Search PubMedSearch

SEARCH · Search PubMed

Results for “likelihood”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2Linked to original sources

The effect of dietetic counseling combined with digital tools intervention on hemodynamic markers in Greek adults: The GATEKEEPER Study.

BACKGROUND AND AIM: Hypertension is a leading cardiovascular risk factor with substantial global impact on morbidity, mortality, and healthcare costs. While lifestyle interventions remain central to management, mHealth technologies offer promising adjunctive support, though their clinical effectiveness remains uncertain. This study evaluated whether combining dietetic counseling with digital tools improves hemodynamic markers in adults aged ≥55 years with increased cardiometabolic risk. METHODS AND RESULTS: This 3-month RCT (NCT05031299) included 954 adults with at least one metabolic syndrome risk factor, allocated 1:1:1 to Standard Care (dietetic counseling), Platform (counseling plus web-based platform), or Platform + Devices (counseling plus platform plus wearables). Outcomes included anthropometrics, lifestyle characteristics, blood pressure, pulse pressure, and estimated pulse wave velocity, analyzed using linear mixed-effects models adjusted for age and sex. All groups improved over 3 months. Waist circumference decreased by -6.29, -4.92, and -4.69 cm across Standard Care, Platform, and Platform + Devices groups respectively, and systolic blood pressure declined by -4.84 to -7.15 mmHg across groups. The Platform + Devices group showed greater increases in physical activity (94.62 MET-min/week; 95% CI 66.49 to 122.76) and greater reductions in pulse pressure (-3.90 mmHg; -6.58 to -1.22) versus Standard Care. Weight loss was associated with lower odds of hypertension (OR 0.4; 95% CI 0.2-0.7), greater likelihood of hypertension reversal (OR 3.6; 1.2-10.3), and higher probability of achieving normal pulse pressure (OR 1.8; 1.1-3.1). CONCLUSIONS: Dietary lifestyle intervention improved cardiometabolic outcomes, with limited added benefit from digital tools. Weight loss was the primary driver of hemodynamic improvement.

Aged

Vaginal Hysterectomy Versus Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery Hysterectomy; Results of a Randomised Controlled Trial.

OBJECTIVE: To compare Vaginal Hysterectomy (VH) with Vaginal Assisted Natural Orifice Transluminal Endoscopic Surgery (NOTES) hysterectomy (VANH) as a day-care procedure. DESIGN: Single-blind, multicentre randomised controlled trial. SETTING: Two Dutch non-academic teaching hospitals. POPULATION: Women aged &#x2265;&#x2009;18&#x2009;years undergoing hysterectomy for benign indications. METHODS: Women were randomised 1:2 (VH or VANH). Primary outcome was SDD. Secondary outcomes included operative time, rate of elective salpingectomies, intraoperative blood loss, complications (Clavien-Dindo), pain scores (NRS) and analgesic use, post-operative recovery (RI-10), and quality of life (EQ-5D-5L). Analyses were performed on an intention-to-treat basis. RESULTS: A total of 113 patients were included in the analyses (n&#x2009;=&#x2009;42 VH, and n&#x2009;=&#x2009;71 VANH). SDD occurred significantly more frequently in the VANH group (87.3%) than VH group (71.4%; OR 2.76, 95% CI 1.04-7.25; p&#x2009;=&#x2009;0.04). VANH was associated with a significantly shorter operative time (median 55&#x2009;min versus 65&#x2009;min; p&#x2009;=&#x2009;0.005), less blood loss (median 50&#x2009;mL vs. 150&#x2009;mL; p&#x2009;<&#x2009;0.001) and more often elective opportunistic salpingectomy compared to VH (100% vs. 77.4%; p&#x2009;=&#x2009;0.008). NRS were significantly lower in the VANH group the first hour post-operative (3 vs. 1, p&#x2009;<&#x2009;0.001). Post-operative complications (VH 9.5% vs. VANH 15.5%; p&#x2009;=&#x2009;0.34), readmission (VH 4.8% vs. VANH 8.5%; p&#x2009;=&#x2009;0.47), analgesic use, recovery, and quality of life were not statistically significant. CONCLUSIONS: VANH is a safe and effective alternative to VH, offering a higher likelihood of SDD, shorter operative time, reduced blood loss, and more often an elective salpingectomy, without increased complications or differences in pain, recovery, or quality of life.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Suppression of HIV-1 replication in CEM-A cell cultures by trans-splicing group I introns targeting PAS/PBS sequences and conditionally expressing &#x394;N-Bax.

Anti-HIV group I introns containing antisense guide sequences directed against the HIV-1 primer activation signal and primer-binding site (PAS/PBS) were designed and evaluated. Because PAS/PBS sequences are present in the viral RNA species examined, these RNAs can serve as trans-splicing substrates. The introns were active against both artificial target RNAs and viral RNA generated during infection. Cleavage and degradation of targeted viral RNA may have contributed to suppression, whereas inclusion of a 3' exon encoding the proapoptotic protein &#x394;N-Bax was associated with increased programmed cell death and may have augmented suppression of viral replication. In cultured CEM-A cells, transgene expression of these introns markedly suppressed HIV-1 replication, with p24 levels falling below the assay detection limit in selected clones. RESULTS: RT-PCR and sequence analysis detected splice products containing the expected PAS/PBS junctions. In the dual-luciferase assay, intron expression reduced normalized Gaussia luciferase signal by approximately 70% relative to the negative control. Qualitative Annexin V imaging and caspase-3 assays were consistent with infection-dependent apoptosis after &#x394;N-Bax splice-product formation. Transient expression of each intron in HEK293T cells followed by infection with VSV-G-pseudotyped HIV-1NL4-3&#x202f;at an MOI of 2 reduced p24 levels by approximately 50% at 4 days post-infection. Construct 128L produced the strongest RT-PCR band under the tested conditions and was selected for subsequent experiments. A canonical splice product and a low-abundance noncanonical splice product were detected; both involved the intended HIV-derived target RNA, although transcriptome-wide off-target splicing was not assessed. Heterogeneous transformed HEK293T populations showed an approximately 2-log10 reduction in p24. In selected clonal HEK293T and CEM-A lines, p24 was below the assay detection limit at the measured endpoints, including up to 90 days after infection in some CEM-A clones. CONCLUSIONS: PAS/PBS-targeting group I introns suppressed HIV-1-associated p24 production in the tested cell-culture models. Linking the introns to a &#x394;N-Bax 3' exon was associated with infection-dependent apoptosis and may further limit viral replication and spread. The use of highly conserved, functionally constrained target sequences may reduce the likelihood of escape, but viral evolution and transcriptome-wide off-target effects were not assessed. This conditional death-upon-infection strategy warrants further evaluation in primary-cell and in vivo models.

Humans