[Comparative studies on the radioactivity of bone cements containing x-ray contrast media and of the contrast media].

Various PMMA bone cements containing zirconium oxide (ZrO2) as an X-ray contrast medium and zirconium oxides of several manufacturers were tested for their radioactivity by means of a gamma spectrometer. All the bone cements tested (Implast, Palacos R, and Sulfix-6) showed a certain degree of radioactivity. The radiation source in the bone cement is the added zirconium oxide, which is polluted by radioactive elements. The examination of various zirconium oxides showed some high radioactive emissions. The risk of radiation-induced cancer seems to be small, because the cements are normally implanted in humans older than 60 years. In view of the fact that these X-ray contrast media remain in the body for decades as components of the bone cement, the radioactive zirconium oxides should be replaced by high-purity radiation-free zirconium oxide or barium sulphate as soon as possible.

Bone Cements↗

Kinetic study of citric acid influence on calcium phosphate bone cements as water-reducing agent.

Most of the research performed on calcium phosphate bone cements (CPBCs) has dealt with the improvement of bone cement formulations for new, demanding bone-filling applications. In particular, the development of injectable bone cements is of real interest for the biomedical community. The aim of this work was to study the effect of citric acid on the injectability and the setting properties of alpha-tricalcium phosphate-based cements. A comparative kinetic study was performed on cements with and without citric acid relating the hardening curves and the hydration rates using a mathematical approach. Citric acid behaved as a fluidificant during the first stages of the cement mixing. The dissolution-precipitation reactions of the alpha-tricalcium phosphate were retarded with the addition of citric acid and the compressive strength at saturation increased. In conclusion, citric acid can behave as a water-reducing admixture.

Bone Cements↗

Leaching out from acrylic bone cement. Experimental evaluation.

Using common salt and C.M.W. bone cement mixture with Barium it has been shown that even with relatively high concentrations, only a small proportion of salt is released. This release seems to be a purely surface phenomenon and the amount released is directly proportional to the surface are of the cement. If a water soluble antibiotic and NaCl are released from the bone cement by a comparable mechanism, the inclusion of antibiotic/methylmethacrylate is difficult to justify in clinical practice.

Acrylates↗

Selection of acrylic bone cements for use in joint replacement.

Commercial acrylic bone cements have been compared in terms of their mechanical, thermal and rheological properties. Significant differences have been found between the tensile strengths, shear strengths and peak polymerization temperatures of the cements tested. Large differences have been found between the viscosities of different formulations and the duration of their working periods during polymerization. Optimum cement selection is found to depend critically upon ambient conditions within the operating theatre considered in combination with the characteristics of the cements themselves. It is proposed that, at present, the only differences between commercial bone cements of relevance to successful joint replacement lie in the area of rheological properties during polymerization.

Bone Cements↗

Pathology of the bone-cement interface in loosening of total hip replacement.

The histopathology of the bone-cement interface in nine retrieved hip prostheses is reported. Three cases presented features similar to those observed by Charnley in highly successful implants, and they were classified as stable prostheses, although signs of periprosthetic bone resorption were already present. In this group a macrophagic reaction was evident even in the presence of a stable bone-cement interface, supporting the view that the release of particles by the cement or by the prosthetic components can precede the mechanical instability and be the primary cause of loosening. In six prostheses the connective tissue layer between the cement and the bone was thick and no bone trabecula reached the cement surface. The polymorphous features of this connective membrane probably resulted from instability and movement at the bone-cement and stem-cement interfaces. On the basis of the pathological changes observed in the study, the process of loosening must be far advanced before it is detected on radiographs; it is suggested that scintigraphy is the best noninvasive technique to demonstrate macrophage activation and increased bone remodeling around the cement in the early phases of loosening.

Aged↗

Mechanical properties of acrylic bone cement containing PMMA-SiO2 hybrid sol-gel material.

