Office fluorescein angioscopy.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: This study sought to elucidate angioscopic findings in totally occluded vessels before and after intervention. BACKGROUND: Coronary angioscopy allows direct visualization of the lumen surface of the coronary arteries; however, the utility of coronary angioscopy during coronary angioplasty of vessels with a total occlusion is unknown. METHODS: Twenty-one consecutive patients (mean [+/- SD] 58 +/- 9 years, range 39 to 77; 3 women, 18 men) undergoing dilation of an occluded vessel were studied with coronary angioscopy. Occlusions were classified as functional in 8 patients (Thrombolysis in Myocardial Infarction [TIMI] flow grade 1) and anatomic in 13 (TIMI flow grade 0). Once the guide wire had crossed the occlusion, coronary angioscopy was attempted before and after angioplasty. RESULTS: In all patients, coronary angioscopy before dilation visualized protruding material occluding the coronary lumen where the guide wire was wedged. The occlusion consisted of red thrombus in 19 patients (90%) (2 with isolated occlusive thrombus, 17 with thrombus associated with atherosclerotic plaque) and protruding yellow plaque in 2 patients (10%). However, on angiography only 7 occlusions (33%) had data consistent with thrombus (p < 0.01 vs. coronary angioscopy). Successful dilation was obtained in 20 patients. After dilation, coronary angioscopy was repeated in 18 patients, revealing residual thrombus with plaque in 16 (89%) and a residual yellow plaque in 2. In addition, coronary angioscopy revealed coronary dissections in 13 patients (72%); however, angiography revealed dissections only in 10 patients (55%) and residual thrombus in 2 (10%) (p < 0.001). In one patient, coronary angioscopy visualized silent distal embolization of a red thrombus not previously recognized on angiography. CONCLUSIONS: Before intervention, coronary angioscopy provides unique insights into the pathologic substrate of occluded coronary vessels. An occlusive plaque with thrombus is the most common underlying substrate in these lesions. After successful dilation, angiographically silent mural thrombus is seen in most patients. This information could be used to assist in the selection of candidates and type of coronary interventions and could also prove to be of prognostic value in patients with occluded vessels.
Coronary angioscopy can directly visualize luminal morphology and stent architecture. This new technology may provide insights into the stent mechanism of action and help guide stent procedures. Visualization of the target vessel segment with a 4.5Fr angioscope was attempted before and/or after Palmaz-Schatz coronary stent implantation in 50 patients. The target vessel segment was successfully visualized in 48 patients (96%). In 24 patients, angioscopy was performed both after balloon angioplasty and then again after stenting. In 16 of these 24 patients a dissection was documented by angioscopy after balloon angioplasty, and in each patient the dissection was absent after stenting. Angioscopy influenced the clinical management of 18 (37.5%) patients. Clinical decisions directly influenced by angioscopy included intracoronary thrombolytic therapy for thrombus visualized angioscopically, which had been unsuspected by angiography (n = 7), withholding intracoronary thrombolytic therapy for patients with suspected thrombus not confirmed by angioscopy (n = 4), repeat angioplasty in patients in whom plaque was found to be bulging into the lumen at the stent articulation site (n = 4), additional stents placed when angioscopy revealed significant proximal or distal disease (n = 4), or an unsuspected gap between 2 tandem stents (n = 1). Coronary angioscopy safely visualized stented vessel segments in most patients. Angioscopic observations provided insights into the stent mechanism of action and, in some cases, influenced clinical management.
In a prospective study, 60 consecutive cases of vascular endoscopy were analyzed to examine the role of angioscopy in infrainguinal vascular procedures. A total of 52 patients had 60 separate vascular endoscopy procedures performed as an adjunct to various vascular procedures; results of intraoperative arteriography were available in 38 of 60 cases. All patients were followed for at least 42 months. The 19 patients who underwent thrombectomy with angioscopy were compared with 19 age-matched control subjects who underwent infrainguinal thrombectomy without angioscopy to evaluate the influence of angioscopy on primary and secondary patency rates. Angioscopy allowed observation of 50 lesions; angiography failed to detect three. These findings altered surgical management in 24 cases (40%). Primary patency rates for the control and experimental thrombectomy groups were 38.8% and 6.5% at 42 months, respectively (p = 0.010 based on log-rank test). Secondary patency rates for the control and experimental groups at 42 months were 63.8% and 49%, respectively (p = 0.521). The limb salvage rate was 89% at 42 months for both groups (p = 0.973). Angioscopy provides the clinician with a direct view while he or she is performing vascular procedures. However, there was no statistical improvement in secondary patency and limb salvage rates. Furthermore, the use of angioscopy during thrombectomy may increase the propensity for subsequent intervention as evidenced by the frequency of changes in surgical management and the lower primary patency rate.
