Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Comparison of diagnostic performance with ventilation-perfusion lung imaging in different patient populations.

PURPOSE: To determine if patient age, chest radiographic abnormalities, or history of cardiopulmonary disease or venous thromboembolism affected diagnostic performance with ventilation-perfusion (V-P) imaging. MATERIALS AND METHODS: Receiver operating characteristic (ROC) analyses were performed on the final V-P imaging interpretation data obtained during the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study. Diagnostic performance with V-P imaging was not substantially different in patients with varying ages, an abnormal chest radiograph, or a history of venous thromboembolism or cardiopulmonary disease. CONCLUSION: Because diagnostic performance with V-P imaging in detection of pulmonary embolism was similar among the patient populations examined, an abnormal chest radiograph or history of venous thromboembolism or cardiopulmonary disease does not appear to adversely affect overall diagnostic performance in evaluation of acute pulmonary embolism.

Adult↗

Perianal infections: reader agreement and diagnostic performance of fat-suppressed contrast-enhanced MRI.

We aimed to determine the diagnostic performance of the contrast-enhanced fat-suppression technique in the detectability of perianal infections and to compare this technique with different MR sequences used for this purpose. Thirty consecutive patients with clinically suspected anorectal infections were examined with fast spin-echo (FSE) T2-weighted, short-inversion-time inversion recovery (STIR), and fat-suppressed and non-fat-suppressed T1-weighted spoiled gradient-echo (SGE) (in-phase) dynamic contrast-enhanced sequences. The results of MRI were correlated with the findings of surgery, which was considered as the standard of reference. Receiver-operating-characteristic curves were reconstructed to describe and compare the diagnostic value of each MR technique. The values of kappa were used as a measure of observer reliability. Diagnostic performances of STIR, FSE T2-weighted and fat-suppressed and non-fat-suppressed, contrast-enhanced SGE T1-weighted techniques showed statistically insignificant differences in detection of perianal infections. There was almost perfect interobserver agreement regarding the presence of lesions on each MR technique. Fat-suppressed, contrast-enhanced SGE T1-weighted MRI showed adequate diagnostic performance in the detection of perianal infections. However, its significance is not different from the other MR sequences used for the present study.

Adult↗

Diagnostic performance of general dental practitioners after lecture in identifying post-menopausal women with low bone mineral density by panoramic radiographs.

OBJECTIVES: Mandibular cortical erosion detected on panoramic radiographs may be useful for identifying post-menopausal women with low skeletal bone mineral density (BMD). The purposes of this study were to calculate the diagnostic performance of general dental practitioners (GDPs) who attended a lecture on identifying post-menopausal women with low BMD from findings on panoramic radiographs and to evaluate the influence of GDPs' age on diagnostic performance. METHODS: After a 1 h lecture, 111 GDPs were asked to classify the mandibular cortex (normal or eroded) on panoramic radiographs obtained from 100 post-menopausal women who have had skeletal BMD assessment. Low BMD was defined as a BMD T score of -1.0 or less. Diagnostic performance was analysed by comparing two groups classified by mandibular cortex (women with normal cortex and women with any eroded cortex) with those classified by BMD (women with normal BMD and women with low BMD). RESULTS: The mean sensitivity, specificity, positive predictive value, negative predictive value, accuracy and likelihood ratio for a positive risk result were 73.0% (95% confidence interval [CI]; 71.3 to 74.7%), 49.0% (95% CI; 46.4 to 51.5%), 66.9% (95% CI; 66.0 to 67.8%), 57.0% (95% CI; 55.8 to 58.2%), 62.9% (95% CI; 62.1 to 63.7%) and 1.51 (95% CI; 1.44 to 1.58), respectively. GDPs' age did not influence diagnostic performance. CONCLUSIONS: Our results suggest that 73.0% of women who had low skeletal BMD can be identified by GDPs after a lecture on the use of panoramic radiographs as an aid in diagnosing low BMD; however, the diagnostic performance may not be influenced by GDPs' age.

Adult↗

Effect of lesion size on the diagnostic performance of dermoscopy in melanoma detection.

