Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bioartificial Organs”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Application of a novel B cell line MIN6 to a mesh-reinforced polyvinyl alcohol hydrogel tube and three-layer agarose microcapsules: an in vitro study.

This study examines the function of a novel B cell line (MIN6) enclosed in hybrid bioartificial pancreas with mesh-reinforced polyvinyl alcohol hydrogel tube (MRPT) or with improved, three-layer agarose microcapsules. MIN6 was established from insulinomas obtained by targeted expression of the simian virus 40 T-antigen gene in transgenic mice. MIN6 retains the ability to secrete insulin in response to physiological glucose concentrations. The MRPT and the three-layer agarose microcapsules, which were developed to act as an artificial pancreas, were readily permeated by insulin, glucose, and other nutrients. Both can immunoisolate enclosed MIN6 cells from the recipient's humoral and cellular immunosystems, which causes a xenogeneic rejection response. MIN6 cells (5.0 x 10(6) or 1.5 x 10(6)) were enclosed in MRPT or in a hundred three-layer microcapsules and subjected to an in vitro perifusion study or a static incubation study to observe the insulin release from each bioartificial pancreas in response to glucose stimulation. In vitro study revealed that the insulin secretion in response to 16.7 mM glucose stimulation was twice that with 3.3 mM glucose stimulation with both MRPT and the three-layer agarose microcapsules. The present study demonstrates that MIN6 effectively functions as a bioreactor for the hybrid bioartificial pancreas. The application of MIN6 cells to the hybrid bioartificial pancreas may offer a solution to the current serious dearth of organs.

Animals↗

Development of a bioartificial liver using isolated hepatocytes.

Severe liver disease is very often life-threatening and dramatically diminishes quality of life. Liver support systems based on detoxification alone have been proved ineffective because they cannot correct biochemical disorders. An effective artificial liver support system should be capable of carrying out the liver's essential processes, such as synthetic and metabolic functions, detoxification, and excretion. It should be capable of sustaining patients with fulminant hepatic failure, preparing patients for liver transplantation when a donor liver is not readily available (i.e., bridge to transplantation), and improving the survival and quality of life for patients for whom transplantation is not a therapeutic option. Recent advances in cell biology, tissue culture techniques, and biotechnology have led the way for the potential use of isolated hepatocytes in treating an array of liver disorders. Isolated hepatocytes may be transplanted to replace liver-specific deficiencies or as an important element of an auxiliary hybrid, bioartificial extracorporeal liver support device, which are important therapeutic applications for treating severe liver disease. Recently, several hepatocyte-based liver support systems have been proposed. Although there is no current consensus on its eventual design configuration, the hollow fiber hepatocyte bioreactor shows the greatest promise. Furthermore, application of tissue engineering technology, based on cell-surface interaction studies proposed by our group and others, has enhanced interest in the development of highly efficient hybrid, bioartificial, liver support devices.

Animals↗

On bioartificial liver assist system: theoretical exploration and strategies for further development.

The major difficulty in establishing a clinical effective bioartificial liver assist device for treatment of fulminate hepatic failure is limitation of our knowledge and technologies about fresh cell behaviors in culture and a lack of knowledge about the etiology and pathogenesis of hepatic coma. Increasing data from clinical and laboratory investigation have accrued indicating that toxins from necrotic liver tissue, mainly as oxygen reactive substances, have a role in the pathogenesis of hepatic encephalopathy and even multiple system organs failure. This paper presents the data available and suggests a new pathway for artificial and bioartificial liver assist system.

Aldehydes↗

Cell therapy with a tissue-engineered kidney reduces the multiple-organ consequences of septic shock.

