Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “COSMIC RADIATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Cosmic rays and dosimetry at aviation altitudes.

Recent concerns regarding the effects of the cosmic radiation field at aircraft altitudes on aircrew have resulted in a renewed interest in detailed measurements of the neutral and charged particle components in the atmosphere. CR-39 nuclear track detectors have been employed on a number of subsonic and supersonic aircraft to measure charge spectra and LET spectra at aircraft altitudes. These detectors are ideal for long term exposures required for these studies and their passive nature makes them suitable for an environment where interference with flight instrumentation could be a problem. We report here on measurements and analysis of short range tracks which were produced by high LET particles generated mainly by neutron interactions at aviation altitudes. In order to test the overall validity of the technique measurements were also carried out at the CERN-CEC field which simulates the radiation field at aviation altitudes and good agreement was found with dose values obtained using mainly heavy ion calibration.

Aircraft↗

Model analysis of Space Shuttle dosimetry data.

An extensive model analysis of plastic track detector measurements of high-LET particles on the Space Shuttle has been performed. Three shuttle flights: STS-51F (low-altitude, high-inclination), STS-51J (high-altitude, low-inclination), and STS-61C (low-altitude, low-inclination) are considered. The model includes contributions from trapped protons and galactic cosmic radiation, as well as target secondary particles. Target secondaries, expected to be of importance in thickly shielded space environments, are found to be a significant component of the measured LET (linear energy transfer) spectra.

Cosmic Radiation↗

Chromosome aberration dosimetry in cosmonauts after single or multiple space flights.

BACKGROUND AND AIMS: Cosmic radiation is one of the main hazards for manned space exploration. Uncertainty in radiation risk estimates for crews of long-term missions are very high, and direct biological measurements are necessary. We measured chromosomal aberrations in peripheral blood lymphocytes from 33 cosmonauts involved in space missions during the past 11 years. METHODS: Blood lymphocytes from the cosmonauts were stimulated to grow in vitro and were harvested at their first mitosis. Slides were either stained with Giemsa stain for dicentrics analysis, or painted with whole-chromosome DNA probes for translocation analysis (FISH). RESULTS: A statistically significant increase in the yield of chromosomal aberrations was measured following long-term space missions in lymphocytes from cosmonauts at their first flight. No significant changes in aberration frequencies were observed for short-term taxi flights. The increase in long-term missions was consistent with the values calculated from physical dosimetry data. However, for cosmonauts involved in two or more space flights, the yield of interchromosomal exchanges was not related to the total duration of space sojourn or integral absorbed dose. Indeed, the yield of aberrations at the end of the last mission was generally in the range of background frequencies measured before the first mission. CONCLUSIONS: Chromosome aberration dosimetry can detect radiation damage during space flight, and biological measurements support the current risk estimates for space radiation exposure. However, for cosmonauts involved in multiple space missions the frequency of chromosomal aberrations is lower than expected, suggesting that the effects of repeated space flights on this particular endpoint are not simply additive. Changes in the immune system in microgravity and/or adaptive response to space radiation may explain the apparent increase in radioresistance after multiple space flights.

Astronauts↗

Results of time-resolved radiation exposure measurements made during U.S. Shuttle missions with a tissue equivalent proportional counter.

Time-resolved radiation exposure measurements inside the crew compartment have been made during recent Shuttle missions with the USAF Radiation Monitoring Equipment-III (RME-III), a portable four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. The missions had orbital inclinations ranging from 28.5 degrees to 57 degrees, and altitudes from 200-600 km. Dose equivalent rates ranged from 40-5300 micro Sv/dy. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicle. Measurements indicate that medium- and high-LET particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Iso-dose rate contours have been developed from measurements made during the STS-28 mission. The drift rate of the South Atlantic Anomaly (SAA) is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and Galactic Cosmic Radiation (GCR) dose for the STS-28 mission were significantly lower than the measured values.

Cosmic Radiation↗

Inactivation of individual Bacillus subtilis spores in dependence on their distance to single cosmic heavy ions.

For radiobiological experiments in space, designed to investigate biological effects of the heavy ions of the cosmic radiation field, a mandatory requirement is the possibility to spatially correlate the observed biological response of individual test organisms to the passage of single heavy ions. Among several undertakings towards this goal, the BIOSTACK experiments in the Apollo missions achieved the highest precision and therefore the most detailed information on this question. Spores of Bacillus subtilis as a highly radiation resistant and microscopically small test organism yielded these quantitative results. This paper will focus on experimental and procedural details, which must be included for an interpretation and a discussion of these findings in comparison to control experiments with accelerated heavy ions.

Bacillus subtilis↗

The Biostack experiment on Apollo 16.

