Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biosensing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Micro- and nanobiotechnology for biosensing cellular responses.

Cells represent the minimum functional and integrating communicable unit of living systems. Cultured cells both transduce and transmit a variety of chemical and physical signals, i.e., production of specific substances and proteins, throughout their life cycle within specific tissues and organs. Such cellular responses might be usefully employed as parameters to obtain chemical information for both pharmaceutical and chemical safety, and drug efficacy profiles in vitro as a screening tool. However, such cellular signals are very weak and not easily detected with conventional analytical methods. By using micro- and nanobiotechnology methods integrated on-chip, a higher sensitivity and signal amplification has been developed for cellular biosensing. Micro- and nanotechnology is rapidly evolving to open new combinations of methods with improved technical performance, helping to resolve challenging bioanalytical problems including sensitivity, signal resolution and specificity by interfacing these technologies in small volumes in order to confirm specific cellular signals. Integration of cell signals in both rapid time and small space, and importantly, between different cell populations (communication and systems modeling) will permit many more valuable measurements of the dynamic aspects of cell responses to various chosen stimuli and their feedback. This represents the future for cell-based biosensing.

Animals↗

Perspectives for microelectrode arrays for biosensing and membrane electroporation.

Electrochemical microelectrode devices are among the great challenges for bioelectrochemistry, cell biology and recently also for biomedical research and new clinical electrotherapies. Two representative cases in cell biology and medical research for new trends in the technical devices are selected, heading at new diagnostic and therapeutic clinical applications. One example is from the field of biosensing cholinergic neurotransmitter substances by the nicotinic acetylcholine receptor (AcChoR) in solid-supported lipid bilayer membrane and the other one refers to new developments of electrode systems for the electrochemical delivery of drugs and genes to biological cell aggregates and tissue by the powerful method of membrane electroporation. In both cases addressed to, the new developments include the use of electrical feedback control of electrode arrays for biosensing processes as well as for the extent and duration of tissue electroporation. In line with the impressive advances in medical microsurgery, where increasingly smaller organ targets become accessible, microelectrode systems have become a continuous technical challenge for bioanalytical purposes and, as discussed here in some detail, for the new field of the electroporative delivery of effector substances like drugs and genes, using miniaturized electrochemical electrode arrays.

Biosensing Techniques↗

Cellular biosensing system for discovery of protein synthesis inhibitors with an electrochemical phosphate modulator to regulate the acid phosphatase gene expression of Saccharomyces cerevisiae.

A cellular biosensing system for screening protein synthesis inhibitors has been developed by linking an electrochemical phosphate modulator and matrix-immobilized yeast cells with an optical sensing device. To screen the protein synthesis inhibitors, yeast phosphatase gene regulating system has been employed by linking an electrochemical phosphate modulator. Since the yeast phosphatase gene coding gammaAPase is expressed, when the phosphate concentration in solution is lowered below the threshold, the gammaAPase production is triggered by lowering the phosphate concentration with the electrochemical phosphate modulator, and monitored continuously with the photometric device. The electrochemical phosphate modulator was assembled with matrix-immobilized yeast cells. The module could insert to ordinal cuvette to monitor the induced gammaAPase activity in an ordinal photometer. Using the system, induction profile of protein synthesis was easily observed and was affected remarkably by various protein synthesis inhibitors. This seems promising that the system can be applied for first screening process of de novo protein inhibitors. The cellular biosensing system seems promising in screening protein synthesis inhibitors.

Acid Phosphatase↗

Thin films of polyelectrolyte-encapsulated catalase microcrystals for biosensing.