BACKGROUND: Dermoscopy is able to correctly classify a higher number of melanomas than naked-eye examination. Little is known however about factors which may influence the diagnostic performance during practice. The aim of the study was to analyze the effect of size of the lesion on diagnostic performance of dermoscopy in melanoma detection. METHODS: Eight dermatologists examined clinical and, separately, clinical and dermoscopic (combined examination) images of 200 melanocytic lesions previously excised [64 melanomas, 24 in situ and 40 invasive (median thickness 0.30 mm) and 136 melanocytic nevi]. After examination, diagnostic performance was analyzed in accordance with the major diameter of the lesions divided into 3 groups, i.e. small (less than 6 mm), intermediate (between 6 and 9 mm) and large (10 mm or more) lesions. These groups were shown to be highly comparable concerning the microstaging of melanomas (median thickness value 0.30, 0.22 and 0.32 mm, respectively). RESULTS: Dermoscopy increased the diagnostic performance of naked-eye examination of both intermediate and large lesions [sensitivity value: +19.3 (p = 0.002) and +10.3 (p = 0.007); diagnostic accuracy value: +7.4 (p = 0.004) and +6.1 (p = 0.07)]. On the contrary, no statistically significant increase was found dealing with small lesions (sensitivity +3.7, p = 0.66; diagnostic accuracy -1.7, p = 0.55). CONCLUSIONS: The diagnostic improvement associated with the addition of dermoscopy to naked-eye examination is influenced by the size of the lesion, i.e. it is lacking with lesions up to 6 mm in diameter. The optimized use of dermoscopy in melanoma detection is obtained dealing with melanocytic lesions 6 mm in diameter or larger.

Humans↗

Characterization of small focal liver lesions using real-time contrast-enhanced sonography: diagnostic performance analysis in 200 patients.

OBJECTIVE: The purpose of this study was to assess the diagnostic performance of real-time contrast-enhanced sonography in characterization of small focal liver lesions (FLLs; < or = 3.0 cm in diameter). METHODS: Two hundred small FLLs in 200 patients were examined by contrast-enhanced sonography using a contrast-specific mode of contrast pulse sequencing and a sulfur hexafluoride-filled microbubble contrast agent. The sonographic images were reviewed by 2 independent readers. A 5-point confidence level was used to discriminate malignant from benign FLLs, and specific diagnoses were recorded. The diagnostic performances were evaluated by receiver operating characteristic (ROC) analysis, and the interobserver agreement was analyzed by weighted kappa statistics. RESULTS: After review of contrast-enhanced sonography, ROC analysis revealed significant improvement in differentiating between malignant and benign small FLLs that the areas under the ROC curve were 0.856 at baseline sonography versus 0.954 at contrast-enhanced sonography for reader 1 (P < .001) and 0.857 versus 0.954 for reader 2 (P = .003). The sensitivity, negative predictive value, and accuracy for both readers also improved significantly after contrast agent administration (all P < .001). A better result of specific diagnosis was obtained (38.5% [77/200] at baseline sonography versus 80.5% [161/200] at contrast-enhanced sonography for reader 1 and 34.5% [69/200] versus 80.5% [161/200] for reader 2; both P < .001) after contrast agent administration, and a better interobserver agreement was achieved (kappa = 0.425 at baseline sonography versus 0.716 at contrast-enhanced sonography). CONCLUSIONS: Real-time contrast-enhanced sonography improves the diagnostic performance in small FLLs compared with baseline sonography.

Adult↗

A beneficial effect of a short-term formal training course in epiluminescence microscopy on the diagnostic performance of dermatologists about cutaneous malignant melanoma.