The object of the Biostack experiment is to study the biological effects of high ZE particles of cosmic radiation in order to obtain information on the mechanism of these particles in biological matter. For this purpose individual local evaluation methods have been developed which allow one to identify each biologically effective particle and to correlate the individual hitting particle with the biological effect produced. The Biostack experimental package contains a series of monolayers of selected biological objects (Bacillus subtilis spores, Arabidopsis thaliana seeds, Vicia faba radiculae, Artemia salina eggs) with each layer sandwiched between several different cosmic ion track detectors (nuclear emulsions, cellulose nitrate, polycarbonate). By this arrangement a variety of biological effects due to a single penetrating particle can be analysed. Influence on cellular and tissue development, nuclear damages, and mutation induction are the main investigated effects. These space flight findings will be completed by results of balloon flight and accelerator experiments.

Animals↗

Radiation environment on the Mir orbital station during solar minimum.

The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 microGy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm-2 of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm-2 of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these detectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15-1000 keV/micrometer, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 microSv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members.

Atlantic Ocean↗

Experimental and calculated LET distributions in the Cosmos-2044 biosatellite orbit.

During the flight of the Cosmos-2044 biosatellite, joint U.S.S.R.-U.S.A. investigations of different characteristics of cosmic radiation (CR) in the near-Earth environment were carried out. The U.S. dielectric track detectors CR-39 and Soviet BYa- and BR-type nuclear photo-emulsions were used as detectors. The present work shows some results of experimental measurements of linear energy transfer (LET) spectra of CR particles obtained with the use of these detectors, which were placed both inside and outside the satellite. The LET spectra measurement with plastic detectors is composed of two parts: the measurement of galactic cosmic rays (GCR) particles, and of short-range particles. The contributions of these components to the total LET distribution at various thicknesses of the shielding were analyzed and the results of these studies are presented. Calculated LET spectra in the Cosmos-2044 orbit were compared with experimental data. On the basis of experimental and calculated values of the LET spectra, absorbed and equivalent CR doses were calculated. In the shielding range of 1-1.5 g cm-2, outside the spacecraft, the photo-emulsions yielded 10.3 mrad d-1 and 27.5 mrem d-1 (LET > or = 2 MeV cm-1) while the CR-39 yielded averages of 1.43 mrad d-1 and 13.4 mrem d-1 (LET > or = 40 MeV cm-1). Inside the spacecraft (> or = 10 g cm-2) the photo-emulsions yielded 8.9 mrad d-1 and 14.5 mrem d-1.

Cosmic Radiation↗

Embryogenesis and organogenesis of Carausius morosus under spaceflight conditions.

The influence of cosmic radiation and/or microgravity on insect development was studied during the 7 day German Spacelab Mission D1. Eggs of Carausius morosus of five stages differing in sensitivity to radiation and in capacity to regeneration were allowed to continue their development in the BIORACK 22 degrees C incubator, either at microgravity conditions or on the 1 g reference centrifuge. Using the Biostack concept--eggs in monolayers were sandwiched between visual track detectors--and the 1 g reference centrifuge, we were able to separate radiation effects from microgravity effects and also from combined effects of these two factors in space. After retrieval, hatching rates, growth kinetics and anomaly frequencies were determined in the different test samples. The early stages of development turned out to be highly sensitive to single hits of cosmic ray particles as well as to the temporary exposure to microgravity during their development. In some cases, the combined action of radiation and microgravity even amplified the effects exerted by the single parameters of space. Hits by single HZE particles caused early effects, such as body anomalies, as well as late effects, such as retarded growth after hatching. Microgravity exposure lead to a reduced hatching rate. A synergistic action of HZE particle hits and microgravity was established in the unexpectedly high frequency of anomal larvae. However, it cannot be excluded, that cosmic background radiation or low LET HZE particles are also causally involved in damage observed in the microgravity samples.

Abnormalities, Radiation-Induced↗

Mortality from cancer and other causes among airline cabin attendants in Germany, 1960-1997.

Airline cabin attendants are exposed to several potential occupational hazards, including cosmic radiation. Little is known about the mortality pattern and cancer risk of these persons. The authors conducted a historical cohort study among cabin attendants who had been employed by two German airlines in 1953 or later. Mortality follow-up was completed through December 31, 1997. The authors computed standardized mortality ratios (SMRs) for specific causes of death using German population rates. The effect of duration of employment was evaluated with Poisson regression. The cohort included 16,014 women and 4,537 men (approximately 250,000 person-years of follow-up). Among women, the total number of deaths (n = 141) was lower than expected (SMR = 0.79, 95% confidence interval (CI): 0.67, 0.94). The SMR for all cancers (n = 44) was 0.79 (95% CI: 0.54, 1.17), and the SMR for breast cancer (n = 19) was 1.28 (95% CI: 0.72, 2.20). The SMR did not increase with duration of employment. Among men, 170 deaths were observed (SMR = 1.10, 95% CI: 0.94, 1.28). The SMR for all cancers (n = 21) was 0.71 (95% CI: 0.41, 1.18). The authors found a high number of deaths from acquired immunodeficiency syndrome (SMR = 40; 95% CI: 28.9, 55.8) and from aircraft accidents among the men. In this cohort, ionizing radiation probably contributed less to the small excess in breast cancer mortality than reproductive risk factors. Occupational causes seem not to contribute strongly to the mortality of airline cabin attendants.

