Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “extreme rays”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Development of a new state-of-the-art beamline optimized for monochromatic single-crystal and powder X-ray diffraction under extreme conditions at the ESRF.

A new state-of-the art synchrotron beamline fully optimized for monochromatic X-ray diffraction at high pressure and high (or low) temperature is presented. In comparison with the old high-pressure beamline ID30, this new beamline exhibits outstanding performance in terms of photon flux and focusing capabilities. The main components of this new instrument will be described in detail and compared with the performance of beamline ID30. In particular, the choices in terms of X-ray source, X-ray optics, sample environment and detectors are discussed. The first results of the beamline commissioning are presented.

Journal Article↗

Dose reduction in the low-energy X-ray diagnostics of extremities.

The authors determined the surface absorbed dose (Ds = 67-68 mGy) and the average absorbed dose (Dav = 13-15 mGy) by means of non-screen film radiography of the extremities. The authors recommend the use of xeroradiography (with a tungsten anode tube) or, first of all, a rare-earth screen - film combination (e.g. Kodak min-R + Nuklearmedizin NMB film). The two methods permit the dose values to be decreased by a factor of about 4 and 15, respectively. The dose values are smaller, at least for the 8 cm thick tissue equivalent phantom, when a tungsten anode is used instead of a Mo anode.

Extremities↗

Diagnostic accuracy of lower extremity X-ray interpretation by 'specialized' emergency nurses.

OBJECTIVES: In the quest for a cost-effective and quality-preserving solution to manage crowding in the emergency department, the possibility of deploying regular emergency nurses for the treatment of acute ankle injuries was investigated. The aim of this study is to compare the diagnostic accuracy of emergency nurses with that of senior house officers in interpreting ankle and foot radiographs. METHODS: A prospective study comparing the assessment of 60 radiographs (30 feet and 30 ankles) by 16 emergency nurses before and after an educational session was performed. Each subset of 30 radiographs contained 12 fractures, hand-picked by a radiologist to represent everyday traumatology in the emergency department. The control group consisted of eight senior house officers representing everyday expertise. The outcome of the diagnostic assessment, represented as the pooled sensitivity and specificity for both groups, was compared using Z-statistics. RESULTS: Before the training session, the specialized emergency nurse group showed a sensitivity of 0.87 (confidence interval 0.83-0.91) compared with 0.93 (confidence interval 0.88-0.96) for the control group (P = 0.05). The specificity of specialized emergency nurses was 0.87 (confidence interval 0.81-0.92) compared with 0.93 (confidence interval 0.89-0.95) for the senior house officers (P < 0.05). After the training session, specialized emergency nurse diagnostic parameters did not differ significantly from the control group, displaying a sensitivity of 0.89 (confidence interval 0.86-0.92) and specificity of 0.92 (confidence interval 0.87-0.95). CONCLUSION: Before the training session, the specialized emergency nurse group showed a significantly lower accuracy than the SHO group. After training, however, the diagnostic accuracy did not differ significantly between groups. Therefore, we conclude that emergency nurses are able to accurately interpret foot and ankle radiographs after a short educational session.

Adult↗

Achromatic Fresnel optics for wideband extreme-ultraviolet and X-ray imaging.

Advances in extreme-ultraviolet (EUV) and X-ray optics are providing powerful new capabilities in high-resolution imaging and trace-element analysis of microscopic specimens, and the potential for fabricating devices of smaller critical dimensions in next-generation integrated circuit lithography. However, achieving the highest resolution with such optics usually requires the illuminating EUV or X-ray beam to be highly monochromatic. It would therefore be highly desirable to have large-field-of-view, sub-100-nm resolution optics that are achromatic to a significant degree, allowing more light to be utilized from broader bandwidth sources such as laser-produced plasmas. Here we report an achromatic Fresnel optical system for EUV or X-ray radiation that combines a Fresnel zone plate with a refractive lens with opposite chromatic aberration. We use the large anomalous dispersion property of the refractive lens material near an absorption edge to make its fabrication practical. The resulting structure can deliver a resolution comparable to that of the Fresnel zone plates that have achieved the highest resolution (25 nm; ref. 3) in the entire electromagnetic spectrum, but with an improvement of two or more orders of magnitude in spectral bandwidth.

Journal Article↗

Precision of dual energy x-ray absorptiometry in the upper extremities.

Dual energy x-ray absorptiometry (DEXA) has been shown to be a precise method for measuring bone mineral density (BMD) and content (BMC) in lumbar spine and proximal femur, but it has not been widely used in other skeletal sites. The in vivo day-to-day precision of DEXA (Norland XR-26) for seven anatomic sites in the upper extremities was evaluated by twice measuring both the right and left sides in ten subjects. For consistently defined regions-of-interest, the following precision values (coefficient of variation) were obtained for BMD and BMC: 0.8% and 1.0% (proximal humerus); 0.5% and 0.5% (humeral shaft); 0.7% and 0.5% (radial shaft); 1.3% and 1.1% (ulnar shaft); 0.7% and 1.0% (distal radius); 0.7% and 1.2% (distal ulna); 0.4% and 0.6% (hand). The initially observed relative side-to-side differences did not change significantly in the repeated measurements. Our results indicate that DEXA is a precise method for assessment of BMD and BMC also in the upper extremities.

Absorptiometry, Photon↗

Comparison of two-dimensional MR digital subtraction angiography of the lower extremity with x-ray angiography.