Polyelectrolyte (PE)-encapsulated catalase microcrystals were assembled onto gold electrodes by their sequential deposition with oppositely charged PEs, utilizing electrostatic interactions to form enzyme thin films for biosensing. The PE coating around the microcrystals provided a regular surface charge, thus facilitating the stepwise film growth, and it effectively prevented catalase leakage from the assembled films. The encapsulated catalase was shown to retain both its biological and its electrochemical activity. Direct electron transfer between catalase molecules and the gold electrode was achieved without the aid of any electron mediator. In pH 5.0 phosphate buffer solution, the apparent formal potential (E(o)') of catalase was -0.131 V (vs Ag/AgCl). As a H2O2 biosensor, films consisting of one layer of the encapsulated catalase displayed considerably higher (approximately 5-fold) and more stable electrocatalytic responses to the reduction of H2O2 than did corresponding films made of one layer of nonencapsulated catalase or solubilized catalase. An increase in either the number of "precursor" PE layers between the gold electrodes and the catalase microcrystal layers in the film or the number of PE layers encapsulating the catalase microcrystals was found to decrease the electrocatalytic activity of the electrode. At low precursor PE layer numbers (approximately 2) and PE encapsulating layers (approximately 4), the current response was proportional to the H2O2 concentration in the range 3.0 x 10(-6) to 1.0 x 10(-2) M. The overall electroactivity of the multilayer film increased for the first two layers of encapsulated catalase, after which a plateau was observed. This was attributed to the increasing difficulty of electron transfer and substrate diffusion limitations. The current approach of using immobilized PE-encapsulated enzyme microcrystals for biosensing provides a versatile method to prepare high enzyme content films with high and tailored enzyme activities.

Biosensing Techniques↗

Amperometric biosensing systems based on motility and gravitaxis of flagellate algae for aquatic risk assessment.

Electrochemical biosensing systems for toxic substances were developed on the basis of motility and negative gravitaxis of the unicellular flagellate Chlamydomonas reinhardtii. Changes in the flagellar movement of the flagellates in response to three toxic chemicals, toluene, copper(II) sulfate, and nickel(II) chloride, were monitored as changes in the redox currents for a coexisiting redox marker. The gravitaxis-based flagellate biosensing system was more sensitive to toluene than the motility-based system. A thin-layer flagellate biosensor was also developed. In comparison with the conventional algal biosensors monitoring the photosynthetic activity, the gravitaxis-based thin-layer sensor was more sensitive by more than 1 order of magnitude.

Animals↗

Biosensing systems for the detection of bacterial quorum signaling molecules.

Bacterial quorum sensing (QS) is a cell-to-cell communication phenomenon that allows bacteria to control the expression of certain specialized genes depending on their cell population size. Signaling molecules such N-acylhomoserine lactones (AHLs) mediate the communication, and their concentration reflects the bacterial population density. Quorum sensing regulates several processes including bacterial pathogenicity. We developed a method for the rapid, sensitive, and quantitative detection of AHLs in biological samples such as saliva and stools. The method is based on whole-cell sensing systems that employ QS regulatory systems as recognition elements and the luxCDABE gene cassette as a reporter. The method proved to be reproducible when applied to real samples and was able to detect low analyte concentrations down to 1 x 10(-9) M without requiring extensive sample preparation. We envision that this novel biosensing system could be employed in the diagnosis and management of various bacteria-related disorders, thus supporting the use of quorum sensing molecules as potential biomarkers of disease. Due to cost-effectiveness and high throughput, these biosensing systems could be successfully employed as a new tool for the screening of novel drugs that target quorum sensing mechanisms.

Bacteria↗

Computer-controlled laser ablation: a convenient and versatile tool for micropatterning biofunctional synthetic surfaces for applications in biosensing and tissue engineering.

This paper describes laser-based methods for preparing micropatterns of bioactive molecular species in self-assembled monolayers (SAMs) and micropatterns of proteins and other biological molecules immobilized on solid substrates. Applications of these micropatterned surfaces in multianalyte biosensing and tissue engineering are emphasized. The focus of the paper is on the use of a computer-controlled laser ablation system comprising a research-grade inverted optical microscope, a pulsed nitrogen-pumped dye laser emitting at 390 nm, a programmable sample stage, and the computerized control system. The laser system can be implemented in a typical biosensor or tissue culture laboratory to enable the facile and reproducible fabrication of micropatterned surfaces by several methods. Various methods for patterning are discussed with examples given and emphasis placed on (1) laser ablation in the fabrication of photolithography masks, (2) electrochemical patterning of SAMs, and (3) laser desorption of SAMs. The relative merits of each technique are discussed with respect to application in fabrication of active surfaces for biosensing and tissue culture applications.

Biosensing Techniques↗

Electrochemical control of protein monolayers at indium tin oxide surfaces for the reagentless optical biosensing of nitric oxide.