Accidents, Aviation↗

Effects of trapped proton flux anisotropy on dose rates in low Earth orbit.

Trapped protons in the South Atlantic Anomaly (SAA) have a rather narrow pitch angle distribution and exhibit east-west anisotropy. In low Earth orbits, the E-W effect results in different amounts of radiation dose received by different sections of the spacecraft. This effect is best studied on missions in which the spacecraft flies in a fixed orientation. The magnitude of the effect depends on the particle energy and altitude through the SAA. In this paper, we describe a clear example of this effect from measurements of radiation dose rates and linear energy transfer spectra made on Space Shuttle flight STS-94 (28.5 degree inclination x 296 km altitude). The ratio of dose rates from the two directions at this location in the mid-deck was 2.7. As expected from model calculations, the spectra from the two directions are different, that is the ratio is energy dependent. The data can be used to distinguish the anisotropy models. The flight carried an active tissue equivalent proportional counter (TEPC), and passive thermoluminscent detectors (TLDs), and two types of nuclear emulsions. Using nuclear emulsions, charged particles and secondary neutron energy spectra were measured. The combined galactic cosmic radiation+trapped charged particle lineal energy spectra measured by the TEPC and the linear energy transfer spectrum measured by nuclear emulsions are in good agreement. The charged particle absorbed dose rates varied from 112 to 175 microGy/day, and dose equivalent rates from 264.3 to 413 microSv/day. Neutrons in the 1-10 MeV contributed a dose rate of 3.7 microGy/day and dose equivalent rate of 30.8 microSv/day, respectively.

Anisotropy↗

Measurement of the energy spectrum of cosmic-ray induced neutrons aboard an ER-2 high-altitude airplane.

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the atmospheric ionizing radiation (AIR) project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to >10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was eight times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56-201 g cm-2 atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Aerospace Medicine↗

Implications for space radiation environment models from CREAM & CREDO measurements over half a solar cycle.

Flight data obtained between 1990 and 1997 from the Cosmic Radiation Environment Monitors CREAM & CREDO carried on UoSAT-3, Space Shuttle, STRV-1a (Space Technology Research Vehicle) and APEX (Advanced Photovoltaic and Electronics Experiment Spacecraft) provide coverage over half a solar cycle. The modulation of cosmic rays and evolution of the South Atlantic Anomaly are observed, the former comprising a factor of three increase at high latitudes and the latter a general increase accompanied by a north-westward drift. Comparison of particle fluxes and linear energy transfer (LET) spectra is made with improved environment & radiation transport calculations which account for shield distributions and secondary particles. While there is an encouraging convergence between predictions and observations, significant improvements are still required, particularly in the treatment of locally produced secondary particles. Solar-particle events during this time period have LET spectra significantly below the October 1989 event which has been proposed as a worst case model.

Atlantic Ocean↗

Galactic cosmic rays and cell-hit frequencies outside the magnetosphere.

An evaluation of the exposure of space travelers to galactic cosmic radiation outside the earth's magnetosphere is made by calculating fluences of high-energy primary and secondary particles with various charges traversing a sphere of area 100 microns2. Calculations relating to two shielding configurations are presented: the center of a spherical aluminum shell of thickness 1 g/cm2, and the center of a 4 g/cm2 thick aluminum spherical shell within which there is a 30 g/cm2 diameter spherical water phantom with the point of interest 5 g/cm2 from the surface. The area of 100 microns2 was chosen to simulate the nucleus of a cell in the body. The frequencies as a function of charge component in both shielding configurations reflects the odd-even disparity of the incident particle abundances. For a three-year mission, 33% of the cells in the more heavily shielded configuration would be hit by at least one particle with Z greater than 10. Six percent would be hit by at least two such particles. This emphasizes the importance of studying single high-Z particle effects both on cells which might be "at risk" for cancer induction and on critical neural cells or networks which might be vulnerable to inactivation by heavy charged particle tracks. Synergistic effects with the more numerous high-energy protons and helium ions cannot be ruled out. In terms of more conventional radiation risk assessment, the dose equivalent decreased by a factor of 2.85 from free space to that in the more heavily shielded configuration. Roughly half of this was due to the decrease in energy deposition (absorbed dose) and half to the decrease in biological effectiveness (quality factor).

Aluminum↗

Survey of the vestibulum, and behavior of Xenopus laevis larvae developed during a 7-days space flight.

