Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Effects of changes in segmental values and timing of both torque and torque reversal in simulated throws.

An overarm throw in the sagittal plane was simulated using a three-segment model representing the upper arm, forearm and hand plus ball. Torque inputs at each joint were turned on at systematically varied times and maintained constant once initiated. All simulations began from identical initial conditions. The aim was to determine the sequence of onset of joint torques which gave the maximal range which the ball would travel and the maximal velocity of the ball irrespective of direction. Best throws proved to be sequential in that joint torques were turned on in a proximal to distal (P-D) temporal sequence. The P-D sequence was also demonstrated by time of peak joint angular velocities. The P-D sequence also proved to be best when segmental constants and joint torques were changed. As this sequence is a common feature of skilled throwing and striking, it is concluded that the linked segmental nature of the limb, irrespective of normal muscle characteristics, primarily predisposes the system to the use of a P-D sequence. The algebraic sign of the shoulder and elbow torques was reversed instantaneously to represent the use of antagonistic muscles. This led to increased output if performed late in the throw and in a P-D sequence. It is concluded that the use of antagonism leads to beneficial redistributions of angular velocity amongst limb segments.

Arm↗

Torque, total work, power, torque acceleration energy and acceleration time assessed on a dynamometer: reliability of knee and elbow extensor and flexor strength measurements.

Isometric torque and isokinetic peak torque, total work, power, torque acceleration energy and acceleration time at 30, 120 and 240 degrees.s-1 of the knee and elbow extensors and flexors were measured using an isokinetic dynamometer in 24 healthy women. Intrasession variation of the measurements was evaluated and the short-term and long-term reliability was assessed by repeating all procedures after averages of 2 and 30 days, respectively. The effect of learning on peak torque during a session was also evaluated. Moreover, the effect of general warming-up on knee extensor and flexor strength was examined on a separate day. Using correlations, numerous studies have indicated that muscle strength measurements are reliable. Correlations, however, are inappropriate and misleading in studies on reliability. In the present study reliability of each strength variable was expressed as the coefficient of variation (CV). With the protocol used, neither learning nor warming-up had any significant effect on strength. As expected, intra-session variation tended to be less than short-term and long-term inter-session variation. The CVs for strength variables measured 30 days apart exceeded 5% for all variables and rose to 107% for acceleration time. Substantial between-subject variation of individual CVs were found. The study demonstrated that muscle strength measurements may be highly unreliable in the individual subject.

Acceleration↗

Optical torque wrench: angular trapping, rotation, and torque detection of quartz microparticles.

We describe an apparatus that can measure the instantaneous angular displacement and torque applied to a quartz particle which is angularly trapped. Torque is measured by detecting the change in angular momentum of the transmitted trap beam. The rotational Brownian motion of the trapped particle and its power spectral density are used to determine the angular trap stiffness. The apparatus features a feedback control that clamps torque or other rotational quantities. The torque sensitivity demonstrated is ideal for the study of known biological molecular motors.

Optics and Photonics↗

Reproducibility of isokinetic peak torque and angle at peak torque in the shoulder joint.

Adequate reliability studies of knee flexion and extension are currently available for isokinetic measurements, but not for the shoulder joint. For this reason, this study examines the variability (%) in the determination of peak torque (PT) and the angle at peak torque (AP) in the test-retest procedure. Differentiation is made between the various types of work (concentric, isometric, eccentric) and the degrees of freedom in the shoulder joint (flexion/extension, abduction/adduction, external rotation/internal rotation). The results show a variability of PT for concentric measurements of 15.0%-19.0% for all degrees of freedom; for flexion/extension and abduction/adduction in isometric and eccentric work, the variability is 17.5%-25.3%. External and internal rotation show generally greater deviation (29.0%-35.3%), except in concentric work. The angle at peak torque can only be reproduced to a limited degree (25.1%-41.1% variability). It is concluded that lower reproducibility can be attained for the shoulder joint compared to the knee joint, depending on the degree of freedom and exercise form tested. It appears meaningful to cite only ranges for the angle at peak torque.

Adult↗

Reliability of measuring isometric and isokinetic peak torque, rate of torque development, integrated electromyography, and tibial nerve conduction velocity.

