Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Computer Programs And Programming”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

VECTAN II: A computer program for the spatial analysis of the vectorcardiogram.

This paper presents the operation of a digital computer program, VECTAN II, for the spatial analysis of the vectorcardiogram (VCG). The program incorporates a unique waveform recognition algorithm based on the spatial vector length which has been shown to perform better than previous algorithms. The waveform analysis employed by the program considers the vectorcardiogram as a three dimensional entity rather than as scalar or planar representations. VECTAN II is designed chiefly to measure and quantify the VCG response of normal subjects to a controlled stress by analyzing one VCG complex every five seconds throughout a long experiment. The program has been used to analyzeom the NASA Johnson Space Center Cardiovascular Laboratory, from the pre- and postflight medical examinations of the Apollo 15, 16 and 17 crewmen, and from onboard Skylab experiments.

Aerospace Medicine↗

A computer program for an illness-death process with time-dependent covariates.

This paper presents a computer program for estimating transition probabilities between states in a stochastic model for an illness-death process which incorporates time-dependent covariates. Parameters are estimated by the method of maximum likelihood using the Newton-Raphson iterative procedure. The program provides the standard normal deviate statistics as well as the value of the maximum of the likelihood function which can be used on repeated applications to test hypotheses concerning coefficients associated with covariates. Although this program is demonstrated by using a model with two 'illness' states and two 'death' states, it is also suitable for analyzing data with models involving fewer states, such as the analysis of survival time with covariates assuming a proportional hazard model.

Computers↗

MASSFORM: a computer program for the assignment of elemental compositions to high resolution mass spectral data.

This paper describes a computer program which calculates all possible empirical formulas for each accurately measured mass in a high resolution mass spectrum. The program, MASSFORM, incorporates a novel mechanism for classifying the empirical formulas generated according to their empirical formula. This mechanism makes it possible to use a set of general empirical formulas to aid in the analysis of complex mixtures in much less time than most other such programs. The program is being used as an important aid to environmental studies.

Chemical Phenomena↗

A computer program for the study of synaptic transmission at the neuromuscular junction.

The study of synaptic biopotentials at the neuromuscular junction has proven to be an invaluable tool in understanding the pre- and post-synaptic mechanisms underlying chemical synaptic transmission and exploring the pathogenesis of neuromuscular disorders. Computer technology has become an important part of these experiments as it increases accuracy and automates the process, allowing more data to be collected and quantitatively analysed. This paper presents a computer program for IBM PC compatible computers capable of recording and analysing the spontaneously occurring miniature end-plate potentials (MEPPs), neurally evoked end-plate potentials (EPPs) and muscle fiber action potentials (APs). The program performs its basic analysis immediately following the sampling of biopotentials from a muscle fiber, thus providing the user with immediate feedback on the status of the experiment; 45 parameters of neuromuscular transmission are computed on-line and displayed on the monitor along with the signal-averaged waveforms. After a series of fibers has been recorded, the program will compile the data into summary tables. The program is designed to provide an experimenter with an easy-to-use, comprehensive method of performing electrophysiological measurements and analysis at the neuromuscular junction.

Action Potentials↗

BIGPROBE: a computer program that predicts the sequence of long oligonucleotide probes with high reliability.

We have written a computer program, BIGPROBE, which facilitates the design of long nucleic acid probes from the partial or complete amino acid sequence of a protein. BIGPROBE relies upon information on codon usage, intercodon dinucleotide frequency, and potential probe self-complementarity. We have examined the accuracy with which the program predicts coding sequences using sample human and rat genes and probe lengths of 30-60 nucleotides. Rat probe sequences selected by BIGPROBE using either codon usage or dinucleotide frequency data alone averaged 86-92% homology with the known exons of the corresponding gene sequences. Predictive accuracy with rat gene probes could be improved to 89-94%, depending upon probe length, by applying codon usage and dinucleotide frequency data in combination. Similar accuracy was achieved for human genes.

Amino Acid Sequence↗

A computer program for testing average partial association in three-way contingency tables (PARCAT).

PARCAT is a computer program which implements alternative tests for average partial association in three-way contingency tables within the framework of the product multiple hypergeometric probability model. Primary attention is directed at the relationship between two of the variables, controlling for the effects of a covariable. This approach is essentially a multivariate extension of the Cochran/Mantel-Haenszel test to sets of (s x r) tables. A set of scores such as uniform, ridits, or probits can be assigned to categories which are ordinally scaled. In particular, if ridit scores with midranks assigned for ties are utilized, this procedure is equivalent to a partial Kruskal-Wallis test when one variable is ordinally scaled, and is equivalent to a partial Spearman rank correlation test when both variables are ordinally scaled.

Age Factors↗

Computer programs for the radioactive microsphere technique. Determination of regional blood flows and other haemodynamic variables in different experimental circumstances.