OBJECTIVES: This study was undertaken to compare coronary angioscopy with angiography for the detection of intimal dissection and intracoronary thrombus. BACKGROUND: It has been demonstrated previously that coronary angioscopy provides more intravascular detail than cineangiography. Both imaging methods have to be compared directly to assess the additional diagnostic value of angioscopy. METHODS: The angiograms and videotapes of 52 patients who had undergone angioscopy were reviewed independently by two observers unaware of other findings. Classic angiographic definitions were used for dissection and thrombus. Angioscopic dissection was defined as visible cracks or fissures on the lumen surface or mobile protruding structures that are contiguous with the vessel wall. Angioscopic thrombus was defined as a red, white or mixed red and white intraluminal mass. RESULTS: Angiography and angioscopy were in agreement in 40.4% of cases in the absence of thrombus and in 11.5% in the presence of thrombus. No fewer than 25 (48.1%) angioscopically observed thrombi remained undetected at angiography. With angioscopy as the standard, although the specificity of angiography for thrombus was 100%, sensitivity was very low at 19%. Angioscopic dissection was present in 40 patients (76.9%) versus angiographic dissection in 15 patients (28.8%). With regard to dissection, there was no correlation between the two imaging methods (r phi = 0.15, p = 0.29). CONCLUSIONS: Coronary angiography underestimates the presence of intracoronary thrombus. Angioscopy and angiography are complementary techniques for detecting and grading intimal dissections.
The purpose of this study was to compare angiography and angioscopy for the detection of thrombus during coronary interventional procedures. The diagnosis of coronary thrombus has important clinical implications. Angioscopy can directly visualize the coronary luminal surface and may be more accurate than angiography in the diagnosis of thrombus. Angiography and angioscopy were sequentially performed in 75 patients undergoing a variety of interventional cardiology procedures during 117 distinct procedural time points. The angiographic presence of thrombus was defined as a noncalcified filling defect outlined on at least 3 sides by contrast media. The angioscopic presence of thrombus was defined as red material protruding into the lumen (intraluminal thrombus) or adherent to the luminal wall (mural thrombus) that persisted despite flushing. Thrombus was detected on 14 occasions (12.0%) by angiography compared with 48 (41.0%) by angioscopy (p < 0.05). In 4 of the 14 episodes (28.6%) of angiographic filling defects, angioscopy found no evidence of thrombus and provided an alternative explanation for the angiographic filling defect. When angioscopy was used as a reference standard, the sensitivity of thrombus detection by angiography was 20.8%, with a specificity of 94.2% and a predictive value of 71.4%. The sensitivity of angiography for the detection of intraluminal (protruding into the lumen) thrombus was 100% compared with only 10% for mural (adherent to the luminal wall) thrombus (p < 0.05). Angioscopy was significantly more accurate than angiography for detecting coronary thrombus and may be considered an improved reference standard for this diagnosis.
The degree of residual stenosis by fresh thrombus after laser recanalization was compared by use of angiography and angioscopy. Fifteen NZW rabbits were used. Occlusive fresh thrombus in rabbit aorta was produced by mechanical deendothelialization and external constrictions simulating clinical situations. Argon laser angioplasty using microlens-tipped optical fiber and/or 2 mm hot-tip probe was done to recanalize thrombosed aorta in 10 animals. Two-mm hybrid probe was used in 5. Percent area stenosis (% AST) was derived by use of the mean radius method obtained by angiography of stenotic segments in two orthogonal views and/or from angioscopy. All 15 totally occluded vessels with fresh thrombus were recanalized. Four minor perforations occurred. Following argon laser angioplasty with the microlens optical fiber, percent stenosis was reduced to 53% in diameter by angiography and 66 in % AST by angioscopy, and to 48% and 55 respectively following hot-tip probe. After laser angioplasty with the hybrid probe, residual stenosis by fresh thrombus was 37% in diameter on angiography and 63 in % AST on angioscopy. Mean percent AST was 62% with angiography and 52% with angioscopy, and there was no correlation between them (r = -0.028). Angioscopy provided cross-sectional topographic views of thrombosed lumen and showed charring and shrinkage of thrombus following laser angioplasty. This study suggests that (1) continuous-wave laser angioplasty using modified optical fibers can recanalize thrombotic vascular occlusion, (2) laser angioplasty by hot-tip probe could evacuate fresh thrombus more than microlens fiber on angioscopy, and (3) angiographic % AST did not correlate with angioscopic % AST.