BACKGROUND: Epiluminescence microscopy (ELM) is a useful tool, which, in the hands of experienced dermatologists successfully helps in the diagnosis of early cutaneous malignant melanoma (CMM). As all imaging diagnostic methods, ELM also requires preliminary training of the physicians. OBJECTIVE: The aim of the study was to evaluate a possible beneficial effect of a short-term formal training course in ELM on the diagnostic performance of dermatologists about CMM. METHODS: The test group consisted of 32 dermatologists. Tests were performed in the beginning and in the end of the teaching course. Every time a total 50 histologically proven pigmented skin lesions (PSLs) photographed without oil immersion-Surface microscopy (SM) and with oil immersion-ELM was presented by slide projection. To assess the effect on the diagnostic performance before and after short- term training the data concerning diagnoses were analysed for the following: sensitivity, specificity, positive predictive value, and negative predictive value, index of suspicion and diagnostic accuracy. RESULTS: Before the training course the implementation of ELM leads to relative increasing of all studied indicators of ELM diagnosis towards SM diagnosis, but differences are not statistically significant (P > 0.05). After the course there is an improvement of diagnostic performance of dermatologists by ELM, manifested by enhancement of all indicators. The changes of the sensitivity, negative predictive value and diagnostic accuracy of ELM diagnosis was statistically significant (P < 0.05). CONCLUSION: The short-term formal course in ELM has a beneficial effect on the diagnostic performance of dermatologists about CMM. The improvement of early detection of CMM requires dermatologists enhanced training and higher qualification in the field of dermoscopy.

Clinical Competence↗

Overestimation of clinical diagnostic performance caused by low necropsy rates.

BACKGROUND: Diagnostic sensitivity is calculated as the number of correct diagnoses divided by the sum of correct diagnoses plus the number of missed or false negative diagnoses. Because missed diagnoses are generally detected during clinical follow up or at necropsy, the low necropsy rates seen in current practice may result in overestimates of diagnostic performance. Using three target conditions (aortic dissection, pulmonary embolism, and active tuberculosis), the prevalence of clinically missed cases among necropsied and non-necropsied deaths was estimated and the impact of low necropsy rates on the apparent sensitivity of antemortem diagnosis determined. METHODS: After reviewing case series for each target condition, the most recent study that included cases first detected at necropsy was selected and the reported sensitivity of clinical diagnosis adjusted by estimating the total number of cases that would have been detected had all decedents undergone necropsy. These estimates were based on available data for necropsy rates, time period, country (US v non-US), and case mix. RESULTS: For all three target diagnoses, adjusting for the estimated prevalence of clinically missed cases among non-necropsied deaths produced sensitivity values outside the 95% confidence interval for the originally reported values, and well below sensitivities reported for the diagnostic tests that are usually used to detect these conditions. For active tuberculosis the sensitivity of antemortem diagnosis decreased from an apparent value of 96% to a corrected value of 83%, with a plausible range of 42-91%; for aortic dissection the sensitivity decreased from 86% to 74%; and for pulmonary embolism the reduction fell only modestly from 97% to 91% but was still lower than generally reported values of 98% or more. CONCLUSIONS: Failure to adjust for the prevalence of missed cases among non-necropsied deaths may substantially overstate the performance of diagnostic tests and antemortem diagnosis in general, especially for conditions with high early case fatality.

Aortic Dissection↗

The diagnostic performance of cytogenetic investigation in amniotic fluid cells and chorionic villi.

First-trimester chorionic villus sampling has not reached the popularity of second-trimester amniocentesis in prenatal cytogenetic diagnosis, in contrast to initial expectations. We investigated whether a difference in the diagnostic performances of cytogenetic investigation in amniotic fluid (AF) cells and chorionic villi in favour of AF-cells might justify this. Diagnostic performance was measured as laboratory failure rate, karyotype quality (G-band score, rate of follow-up samples, rate of wrong diagnoses), and karyotype representativity (rate of follow-up samples, rate of wrong diagnoses). From 1993-1999, 11 883 AF-samples were investigated (AF-cells). In chorionic villi, short term culture preparations solely were karyotyped from 1993-1996 (n=3499) (STC-villi), short and long-term culture preparations simultaneously provided a sufficient amount of tissue being available from 1997 onwards (n=1829) ((STC+LTC)-villi). Laboratory failure rates were the same after amniocentesis (0.40%) and chorionic villus sampling (0.50%). G-band scores (mean+/-SD) were equal in AF-cells (373+/-38.1) and LTC-villi (364+/-32.6) but significantly lower in STC-villi (311+/-34.6) (p=0.001). Follow-up sampling rates because of quality reasons were the same in AF-cells (0.14%), STC- villi (0.13%) and (STC+LTC)-villi (0.11%). Two wrong diagnoses turned up among AF-cells. Follow-up sampling rates because of representativity reasons differed significantly between AF-cells (0.10%), (STC+LTC)-villi (1.31%), and STC-villi (1.99%) (p<0.001). However, the ratios of the total numbers of follow-up samples and uncertain or abnormal cytogenetic results in STC, and (STC+LTC)-villi at cytogenetic risks > or =3% (0.132 and 0.160, respectively) were equal to that in AF-cells at risks <3% (0.155). Two wrong diagnoses were made in STC-villi. Diagnostic performance improved in the rank order of STC-villi, (STC+LTC)-villi and AF-cells. At cytogenetic risks > or =3%, (STC+LTC)-villi showed a diagnostic performance equal to that in AF-cells. This might justify a selective use of chorionic villus sampling.

