Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Linear Energy Transfer”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Radiation-induced chromosome damage in astronauts' lymphocytes.

The increased number of manned space missions has made it important to estimate the biological risks encountered by astronauts. As they are exposed to cosmic rays, especially ions with high linear energy transfer (LET), it is necessary to estimate the doses they receive. The most sensitive biological dosimetry used is based on the quantification of radiation-induced chromosome damage to human lymphocytes. After the space missions ANTARES (1992) and ALTAIR (1993), we performed cytogenetic analysis of blood samples from seven astronauts who had spent from 2 weeks to 6 months in space. After 2 or 3 weeks, the X-ray equivalent dose was found to be below the cytogenetic detection level of 20 mGy. After 6 months, the biological dose greatly varied among the astronauts, from 95 to 455 mGy equivalent dose. These doses are in the same range as those estimated by physical dosimetry (90 mGy absorbed dose and 180 mSv equivalent dose). Some blood cells exhibited the same cytogenetic pattern as the 'rogue cells' occasionally observed in controls, but with a higher frequency. We suggest that rogue cells might result from irradiation with high-LET particles of cosmic origin. However, the responsibility of such cells for the long-term effects of cosmic irradiation remains unknown and must be investigated.

Astronauts↗

Rejoining of DNA double-strand breaks induced by accelerated nitrogen ions.

Rejoining of radiation-induced DNA double-strand breaks (dsb) was measured in cultured cells with pulsed-field gel electrophoresis after radiation doses in the range of 5-30 Gy. Human glioma, U-343MG and Chinese hamster, V79, cells were irradiated with either accelerated nitrogen ions of high linear energy transfer, LET approximately 125 keV/ microns, or photons from 60Co. The induction frequencies of dsb were similar for the two radiation qualities with a relative biological effectiveness, RBE, of 0.90 and 0.89 for the human and hamster cell lines respectively. The biphasic rejoining kinetics differed significantly between the two radiation qualities when studied in the human glioma cells. The difference was seen within the first hour after irradiation and after 6 h there were considerable differences in both the total amount of unrejoined dsb and the fraction of dsb rejoined during the slow phase. When rejoining was analysed 20-22 h after irradiation, the nitrogen ions gave 2.5-2.9 times more residual dsb than the gamma photons. The results for the hamster V79 cells were, up to 2h after irradiation, similar, but the difference between the two radiation qualities was less accentuated. In summary, similar initial yields of dsb after exposure of cells to high or low LET resulted in both radiation quality and cell type-dependent differences when the rejoining of these breaks were compared.

Animals↗

Measurement of the depth distribution of average LET and absorbed dose inside a water-filled phantom on board space station MIR.

The Atominstitute of the Austrian Universities developed the HTR-method for determination of absorbed dose and "averaged" linear energy transfer (LET) in mixed radiation fields. The method was applied with great success during several space missions (e.g. STS-60, STS-63, BION-10 and BION-11) and on space station MIR in the past 10 years. It utilises the changes of peak height ratios in LiF thermoluminescent glowcurves in dependence on the LET. Due to the small size of these dosemeters the HTR-method can be used also for measurements inside tissue equivalent phantoms. A water filled phantom with a diameter of 35 cm containing four channels where dosemeters can be exposed in different depths was developed by the Institute for Biomedical Problems. This opens the possibility to measure the depth distribution of the average LET and the dose equivalent simultaneously. During phase 1 dosemeters were exposed for 271 days (05.1997-02.1998) in 6 different depths inside the phantom, which was positioned in the commander cabin. In phase 2 dosemeters were exposed in 2 channels in 6 different depths for 102 days (05.1998-08.1998) in the board engineer cabin, following an exposure in different channels in 3 different depths for 199 days (08.1998- 02.1999) in the Modul KWANT 2.

Humans↗

Experimental and calculated LET distributions in the Cosmos-2044 biosatellite orbit.