OBJECTIVE: Gram-negative septic shock has a clinical mortality rate approaching 50%. The cause of death is secondary to a systemic inflammatory response syndrome with resulting cardiovascular collapse, ischemic damage to vital organs, and multiple-organ systems failure. Renal tubule cell injury occurs early in septic shock but is not clinically appreciated. Since renal tubule cells appear to play a critical role in the immunoregulation of stress states, renal cell therapy during septic shock may alter the detrimental multiple-organ consequences of systemic Gram-negative infection. The development of a tissue-engineered bioartificial kidney consisting of a conventional hemofiltration cartridge in series with a renal tubule assist device (RAD) containing 109 renal proximal tubule cells may be a new therapeutic approach to this clinical disorder. DESIGN: Laboratory study. SETTING: University medical school. SUBJECTS: Pigs weighing 30-35 kg. INTERVENTIONS: To assess the effect of the bioartificial kidney and the RAD in septic shock, pigs were administered 30 x 10(10) bacteria/kg body weight of Escherichia coli into the peritoneal cavity and within 1 hr were immediately placed in a continuous venovenous hemofiltration extracorporeal circuit with either a sham RAD without cells or a RAD with cells. MEASUREMENTS AND MAIN RESULTS: In this animal model, septic shock resulted within hours in acute tubule necrosis in the kidneys of all animals. Renal cell therapy resulted in significantly higher cardiac outputs and renal blood flow rates in treated animals compared with sham controls. RAD treatment also was associated with significantly lower plasma circulating concentrations of interleukin-6 and interferon-gamma compared with sham-treated animals. IL-6 release rates from peripheral blood mononuclear cells isolated from RAD-treated animals were significantly higher after endotoxin stimulation than those isolated from control animals. These physiologic and molecular alterations were associated with nearly a doubling of the average survival time in the RAD-treated group compared with the sham control group. CONCLUSION: These results demonstrate that renal cell therapy ameliorates cardiac and vascular dysfunction, alters systemic cytokine abnormalities, and improves survival time in a large animal model of Gram-negative septic shock. A cell therapeutic approach with a tissue-engineered bioartificial kidney may be a new treatment modality for this current unmet medical need.

Acute Kidney Injury↗

Animal model for liver cell banking from non-heart beating donors after prolonged ischaemia time.

BACKGROUND AND AIM: Although there is a growing interest on the use of non-heart beating donors to enlarge the liver donor pool, livers with prolonged warm ischaemia time are not currently considered for organ transplantation. We hypothesised that these organs may represent a source of hepatocytes for cell transplantation and/or use in bioartificial liver devices. Thus, we investigated if prolonged ischaemia could influence the recovery and viability of functional hepatocytes dissociated from rat livers. METHODS: Hepatocytes were isolated from the liver within 15 min after death (t=15 min) and after 4, 8 and 12h of ischaemia. Cells were either maintained in culture or cryopreserved. In all products, we evaluated cell recovery and viability, hepatocyte markers and cellular functions, including albumin and urea production. RESULTS: The number of cells per gram of tissue was similar at 15 min, 4 and 8h, while it was significantly decreased at 12h. About 0.2 x 10(6) viable cells expressing hepatocyte markers and producing albumin and urea were isolated up to 8h of ischaemia per gram of tissue. CONCLUSIONS: Recovery of viable and functional hepatocytes seems possible after prolonged ischaemia time. These data warrant the evaluation of hepatocyte isolation from human livers of non-heart beating donors.

Animals↗

Critical care apheresis: hepatic failure.

Hepatic failure is a common feature of critical care. Most hepatic dysfunction in the ICU responds to medical management and metabolic support. The role of extracorporeal organ support in hepatic failure is not as well defined as it is in renal failure and pulmonary failure. Nevertheless, artificial organ support has been successful in the treatment of advanced liver failure. Hybrid bioartificial liver substitutes show great promise, especially as a bridge to liver transplant.

Blood Component Removal↗

Therapeutic plasmapheresis.