Amniocentesis↗

A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancer.

Transrectal ultrasound (TRUS) is an important tool for urologists and radiologists in the detection of prostate cancer. Various TRUS-guided biopsy techniques are applied in clinical practice. Frequently, only the detection rates achieved with these methods are compared. Other diagnostic performance parameters, particularly the specificity and negative predictive value, are seldom compared. After extensive assessment of the available literature, this review describes the methods of TRUS-guided biopsy for prostate cancer detection. A distinction was made between systematic biopsies and biopsies that target a perceived (hypoechoic or Doppler-enhancing) lesion on imaging. Subsequently, the diagnostic performance (sensitivity, specificity, positive and negative predictive values, accuracies) was compared between these techniques. Imaging-guided biopsy showed better diagnostic performance than systematic biopsy with higher sensitivity. The combinations of sensitivity and specificity were highest for colour Doppler and contrast-enhanced targeted biopsy. Studies targeting hypoechoic lesions had relatively high sensitivity, but specificity was low. Presently however, with widespread prostate-specific antigen screening, fewer prostate cancers are hypoechoic, and the value of targeting hypoechoic lesions has diminished. Performing colour or contrast-enhanced Doppler biopsy or adding these techniques to systematic biopsies improves diagnostic performance, particularly by increasing sensitivity.

Biopsy↗

Effect of dose levels on the diagnostic performance of a selenium-based digital chest system.

RATIONALE AND OBJECTIVES: To evaluate the effect of dose reduction on diagnostic performance by using a digital chest imaging system in which amorphous selenium serves as the x-ray detector. METHODS: Two hundred forty-seven patients were examined with the selenium system. Three sets of images were made in each patient: one set with a standard x-ray dose, one set with 55% of the standard dose, and one set with 35% of the standard dose. All 741 images were read by two radiologists. The diagnostic value of each set of images for detection of pulmonary, mediastinal, and pleural pathology was analyzed with receiver operating characteristic (ROC) methodology by using computed tomography as the reference standard. The authors also assessed the effect of sex, height, and weight of the patients on the diagnostic performance of the readers. RESULTS: The areas under the ROC curves for the detection of various abnormalities at 100%, 55%, and 35% of the standard dose for observer 1, respectively, were pulmonary opacities 0.82, 0.83, 0.84; interstitial disease 0.71, 0.70, 0.72; mediastinal disease 0.81, 0.80, 0.77; and pleural abnormalities 0.71, 0.72, 0.72. There were no statistically significant differences between the two observers. CONCLUSIONS: No statistically significant difference was found between the radiologists' performance in detecting abnormalities with standard x-ray dose images and the performance with images made with 55% and 35% of the standard dose. Sex, height, and weight had no influence on diagnostic performance.

Area Under Curve↗

The diagnostic performance of a PC-based teleradiology link.