Computer programs in FORTRAN IV have been designed to calculate regional blood flow values from injections of gamma radiation-emitting radioactive microspheres. The first program PRSO constitutes a file containing the names of organs, organ groups and systemic haemodynamic variables and data about the isotopes in use. The second program PRSI transfers the data of the particular experiment concerning protocol, systemic haemodynamic variables, organ weights, number of vials belonging to each organ and the radioactivity from each vial into a data file that is subsequently analyzed by the third program PRSII. One of 5 data conditions which later directs calculations in PRSII is determined by PRSI. PRSII deducts background radioactivity, decomposes the spectrum from the mixture of up to 6 nuclides using the "stripping' method, and corrects for isotope decay during the counting period. Depending upon the data condition, PRSII calculates one or more of the following variables: (i) cardiac output (CO); (ii) the distribution of CO; (iii) regional blood flow values and tissue vascular resistances; (iv) the distribution of blood flow within an arterial bed; (v) arteriovenous anastomotic blood flow; (vi) some specified systemic haemodynamic variables; and (vii) blood flow ratios. The systemic and regional haemodynamic data belonging to experiments are saved for later statistical analyses (e.g., mean, standard error of the variables, changes from the base line, comparison between two groups of experiments) by other programs. PRSO, PRSI and PRSII can be operated by investigators with little or no special training in computer use.

Animals↗

A computer program for the deconvolution of mass spectral peak abundance data from experiments using stable isotopes.

A computer program is described for deconvoluting the overlap which is often found in mass spectral peak abundance data from stable isotope experiments. Peak intensity data from calibration standards are corrected using parameters calculated from the analysis of separate external standard solutions of analytes and internal standard. If the calibration data are satisfactory, the same parameters and the slope and intercept values from the least squares analysis of the calibration data are used to correct and quantitate the mass spectral peak intensity data from the quality assurance and experimental samples. Reports and graphs appropriate to the process are produced. Applications are given for the analysis of plasma samples from stable isotope experiments with carprofen, cifenline, and midazolam.

Carbazoles↗

Development of a computer program, MDGP, for population pharmacokinetic analysis written using ANSI C language on wide platforms.

MDGP, a computer program for population pharmacokinetics, has been developed. This program is based on maximum likelihood estimation with poly-dimensional normal distribution errors, and variable metric methods, direction set methods, conjugate gradient methods and the polytope method are provided as minimizations of objective function. The source codes of MDGP are described using ANSI C language. MDGP is able to run on wide platforms equipped with an ANSI C compiler. Users can use algebraic, ordinary differential and Laplace-transformed equations as descriptions of a pharmacokinetic model. Partial differential equations for each model parameter are not needed. Comparison of the estimated parameters, the iteration counts until convergence and objective function value, using MDGP and NONMEM, revealed that the calculation performance of the two programs are comparable. The MDGP is thought to be useful for the analysis of various pharmacokinetic models, including population pharmacokinetic analysis.

Humans↗

SEQ-ED: an interactive computer program for editing, analysis and storage of long DNA sequences.

The rapidly growing body of sequenced DNA demands efficient computer programs for its analysis and storage. The program described in this paper, SEQ-ED, has been designed to handle a large number of DNA sequences up to 200 kilobases [kb] long stored in a sequence library. In order to minimize the required storage space, the sequences are stored in a compressed format using three binary digits per base. In the development of this program, special care has been given to make it easy to use for molecular biologists without any previous computer experience.

Algorithms↗

Development of a computer program for teaching periodontal diagnosis based on clinical epidemiological principles.

Multimedia teaching tools in dental education are still rare. This paper describes the development of an inexpensive yet powerful computer program for instruction in the principles of clinical epidemiology. The application was developed in the context of periodontal diagnostic methodologies at the third year D.D.S. level. Principles of probabilistic thinking are invoked as the student is guided from the application of raw research data to the derivation of likelihood ratios and how they affect clinical decision making. A questionnaire was used to evaluate student satisfaction with the program and the responses indicated good acceptance of the concepts presented in the program and an interest in further computer-aided instruction.

Computer-Assisted Instruction↗

A computer program for the analysis of dental models.

This paper presents the details and logic of a Fortran computer program which carries out routine clinical analysis of dental models resulting from impressions of the teeth and related structures, which are subsequently cast in plaster of Paris. The program is primarily intended for use by the orthodontist who is engaged in research or clinical practice, and is useful in studies related to changes in the dentition as a result of orthodontic treatment.

Computers↗

A computer program for estimating thresholds by means of Wetherill's Up-Down Transformed Response Rule (UDTR).

A Fortran IV computer program is presented which allows for automatic estimation of thresholds on an S-shaped psychometric curve by means of Wetherill's Up-Down Transformed Response Rule (UDTR). The efficiency and asymptotic properties of these rules are discussed and illustrated. The main program is in the form of a keyboard portable tutorial which calls the main decision-making subroutine. The subroutine can be detached from the tutorial. Only a single call with seven parameters is required to reach the subroutine. The program is particularly useful in forced-choice procedures.

