Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Determination of central aortic systolic and pulse pressure from the radial artery pressure waveform.

OBJECTIVE: Measurements of central aortic systolic and pulse pressure, either gauged directly or estimated indirectly, have been shown to be superior to brachial pressure in outcome studies. While the radial pressure convolution method has proved to satisfy the criteria for 'substantial equivalence' to measure central pressure non-invasively, this study sought simpler methods to generate central systolic and pulse pressure directly from the radial artery waveform. METHODS: Two sets of data were used, in which radial artery pressure waves were measured by applanation tonometry and ascending aortic pressure was generated by the SphygmoCor process. Different approaches were applied to each dataset: firstly, using the time period from wave foot to systolic peak in central arteries; secondly, through identifying the pressure surge from the reflected wave in the radial artery; and thirdly from extrapolation and calibration of carotid systolic pressure when mean and diastolic pressure considered to be equal with radial values. RESULTS: Both datasets showed good correspondence between the central systolic and pulse pressure obtained with each of the three approaches and respective pressures generated by SphygmoCor process; all were within AAMI SP10 criteria and grade A for BSH criteria. CONCLUSION: All three approaches gave results similar substantially equivalent to those obtained with the SphygmoCor system for aortic, systolic and pulse pressure. Hence, simple inspection of the radial waveform has the potential to improve the estimation of aortic systolic and pulse pressure.

Aorta↗

Possible sources of discrepancy between sphygmomanometer cuff pressure and blood pressure quantified in a collapsible-tube analogue.

This paper examines the assumption that the audible events detected as Korotkov sounds in sphygmomanometry occur when blood pressure equals arm-cuff pressure. Several effects that contribute to discrepancy between these pressures are quantified using an idealised arm-and-cuff system consisting of a thick-walled collapsible tube subject to external compression along a central part of its length. The effects studied are (1) transverse pressure difference, resulting from tissues sustaining a part of the external compression through (a) circumferential bending stiffness and (b) longitudinal curvature of the tensed localised neck at the site of initial collapse, (2) longitudinal pressure difference between upstream pressure and pressure at the collapse point due to both (a) viscous and (b) inertial pressure drop. These effects are found to compensate partially for each other; the pressure within the vessel at the collapse point is less than the cuff pressure, but is also less than the blood pressure at the upstream end of the cuff. All four of the contributing terms increase proportionally to the flow-rate raised to a power greater than one, except the viscous pressure drop. Owing to a progressive shortening of the collapsed neck as flow-rate increases, the viscous term is almost independent of the flow-rate. The overall discrepancy displays less flow-rate dependency and is smaller than some of the terms which contribute to it. This means that considerable accuracy is needed if measurements of the effects are to be used to correct the raw data on cuff pressure at the time of Korotkov sound emission so as to obtain an improved estimate of the blood pressure.

Auscultation↗

Effect of plasma colloid osmotic pressure on intraocular pressure during haemodialysis.

BACKGROUND: In a previous case report, it was shown that an increase in plasma colloid osmotic pressure induced by the removal of fluid during haemodialysis was instrumental in decreasing intraocular pressure. The relation between changes in intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight before and after haemodialysis is evaluated. METHODS: Intraocular pressure, plasma osmolarity, plasma colloid osmotic pressure, and body weight were evaluated before and after haemodialysis in 36 patients. RESULTS: Intraocular pressure and plasma osmolarity both decreased significantly after haemodialysis (p < 0.0001). Plasma colloid osmotic pressure increased significantly after haemodialysis (p < 0.0001). Body weight decreased significantly because of the removal of fluid during haemodialysis (p < 0.0001). No significant correlation was found between the change in intraocular pressure and that in plasma osmolarity (r = -0.206, p = 0.2297), whereas the change in intraocular pressure was correlated with the change in plasma colloid osmotic pressure (r = -0.510, p = 0.0012) and the change in body weight (r = 0.534, p = 0.0006). A significant correlation was found between the change in plasma colloid osmotic pressure and that in body weight (r = -0.756, p < 0.0001). CONCLUSION: The change in intraocular pressure was inversely correlated with the increase in plasma colloid osmotic pressure caused by the removal of fluid during haemodialysis.