AIM: Evaluation of the diagnostic performance of a personal computer based teleradiology link. MATERIALS AND METHODS: Two experienced radiologists assessed 100 cases, all based on chest and skeletal films using teleradiology for 50. These assessments were compared with the consensus of a panel of three independent radiologists. RESULTS: Diagnostic performance of teleradiology and conventional film was similar (sensitivity 88 vs. 90%; specificity 96 vs. 90%; accuracy 91 vs. 90%; not significant). However, the quality of teleradiology images was rated poorer, and the confidence in diagnosis was lower with teleradiology. ROC curve analysis, taking into account diagnostic confidence, showed significantly poorer performance for teleradiology at all thresholds when chest X-rays only were considered. There was no significant difference for skeletal images, although the two smooth curves crossed, suggesting teleradiology might be better when the specificity is high. CONCLUSION: These findings suggest that when this type of teleradiology system is used, the value of rapid reporting must be balanced against poorer image quality, particularly for chest X-rays.

Bone and Bones↗

A traditionally administered short course failed to improve medical students' diagnostic performance. A quantitative evaluation of diagnostic thinking.

BACKGROUND: Quite often medical students or novice residents have difficulty in ruling out diseases even though they are quite unlikely and, due to this difficulty, such students and novice residents unnecessarily repeat laboratory or imaging tests. OBJECTIVE: To explore whether or not a carefully designed short training course teaching Bayesian probabilistic thinking improves the diagnostic ability of medical students. PARTICIPANTS AND METHODS: Ninety students at 2 medical schools were presented with clinical scenarios of coronary artery disease corresponding to high, low, and intermediate pretest probabilities. The students' estimates of test characteristics of exercise stress test, and pretest and posttest probability for each scenario were evaluated before and after the short course. RESULTS: The pretest probability estimates by the students, as well as their proficiency in applying Bayes's theorem, were improved in the high pretest probability scenario after the short course. However, estimates of pretest probability in the low pretest probability scenario, and their proficiency in applying Bayes's theorem in the intermediate and low pretest probability scenarios, showed essentially no improvement. CONCLUSION: A carefully designed, but traditionally administered, short course could not improve the students' abilities in estimating pretest probability in a low pretest probability setting, and subsequently students remained incompetent in ruling out disease. We need to develop educational methods that cultivate a well-balanced clinical sense to enable students to choose a suitable diagnostic strategy as needed in a clinical setting without being one-sided to the "rule-in conscious paradigm."

Adult↗

Voxel-based morphometric comparison between early- and late-onset mild Alzheimer's disease and assessment of diagnostic performance of z score images.

BACKGROUND AND PURPOSE: Voxel-based morphometry (VBM), used for detecting brain atrophy, permits comparison of local gray matter concentration at every voxel in an image between two groups. We sought to delineate the specific patterns of cerebral gray matter loss with regard to onset of Alzheimer's disease (AD) by using MR imaging and VBM and to evaluate the diagnostic performance of VBM with Z score images. METHODS: Two groups of 30 patients with mild AD of different ages of onset were examined. Mean ages in the early- and late-onset groups were 60.2 +/- 5.2 and 71.5 +/- 2.6 years, respectively. Control subjects were aged-matched healthy volunteers. Regions of gray matter loss in early- and late-onset AD were examined with VBM. Diagnostic performance of Z score images obtained with the VBM method was evaluated in patients and control subjects by calculating the area under the receiver operating characteristic curve (A(z)). RESULTS: Both AD groups had significantly reduced gray matter in the bilateral medial temporal regions. In addition, the early-onset group had more severe gray matter loss in the bilateral parietal and posterior cingulate cortices and precuneus region. No difference was noted in diagnostic performance of Z score images between the early- (A(z) = 0.9435) and late-onset (A(z) = 0.9018) groups. CONCLUSION: Differences were noted in the patterns of regional gray matter loss in patients with early-onset AD versus those with late-onset AD. Parietotemporal and posterior cingulate gray matter loss was found in early-onset AD but not in late-onset AD. Z score images obtained with VBM had a great diagnostic performance for mild AD and can be applied for detecting mild AD in clinical examinations.

Aged↗

Comparison of diagnostic performance of unenhanced vs SonoVue - enhanced ultrasonography in focal liver lesions characterization. The experience of three Italian centers.