Considerable work has been carried out over the past 25 years to define the conditions for application of plasmapheresis or plasma exchange. The use of plasma exchange in neurologic disorders such as Guillain-Barré syndrome has seen widespread application including the combination of plasma exchange with the use of intravenous immunoglobulin. Investigators have assessed the use of each therapy alone and in combination and, although both are advantageous, the relative benefits of each are still somewhat unclear. Other forms of neuropathies also seem to benefit from plasma exchange, as do some vasculitides. The use of cryosupernatant rather than frozen plasma to treat thrombotic thrombocytopenic purpura has improved outcome, but the cumulative data from many trials indicate that the mortality rate, if anything, persists at an even higher level than it did decades ago. Hemolysis, elevated liver enzymes, and low platelets syndrome, which has some characteristics similar to those of thrombotic thrombocytopenic purpura, has been shown to have variable response to plasma exchange. Plasma exchange has also been assessed as a treatment in organ failure and transplant rejection. Liver failure has shown variable response even when bioartificial livers are used. Of particular interest is the emerging use of photopheresis as an immune modulatory therapy. This is one of the newer innovative modifications of standard plasma exchange that will undoubtedly lead to interesting future therapeutic opportunities. The field continues to evolve.

Humans↗

Functional activity of human hepatoma cells transfected with adenovirus-mediated hepatocyte nuclear factor (HNF)-4 gene.

Fulminant hepatic failure (FHF) is still associated with high mortality despite recent advances in medical management. There is need of an effective and safe bioartificial liver (BAL) support to help keep patients with FHF alive until an organ becomes available for transplantation or the native liver recovers. The aim of this study was to establish highly functional liver cells by means of transfecting hepatocyte nuclear factor (HNF)-4 gene for the development of BAL. We constructed adenovirus vector carrying rat HNF-4 cDNA, and transfected to hepatoma-derived cell lines, HepG2 and HuH-7, to enforce expression of the exogenous HNF-4 gene. We analyzed expression of HNF-4, HNF-1, and liver-specific genes in cells infected by the adenovirus vector expressing HNF-4. Adenovirus-mediated HNF-4 gene transfer resulted in increases in expressions of HNF-4, HNF-1, and liver-specific genes such as apolipoproteins, alpha1-antitrypsin (alpha1-AT), phosphoenolpyruvate carboxy-kinase, cytochrome P450 families, and glutamine synthetase in transfected hepatoma cells. Cells overexpressing HNF-4 removed ammonia from medium supplemented with NH4Cl to a greater extent than control cells. These findings demonstrated that transfected cell lines restored differentiated gene expressions and liver-specific function by the overproduction of HNF-4. HNF-4-overexpressing hepatocyte cell lines are useful for bioreactor of BAL systems.

Adenoviridae↗

Biocompatibility and immunology in the encapsulation of islets of Langerhans (bioartificial pancreas).

Successful transplantation of encapsulated islets (bioartificial pancreas) would circumvent problems of islet availability and rejection in the treatment of insulin-dependent diabetes with biological organ replacement. Alginates are widely used as a hydrogel matrix or membrane for immunoprotected transplantation. A major problem in the use of diffusion-based devices is the biocompatibility of the material used. The foreign body reaction after implantation of empty microcapsules into different compartments in rats, dogs and pigs is evaluated in this article. However, biocompatibility of the bioartificial pancreas has three different aspects: reaction of the entrapped islet to the encapsulation technique and material; reaction of the recipient against the incorporated device ( = foreign body reaction); and finally the reaction of the recipient against the encapsulated islet ( = immunology of bioartificial pancreas). It is obvious from different experiments that even if foreign body reactions (reactions against material) are almost abolished the recipient may react against material released from the encapsulated islet. In conclusion, transplantation of encapsulated islets induces various morphological reactions (i.e. inflammation and fibrosis) as a result of a variety of donor and recipient related factors. Therefore, the use of an adequate animal model that reflects the human situation is essential for progress in the development of a bioartificial pancreas.

Alginates↗

An organic-inorganic hybrid scaffold for the culture of HepG2 cells in a bioreactor.