To determine the reliability of measures used in neuromuscular diagnosis and rehabilitation, 23 adults underwent identical testing on two occasions. Intraclass correlation coefficients (ICC) showed the reliability of peak torque measurement to depend both on the movement tested and velocity of contraction (leg extension ICC = 0.64-0.94, plantar flexion ICC = 0.55-0.76, leg press ICC = 0.72-0.91). Peak rate of torque development (RTD) and the percentage of peak torque at peak RTD were not reliable for any movement (ICC = 0.02-0.28). Mean RTD between 30% and 60% of peak torque was unreliable for leg press (ICC = 0.46), yet fairly reliable for both knee extension (ICC = 0.61) and plantar flexion (ICC = 0.63). Mean integrated electromyography (IEMG) showed fair to good reliability for isometric and 1.05 rad.s-1 leg press (ICC = 0.66, 0.90, respectively), and plantar flexion and leg extension (ICC = 0.75-0.89). Tibial nerve conduction velocity was highly reliable (ICC = 0.89). A range of reliabilities can be expected when measuring these variables, and must be considered when interpreting neuromuscular data.

Adult↗

Failure of ProFile instruments used with air, high torque control, and low torque control motors.

OBJECTIVE: The purpose of this study was to evaluate the influence of 350-rpm rotational speed on the failure incidence of ProFile nickel-titanium rotary instruments (PRI) when used by an experienced operator in conjunction with different motors. STUDY DESIGN: Extracted human mandibular and maxillary first and second molars demonstrating curvatures greater than 25 degrees were used. PRI sizes 40 to 15 and with 0.06 taper were used in crown-down fashion at 350 rpm. In groups 1 through 4, air, high torque control, low torque control, and very low torque control motors were used, respectively. Each group included 30 canals. One set of PRI was used for each canal. Before each use the PRI set was sterilized by steam autoclave. The canals were enlarged until a size 25 PRI reached the working length. A 2.5 x magnification was used to check for instrument deformation after each passage. The number of deformed and separated instruments was recorded for the various experimental groups. RESULTS: Instrument deformation and separation did not occur in any of the 4 groups. CONCLUSIONS: The results suggested that the use of PRI in conjunction with the different motors by an experienced operator in a crown-down manner at 350 rpm is safe.

Air Pressure↗

Progression towards AIDS leads to increased Torque teno virus and Torque teno minivirus titers in tissues of HIV infected individuals.

Torque teno virus (TTV) and Torque teno minivirus (TTMV) are highly prevalent in the general population and although no disease has been associated with these viruses yet, co-infections with other pathological viruses are frequent. Both viruses are extremely heterogeneous, especially for DNA viruses, and the role of the immune system in controlling the infections has yet to be established. In this study the TTV/TTMV viral loads in HIV positive tissues have been investigated for the first time. The titers of both TTV and TTMV were compared in the bone marrow and spleen tissues from three groups: HIV negative individuals, HIV positive individuals and HIV positive individuals who had progressed to AIDS, leading to immunosuppression. Limiting dilution PCR using primers situated in the UTR region of the genome were used to semi-quantitate the virus, and TTV and TTMV were differentiated using melting curve analysis of the PCR product. The AIDS group had significantly higher titers compared with both the HIV positive and negative groups for both bone marrow (AIDS vs. HIV positive P = 0.006, AIDS vs. HIV negative P < 0.001) and spleen (AIDS vs. HIV positive P = 0.022, AIDS vs. HIV negative P < 0.001). Analysis of TTV/TTMV titer with CD4 T lymphocyte count showed a significant inverse correlation however neither HCV co-infection or type of Anellovirus infection (single TTV or TTMV, or mixed TTV/TTMV) showed any significant correlation with virus titer. The results show a link between deterioration of the immune system and increased the viral loads in studied tissues.

AIDS-Related Opportunistic Infections↗

Maximal peak torque as a predictor of angle-specific torques of hamstring and quadriceps muscles in man.