PURPOSE: To evaluate the diagnostic performance of contrast-enhanced US with SonoVue (Bracco, Milan, Italy) compared to baseline US in focal hepatic lesions characterization. MATERIALS AND METHODS: A comprehensive number of four operators from 3 hospitals evaluated 57 consecutive patients with 60 focal hepatic lesions (28 hepatocellular carcinomas, 11 metastases, 13 hemangiomas, 1 hepatocellular adenoma and 7 focal nodular hyperplasias) by baseline gray-scale ultrasound (US) and color Doppler US. The same lesions were subsequently scanned by contrast-enhanced US after intravenous bolus administration of 2,4-4,8 ml of SonoVue by employing intermittent high or continuous low transmit power imaging. The diagnosis of lesions nature (benign or malignant) and histotype proposed by the on-site operator was finally compared to the definite diagnosis reached by reference procedures (multiphasic contrast-material enhanced helical-computed tomography or magnetic resonance in 24 lesions and fine needle US guided biopsy in 36 lesions). Diagnostic performance (sensitivity, specificity and overall accuracy expressed by the agreement with the reference procedures) of baseline and contrast enhanced US were compared. RESULTS: Differences in sensitivity (baseline vs contrast-enhanced US: 13/39 [33%] vs 32/39 [82%]), specificity (baseline vs contrast-enhanced US: 12/21 [57%] vs 16/21 [76%]) and overall accuracy (baseline vs contrast-enhanced US: 25/60 [41%] vs 47/60 [78%]) were significant (p<0.05; McNemar test). CONCLUSIONS: SonoVue-enhanced US determined a significant improvement in diagnostic performance in the characterization of focal liver lesions if compared to baseline US.

Adenoma, Liver Cell↗

High-resolution magnetic resonance cholangiography (MRC) with adaptive averaging: diagnostic performance evaluation.

AIM: To evaluate the diagnostic performance of an interactive, adaptively averaged (AA) two-dimensional (2D) magnetic resonance cholangiography (MRC) technique in patients with suspected biliary disease by comparison to the standard MRC technique. MATERIALS AND METHODS: The AA 2D MRC method registers the images after acquisition, allowing summation of multiple images to improve the signal:noise ratio (SNR) and thereby potentially improve the visualization of bile ducts. One hundred and twenty-eight patients underwent both 2D conventional and AA magnetic resonance cholangiopancreatography (MRCP). Twenty-seven patients were excluded from the analysis as AA images could not be properly obtained due to technical failures. All examinations were performed using a 1.5 T whole-body MR system and a four-channel torso phased array coil. Images of 101 patients were adaptively averaged using an in-house developed program written in IDL. Two readers qualitatively evaluated the studies in consensus, blinded to acquisition details and without knowledge of clinical information. RESULTS: The AA technique was significantly better than the conventional 2D MRC for the visualization of the second-order branch intrahepatic ducts (p<00001). Overall, there was no significant difference in the diagnostic confidence between two techniques (p=0.12). However, the AA technique showed a trend towards more confident diagnosis of biliary strictures (p=0.055), likely due to better diagnostic confidence in identifying second order branch intrahepatic duct strictures (p=0.054). CONCLUSION: Excluding those patients those patients in whom either satisfactory respiratory gating or a suitable kernel placement was not achieved, AA 2D MRC demonstrated a significant improvement in visualization of intrahepatic duct branches compared to standard MRC.

Adolescent↗

High resolution MRI of small joints: impact of spatial resolution on diagnostic performance and SNR.

