessment of a cohort with a wider exposure range, compared to power-line epidemiological studies.

Body Burden↗

Experimental determination of whole body average specific absorption rate (SAR) of mice exposed to 200-400 MHz CW.

A maximum of six live mice, mouse cadavers, prolate spheroids molded from muscle-equivalent tissue, or saline-filled culture flasks, were exposed to continuous wave radiation in a TEM cell at frequencies between 200 and 400 MHz. Whole-body average specific absorption rate (SAR) was determined from power meter measurements of incident, reflected, and transmitted powers. The SARs for both live mice and cadavers were approximately twice that for the prolate spheroid models, and when housed in Plexiglas restraining cages, about 2 1/2 times greater. An error multiplying factor is identified, that quantitatively expresses how SAR data obtained by the three-power-meter method becomes progressively more noisy as the irradiation frequency is lowered or as the TEM cell cross section is increased.

Animals↗

Dosimetry of portable image intensifiers in pacemaker insertions.

With the increased utilization of portable image intensifiers for pacemaker insertions, an investigation of the radiation hazards to operative personnel was undertaken. The personnel were tested first utilizing a Rando phantom and later during actual pacemaker insertions. Studies of medical personnel show the critical organs to be the thyroid (approximately 15mR per procedure) and the lens of the eye (approximately 13mR per procedure). While the MPD/week was not exceeded, the radiation dosage was substantial and could increase under operating conditions other than those measured. Recommendations to insure safer operation of this equipment are presented.

Fluoroscopy↗