Auditory Threshold↗

[Optimizing ruminant feed rations from the physiological aspect with FURAT, a personal computer program].

Health disorders caused by feeding are a common problem in cattle keeping. For this reason the personal computer program, FURAT, was developed for the calculation and optimization of ruminant feed rations with respect to physiological aspects. With this program, weighed feed rations selected from the feedstuff on the standard list or from a self-drawn up feedstuff list can be tested for their content of various nutrients and compared with the requirements of the animals to be fed. Subsequently in an optimization program using the same feedstuff rations can be worked out for various performance categories ensuring the best possible feeding from the health aspect. With a free choice within a feed range and taking into account the physiological limits of the rumen (maximum compound intake, minimum raw fiber amount in the dry matter, minimum structure in the raw fiber, maximum raw fat in the dry matter) the ration is calculated to achieve a balanced protein-energy ratio. One of the two main nutrients--protein or energy--must amount exactly to the target value in the ration, and the other has to be as close as possible to its target value. From among up to 12 different feedstuff the computer will choose the optimal ration which can be printed with a precise indication of all parameters. The rations worked out for the various performance categories are stored and, at the end of the program, are printed in short form in a letter addressed to the farmer that also lists necessary mineral supplements.

Animal Feed↗

Evaluation of a Bayesian regression-analysis computer program using non-steady-state phenytoin concentrations.

The predictive performance of a Bayesian regression-analysis computer program that uses non-steady-state phenytoin data was evaluated. Forty patients receiving phenytoin or phenytoin sodium who had two or more non-steady-state serum concentrations were selected for study. Additional serum concentrations and dosing data were collected as they became available, but no effort was made to control the number or timing of serum concentration determinations. Patients were categorized into four groups for evaluation of the effect of potential bioavailability problems and length of dosing history (time over which serum concentration-time data were collected) on the ability to predict subsequent phenytoin concentrations. Population parameters for phenytoin maximum rate of elimination (Vmax), apparent Michaelis-Menten constant (Km), volume of distribution (V), and bioavailability (F) were obtained from the literature. Predictions based on serum phenytoin concentrations and dosing histories (information intervals) of 5 or 10 days were compared with predictions based on naive (population-based) estimates using prediction-error analysis. In each patient group, the use of either 5-day or 10-day information intervals resulted in a significant increase in precision and a significant reduction in bias compared with naive estimates. For the group of patients who initially had two or more serum concentrations within the first five days of monitoring, predictions showed a marked increase in bias and a decrease in precision as the time interval from the last measured concentration to the time of prediction increased.(ABSTRACT TRUNCATED AT 250 WORDS)

Bayes Theorem↗

[Comparison of 3 ECG computer programs with interpretation by physicians].

Three ECG computer programs-Hewlett Packard analog program (HP), Telemed analog program (T) and Marquette 12 SL digital program (MAC)-were evaluated and their accuracy of ECG reading compared with the reading of 4 experienced interpreters on 140 ECGs of patients with various clinical abnormalities. Major disagreement with effect on patient management, and minor disagreement were defined at a joint session with a senior (consensus). The computers identified all normal ECGs correctly (sensitivity 100%). The percentage of major agreements (full agreements and minor disagreements) between consensus and computer was 79% for HP, 90% for T and 93% for MAC. The number of disagreements varied widely between readers and in relation to the different computers. Major problems for the computers were the interpretation of rhythm disturbances and the diagnosis of myocardial infarction, T-wave changes and ventricular hypertrophy: major diagnoses missed by the readers were first degree AV block, QT prolongation, and myocardial infarction. Although there was a considerable difference of accuracy between the 3 computer systems, all of them are sufficiently accurate to be useful to most clinicians. However, every ECG should be over-read by a physician, particularly if a clinical decision is based on the ECG diagnosis.

Adolescent↗

MoWeD, a computer program to rapidly deconvolute low resolution electrospray liquid chromatography/mass spectrometry runs to determine component molecular weights.

A computer program is described that can rapidly process low-resolution electrospray liquid chromatography/mass spectrometry (LC/MS) for peptides and proteins and assign molecular weights for observed components. The program first analyzes individual scans using a deconvolution algorithm similar to that previously described by Zhang and Marshall. Results for the entire run are then sorted by mass and those values found in adjacent scans are grouped together. The list of found components can also be compared to a user defined list of target molecular weight values making it easy to compare the results from different analyses. The program also has the capability to process a rolling average of scans that improves the performance when analyzing high molecular weight components. Other program features facilitate closer examination of selected spectra or regions of the chromatogram to check the MoWeD mass assignments. The utility of the program was demonstrated by the analysis of LC/MS data derived from a complex mixture of proteins derived from a bacterial whole cell lysate that had previously been analyzed manually. The MoWeD analysis was 30 times faster and provided a more comprehensive list of the components present.

Bacillus anthracis↗