Adult↗

Pressure relieving support surfaces (PRESSURE) trial: cost effectiveness analysis.

OBJECTIVE: To assess the cost effectiveness of alternating pressure mattresses compared with alternating pressure overlays for the prevention of pressure ulcers in patients admitted to hospital. DESIGN: Cost effectiveness analysis carried out alongside the pressure relieving support surfaces (PRESSURE) trial; a multicentre UK based pragmatic randomised controlled trial. SETTING: 11 hospitals in six UK NHS trusts. PARTICIPANTS: Intention to treat population comprising 1971 participants. MAIN OUTCOME MEASURES: Kaplan Meier estimates of restricted mean time to development of pressure ulcers and total costs for treatment in hospital. RESULTS: Alternating pressure mattresses were associated with lower overall costs (283.6 pounds sterling per patient on average, 95% confidence interval--377.59 pounds sterling to 976.79 pounds sterling) mainly due to reduced length of stay in hospital, and greater benefits (a delay in time to ulceration of 10.64 days on average,--24.40 to 3.09). The differences in health benefits and total costs for hospital stay between alternating pressure mattresses and alternating pressure overlays were not statistically significant; however, a cost effectiveness acceptability curve indicated that on average alternating pressure mattresses compared with alternating pressure overlays were associated with an 80% probability of being cost saving. CONCLUSION: Alternating pressure mattresses for the prevention of pressure ulcers are more likely to be cost effective and are more acceptable to patients than alternating pressure overlays.

Adult↗

Intracranial volume--pressure relationships during experimental brain compression in primates. 2. Effect of induced changes in systemic arterial pressure and cerebral blood flow.

In eight anaesthetized, ventilated adult baboons, the intracranial volume-pressure response was examined at differing levels of raised intracranial pressure during induced changes in systemic arterial pressure and cerebral blood flow. The volume-pressure response is defined as the change in ventricular fluid pressure caused by a volume addition of 0·05 ml to the lateral ventricle. At normal intracranial pressure, the volume-pressure response was unchanged by alterations in systemic arterial pressure and cerebral blood flow. At raised intracranial pressure, however, systemic arterial hypertension rendered the intracranial contents more sensitive to the effects of an addition to the ventricular volume as shown by an increased volume-pressure response. When intracranial pressure was increased, there was a significant linear correlation between the volume-pressure response and both arterial pressure and cerebral blood flow. The clinical implication of this phenomenon is that arterial hypertension in patients with increased intracranial pressure is likely to have a deleterious effect by increasing brain tightness.

Animals↗

[Characteristics of blood pressure regulating endocrinological factors in elderly essential hypertensives].

Plasma renin activity (PRA) was lower in elderly normotensive subjects and essential hypertensives (EHT), and a significant negative correlation was found between PRA and age in both groups. In EHT, the proportion of the low renin group to total EHT increased with aging. There was a significantly positive correlation between plasma norepinephrine (PNE) and age in NT, but not in EHT. The mean value of PNE in young subjects was significantly higher in EHT than in NT, but not in the middle-aged and elderly groups, suggesting the important role of PNE in young EHT. Power spectral analysis revealed a significant reduction of both sympathetic and parasympathetic activity with aging in NT and EHT, indicating much caution may be required if sympathetic nerve activity is evaluated only by PNE levels in elderly EHT. The expanded plasma volume was another characteristic in elderly EHT, and suppressed activity of renal kallikrein-kinin, prostaglandin and dopamine may be involved with its mechanisms. Regarding insulin sensitivity in elderly EHT, it was shown that 1) the reduction of insulin sensitivity plays some role in age related acceleration of hypertension and glucose intolerance, 2) selective insulin resistance with respect to glucose metabolism already exists at lower ages in EHT, and 3) both Na retention and pressor system activation via insulin action might be a cause of blood pressure elevation in EHT.

Adult↗

Blood pressure and intracranial pressure-volume dynamics in severe head injury: relationship with cerebral blood flow.