Much interest has recently been shown in the potential utility of bioartificial liver (BAL) as a bridge support for patients and as a module for experimental purposes. A radial-flow bioreactor (RFB), one of the perfused bed/scaffold-type bioreactors, enables a highly functional three-dimensional culture as BAL. The functional capacity of bioreactors depends not only on their mechanistic structures but also on scaffolds packed in them. In the present study, we examined the possible utility of a new porous organic-inorganic-hybrid scaffold in an RFB. The scaffold was made from tetraethoxysilane (TEOS) and polydimethylsiloxane (PDMS) by a sol-gel method using sieved sucrose particles as a porogen. In the porous TEOS-PDMS hybrid scaffold, human hepatocellular carcinoma cells (HepG2) proliferated actively and formed cell clusters more efficiently than they did in a polyvinyl-alcohol scaffold. When cultivated in PDMS-TEOS, HepG2 cells secreted a approximately three-fold greater amount of albumin than that secreted in a monolayer culture. For potential application of BAL to pharmacological studies and future clinical use, it is essential to develop a method to propagate liver cells that maintain highly specific functions. The present results indicate that PDMS-TEOS may be a promising scaffold for developing such functional culture methods.

Albumins↗

Bioartificial liver support.

Orthotopic liver transplantation is the only definitive therapy for patients with fulminant hepatic failure (FHF). However, due to shortage of organs, a large number of patients die before a liver can be procured for transplantation. In FHF the need for a liver is particularly urgent because of rapid deterioration in the patients' condition with the onset of cerebral edema and intracranial hypertension leading to irreversible brain damage. It is thus necessary to develop an extracorporeal liver support system to help maintain patients alive and neurologically intact until an organ becomes available for transplantation. Multiple attempts have been made, ranging from the use of plasma exchange to utilization of charcoal columns and extracorporeal devices loaded with liver tissue to develop liver support systems for treating patients with acute severe liver failure. None of these systems has achieved wide clinical use, and FHF due to multiple causes continues to be associated with significant morbidity and mortality. In this paper, the authors review the history of extracorporeal liver support for acute liver failure and discuss their experience with a hollow fiber bioartificial liver support system utilizing porcine hepatocytes in the treatment of patients with acute liver failure.

Acute Disease↗

Liver support therapy: an overview of the AMC-bioartificial liver research.

Acute liver failure (ALF) is a disease with a mortality of 60-90% depending on the cause. Only high-urgency liver transplantation is able to increase survival compared to standard intensive care therapy. Liver transplantation is hampered by the increasing shortage of organ donors, resulting in a high incidence of patients with ALF dying on the transplantation waiting list. Amongst a variety of liver assist therapies, bioartificial liver (BAL) therapy is marked as the most promising solution to bridge ALF patients to liver transplantation or to liver regeneration, since several BAL systems showed significant improvement of survival time in experimental animals with irreversible ALF. One of these systems has been developed at the Academic Medical Center in Amsterdam, The Netherlands - the AMC-BAL. This overview describes the development of the AMC-BAL based on porcine hepatocytes which was started 10 years ago. Positive results of in-vitro functionality and in vivo safety and efficacy led to a successful phase I study in 12 ALF patients in Italy. However, xenotransplantation legislation in many European countries prohibits the use of porcine hepatocytes in clinically applied BAL systems. The future of the BAL, therefore, resides in the development of a human-derived hepatocyte cell line as biocomponent of BAL systems.

Animals↗

New approaches to supporting the failing liver.

With the continued, growing disparity between the numbers of organ donations and patients waiting for liver transplantation, various efforts have been made to optimize the allocation of organs, as well as to devise means to support the failing liver. Over the years, the development of bioartificial liver-assist devices has aimed at replacing the three main functions of hepatocytes, which are synthetic, metabolic, and excretory. The application of porcine hepatocytes in humans to carry out biotransformation, as well as other metabolic functions and refinement of the membrane separator, have yielded some promising results in supporting patients with acute liver failure. Further advances will need to be made before these bioartificial devices can be considered for routine application in clinical settings.

Animals↗

Bioartificial liver: current status.