During the flight of the Cosmos-2044 biosatellite, joint U.S.S.R.-U.S.A. investigations of different characteristics of cosmic radiation (CR) in the near-Earth environment were carried out. The U.S. dielectric track detectors CR-39 and Soviet BYa- and BR-type nuclear photo-emulsions were used as detectors. The present work shows some results of experimental measurements of linear energy transfer (LET) spectra of CR particles obtained with the use of these detectors, which were placed both inside and outside the satellite. The LET spectra measurement with plastic detectors is composed of two parts: the measurement of galactic cosmic rays (GCR) particles, and of short-range particles. The contributions of these components to the total LET distribution at various thicknesses of the shielding were analyzed and the results of these studies are presented. Calculated LET spectra in the Cosmos-2044 orbit were compared with experimental data. On the basis of experimental and calculated values of the LET spectra, absorbed and equivalent CR doses were calculated. In the shielding range of 1-1.5 g cm-2, outside the spacecraft, the photo-emulsions yielded 10.3 mrad d-1 and 27.5 mrem d-1 (LET > or = 2 MeV cm-1) while the CR-39 yielded averages of 1.43 mrad d-1 and 13.4 mrem d-1 (LET > or = 40 MeV cm-1). Inside the spacecraft (> or = 10 g cm-2) the photo-emulsions yielded 8.9 mrad d-1 and 14.5 mrem d-1.

Cosmic Radiation↗

Mechanisms for the biological effectiveness of high-LET radiations.

Radiations of high linear energy transfer (LET) have long been known to have greater biological effectiveness per unit dose than those of low LET, for a wide variety of biological effects. However, values of relative biological effectiveness depend considerably on the biological system and in some instances the values are clearly below unity. The differences between high- and low-LET radiations may be due to many factors, almost all of which are related to radiation track structure in one way or another, and some can in principle lead to qualitative as well as quantitative differences between the radiations. Explanations for LET-dependent differences in effectiveness are discussed over a variety of levels from the multicellular and cellular scale down to the DNA scale, with illustrations from radiobiological data. Information from well-defined slow light ions provide particularly useful analytic data, but practical issues extend also to neutrons and fast heavy ions, which may compound high- and low-LET features. It is suggested that effectiveness of the radiation is determined predominantly by the complex clustered damage that it produces in DNA, but that for high-LET radiations long-term effects are in some instances limited by single-track-survival probabilities of the traversed cells.

Animals↗

LET dependence of lethality of carbon ion irradiation to single tobacco cells.

PURPOSE: To determine the radiation sensitivity and relationship between linear energy transfer (LET) and relative biological effectiveness (RBE) in single plant cells irradiated with heavy ions. MATERIALS AND METHODS: Single cells were isolated from the tobacco BY-2 cell line and irradiated with carbon ions (78.6-309 keV microm(-1)) and gamma-rays (0.2 keV microm(-1)). Two weeks after irradiation, colonies with 16 cells or more derived from the irradiated cells were counted as survivors. The surviving fraction was fitted using the single-hit, multitarget theory. RESULTS: The doses needed to reduce the surviving fraction of the cells to 0.1 (D10) of gamma-rays and carbon ions were 47.2 and 10.5-12.6 Gy, respectively. The RBE based on the D10 peaked at an LET of 247 keV microm(-1). The inactivation cross-section of carbon ions reached a plateau of 11.3 microm2 at an LET of 247 keV microm(-1). CONCLUSIONS: The radiation sensitivity of single tobacco cells was much lower than that of mammalian cells, although the mean number of base pairs per chromosome in the two cell types was similar. The RBE peak based on the D10 of carbon ions in single tobacco cells occurred at a higher LET than it does in other organisms.

Carbon↗

Interphase death in human peripheral blood lymphocytes after moderate and high doses of low and high LET radiation: an electron microscopic approach.

Peripheral blood lymphocytes irradiated with low and moderate doses of low linear energy transfer (LET) gamma-rays are known to die by an apoptotic process. In the present study, the type of interphase death occuring after administration of moderate and high doses of low LET gamma-rays and high LET fast neutrons was investigated. Lymphocytes were irradiated in vitro with radiation doses of 5 and 20 gray (Gy) of both radiation qualities. They were cultured for 24 or 48 hours and the type of cell death induced was determined by electron microscopy. After neutron irradiation, a slight increase in the incidence of apoptosis from 5 to 20 Gy was found, whereas after gamma-irradiation, the incidence of apoptosis was lower at 20 Gy as compared to 5 Gy. However, unlike the other radiation doses, the 20 Gy dose of gamma-rays, besides apoptosis also induced oncosis (classical necrosis). According to our experiments, membranes are probably an important target for the induction of interphase death. It is suggested that a great amount of ionisations distributed all over the cell surface, as caused by high doses of gamma-rays, lead to a high influx of Ca++ which induces oncosis instead of apoptosis.