Increased brain tissue stiffness following severe traumatic brain injury is an important factor in the development of raised intracranial pressure (ICP). However, the mechanisms involved in brain tissue stiffness are not well understood, particularly the effect of changes in systemic blood pressure. Thus, controversy exists as to the optimum management of blood pressure in severe head injury, and diverging treatment strategies have been proposed. In the present study, the effect of induced alterations in blood pressure on ICP and brain stiffness as indicated by the pressure-volume index (PVI) was studied during 58 tests of autoregulation of cerebral blood flow in 47 comatose head-injured patients. In patients with intact autoregulation mechanisms, lowering the blood pressure caused a steep increase in ICP (from 20 +/- 3 to 30 +/- 2 mm Hg, mean +/- standard error of the mean), while raising blood pressure did not change the ICP. When autoregulation was defective, ICP varied directly with blood pressure. Accordingly, with intact autoregulation, a weak positive correlation between PVI and cerebral perfusion pressure was found; however, with defective autoregulation, the PVI was inversely related to cerebral perfusion pressure. The various blood pressure manipulations did not significantly alter the cerebral metabolic rate of oxygen, irrespective of the status of autoregulation. It is concluded that the changes in ICP can be explained by changes in cerebral blood volume due to cerebral vasoconstriction or dilatation, while the changes in PVI can be largely attributed to alterations in transmural pressure, which may or may not be attenuated by cerebral arteriolar vasoconstriction, depending on the autoregulatory status. The data indicate that a decline in blood pressure should be avoided in head-injured patients, even when baseline blood pressure is high. On the other hand, induced hypertension did not consistently reduce ICP in patients with intact autoregulation and should only be attempted after thorough assessment of the cerebrovascular status and under careful monitoring of its effects.

Blood Pressure↗

Temperature effects on surface pressure-induced changes in rat skin perfusion: implications in pressure ulcer development.

The effect of varying local skin temperature on surface pressure-induced changes in skin perfusion and deformation was determined in hairless fuzzy rats (13.5+/-3 mo, 474+/-25 g). Skin surface pressure was applied by a computer-controlled plunger with corresponding skin deformation measured by a linear variable differential transformer while a laser Doppler flowmeter measured skin perfusion. In Protocol I, skin surface perfusion was measured without heating (control, T=28 degrees C), with heating (T=36 degrees C), for control (probe just touching skin, 3.7 mmHg), and at two different skin surface pressures, 18 mmHg and 73 mmHg. Heating caused perfusion to increase at control and 18 mmHg pressure, but not at 73 mmHg. In Protocol II, skin perfusion was measured with and without heating as in Protocol I, but this time skin surface pressure was increased from 3.7 to 62 mmHg in increments of 3.7 mmHg. For unheated skin, perfusion increased as skin surface pressure increased from 3.7 to 18 mmHg. Further increases in surface pressure caused a decrease in perfusion until zero perfusion was reached for pressures over 55 mmHg. Heating increased skin perfusion for surface pressures from 3.7 to 18 mmHg, but not for pressures greater than 18 mmHg. After the release of surface pressure, the reactive hyperemia peak of perfusion increased with heating. In Protocol III, where skin deformation (creep and relaxation) was measured during the application of 3.7 and 18 mmHg, heating caused the tissue to be stiffer, allowing less deformation. It was found that for surface pressures below 18 mmHg, increasing skin temperature significantly increased skin perfusion and tissue stiffness. The clinical significance of these findings may have relevance in evaluating temperature and pressure effects on skin blood flow and deformation as well as the efficacy of using temperature as a therapeutic modality in the treatment of pressure ulcers.

Analysis of Variance↗

[Relation of mass screening blood pressure to usual 24-hour working day blood pressure variation and left ventricular hypertrophy].