An organic-inorganic hybrid material, poly(methyl methacrylate) (PMMA)-SiO2 (SiO2 content of 72 wt%), was prepared by incorporating PMMA structure units covalently into an SiO2 glass network via the sol-gel approach. The hybrid sol-gel material PMMA-SiO2 was subsequently used as the solid powder component of bone cement and its mechanical properties were evaluated. The effects of the addition of tricalcium phosphate (TCP), hydroxyethyl methacrylate (HEMA), and ethylene glycol dimethacrylate (EGDMA) on the properties of the sol-gel hybrid bone cement were also investigated. The influence of these components on the temperature rise during polymerization was discussed. It was found that the new bone cement containing PMMA-SiO2 hybrid sol-gel material had higher modulus than that of Simplex-P bone cement. The addition of TCP in the new bone cement increased the Young's modulus and the polymerization time; the inverse was observed for the tensile, bending, and compressive strengths, and the polymerization temperature. The addition of HEMA and EGDMA in the new bone cement had the opposite effect of TCP. The comparison between the new sol-gel bone cement and the commercial Simplex P bone cement was discussed.

Biocompatible Materials↗

Long-term follow-up study of bioactive bone cement for repairing a segmental defect in a canine femur.

We report on a 7-year long-term follow-up study of a bioactive bone cement (BA cement) that was used to repair a segmental defect in a canine femur. Bilateral femoral segmental defects were repaired with metallic implants that were fixed to the femur using two kinds of bone cement. The BA cement used in this study consists of an apatite- and wollastonite-containing glass ceramic (AW-GC) with a bis-phenol-alpha-glycidyl methacrylate (bis-GMA)-based resin. The bone-cement interface was examined histologically. Previous short-term studies have shown that using BA cement for segmental replacement of the canine femur produced excellent biomechanical and histological results. The BA cement maintained the fixation of a metallic implant to the femur very well. In contrast, the PMMA cement did not maintain alignment under long-term weight-bearing conditions. The results of histological examinations showed direct bonding between the BA cement and bone, while an intervening soft tissue layer was observed at the bone-cement interface with the PMMA cement. The BA cement bonded to the bone through a Ca-P-rich reactive layer, which was twice as thick after 7 years than it was at 26 weeks. No adverse effects of BA cement were observed during the 7-year observation period.

Animals↗

Effect of pulsed ultrasound in combination with gentamicin on bacterial viability in biofilms on bone cements in vivo.

AIMS: The aim of this study is to investigate whether pulsed ultrasound (US) in combination with gentamicin yields a decreased viability of bacteria in biofilms on bone cements in vivo. METHODS AND RESULTS: Bacterial survival on bone cement in the presence and absence of ultrasound was compared in a rabbit model. Two bone cement samples with an Escherichia coli ATCC 10798 biofilm were implanted in a total of nine rabbits. In two groups bone cement discs loaded with gentamicin, freshly prepared and aged were used, and in one group unloaded bone cement discs in combination with systemically administered gentamicin. Pulsed ultrasound with a frequency of 28.48 kHz and a maximum acoustic intensity of 500 mW cm(-2) was applied continuously from 24 h till 72 h postsurgery on one of the two implanted discs. After euthanization and removal of the bacteria from the discs, the number of viable bacteria were quantified and skin samples were analysed for histopathological examination. Application of ultrasound, combined with gentamicin, reduced the viability of the biofilms in all three groups varying between 58 and 69% compared with the negative control. Histopathological examinations showed no skin lesions. CONCLUSIONS: Ultrasound resulted in a tendency of improved efficacy of gentamicin, either applied locally or systemically. Usage of ultrasound in this model proved to be safe. SIGNIFICANCE AND IMPACT OF THE STUDY: This study implies that ultrasound could improve the prevention of infection immediately after surgery, especially because the biomaterials, gentamicin and ultrasound used in this model are all in clinical usage, but not yet combined in clinical practice.

Animals↗

Effect of mixing method and storage temperature of cement constituents on the fatigue and porosity of acrylic bone cement.

The influence of the storage temperature of the cement constituents prior to mixing (21 vs. 4 degrees C) and the mixing method (hand mixing vs. vacuum mixing) on the uniaxial tension-compression fatigue performance and porosity of Palacos R acrylic bone cement was studied. The fatigue results were analyzed using the three-parameter Weibull equation. The fatigue performance was expressed as an index I, which was defined as the product of the Weibull characteristic fatigue life and the square root of the Weibull slope. Statistical analyses of these results show that although the mixing method (for a given storage temperature) exerts a significant influence on the fatigue performance and areal porosity, the effect of storage temperature (for a given mixing method) on either of these parameters is not significant.

Biocompatible Materials↗

A biomimetic gelatin-calcium phosphate bone cement.