The purpose of the present study was to use the complementary information of angiography, intravascular ultrasound, and intracoronary angioscopy before and after directional atherectomy to characterize the postatherectomy appearance of vessel wall contours and the mechanism of lumen enlargement. Directional coronary atherectomy aims at debulking rather than dilating a coronary artery lesion. The selective removal of the plaque may potentially minimize the vessel wall damage and lead to subsequent better late outcome. Whether plaque removal is the main mechanism of action has only to be assessed indirectly by angiography and warrants further investigation with detailed analysis of luminal changes and vessel wall damage by ultrasound and direct visualization with angioscopy. Twenty-six patients have been investigated by quantitative angiography, intravascular ultrasound, and intracoronary angioscopy (n = 19) before and after atherectomy. In addition, all retrieved specimens were microscopically examined. Ultrasound imaging showed an increase in lumen area from 1.95 +/- 0.70 mm2 to 7.86 +/- 2.16 mm2 at atherectomy. The achieved gain mainly resulted from plaque removal because plaque plus media area decreased from 18.16 +/- 4.47 mm2 to 13.13 +/- 3.10 mm2. Vessel wall stretching (i.e., change in external elastic lamina area) accounted for only 15% of lumen area gain. Luminal gain was higher in noncalcified (6.52 +/- 2.12 mm2) lesions than in lesions containing deeply located calcium (5.19 +/- 0.99 mm2) and lowest in superficially calcified lesions (5.41 +/- 2.41 mm2). Ultrasound imaging identified an atherectomy byte in 85% of the cases, whereas angioscopy revealed such a crevice in 74%. The complementary use of the three techniques revealed an underestimation of the presence of dissection/tear and new thrombus by angiography (10% and 4%) and ultrasound imaging (12% and 0%) compared with angioscopy (26% and 21%). The combined use of angiography, ultrasound, and angioscopy reveals that the postatherectomy luminal lining is not as regular and smooth as that seen by angiography. Luminal enlargement with atherectomy is achieved by plaque excision rather than arterial expansion.
This prospective study was designed to establish whether vascular endoscopy would provide more information on the graft lumen than standard completion angiography during infrainguinal bypass surgery. Ninety-nine patients with 102 infragenicular bypass grafts who underwent both angiography and angioscopy intraoperatively were evaluated. In 99 of the 102 patients the indication was critical limb ischaemia. Of the 102 bypass grafts, 81 were autogenous vein. Distally, 24 grafts were anastomosed to the below-knee popliteal segment, 64 extended to the crural and 14 to the pedal arteries. On completion of the distal anastomosis, grafts were first evaluated by angiography and then by angioscopy. The images obtained with the two monitoring modalities were compared by the operating surgeon and re-explorations were performed immediately if necessary. Completion angiography and angioscopy produced images of good quality in 96 and 97 cases, respectively. In 12 cases completion angiography showed abnormalities. Of these, five were located below the distal anastomosis and were not accessible to angioscopic examination. Conduit defects were found in seven instances. In one of them angioscopy showed the angiogram to be false-positive. Of the 90 grafts with normal completion angiograms, seven were found to show significant pathology on angioscopy. Compared to angioscopy, the sensitivity and specificity of angiography to detect abnormalities within the graft was 46% and 98%, respectively. Our results suggest that vascular endoscopy is superior to angiography for disclosing conduit defects, but that it does not provide adequate information about the distal arterial anatomy.