Fifty-three regularly employed hypertensive men (HT group) aged 38 to 68 years, whose blood pressure measured at a health evaluation clinic was systolic blood pressure (SBP) greater than or equal to 160 mmHg and/or diastolic pressure (DBP) greater than or equal to 95, and 21 age-matched normal controls (NC group), whose SBP was less than 140 and DBP was less than 90 had their blood pressure monitored over 24 hours during a usual working day. Age and clinical pressure were 53.1 +/- 7.1 years (mean +/- SD) and 147 +/- 18/97 +/- 10 mmHg (SBP/DBP) in the HT group, and 52.7 +/- 8.9 and 117 +/- 8/78 +/- 7 in the NC group. In the HT group, blood pressure during work (146/96 mmHg) was similar to clinical blood pressure, while blood pressure at home (135/89 mmHg) was considerably lower than clinic measured values. In contrast, blood pressure variabilities in the NC group during non-sleep hours were less, and clinical measurement was lower than that at home (122/80 mmHg), and during work (126/82 mmHg). For those examined by echocardiogram (46 in HT and 21 in NC), end-diastolic left ventricular wall thickness (LVT), and left ventricular mass index (LVMI) correlated most strongly with pressure during work by partial correlation analysis with age as a covariant (LVT:: SBP: r = 0.47, DBP: r = 0.53 both p less than 0.001, and LVMI:: SBP: r = 0.29, DBP: r = 0.25 both p less than 0.25). Clinical blood pressure as well as blood pressure at home and during sleep correlated significantly with LVT. These findings suggest that the blood pressure measurements obtained at a mass screening clinic, although infrequent, have important implications in relation to cardiac organ damage and for providing an estimate of blood pressure during work for hypertensives.

Adult↗

Reduction of variceal pressure by propranolol: comparison of the effects on portal pressure and azygos blood flow in patients with cirrhosis.

This study investigated the correlation between changes in hepatic hemodynamics and esophageal variceal pressure--measured with a noninvasive, pressure-sensitive endoscopic gauge--in 37 portal-hypertensive cirrhotic patients receiving propranolol (0.15 mg/kg, intravenously; n = 21) or placebo (n = 16) under strict double-blind conditions. Placebo administration had no effect on hepatic venous pressure gradient, azygos blood flow or variceal pressure. Propranolol caused a significant reduction in hepatic venous pressure gradient (from 19.6 +/- 1 to 17.3 +/- 1 mm Hg, p < 0.001), azygos blood flow (from 0.61 +/- 0.06 to 0.39 +/- 0.03 L/min, p < 0.001) and variceal pressure (from 13.1 +/- 0.9 to 10.2 +/- 0.9 mm Hg, p < 0.001). In eight patients (propranolol nonresponders) hepatic venous pressure gradient was not modified or decreased by less than 10% after propranolol (mean change, -4.1 +/- 1.6%). However, we found no significant differences between propranolol responders and nonresponders with regard to the decrease in variceal pressure (3.3 +/- 0.7 vs. 2.3 +/- 1.4 mm Hg) and azygos blood flow (0.23 +/- 0.07 vs. 0.21 +/- 0.07 L/min). As expected, in most propranolol responders (11 of 13), reduction in hepatic venous pressure gradient was accompanied by a similar response in variceal pressure (> 10% decrease). However, among propranolol nonresponders, in terms of reduction in hepatic venous pressure gradient, four out of eight patients had decreases greater than 10% in variceal pressure. The results of this study confirm that reduction in hepatic venous pressure gradient by propranolol is associated with a significant decrease in variceal pressure and azygos blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Ambulatory blood pressure monitoring: significance of blood pressure variability for progression of heart hypertrophy].

It is known that ambulatory blood-pressure monitoring gives a better prediction of target organ damage and prognosis than clinical blood pressure. Many studies have found a closer correlation for ambulatory blood pressure with left ventricular hypertrophy than clinical blood pressure. One question that is discussed controversely is whether the variability of blood pressure is also a determinant of target organ damage independent of the average level. In 52 patients with elevated casual blood pressure a 24-h ambulatory blood-pressure measurement (Space Labs 90202) was performed and left ventricular hypertrophy was evaluated by M-mode echocardiography. The following parameters of blood pressure variability were calculated from the profiles: the standard deviation of the mean value, the variation coefficient and the parameter of variability as proposed by Schächinger et al. Furthermore a Fourier analysis of the blood pressure data was performed to quantify blood pressure variability. We found no statistically significant correlation between blood pressure variability and left ventricular mass. However, systolic and diastolic blood pressure level showed a significant correlation with left ventricular hypertrophy (r = 0.45 and r = 0.49, p < 0.05). Thus, blood pressure variability as calculated from the ambulatory, non-invasive blood pressure monitoring is a poor predictor for secondary damage of the heart.