The interest in new bone substitutes is rapidly increasing in the field of orthopedic surgery. A variety of calcium phosphate bone cement has been developed and different additives have been used to improve their biocompatibility and bioactivity. Following a biomimetic strategy aimed at reproducing bone characteristics, this study investigates the biological properties of a new gelatin enriched calcium phosphate cement (GEL-CP) that exhibits improved mechanical properties with respect to cement prepared without gelatin (C-CP). Human osteoblast MG63 were cultured on the surfaces of GEL-CP and were compared to cells cultured on C-CP samples, and on polystyrene of plate culture as control (C). Cell attachment, proliferation and differentiation were evaluated up to 21 days. SEM revealed that osteoblasts grown on GEL-CP showed a normal morphology and biological tests demonstrated very good rate of proliferation and viability in every experimental time. The presence of gelatin stimulated alkaline phosphatase activity, collagen and transforming growth factor 31 production. The data indicate that the new cement GEL-CP favors osteoblast proliferation, activation of their metabolism and differentiation. The remarkable improvement of the setting properties of the calcium phosphate cement due to the presence of gelatin suggest that the biomimetic composite material could be successfully applied as bone substitute.

Alkaline Phosphatase↗

Surface and chemical properties of surface-modified UHMWPE powder and mechanical and thermal properties of it impregnated PMMA bone cement, III: effect of various ratios of initiator/inhibitor on the surface modification of UHMWPE powder.

From our previous study, 3 wt% of ultra-high-molecular-weight polyethylene (UHMWPE) powder surface-modified by various ratios of methyl methacrylate (MMA) and poly(methyl methacrylate) (PMMA) solution was impregnated to improve the poor mechanical and thermal properties of conventional PMMA bone cement. In this study, various amounts of benzoyl peroxide (BPO) and hydroquinone were used for the adhesion reinforcement of UHMWPE powder with PMMA polymerized from MMA monomer (polyMMA) by the mixture of BPO and hydroquinone and ultimately to strengthen the poor mechanical and thermal properties of conventional PMMA bone cement. The tensile strengths of 3 wt% of UHMWPE powders surface-precoated with polyMMA prepared by various amounts of BPO- and hydroquinone-impregnated composite PMMA bone cements were similar to that of conventional PMMA bone cement. In particular, 3 wt% of UHMWPE powder surface precoated with polyMMA prepared with 0.75 wt% of BPO and 300 ppm of hydroquinone impregnated composite PMMA bone cement revealed the maximum tensile strength. However, no obvious significant difference was revealed, although the curing temperatures of the composite PMMA bone cements decreased from 103 degrees C to 91-97 degrees C. From these results, it was determined that the mixture of BPO and hydroquinone plays an important role in improving the poor mechanical properties of conventional PMMA bone cement. However, the thermal properties of the composite PMMA bone cements were not remarkably improved. The mechanical, chemical and thermal properties were individually confirmed using a scanning electron microscope (SEM), universal transverse mercator (UTM), Fourier transform infrared-attenuated total reflectance (FT-IR-ATR) and digital thermometer, respectively.

Bone Cements↗

Tobramycin-containing bone cement and systemic cefazolin in a one-stage revision. Treatment of infection in a rabbit model.

The efficacy of tobramycin-containing bone cement with that of systemic cefazolin for treatment of infection in a one-stage revision model is compared. In addition, the value of detecting bacterial DNA after antibiotic treatment was investigated. An implant was inserted into the right tibia of rabbits after inoculation with Staphylococcus aureus. At 28 days, the implant was removed. Subsequently, either plain bone cement with or without systemic administration of cefazolin, or tobramycin-containing bone cement was injected into the medullary canal. The tibiae were cultured 14 days after revision (Day 42), and showed a significant decrease in bacterial counts for both antibiotic groups compared with the control group (p</=0.05). The rate of infection in the tobramycin-cement group was slightly higher (2/9) than in the cefazolin group (0/8), although the difference was not significant. Persistence of bacterial DNA after antibiotic treatment may be the result of delayed clearance of DNA and not a sign of active infection. This animal model shows that in a one-stage revision tobramycin-containing bone cement can reduce size and rate of infection, although systemic cefazolin may be more efficacious. Therefore, the use of antibiotic-containing bone cement combined with systemic antibiotic might provide optimal treatment.

Animals↗

Comparison of the mechanical properties of Simplex P, Zimmer Regular, and LVC bone cements.