Cell Death↗

Dose protraction studies with low- and high-LET radiations on neoplastic cell transformation in vitro.

A major objective of our heavy-ion research is to understand the potential carcinogenic effects of cosmic rays and the mechanisms of radiation-induced cell transformation. During the past several years, we have studied the relative biological effectiveness of heavy ions with various atomic numbers and linear energy transfer on neoplastic cell transformation and the repair of transformation lesions induced by heavy ions in mammalian cells. All of these studies, however, were done with a high dose rate. For risk assessment, it is extremely important to have data on the low-dose-rate effect of heavy ions. Recently, with confluent cultures of the C3H10T1/2 cell line, we have initiated some studies on the low-dose-rate effect of low- and high-LET radiation on cell transformation. For low-LET photons, there was a decrease in cell killing and cell transformation frequency when cells were irradiated with fractionated doses and at low dose rate. Cultured mammalian cells can repair both subtransformation and potential transformation lesions induced by X rays. The kinetics of potential transformation damage repair is a slow one. No sparing effect, however, was found for high-LET radiation. There was an enhancement of cell transformation for low-dose-rate argon (400 MeV/u; 120 keV/micrometer) and iron particles (600 MeV/u; 200 keV/micrometer). The molecular mechanisms for the enhancement effect is unknown at present.

Animals↗

Incorporation of microdosimetric concepts into a biologically-based model of radiation carcinogenesis.

The generalised state-vector model of radiation carcinogenesis (SVM) simulates radiation induced biological effects by expressing the transition rates between the various initiation and promotion stages in terms of dose rate for low and high linear energy transfer (LET) particles. In the present work, the SVM has been reformulated to incorporate single track characteristics of particles with varying LET. Transition rates of the initiation phase were expressed as functions of LET by describing the complexity and clustering of DNA double strand breaks (DSBs) and its effect on repair kinetics, while the promotion phase was reformulated based on a multi-target single-hit hypothesis. Such an approach allows the consideration of hit frequencies and the variability of the specific energy and LET spectra of radon progeny alpha particles in bronchial target cells for different exposure conditions.

Alpha Particles↗

Radiation measurements aboard Spacelab 1.

The radiation environment inside Spacelab 1 was measured by a set of passive radiation detectors distributed throughout the volume inside the module, in the access tunnel, and outside on the pallet. Measurements of the low-LET (linear energy transfer) component obtained from the thermoluminescence detectors ranged from 102 to 190 millirads, yielding an average low-LET dose rate of 11.2 millirads per day inside the module, about twice the low-LET dose rate measured on previous flights of the space shuttle. Because of the higher inclination of the orbit (57 degrees versus 28.5 degrees for previous shuttle flights), substantial fluxes of highly ionizing HZE particles (high charge and energy galactic cosmic rays were observed, yielding an overall average mission dose-equivalent of about 150 millirems, more than three times higher than measured on previous shuttle missions.

Cosmic Radiation↗

Dosimetry and microdosimetry characteristics measured on board the MIR station during the 28th basic expedition.

Three types of detectors were used onboard the MIR station during the 28th base expeditions to characterise the radiation field: a linear energy transfer (LET) spectrometer was used to establish the LET spectrum between 7 and 700 keV/micrometers corresponding mostly to secondary charged particles; a set of thermoluminescent detectors was used to characterise the low LET component of the onboard radiation field; and Si-diodes were installed to determine the contribution to the exposure due to fast neutrons. It was found out that the LET spectrum from secondary particles between 7 and 700 KeV/micrometers does not depend on the external radiator; the average quality factors for the region mentioned are about 6.0 with ICRP 26 quality factors and about 6.8 with ICRP 60 quality factors. Both differential and integral LET spectra are presented for some typical cases, not only for particle number but also for the dose characteristics like dose and dose equivalent. The spectra obtained also permitted us to calculate the total doses and dose equivalents due to secondary particles with the LET values between 7 and 700 keV/micrometers. It was found out that these quantities are higher for the case of detectors placed in the less shielded area, both for the LET spectrometer (high LET part) as well as for TLDs measuring the low LET component. Total dosimetric characteristics obtained as a sum of both components mentioned are a little lower than previously reported.

Cosmic Radiation↗

Application of real-time radiation dosimetry using a new silicon LET sensor.