Cytochrome c has been immobilized onto functionalized, optically transparent indium tin oxide (ITO) electrodes by covalent and electrostatic techniques. Covalent immobilization was achieved by the formation of a disulfide bond between N-succinimidyl 3-(2-pyridyldithio)propionate-(SPDP-) modified cytochrome c and SPDP-silanized ITO. Additionally, ITO electrodes have been modified with the bifunctional reagent 1,12-dodecanedicarboxylic acid (DDCA), resulting in formation of a carboxylic acid-terminated monolayer. Covalent protein attachment to the DDCA-functionalized ITO was achieved with the cross-linker 1-[3-(dimethylamino)propyl]-3-ethylcarbodiimide hydrochloride. Electrostatic attachment of the protein involved ion-pair and hydrogen-bond interactions between the terminating carboxylic acid groups of the DDCA-functionalized ITO and the primary amine groups of the lysine residues of cytochrome c. The electrostatic interaction between the cytochrome c and the functionalized ITO resulted in greater rotational mobility of the protein at the electrode surface, leading to ca. 63% electroactivity, as compared to ca. 41% electroactivity for the covalently immobilized protein. The redox state of the electrostatically bound cytochrome c monolayers could be electrochemically switched between ferric and ferrous forms. Electrochemical control of the bound protein was used to regenerate the biosensing surface following binding of nitric oxide (NO). Ligation of NO with the cytochrome c was monitored by measurement of the change of absorbance intensity at 416 nm. Through application of a negative potential, the cytochrome c was reduced from the ferric to the ferrous form, which led to the removal of the ligated NO. Application of a positive potential regenerated the ferric cytochrome c, enabling multiple repeat measurements of NO. Such electrochemical control of proteins immobilized on transparent electrodes enables the optical biosensing of analyte targets without recourse to exogenous reagents.

Animals↗

Electrodes modified with the phase transition polymer and heme peptide: biocatalysis and biosensing with tunable activity and dynamic range.

An electrode was modified with a phase transition polymer, poly(N-isopropylacrylamide), and the polymer was further modified with a peroxidase model compound, heme peptide (HP). As the polymer layer shrank at temperatures above 30-40 degrees C, the catalytic activity of the HP molecules for H(2)O(2) reduction improved, and simultaneously, the number of HP molecules that can communicate electrochemically with the electrode increased. As a result, the catalytic current for H(2)O(2) reduction in the shrunken state was 4 times larger than that in the swollen state. This reversible change was exploited for tuning the sensitivity and dynamic range of the HP electrode in H(2)O(2) biosensing. The dynamic range in inhibition-based biosensing of imidazole derivatives was also tunable.

Acrylic Resins↗

Covalent photochemical functionalization of amorphous carbon thin films for integrated real-time biosensing.

Recent studies have demonstrated that carbon, in the form of diamond, can be functionalized with molecular and/or biomolecular species to yield interfaces exhibiting extremely high stability and selectivity in binding to target biomolecules in solution. However, diamond and most other crystalline forms of carbon involve high-temperature deposition or processing steps that restrict their ability to be integrated with other materials. Here, we demonstrate that photochemical functionalization of amorphous carbon films followed by covalent immobilization of DNA yields highly stable surfaces with excellent biomolecular recognition properties that can be used for real-time biological detection. Carbon films deposited onto substrates at 300 K were functionalized with organic alkenes bearing protected amine groups and characterized using X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The functionalized carbon surfaces were covalently linked to DNA oligonucleotides. Measurements show very high selectivity for binding to the complementary sequence, and a high density of hybridizing DNA molecules. Samples repeatedly hybridized and denatured 25 times showed no significant degradation. The ability to use amorphous carbon films as a basis for real-time biosensing is demonstrated by coating quartz crystal microbalance (QCM) crystals with a thin carbon film and using this for covalent modification with DNA. Measurements of the resonance frequency show the ability to detect DNA hybridization in real time with a detection limit of <3% of a monolayer, with a high degree of reversibility. These results demonstrate that functionalized films of amorphous carbon can be used as a chemically stable platform for integrated biosensing using only room-temperature processing steps.