Adult↗

[Are home blood pressure measurements and 24-hour ambulatory recordings superior to office measurements? Comparison of 3 blood pressure recording methods in a study of cilazapril versus atenolol].

Self-assessment of blood pressure and ambulatory blood pressure monitoring (ABPM) are being more widely used in the diagnosis and therapy of hypertension, in addition to office blood pressure measurement. The present multicenter double-blind study compared cilazapril 2.5 to 5 mg (n = 26) to atenolol 50 to 100 mg (n = 27) over a period course of eight weeks. Office blood pressures in the morning before medication, ABPM over 24 h and self assessment of the blood pressure in the morning and evening were taken. The aim of the study was to find out if the results of ABPM and self assessment of blood pressure are similar when compared to office blood pressure measurement. After four weeks of therapy both cilazapril and atenolol achieved a significant and comparable reduction of blood pressure, which did not change significantly afterwards. Both medications showed a comparable blood pressure control over 24 h. with a once-a-day regimen. The comparison of the three techniques of blood pressure measurement demonstrates that ABPM results in significantly lower average daily values than office blood pressure measurement and that the self-assessed blood pressure values in most cases lie in-between. Although the diastolic ambulatory daily values were on the average 9 mmHg lower than the corresponding office values, it was not possible for an individual patient to accurately predict the ambulatory value obtained by to his office blood pressure value. Similar results were found for the values according to self assessment of blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Implications for clinical monitoring of intra-arterial blood pressure based on the frequency content of worst-case pressure waveforms.

There is no consensus regarding the minimum acceptable frequency response for a system intended for routine monitoring of invasive blood pressure in the operating rooms or intensive care units. Part of the problem stems from the diverse criteria used to validate faithful reproduction of the pressure waveform and waveform parameters. Another part of the problem is related to the site of pressure measurement: some anatomic sites have waveforms that are more difficult to reproduce than others. The most often quoted criteria, around which many clinical blood pressure monitoring systems have been constructed, are based on reproduction of all details of the pressure waveform from the most demanding anatomic sites. However, the routine clinical setting is primarily concerned with obtaining accurate values for systolic and diastolic blood pressures as recorded from peripheral arterial sites. This study was designed to obtain worst-case, in the sense of most difficult to measure, blood pressure waveforms from the femoral artery and the left ventricle using a canine model. The purpose of worst-case analysis was to create pressure waveforms that were at both extremes of frequency content, i.e., a rapidly beating heart with extraordinary contractility and a more slowly beating heart with little contractility. The premise of this type of analysis is that all naturally occurring pressure waveforms within a very broad physiologic range would fall within these extremes; therefore, the ability to measure the extreme waveforms would imply the ability to measure all those in between. Worst-case waveforms chosen from among 360 pressure waveforms were analyzed to determine the minimum frequency content of each waveform that would be required for faithful reproduction of systolic and diastolic pressures and the dP/dt. The criterion for faithful reproduction was chosen to be +/- 5% or 1 mmHg, whichever is greater. Data from the worst-case canine study, with supporting data collected intraoperatively from three patients, demonstrate that systolic and diastolic pressures can be obtained from a peripheral measurement site within 5%, requiring only two harmonics in conjunction with an appropriately low-pass-filtered catheter manometer system. Left ventricular pressure waveforms require five harmonics to reproduce the systolic and diastolic pressures within 5% or 1.0 mmHg, whichever is greater. Determination of the maximum dP/dt within +/- 5% from the worst-case peripheral and left ventricular waveforms required 20 and 22 harmonics, respectively.

Animals↗

Representativeness of peripheral blood pressure values: the pulsatile component of blood pressure in hypertension.