BACKGROUND: Elevated troponin T levels in non-ST-elevation acute coronary syndromes (NSTE-ACS) have been shown to predict an adverse outcome. Furthermore, it has been reported that troponin T could help improve the effectiveness of such new antithrombotic drugs as platelet GPIIb/IIIa antagonists and low-molecular-weight heparins. We hypothesized that such elevated troponin T levels in NSTE-ACS indicate the presence of thrombus at culprit lesions, and this hypothesis was verified through the use of coronary angioscopy. METHODS AND RESULTS: We studied 57 consecutive patients with NSTE-ACS who underwent preinterventional angioscopy. Before catheterization, we obtained blood samples to determine troponin positivity, and the patients were then classified as either troponin-positive or troponin-negative groups (diagnostic threshold, 0.1 ng/mL). Using angioscopy at the culprit lesions, we examined the presence of coronary thrombus, yellow plaque, and complex plaque. Moreover, we compared the preinterventional angiographic parameters (thrombus and complexity of the culprit lesion, and TIMI flow) between the two groups. Twenty-two patients were troponin-positive and 35 patients were troponin-negative. Univariate analyses indicated that the TIMI flow and the incidence of coronary thrombus detected with angioscopy correlate with the elevated troponin T levels. A multivariate logistic regression analysis showed the presence of coronary thrombus detected with angioscopy to be the only independent factor associated with elevated troponin T levels in patients with NSTE-ACS (odds ratio, 22.1; 95% CI, 2.59 to 188.42; P=0.0046). CONCLUSIONS: Using angioscopy, the elevated troponin T levels in NSTE-ACS were confirmed to be strongly associated with the presence of coronary thrombus.
The purposes are to assess the problems associated with intravascular imaging methods such as angioscopy and intravascular ultrasound (IVUS) and to evaluate their efficacy through the results of our observations. A total of 54 limbs in 53 patients, 50 patients with chronic venous insufficiency and 3 patients with deep vein thrombosis, were diagnosed and operated on using angioscopy (Olympus OES, order made type) and IVUS (Endosonics, model 82700). The imaging catheters were inserted through a branch of the long saphenous vein and the valves and the intraluminal views were observed. By angioscopy, intraluminal views were clearly observed in 98% of all lesions. However, observation became more difficult in iliac veins compared to in femoral and in long saphenous veins (p < 0.01). Venous wall and thrombus were detected more by IVUS than by angioscopy (p < 0.01), but only 21 valves (24%) were visualized by IVUS among the 88 valves observed by angioscopy. The intravascular imaging method of angioscopy is more suitable for observing valves and intraluminal views compared with IVUS, whereas IVUS is more suitable for observing the cross-sectional venous wall.
UNLABELLED: To study the immediate effects of prolonged total balloon inflation during PTCA, 41 patients (44 lesions) with chronic stable angina were randomized for prolonged sequential inflations (three to five inflations of 3 to 5 min each, for a total duration of > or = 12 min, group 1, n = 20 lesions) or 'standard' sequential inflations (three to five inflations of < or = 1 min each, for a total duration of < or = 3 min, group 2, n = 24 lesions). The mean duration of total balloon inflation time was 958 +/- 129 s in group 1 vs 205 +/- 46 s in group 2. Results of angioplasty were assessed on both angiography and percutaneous transluminal coronary angioscopy performed immediately after the procedure. High quality imaging of the coronary lumen and lesion morphology was possible on angioscopy in all patients without any complications. Post-PTCA angiographic percent diameter stenosis was significantly less in group 1 compared to group 2: 26 +/- 10% vs 36 +/- 8% (P < 0.05). On angioscopy, flaps were seen in 16 patients in group 2, but in only six in group 1 (P < 0.02). There was no difference in the incidence of thrombi on angioscopy between the two groups (group 1: nine cases, group 2: 10 cases). Sensitivity of angiographic detection of flaps and thrombi was poor: 10% and 12% respectively. One patient in each group developed a longitudinal dissection, detected on both angiography and angioscopy. CONCLUSIONS: (1) prolonged sequential balloon inflations lead to less residual luminal stenosis after PTCA, with a decreased incidence of intimal flaps in comparison with standard inflations. (2) Post-PTCA transluminal coronary angioscopy is safe and offers better assessment of luminal effects of PTCA than angiography.
The limitations of angiography, when it is used as the sole method of vascular assessment, are increasingly apparent as vascular intervention becomes more sophisticated. Angioscopy could be an adjunctive diagnostic modality by differentiating among thrombus, dissection, and atheroma, and by monitoring the response to therapy. However, angioscopy requires a blood-free field for adequate visibility, and this may be difficult to obtain. The feasibility of carbon dioxide (CO2) and various saline delivery methods for clarifying the viewing field for percutaneous angioscopy was investigated. Angioscopy of femoral and iliac arteries on nine dogs was performed. Saline was infused by hand injection, pressure bag infusion, or mechanical power injection, and CO2 gas was injected using a special gas injector. The clarity of the viewing field was graded for each medium and method. Excellent quality antegrade femoral angioscopy was obtained with CO2. The superiority of CO2 injection in comparison with power-injected saline approached statistical significance (P = .06). Power-injected CO2 and power saline were superior to hand-injected or pressure bag-injected saline for maintaining sufficient visibility. Retrograde iliac angioscopy was possible without inflow occlusion, but required high flow rates (only possible with power-injected saline or CO2). CO2 injected under controlled circumstances holds promise as a medium to improve angioscopic visibility.