Aquatic animals have almost no body weight related proprioception for spatial orientation. Xenopus larvae, like fish, maintain their attitude in water by continuous correction with their fin(s). For these reasons a special performance of the equilibrium system compared to terrestrial animals is necessary. Evidently fish therefore have more compact (dense) otoliths; Xenopus larvae have less dense otolith (membranes) similar to land vertebrates; but their sacculus-otoliths are vertically positioned, which also may lead to a higher g-sensitivity. For plausibility reasons gravity should influence the embryonic development of gravity receptors. Yet, evaluations of photographs taken from the surface of cut deep-frozen objects by incident light show no aberration of the shape of the whole vestibulum and of the shape, density, size and position of the otolith membrane in larvae developed under near-zero g (NEXPA-BW-STATEX in D-1-Mission). The further evaluation of the "weightless-larvae" revealed a probably not yet described statolith-like formation in the dorsal wall of the vestibulum. In the weightless larvae this formation outnumbers, also qualitatively, strongly the l-g controls. An extra result is the lack of striking effects of cosmic radiation on the embryonic development of the flown Xenopus eggs. The swimming behavior of the larvae which was observed about one hour after landing of the Space Shuttle showed a typical anomaly (loop swimming), which is known from larvae developed on the clinostat or from fish flown aboard Apollo capsules.

Animals↗

The measurement using passive dosemeters of the neutron component of aircraft crew dose.

The cosmic radiation field at aviation altitudes can be measured with simple passive detectors. The non-neutron component may be measured by means of thermoluminescence dosimetry or other techniques, and the neutron component may be measured using poly allyl diglycol carbonate (PADC) dosemeters as described in this paper. Effective dose from neutron radiation becomes the larger component for altitudes above about 10 km, in general. The dominance is more pronounced for higher latitudes. The neutron energies range up to the maximum of the incident protons, that is many GeV. However the majority of the dose is contributed by neutrons of a few hundred MeV and less, with two maxima in the fluence spectrum, one between 1 and 10 MeV and the other between 50 and 150 MeV. We have used PADC dosemeters, electrochemically etched, to estimate the neutron component of effective dose. Up to 50 dosemeters are used in a single measurement to obtain an estimate of sufficient precision for total neutron effective doses of 50 microSv and less. The neutron fluence response characteristics of the dosemeter have been measured up to 70 MeV. These are extrapolated up to 180 MeV. This extrapolation is validated, partially, by a comparison of measured and predicted readings in the CERN reference field. From the dosemeter readings for exposure on board aircraft, neutron fluence may be estimated assuming an isotropic radiation field and the estimated neutron fluence spectrum. The neutron fluence may then be converted to effective dose using published values of conversion coefficients with the same assumptions of isotropy and known fluence spectrum. For the measurement results reported here, the calculated spectrum for the CERN concrete shielded field is used.

Aerospace Medicine↗

What we can learn from heavy ion therapy for radioprotection in space.

A major problem in manned space flight is the impact of cosmic radiation, especially that of heavy charged particles since they have an elevated biological efficiency (RBE). The RBE estimation determines the potential exposure for man. It is one of the limiting factors for space flight and should be known very precisely. The same is true for heavy-ion tumor therapy where beams of carbon ions are used to treat deep-seated tumors. There, RBE values determine the dose distribution and are estimated using the Local Effect Model (LEM). The clinical results confirm the correctness of LEM and suggest to use the same theoretical approach to assess the impact of cosmic rays.

Carbon↗

Particle trajectories in seeds of Lactuca sativa and chromosome aberrations after exposure to cosmic heavy ions on Cosmos Biosatellites 8 and 9.

The potentially specific importance of the heavy ions of the galactic cosmic radiation for radiation protection in manned spaceflight continues to stimulate in situ, i.e., spaceflight experiments to investigate their radiobiological properties. Chromosome aberrations as an expression of a direct assault on the genome are of particular interest in view of cancerogenesis being the primary radiation risk for man in space. In such investigations the establishment of the geometrical correlation between heavy ions' trajectories and the location of radiation sensitive biological substructures is an essential task. The overall qualitative and quantitative precision achieved for the identification of particle trajectories in the order of approximately 10 micrometers as well as the contributing sources of uncertainties are discussed. We describe how this was achieved for seeds of Lactuca sativa as biological test organisms, whose location and orientation had to be derived from contact photographies displaying their outlines and those of the holder plates only. The incidence of chromosome aberrations in cells exposed during the COSMOS 1887 (Biosatellite 8) and the COSMOS 2044 (Biosatellite 9) mission was determined for seeds hit by cosmic heavy ions. In those seeds the incidence of both single and multiple chromosome aberrations was enhanced. The results of the Biosatellite 9 experiment, however, are confounded by spaceflight effects unrelated to the passage of heavy ions.

Chromosome Aberrations↗