The mechanical properties of the three cement preparations most widely used in the United States were compared by conducting tensile and fatigue tests on Simplex P, LVC, and Zimmer Regular bone cements. Specimens of all three cement preparations were prepared for mechanical testing with and without centrifugation of the cement immediately after mixing. Although the results of the tensile testing revealed a few specific instances of significant differences in the tensile properties of the three cement preparations, there was no consistent evidence that one cement was superior in tension to the others. However, the fatigue properties of Simplex P were consistently and significantly superior to the fatigue properties of both LVC and Zimmer Regular bone cements. Centrifugation of the cement immediately after mixing significantly improved both the tensile and fatigue properties of all three bone cements. However, the fatigue strength of centrifuged Simplex P was substantially and significantly superior to the fatigue strength of the centrifuged LVC and Zimmer Regular bone cements. Since in total joint replacements bone cement is subjected to cyclic loading, these data suggest that centrifuged Simplex P is a preferable bone cement to LVC and to Zimmer Regular cement with or without centrifugation.

Biomechanical Phenomena↗

[Paranasal sinus reconstruction with bioactive bone cement--a 5-year animal experiment study].

The newly developed bioactivated bone cement Palavital is composed of polymethylmethacrylate, glass fibers and bioactive glass ceramic. The superficially located glass ceramic particles offer the possibility of true bonding of the bone cement to the bony implantation bed. Reconstruction of the frontal sinuses and the skull was performed on 9 dogs. The follow up was 14 days to 5 years. The implants were checked by tomography and histology. All implants were tolerated without any inflammatory reaction. The bond between bone and implant was demonstrated. Palavital seems to be an improvement on bone cement on a polymethylmethacrylate base.

Animals↗

[Autoradiographic determinations of carbon-14-labeled monomers and residual monomers in the tissues of Wistar rats after implantation of cold-polymerizing polymethyl methacrylate (bone cement) (author's transl)].

Self-setting acrylics, named bone cement, are taken for the reconstruction of bone defects, for the fixation of endothesis and fractures. A disadvantage of these rapid-cure acrylic compounds is the toxicity of its monomer. Infraredspectrographic measurements showed an absolute content of 12,3 per cent monomer in an acrylic-resin-compound-implant. In order to perseive the incorporation of the diffused monomer after implantation of bone cement in rats, the monomer were marked with 14C (radioactive carbon). The autoradiographic examination revealed the excretion of the marked monomer in the urine and an accumulation in kidney, liver and lungs. The results were demonstrated.

Acrylic Resins↗

Effect of pigmentation on the mechanical and polymerization characteristics of bone cement.

The impact on performance of additives to bone cement must be assessed before clinical use of the modified product. This study performed several standard acrylic bone cement tests on 3 commercially available products: Endurance, Surgical Simplex P, and Pigmented Endurance. The polymerization characteristics, consisting of doughing time, setting time, and maximum exothermic temperature, were found to be acceptable by the standards of the American Society for Testing and Materials/International Organization for Standards. For the mechanical characterization, analysis revealed statistical equivalence among all cement types, with the exception of compressive strength where Pigmented Endurance was stronger than Surgical Simplex P (P < .02). In mechanical fatigue, there were no significant differences in the log cycles to failure among the cements; however, Weibull analysis predicted Surgical Simplex P to have a higher characteristic life than the other cements. In conclusion, differences do exist among cement types, but the addition of pigment to Endurance did not alter its performance.

Biomechanical Phenomena↗

The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface.

The shear strength of trabecular bone from the femur has been studied. In general, the strongest trabecular bone is found close to the cortico-cancellous junction, though its shear strength depends also on the relationship of the trabeculae to the plane of shear. Some factors affecting the shear strength of the cement-bone interface have been investigated. In vitro, maximal cement-bone interface shear strength is obtained by exposing and thoroughly cleaning strong trabecular bone, and then forcing onto it under pressure low viscosity cement.

Adhesiveness↗

Some studies of the complement system during total hip replacement using bone cement under general anaesthesia.

Fourteen patients who underwent Charnley or Howse total hip replacement using CMW bone cement were studied. Mean values of C4 and C3 determined before the induction of anaesthesia and insertion of bone cement and also after this procedure showed no significant difference and were within the normal range. Furthermore, no evidence of C3 breakdown products was found. It was therefore concluded that neither the general anaesthetic technique nor the insertion of bone cement activated the classical or alternative complement pathways and such a mechanism was not responsible for the hypotension which occurred shortly after the insertion of bone cement in 10 cases studied.

Aged↗