Definite diagnosis of pulmonary embolism (PE) by conventional methods such as angiography is frequently difficult. If residual thromboemboli incorporated into the pulmonary arterial wall or in the distal small segments are visible, differential diagnosis of PE versus primary pulmonary hypertension (PPH) can be made without open-chest pulmonary biopsy. Six patients suspected of having acute PE, 6 suspected of having chronic PE, and 4 with PPH diagnosed by pulmonary biopsy underwent percutaneous pulmonary angioscopy. In patients suspected of having PE, globular and mural thromboemboli were detected by both angioscopy and angiography in 4 and 1 patients, respectively. By angioscopy, emboli incorporated into the arterial wall were detected in 7 and microemboli obstructing the distal small segments were detected in 6. However, these emboli were detected by angiography in none. In patients with PPH, no embolus was detected by angioscopy and angiography. Angioscopically, however, stenoses were observed in the distal small segments in all patients. The results indicate that residual pulmonary thromboemboli in PE and stenoses of distal pulmonary arteries in PPH are detectable by percutaneous angioscopy, and therefore this method is feasible for differential diagnosis of PE.
OBJECTIVES: The purpose of this study was to determine the prevalence of intracoronary thrombus and associated anatomic abnormalities in patients with postinfarction angina using coronary angioscopy and angiography. BACKGROUND: Postinfarction angina, previously studied by angiographic methods only, identifies patients at high risk for sudden death, recurrent angina and refractory angina. The recent development of coronary angioscopy, which permits direct observation of a thrombus or atheroma and is especially used for the detection of intraluminal changes, encourages a reexamination of the pathogenesis of postinfarction angina. METHODS: Fifty-one consecutive patients with a diagnosis of acute myocardial infarction underwent cardiac catheterization. Coronary angiography followed immediately by coronary angioscopy was performed in 17 patients with and 34 without postinfarction angina during the same period of time (10.2 +/- 3.7 or 15.7 +/- 5.5 days [mean +/- SD]) after the onset of acute myocardial infarction. RESULTS: The frequency of thrombus, as observed by angioscopy, was significantly higher in patients with than without postinfarction angina (17 of 17 vs. 5 of 34, respectively, p < 0.01). There were no significant differences between groups with respect to degree of stenosis in the infarct-related artery, number of vessels with significant stenosis, presence of collateral flow, type of therapy and risk factors. CONCLUSIONS: Infarct-related artery thrombus is universally present in postinfarction angina and may be the primary pathogenic factor. Angioscopy is much more sensitive than coronary angiography for the detection of coronary thrombus.
OBJECTIVES AND STUDY DESIGN: The diagnostic capability of angioscopy for endoluminal evaluation is established and its superiority over arteriography for completion studies has been confirmed. The therapeutic use of angioscopy in vein graft preparation is more controversial. The aim of this prospective study was to establish whether angioscopic vein preparation confers real benefits over existing techniques. METHODS: Forty-seven patients were randomised to either full angioscopic (ANG) vein preparation (23 patients) or conventional (CON) in situ grafting (19 patients). All patients underwent completion studies with arteriography and angioscopy and postoperatively, entered a Duplex graft surveillance programme. RESULTS: There was a significant difference in the incidence of wound morbidity: 26% in the ANG group as against 63% in the CON group (Fisher's exact test: p = 0.043), but no significant differences with respect to duration of operation, duration of vein graft preparation, length of hospital stay and both 30 day and 12 month secondary cumulative patencies (log rank test: p > 0.5). Completion angioscopy detected eight persistent valve cusps in six patients, all missed at arteriography, but failed to detect arteriovenous fistulae. CONCLUSIONS: Angioscopic preparation reduces wound morbidity and complements arteriography for detecting intraoperative defects. A large, prospective, randomised trial is now warranted to fully evaluate the potential therapeutic role of angioscopy with respect to current vascular practice.