A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.

Calibration↗

Heavy ion irradiation inhibits in vitro angiogenesis even at sublethal dose.

Angiogenesis is essential for tumor growth and metastasis. Because endothelial cells are genetically stable, they rarely acquire resistance to anticancer modalities, and could, thus, be a suitable target for radiation therapy. Heavy ion radiation therapy has attracted attention as an effective modality for cancer therapy because of its highly lethal effects, but the effects of heavy ion irradiation on in vitro cell function associated with angiogenesis have not been reported. Our study found that in vitro angiogenesis was inhibited by high linear energy transfer carbon ion irradiation even at sublethal dose (0.1 Gy). ECV304 and HUVEC human umbilical vascular endothelial cells were irradiated with 290 MeV carbon ion beams of approximately 110 keV/ micro m or 4 MV X-ray of approximately 1 keV/ micro m. Their adhesiveness and migration to vitronectin or osteopontin were inhibited, and capillary-like tube structures in three-dimensional culture were destroyed after carbon ion irradiation concomitant with the inhibition of matrix metalloproteinase-2 activity, down-regulation of alphaVbeta3 integrin, which is one of the adhesion molecules, slight up-regulation of membrane type1- matrix metalloproteinase, and significant up-regulation of tissue inhibitor of metalloproteinase-2. On the other hand, sublethal X-ray irradiation promoted migration of endothelial cells, and the capillary-like tube structure in three-dimensional culture progressed even after 16 Gy irradiation. These results provide an implication that heavy ion beam therapy could be superior to conventional photon beam therapy in preventive effects on in vitro angiogenesis even at sublethal dose, and might inhibit angiogenesis in vivo.

Capillaries↗

High-LET radiation enhanced apoptosis but not necrosis regardless of p53 status.

PURPOSE: We analyzed the death pattern of human lung cancer cells harboring different p53 statuses after irradiation with different levels of linear energy transfer (LET). METHODS AND MATERIALS: We used three kinds of human lung cancer cell lines with identical genotypes, except for the p53 gene. These cells were exposed to X-rays or accelerated carbon-ion beams. The cellular sensitivities were determined by a colony-forming assay. The detection and quantification of cell death (apoptosis and necrosis) were evaluated and compared by acridine orange/ethidium bromide double staining for fluorescence microscopy. RESULTS: We found that (1) there was no significant difference in cellular sensitivity to LET radiation >70 KeV/microm, although wild-type p53 cell sensitivity to X-rays was higher than that of mutated p53 or p53-null cells; (2) low-LET radiation effectively induced apoptosis in wild-type p53 cells as compared with mutated p53 and p53-null cells; and (3) high-LET radiation induced p53-independent apoptosis. CONCLUSIONS: Our findings suggest that high-LET radiotherapy is expected to be a valid application for patients carrying mutated p53 cancer cells. We proposed that the elucidation of the p53-independent apoptosis-related genes might provide new insights into radiotherapy for cancer.

Apoptosis↗

Computer simulation of data on chromosome aberrations produced by X rays or alpha particles and detected by fluorescence in situ hybridization.

With fluorescence in situ hybridization (FISH), many different categories of chromosome aberrations can be recognized-dicentrics, translocations, rings and various complex aberrations such as insertions or three-way interchanges. Relative frequencies for the various aberration categories indicate mechanisms of radiation-induced damage and reflect radiation quality. Data obtained with FISH support a proximity version of the classic random breakage-and-reunion model for the formation of aberrations. A Monte Carlo computer implementation of the model, called the CAS (chromosome aberration simulator), is generalized here to high linear energy transfer (LET) and compared to published data for human cells irradiated with X rays or 238Pu alpha particles. For each kind of radiation, the CAS has two adjustable parameters: the number of interaction sites per cell nucleus and the number of reactive double-strand breaks (DSBs) per gray. Aberration frequencies for various painted chromosomes, of varying lengths, and for 11 different categories of simple or complex aberrations were simulated and compared to the data. The optimal number of interaction sites was found to be approximately 13 for X irradiation and approximately 25 for alpha-particle irradiation. The relative biological effectiveness (RBE) of alpha particles for the induction of reactive DSBs (which are a minority of all DSBs) was found to be approximately 4. The two-parameter CAS model adequately matches data for many different categories of aberrations. It can use data obtained with FISH for any one painting pattern to predict results for any other kind of painting pattern or whole-genome staining, and to estimate a suggested overall numerical damage indicator for chromosome aberration studies, the total misrejoining number.