Biosensing Techniques↗

Optical biosensing of nitrite ions using cytochrome cd1 nitrite reductase encapsulated in a sol-gel matrix.

Nitrite is an important human health and environmental analyte. As such, the European Union (EU) has imposed a limit for nitrite in potable water of 0.1 mg l-1 (2.18 microM). In order to develop an optical biosensing system for the determination of nitrite ions in environmental waters, cytochrome cd1 nitrite reductase has been extracted and purified from the bacterium Paracoccus pantotrophus. The protein has been spectroscopically characterised in solution and important kinetic parameters of nitrite reduction of the cytochrome cd1 enzyme, i.e., Km, Vmax and kcat have been determined. The influence of pH on the activity of the cytochrome cd1 has been investigated and the results suggest that this enzyme can be used for the determination of nitrite in the pH range 6-9. Biosensing experiments with the cytochrome cd1 in solution suggested that the decrease in intensity of the absorption band associated with the d1 haem (which is the nitrite binding site), at 460 nm, with increasing nitrite concentrations would enable the measurement of this analyte with the optimum limit of detection. The cytochrome cd1 has been encapsulated in a bulk sol-gel monolith with no structural changes observed and retention of enzymatic activity. The detection of nitrite ions in the range 0.075-1.250 microM was achieved, with a limit of detection of 0.075 microM. In order to increase the speed of response, a sol-gel sandwich thin film structure was formulated with the cytochrome cd1. This structure enabled the determination of nitrite concentrations within ca. 5 min. The sol-gel sandwich entrapped cytochrome cd1 enzyme was found to be stable for several months when the films were stored at 4 degrees C.

Biosensing Techniques↗

Selective, reversible, reagentless maltose biosensing with core-shell semiconducting nanoparticles.

Reagentless and reversible maltose biosensors are demonstrated using ZnS coated CdSe (CdSe@ZnS) nanoparticle emission intensities. This method is based on electron transfer quenching of unimolecular protein-CdSe@ZnS nanoparticle assemblies, which is provided by a protein-attached Ru(II) complex. This Ru(II) complex is presumed to reduce a valence band hole of the CdSe@ZnS excited state by tunneling through the ZnS overcoating. The Ru(II) complex mediated quenching of CdSe@ZnS nanoparticle emission was only decreased 1.2-fold relative to the CdSe nanoparticle systems. While four different Ru(II) complex attachment sites provided different amounts of nanoparticle emission quenching (1.20 to 1.75-fold decrease), all of these attachment sites yielded maltose-dependent intensity changes (1.1 to 1.4-fold increase upon maltose addition). Maltose dissociation constants for these four biosensing systems range from 250 nM to 1.0 microM, which are similar to the maltose-maltose binding protein dissociation constant that these sensors are based on. The increased fluorescence intensity was found to only occur in the presence of maltose. Furthermore, the ability of these reagentless protein-nanoparticle assemblies to perform maltose biosensing reversibly is demonstrated with the addition of alpha-glucosidase. Three 50 microM maltose additions after alpha-glucosidase addition showed increases of 2.2 microM, 600 nM, and 150 nM maltose. This result demonstrates a fluorometric method for examining alpha-glucosidase activity. Using maltose binding protein to control Ru(II) complex interactions with CdSe@ZnS nanoparticle surfaces provide a novel class of highly fluorescent, photostable biosensors that are selective for maltose.

Biosensing Techniques↗

Microsurface plasmon resonance biosensing based on gold-nanoparticle film.

We use a gold-nanoparticle coated film to achieve highly spatially resolved biosensing that is based on localized surface-plasmon resonance. Unlike the planar gold film employed for conventional surface-plasmon resonance sensing, the gold-nanoparticle film relies exclusively on shifting of the peak extinction wavelength for detection of biointeraction and does not depend critically on the angle of incidence. These characteristics permit integration of surface-plasmon resonance with large-numerical-aperture optics to achieve biosensing with high sensitivity and spatial resolution as high as 25 microm.

Antigen-Antibody Reactions↗

[Biosensing techniques for the laboratory medicine].