PURPOSE: To perform a preliminary evaluation of the diagnostic accuracy of contrast-enhanced, two-dimensional (2D) magnetic resonance (MR) digital subtraction angiography (DSA) of the lower extremity by comparison with x-ray angiography (XRA). MATERIALS AND METHODS: Forty lower extremities in 22 patients were imaged at multiple levels with both XRA and 2D MR DSA. Images were retrospectively analyzed by three radiologists in a randomized blinded manner. Seventeen vascular segments were graded as an insignificant lesion, a significant lesion, or as an occlusion. With the use of segments well depicted with XRA as the gold standard, the sensitivity, specificity, and accuracy of 2D MR DSA, as compared with XRA, were evaluated. The McNemar-Stuart-Maxwell test was performed to determine the significance of any differences found. RESULTS: Three hundred eighty-three arterial segments were evaluated with both techniques. Three hundred one segments were well depicted with XRA. There was no significant difference between 2D MR DSA and XRA for assessing the degree of occlusive disease in these 301 segments (.25 < P < .5). The sensitivity, specificity, and diagnostic accuracy of 2D MR DSA were found to be 90%, 98%, and 93%, respectively. CONCLUSION: Two-dimensional MR DSA is an accurate method for assessing arterial lesions in the lower extremity.

Adult↗

Ultrahigh-energy cosmic rays: physics and astrophysics at extreme energies.

The origin of cosmic rays is one of the major unresolved questions in astrophysics. In particular, the highest energy cosmic rays observed have macroscopic energies up to several 10(20) electron volts and thus provide a probe of physics and astrophysics at energies unattained in laboratory experiments. Theoretical explanations range from astrophysical acceleration of charged particles, to particle physics beyond the established standard model, and processes taking place at the earliest moments of our universe. Distinguishing between these scenarios requires detectors with effective areas in the 1000-square-kilometer range, which are now under construction or in the planning stage. Close connections with gamma-ray and neutrino astrophysics add to the interdisciplinary character of this field.

Journal Article↗

Using the Internet for rapid exchange of photographs and X-ray images to evaluate potential extremity replantation candidates.

OBJECTIVE: To implement a low-cost system of transmitting high-quality digital photographs of mutilating extremity injuries using the speed of the Internet. DESIGN: A high-resolution digital camera and simple hardware and software platform are used to take and transmit images via electronic mail. The images are received within minutes by the consultant, and an assessment can be made. RESULTS: A low-cost and high-quality system can easily be implemented. Images can be seen by consultants only a few minutes after they are obtained. The quality of the reproductions is excellent, and they are handled exactly as other photographs. CONCLUSION: This technique can be widely applicable and inexpensive to initiate in any emergency room. It allows rapid assessment of extremity injuries and x-ray images by expert consultants, who can then evaluate the replantation or revascularization potential of extremity trauma cases. This can eliminate unnecessary and often expensive transfer of patients who are not candidates for replantation.

Adult↗

A protocol for selecting patients with injured extremities who need x-rays.

To help curb excessive radiography, we developed a protocol for selecting patients with injured extremities who need x-ray examination, and we tested the protocol prospectively in 848 patients to determine its safety and effectiveness. Strict adherence to the protocol would have reduced x-ray usage by 12 per cent for upper extremities and 19 per cent for lower extremities. The actual reductions were 5 per cent and 16 per cent, respectively, since further reductions were limited by patient's demands for x-ray examinations. One fracture in 287 were missed, but the treatment was appropriate and the outcome satisfactory. By eliminating superfluous x-ray procedures, the protocol could reduce charges by $79 million to $139 million nationwide, without compromising quality of care or increasing malpractice liability. Nevertheless, even the best protocol cannot eliminate all negative x-ray studies. These results should serve as a stimulus for judicious use of radiography, but also as a warning to avoid overzealous cost-containment strategies that would reduce x-ray usage to below a safe threshold.

Connecticut↗

How surgeon age affects surveillance strategies for extremity soft tissue sarcoma patients after potentially curative treatment.

BACKGROUND: The optimal strategy for follow-up of extremity soft tissue sarcoma patients after potentially curative treatment remains unknown. We investigated whether the date of completion of formal surgical training affects choice of surveillance strategy. MATERIALS AND METHODS: The 1,592 members of the Society of Surgical Oncology were asked how often they use 12 separate surveillance modalities during years 1-5 and 10 postsurgery. The motivation underlying follow-up was assessed separately. Repeated-measures analysis of variance was used to compare practice patterns by the year in which the surgeon's formal surgery training was completed, controlling for tumor grade, tumor size, and year postsurgery. RESULTS: Of the 716 respondents, 318 performed surgery and also provided long-term postoperative surveillance for their patients. These respondents were considered evaluable. Erythrocyte sedimentation rate, extremity X ray, and bone scan were the follow-up tests which differed significantly among physician age groups. Surgeons who completed training more than 30 years ago ordered erythrocyte sedimentation rate more frequently (P < 0.001). Surgeons in the 21-30 year category ordered extremity X ray and bone scan more frequently (P < 0.05), but the absolute differences among age groups were quite small. Older surgeons were also significantly more likely to believe that follow-up is clinically worthwhile. CONCLUSIONS: The posttreatment surveillance practice patterns of the members of the Society of Surgical Oncology caring for extremity soft tissue sarcoma patients vary only marginally with the length of time since completion of training. Postgraduate education may be one factor homogenizing surgeon behavior in this important aspect of cancer patient care.

Aging↗