Whereas mean arterial pressure remains practically unmodified along the arterial tree, pulse pressure increases markedly from central to peripheral arteries, principally due to an increase in systolic blood pressure and a small lowering of diastolic blood pressure. This hemodynamic pattern, due to the progressive increase in arterial stiffness and to the summation between the incident and the backward pressure wave along the arterial tree, has several implications, in that: i) the pulse pressure amplification increases with the effective length of the arterial tree (and therefore with the body height of subjects), but decreases with aging, due to a significant age-induced increase in aortic wave reflections and pulse pressure, ii) the magnitude of the pulse pressure amplification is strongly influenced by the status of the autonomic nervous system, so that carotid pulse pressure decreases more than brachial pulse pressure following sympathetic stimulation using lower body negative pressure, and iii) the pulse pressure amplification may be restored following administration of pharmacological agents as converting enzyme inhibitors and calcium entry-blockers but not dihydralazine. These particularities of pressure wave transmission may have fundamental consequences for: the diagnosis of hypertension, whether in humans or in animal; the evaluation of cardiac afterload and the effectiveness of antihypertensive agents; and finally, the interpretation of cardiovascular epidemiology. Indeed increased brachial pulse pressure is known to be an independent cardiovascular risk factor, particularly for myocardial infarction, but not for cerebrovascular complications.

Angiotensin-Converting Enzyme Inhibitors↗

The influence of airway pressure changes on intracranial pressure (ICP) and the blood flow velocity in the middle cerebral artery (VMCA).

OBJECTIVE: Due to the exponential shape of the intracranial volume-pressure relation, simple measurement of epidural, parenchymal or intraventricular intracranial pressure (ICP) in traumatic brain injury (TBI) often fails to early recognize patients with a fulminant development of intracranial hypertension even during recently available methods of tissue PO2 and microdialysis measurements. One approach to this problem could be repetitive intracranial volume provocations to evaluate a trend of the intracranial elastance. Several previously published methods use invasive volume challenge through access to the cerebrospinal fluid (CSF). This pilot study describes changes in intracranial pressure due to variations of airway pressure with BIPAP ventilation maneuvers. PATIENTS AND METHODS: Ten patients with severe TBI were enrolled and completed the study. The inclusion was based on radiologic signs due to TBI in the first CT-scan and the clinical indication for insertion of an ICP monitoring device. Patients with elevated ICP above 20 mm Hg were excluded. The epidural ICP response together with haemodynamic parameters in relation to defined airway pressure changes (delta PAW) was detected. The influence of the duration of delta PAW was evaluated additionally. Data of central venous pressure (CVP), ICP, mean arterial pressure (MAP), cerebral perfusion pressure (CPP), airway pressure (PAW) and blood flow velocity of the middle cerebral artery (VMCA) were analyzed on the basis of differences between the maximum (inspiration) and minimum PAW values (expiration). RESULTS: Elevations of PAW in the range of 20 to 35 cm H2O resulted in changes of the ICPmean from 4.1 to 6.0 mm Hg (r = 0.9, p < 0.05). A correlation was estimated for the changes of systolic arterial pressure (Part) and CPPmean due to PAW variations which ranged between 4.5 and 11.6 mm Hg (r = 0.99, p < 0.05). Concerning the transcranial doppler measurements the data of changes of the blood flow velocity of the middle cerebral artery (VMCA) revealed a positive correlation to PAW with a r = 0.99, p < 0.05. CONCLUSIONS: Elevation of the venous outflow resistance and a transient increase in cardiac output have to be considered as mechanisms for transduction of transthoracic pressure changes to intracranial pressure variations. We conclude, that trends of changes in elastance can be derived from intermittent airway pressure variations. This can be useful in easy and on line dynamic monitoring of ICP in traumatic brain injury.

Air Pressure↗

Importance of valves and lymphangion contractions in determining pressure gradients in isolated lymphatics exposed to elevations in outflow pressure.