Biosensing techniques are utilized in micro analysis of the biological constituents with an integrated device. Their applications to laboratory medicine are of great interest. Recently, several types of micro electrodes or ion sensitive field effect transistors (ISOFET) were developed. For fabrication of the biosensor selection of the proper bio-element and transducer to assay our sample, is important. In this article we will indicate some items on the future prospect of biosensing techniques for laboratory medicine.

Biosensing Techniques↗

Combined percutaneous biosense-guided laser myocardial revascularization and coronary intervention.

Laser myocardial revascularization is a promising new treatment strategy for patients with severe ischemic heart disease who are not candidates for conventional percutaneous or surgical revascularization. The open chest surgical approach to transmyocardial revascularization has been approved by the FDA for the treatment of angina in inoperable patients, but has had limited use as a stand-alone procedure. More recently, use of fiber-optic catheters has made it possible to use a holmium:yttrium aluminum garnet laser to perform percutaneous catheter-based transmyocardial revascularization. To the extent that many patients have a combination of ischemic sources, some amenable to conventional revascularization and some not, combination or hybrid approaches have been considered. We report herein two patients with class IV angina who underwent laser myocardial revascularization using the Biosense system and complex percutaneous coronary intervention during the same procedure. Areas amenable to conventional percutaneous coronary intervention (PCI) were so treated, and viable but ischemic areas were supplied by totally occluded native vessels and bypass grafts underwent Biosense-guided laser myocardial revascularization (LMR). As the results of more controlled and blinded studies of laser myocardial revascularization become available (if results continue to be promising) and a better understanding of the mechanism of action of this treatment modality is achieved, LMR-PTCA hybrid will be performed in increasing frequency. However, even after establishing LMR efficacy, studies of LMR-PTCA hybrid should be conducted to determine the efficacy of this approach.

Adolescent↗

Multilayered assembly of dendrimers with enzymes on gold: thickness-controlled biosensing interface

A new approach to construct a multilayered enzyme film on the Au surface for use as a biosensing interface is described. The film was prepared by alternate layer-by-layer depositions of G4 poly(amidoamine) dendrimers and periodate-oxidized glucose oxidase (GOx). The cyclic voltammograms obtained from the Au electrodes modified with the GOx/dendrimer multilayers revealed that bioelectrocatalytic response is directly correlated to the number of deposited bilayers, that is, to the amount of active enzyme immobilized on the Au electrode surface. From the analysis of voltammetric signals, the coverage of active enzyme per GOx/dendrimer bilayer during the multilayer-forming steps was estimated, which demonstrates that the multilayer is constructed in a spatially ordered manner. Also, with the ellipsometric measurements, a linear increment of the film thickness was registered, supporting the formation of the proposed multilayered structure. The E5D5 electrode showed the sensitivity of 14.7 microA x mM(-1) glucose x cm(-2) and remained stable over 20 days under day-by-day calibrations. The proposed method is simple and would be applicable to the constructions of thickness- and sensitivity-controllable biosensing interfaces composed of multienzymes as well as a single enzyme.

Journal Article↗

Biosense mapping for ablation of ventricular tachycardia in cardiomyopathy.

Using conventional technology, radiofrequency ablation of ventricular tachycardia in cardiomyopathy is frequently unsuccessful because of hemodynamic instability, multiple foci and recurrences. The Biosense CARTO nonfluoroscopic mapping and navigation system, when used to locate the area of the scar or reentry circuit, has the potential to improve the successful ablation, and reduce the rate of recurrence. We report 2 cases here of ventricular tachycardia in cardiomyopathy in which Biosense mapping was useful to identify the area of scar in 1 case, and the area of microreentry circuits in another. Radiofrequency ablation was possible and successful, while the use of conventional mapping was impossible or had recurrence.

Adult↗

BioSense--a national initiative for early detection and quantification of public health emergencies.

BioSense is a national initiative to enhance the nation's capability to rapidly detect, quantify, and localize public health emergencies, particularly biologic terrorism, by accessing and analyzing diagnostic and prediagnostic health data. BioSense will establish near real-time electronic transmission of data to local, state, and federal public health agencies from national, regional, and local health data sources (e.g., clinical laboratories, hospital systems, ambulatory care sites, health plans, U.S. Department of Defense and Veterans Administration medical treatment facilities, and pharmacy chains).

Algorithms↗