This study focuses on the spatial resolution required for cartilage imaging. The purposes of this study were (I) to analyze the diagnostic performance in diagnosing artificially produced cartilage lesions in a small joint model using an optimized fat saturated three-dimensional gradient-echo sequence, (II) to relate the lesion size and depth as diagnosed in the magnetic resonance images with the corresponding pathologic findings and (III) to assess signal-to-noise (SNR) ratios for each of the protocols. Twenty-five artificial cartilage lesions were created in the knee joints of 10 rabbits. These specimens and seven specimens without lesions were imaged at 1.5 T using a three-dimensional gradient-echo sequence with varying slice thickness, field of view and matrix. A total of 404 corresponding images were selected, 50% with and 50% without cartilage lesions. Six radiologists scored all images according to five levels of confidence and receiver operating characteristic (ROC) analysis was performed. Lesion size and depth were compared to the corresponding pathological specimen sections. Additionally SNR ratios were calculated. ROC analysis of pooled data from all readers showed the highest area under the ROC curve for the sequence with the highest spatial resolution, while the diagnostic performance was significantly lower in the other sequences (p <0.01). Assessment of the lesion size and depth was correct in 45% and 40% respectively with the highest resolution and in 29% and 23% with the lowest resolution. SNR ratios decreased with increasing spatial resolution. In conclusion this study shows that increasing spatial resolution improves diagnostic performance in cartilage lesions, though SNR decreases substantially. Assessment of correct lesion size and depth still is limited.

Animals↗

Diagnostic performance of the CBCL-Attention Problem Scale as a screening measure in a sample of Brazilian children with ADHD.

OBJECTIVE: To evaluate the diagnostic performance of the Attention Problem Scale of the Child Behavior Checklist (CBCL-APS) for the screening of Attention-Deficit/Hyperactivity Disorder (ADHD) in a sample of Brazilian children and adolescents. METHODS: The CBCL-APS was given to 763 children and adolescents. Child psychiatrists using DSM-IV criteria confirmed the clinical diagnoses. Diagnostic performance was evaluated through Receiver-Operating Characteristic (ROC) curves. RESULTS: Only moderate areas under the curve (AUC) were found for the general sample (AUC = 0.79; 95% CI = 0.76-0.82), and for the subsample of referred patients (AUC = 0.78; 95% CI = 0.74-0.82). The subsample of patients with ADHD of the combined type presented the largest AUC (AUC = 0.85; 95% CI = 0.82-0.88). CONCLUSION: Our findings concur with previous studies of different cultures demonstrating adequate diagnostic performance of the CBCL-APS for the screening of ADHD, especially of the combined type.

Adolescent↗

Diagnostic performance of biopsy-based methods for determination of Helicobacter pylori infection without a reference standard.

Endoscopic biopsy-based tests are considered to be the reference method for diagnosing Helicobacter pylori infection and monitoring antibiotic treatment, but unbiased data on their diagnostic performance is lacking. In this study we evaluated the diagnostic performance of culture, histology and rapid urease testing of antral biopsies separately and in combination. Antral biopsies were taken from consecutive patients undergoing upper gastrointestinal endoscopies at a single center between January 1995 and May 1997. The biopsies were examined for culture, histology, and CLOtest. The diagnostic performance, i.e., the sensitivity and specificity of the tests was estimated with 7 non-linear equations in 7 unknowns. To determine sources of heterogeneity that may have biased the results, data were stratified for age, gender, and whether they were taken before or after anti-Helicobacter antibiotic treatment. During the study period 631 patients underwent 869 upper gastrointestinal endoscopies. In 122 (14%) of the antral specimens the test results of culture, histology and CLOtest differed. Based on the nonlinear regression techniques we estimated that in 347 tests (40%) H. pylori infection was present. Overall sensitivity, specificity, positive and negative predictive value for each test were as follows: culture 91.4%, 96.3%, 94.2%, 94.4%, respectively; histology 90.3%, 97.8%, 96.4%, 93.8%, respectively; CLOtest 94.9%, 96.7%, 95.0%, 96.6%, respectively. In combination, the three tests provided the definitive diagnosis, either non-infected or infected, in 862 out of the 869 tests. Sensitivity of gastric antral histology was 64.9% (95% CI: 38-86) in females who did and 84.5% (95% CI: 77-90) in females who did not have had recent antibiotic therapy to cure the infection. Approximately 5-10% of H. pylori infected patients, were mis-diagnosed with a single biopsy-based test taken from the gastric antrum. Only a combination of bacterial culture, histological examination and the CLOtest represents an appropriate reference standard for research purposes to identify infected patients.

Adult↗