Lymphatic pressures were measured at several locations along an isolated lymphatic system exposed to elevations in outflow pressure. The objective of this study was to determine the contributions of lymphangion contractions and valve function to the observed pressure gradients. In each experiment, five bovine mesenteric lymphatic vessels (each with four to nine lymphangions) were joined in series by t-pieces connected to pressure transducers. The vessels were placed in an organ bath with input provided by a reservoir filled with Krebs solution. With a constant inflow pressure of 4 cm H2O, outflow pressures were elevated in 2- or 5-cm H2O increments. Except for inflow and outflow pressures which were fixed, the pressures measured at four other locations along the system were pulsatile due to lymphatic contractions. The mean pressures increased as outflow pressures were raised. While mean pressures were highest at the outflow end, estimates of the net pressure generated by each segment suggested that all segments, including those at the most upstream locations, increased their contractile activity. In addition, diastolic pressure gradients formed across the system. These did not appear to be due to valve failure (endurance limit of valves was 168 +/- 32 cm H2O) but rather, appeared to relate to the progressive inability of lymphangions to empty which, for a given lymphangion, began to occur at a mean outflow pressure of 9.8 +/- 1.1 cm H2O.

Animals↗

Office blood pressures in supine, sitting, and standing positions: correlation with ambulatory blood pressures.

The variability of casual (office) blood pressure according to position at the time of measurement was investigated in 168 untreated patients with a history of mild to moderate essential hypertension. Two measurements were made in the supine, sitting, and standing positions on each of 2 consecutive days, and 24-hour ambulatory blood pressure monitoring was performed. The mean supine, sitting, and standing blood pressures were 146 +/- 15/91 +/- 7, 144 +/- 15/96 +/- 8, and 149 +/- 17/103 +/- 7 mm Hg, respectively. Diastolic blood pressures were significantly different from each other (P less than 0.0001). Supine and sitting systolic blood pressures were not different, but they were different from standing blood pressure (P less than 0.0001). The mean of all three positions (overall blood pressure) was 146 +/- 15/96 +/- 7 mm Hg. Supine, sitting, standing, and overall diastolic blood pressure means were 90 mm Hg or more in 88, 133, 164, and 133 patients, respectively. The mean awake ambulatory and 24-hour ambulatory blood pressures were 143 +/- 16/95 +/- 7 and 138 +/- 16/92 +/- 8 mm Hg, respectively, and diastolic blood pressures were 90 mm Hg or more in 121 and 88 patients, respectively. The correlation of office blood pressure with ambulatory blood pressure varied according to office position and was 0.76 to 0.82 (P less than 0.0001) for systolic blood pressure and 0.60 to 0.69 (P less than 0.0001) for diastolic blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Dissociation of diastolic pressure-segment length and pressure-wall thickness relations during vasodilation in the conscious dog.

The effects of pharmacologic vasodilation and reductions in circumflex coronary artery pressure on the ventricular diastolic pressure-segment length and pressure-wall thickness relations were studied in nine conscious dogs equipped with an inflatable cuff on the proximal circumflex artery, a micromanometer in the left ventricle and four sets of piezoelectric crystals to measure wall thickness and endocardial segment length in the left circumflex and left anterior descending artery territories. Adenosine infusion into the circumflex coronary artery increased endocardial and transmural blood flow to that territory (measured by microspheres) by 436% and 487%, respectively (both p less than 0.05), and shifted the left circumflex artery territory pressure-wall thickness curve upward (p less than 0.05) without affecting the circumflex pressure-segment length, the left anterior descending artery territory pressure-segment length or pressure-wall thickness curves significantly; papaverine also shifted the circumflex region pressure-wall thickness curve upward (p less than 0.05). Both with and without vasodilation, moderate reductions in circumflex artery perfusion pressure did not affect the position of the ventricular pressure-wall thickness or the pressure-segment length curve (although during adenosine infusion endocardial blood flow decreased from 436% to approximately 100% of control values). More severe reductions in perfusion pressure (less than 45 mm Hg under control conditions and less than 30 mm Hg during adenosine infusion) decreased coronary blood flow below control values and caused a marked downward shift of the circumflex region pressure-segment length curve without affecting the position of the pressure-wall thickness curve.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine↗