Liver failure remains a life-threatening syndrome. With the growing disparity between the number of suitable donor organs and the number of patients awaiting transplantation, efforts have been made to optimize the allocation of organs, to find alternatives to cadaveric liver transplantation, and to develop extracorporeal methods to support or replace the function of the failing organ. An extracorporeal liver support system has to provide the main functions of the liver: detoxification, synthesis, and regulation. The understanding that the critical issue of the clinical syndrome in liver failure is the accumulation of toxins not cleared by the failing liver led to the development of artificial filtration and adsorption devices (artificial liver support). Based on this hypothesis, the removal of lipophilic, albumin-bound substances, such as bilirubin, bile acids, metabolites of aromatic amino acids, medium-chain fatty acids, and cytokines, should be beneficial to the clinical course of a patient in liver failure. Artificial detoxification devices currently under clinical evaluation include the Molecular Adsorbent Recirculating System (MARS), Single-Pass Albumin Dialysis (SPAD), and the Prometheus system. The complex tasks of regulation and synthesis remain to be addressed by the use of liver cells (bioartificial liver support). The Extracorporeal Liver Assist Device (ELAD), HepatAssist, Modular Extracorporeal Liver Support system (MELS), and the Amsterdam Medical Center Bioartificial Liver (AMC-BAL) are bioartificial systems. This article gives a brief overview on these artificial and bioartificial devices and discusses remaining obstacles.

Humans↗

Differentiated growth of human renal tubule cells on thin-film and nanostructured materials.

Over 300,000 Americans are dependent on hemodialysis as treatment for renal failure, and kidney transplantation is limited by scarcity of donor organs. This shortage has prompted research into tissue engineering of renal replacement therapy. Existing bioartificial kidneys are large and their use labor intensive, but they have shown improved survival compared to conventional therapy in preclinical studies and an US Food and Drug Administration-approved phase 2 clinical trial. This hybrid technology will require miniaturization of hemofilters, cell culture substrates, sensors, and integration of control electronics. Using the same harvesting and isolation techniques used in preparing bioartificial kidneys for clinical use, we characterized human renal tubule cell growth on a variety of silicon and related thin-film material substrates commonly used in the construction of microelectromechanical systems (MEMS), as well as novel silicon nanopore membranes (SNMs). Human cortical tubular epithelial cells (HCTC) were seeded onto samples of single-crystal silicon, polycrystalline silicon, silicon dioxide, silicon nitride, SU-8 photoresist, SNMs, and polyester tissue culture inserts, and grown to confluence. The cells formed confluent monolayers with tight junctions and central cilia. Transepithelial resistances were similar between SNMs and polyester membranes. The differentiated growth of human tubular epithelial cells on MEMS materials strongly suggests that miniaturization of the existing bioartificial kidney will be feasible, paving the way for widespread application of this novel technology.

Biocompatible Materials↗

Clinically established hemostatic scaffold (tissue fleece) as biomatrix in tissue- and organ-engineering research.

Various types of three-dimensional matrices have been used as basic scaffolds in myocardial tissue engineering. Many of those are limited by insufficient mechanical function, availability, or biocompatibility. We present a clinically established collagen scaffold for the development of bioartificial myocardial tissue. Neonatal rat cardiomyocytes were seeded into Tissue Fleece (Baxter Deutschland, Heidelberg, Germany). Histological and ultrastructural examinations were performed by DAPI and DiOC(18) staining and electron microscopy, respectively. Force measurements from the spontaneously beating construct were obtained. The constructs were stimulated with agents such as adrenalin and calcium, and by stretching. Passive stretch curves were obtained. Spontaneous contractions of solid bioartificial myocardial tissue (BMT), 20 x 15 x 2 mm, resulted. Contractions continued to week 12 (40% of BMTs) in culture. Histology revealed intercellular and also cell-fibril junctions. Elasticity was similar to that of native rat myocardium. Contractile force increased after topical administration of Ca(2+) and adrenaline. Stretch led to the highest levels of contractile force. In summary, bioartificial myocardial tissue with significant in vitro longevity, spontaneous contractility, and homogeneous cell distribution was produced using Tissue Fleece. Tissue Fleece constitutes an effective scaffold to engineer solid organ structures, which could be used for repair of congenital defects or replacement of diseased tissue.

Animals↗