Alpha Particles↗

[Analysis of death pattern in cancer cells by using different kinds of LET radiation].

We investigated the death pattern of cancer cells by using different kinds of linear energy transfer (LET) radiation. We used two human squamous cell carcinoma cell lines with an identical genotype except for the p53 gene. SAS/mp53 cells were established by transfection with the mp53 gene to SAS cells having functional p53 (wtp53). As the control, a neovector was transfected to the SAS cells (SAS/neo cells). Both types of cells were exposed to X-rays (1.5 KeV/micron) or accelerated C-beams (30-100 KeV/micron). The frequency of cell death (apoptosis and necrosis) was measured by acridine orange/ethidium bromide(AO/EB) double staining for fluorescence microscopy. We found that (1) low-LET radiation induced apoptosis only in SAS/neo cells; (2) high-LET radiation at an iso-survival dose induced apoptosis not but necrosis in SAS/neo cells at a higher frequency; (3) high-LET radiation induced p53-independent apoptosis even in SAS/mp53 cells. Our findings suggest that high-LET radiotherapy is expected to (1) have validity in its application to patients carrying mutated p53 cancer cells and (2) reduce injury to adjacent normal tissue for high-frequency-induced apoptosis without inflammatory response. We propose that elucidation of p53-independent apoptosis-related genes might provide new insights into radiotherapy for cancer.

Apoptosis↗

Clusters of DNA double-strand breaks induced by different doses of nitrogen ions for various LETs: experimental measurements and theoretical analyses.

The yields and clustering of DNA double-strand breaks (DSBs) were investigated in normal human skin fibroblasts exposed to gamma rays or to a wide range of doses of nitrogen ions with various linear energy transfers (LETs). Data obtained by pulsed-field gel electrophoresis on the dose and LET dependence of DNA fragmentation were analyzed with the randomly located clusters (RLC) formalism. The formalism considers stochastic clustering of DSBs along a chromosome due to chromatin structure, particle track structure, and multitrack action. The relative biological effectiveness (RBE) for the total DSB yield did not depend strongly on LET, but particles with higher LET produced higher fractions of small DNA fragments, corresponding in the formalism to an increase in the average number of DSBs per DSB cluster. The results are consistent with the idea that DSB clustering along chromosomes is what leads to large RBEs of high-LET radiations for major biological end points. At a given dose, large fragments are less affected by the variability in LET than small fragments, suggesting that the two free ends in large fragments are often produced by two different tracks. The formalism successfully described an extra increase in small DNA fragments as dose increases and a related decrease in large fragments, mainly due to interlacing of DSB clusters produced along a chromosome by different tracks, since interlacing cuts larger DNA fragments into smaller ones.

Cell Line↗

A portable dose equivalent meter based on microdosimetry.

It is generally accepted that the physical basis of the relative biological effectiveness of different radiations is the difference in the spatial distribution of ionization along the charged particle tracks. Thus it is possible to measure physical quantities which may be related to biological damage, and use them to estimate the radiation protection quantity "dose equivalent". A prototype instrument utilizing a spherical proportional counter and microcomputer to make such measurements has been developed and tested. The detector is filled with gas at low pressure in order to simulate micrometer diameter volumes of tissue. Energy deposition in these small volumes is a stochastic quantity which depends on charged particle stopping power, path length through the site, energy loss straggling, and energy transport by secondary charged particles (delta rays). It has been suggested that this energy deposition distribution be used as a basis for defining radiation quality factor (mean Q). However, to the extent that the energy deposition in the site is proportional to the geometric chord length distribution, energy deposition can also be used to determine the linear energy transfer. The mean quality factor can then be calculated on the basis of the current definition. The prototype instrument uses two amplifiers, with gains of 50 and 1000, processing the pulses from a single detector in order to resolve the wide range of energy deposition events produced by neutron and gamma irradiation. Each amplifier is connected to a specially designed analog to digital converter and a 128 channel multichannel analyzer. A microcomputer controls the system and calculates dose and dose equivalent. Test results for a variety of accelerator produced neutron irradiations show that, from 0.1 to 15 MeV, system accuracy is +/- 0.5 for mean Q and +/- 15% for dose equivalent.

Cosmic Radiation↗