This study assessed the relationship between the isokinetic peak torque (PT) (speed of movement 1.05 and 3.14 rads-1) and the angle-specific torques (ASTs) at 0.26 and 1.31 rad of knee flexion in multiple contractions of the quadriceps and hamstrings in 70 individuals with a chronic anterior cruciate ligament (ACL) insufficiency and 78 individuals with a chronic medial collateral ligament (MCL) insufficiency in one knee. At every test speed, the Pearson product moment correlation coefficients (r) between the PT and ASTs were highly significant (P less than 0.001) in the uninjured knees (r = 0.61-0.93) as well as in the knees with ACL (r = 0.61-0.87) and MCL (r = 0.74-0.91) insufficiency. In addition, in both groups the majority of the correlation coefficients exceeded 0.80, which is generally regarded as the threshold for the relationship to be considered clinically significant. Furthermore, using regression analysis, both extremities showed completely non-systematic distribution of the residuals. It is concluded that in healthy knees or knees with ACL or MCL insufficiency, the predictability of ASTs from PT was good, and, therefore, that AST analyses may offer little additional information about thigh muscle function to that obtained from a simpler and more commonly used measurement, the PT analysis.

Adult↗

Normality, variability and predictability of work, power and torque acceleration energy with respect to peak torque in isokinetic muscle testing.

This study evaluated at two different test sessions the normality and variability of the isokinetic peak torque (PT), peak work (PW), peak power (PP) and peak torque acceleration energy (PTAE) data outputs in healthy adult males (n = 10) and females (n = 10). The hamstring and quadriceps muscles were tested at the angular velocities of 60 deg/s (a slow speed test) and 240 deg/s (a high speed test). The predictability of the PW, PP and PTAE from the PT was also assessed. The results showed that the consistency of the PW and PP measurements were equal with that of the PT. This was due to equal (almost normal) data distribution, equal variability of the outputs (the coefficient of variation (cv) ranged from 14 to 29% in the PWs and PPs versus 16 to 29% in the PTs), and excellent predictability of the PW and PP from the PT (PTs accounted on an average 85% for the variation seen in the PWs and PPs). In addition, in the regression analyses the standard errors of the estimates (SEEs) were low (less than 10%) and the residuals were distributed nonsystematically. In the PTAE measurements, the results were much more inconsistent, especially during the slow speed of the dynamometer. Compared with PT, PW and PP, the PTAE data distribution differed more frequently from normal distribution and the PTAE outputs showed higher variability. In addition, the PTAE outputs could not be acceptably predicted from the PT. In conclusion, the isokinetic PW and PP measurements can be recommended for clinical use, while the PTAE measurements should not be used routinely.

Adult↗

Prediction of torque acceleration energy and power of thigh muscles from peak torque.

The purpose of this study was to assess the relationship between the isometric and isokinetic peak torque (PT) (speed of movement 0, 60, and 180 degrees.s-1) and the peak torque acceleration energy (PTAE) and average power (AP) of multiple contractions (180 degrees.s-1) of the quadriceps and hamstrings in 38 patients having a chronic, complete anterior cruciate ligament (ACL) insufficiency in the knee. At every test speed the Pearson product moment (r) and the Spearman rank (rs) correlation coefficients between the PT and PTAE were highly significant for both muscle groups in the uninjured (r = 0.79-0.94, rs = 0.78-0.94) as well as in the ACL-insufficient (r = 0.87-0.95, rs = 0.83-0.94) knees. The results were the same between the PT and AP (uninjured: r = 0.70-0.90, rs = 0.68-0.90; ACL insufficient: r = 0.86-0.93, rs = 0.82-0.93). In both knees and in both muscle groups the correlation coefficients increased simultaneously with the speed of movement, obviously since the PTAE and AP were registered at the highest test speed (180 degrees.s-1). In conclusion, concerning ACL-insufficient or uninjured knees, the PTAE or AP analysis may offer little additional information about thigh muscle function to that attained by more simple measurement, the PT analysis.

Acceleration↗

Torque acceleration energy, power and peak torque in thigh muscles after a previous knee sprain.

This investigation assessed the relationship between the isometric and isokinetic peak torque (PT) (speed of movement 0, 60, and 180 degrees(s) and (I) the peak torque acceleration energy (PTAE), and (2) average power (AP) of multiple contractions (180 degrees/s) of the quadriceps and hamstrings in subjects with a past history of a grade I knee injury. At every test speed the Pearson product moment (r) and the Spearman rank (rs) correlation coefficients between the PT and PTAE were significant (p less than .001) for both muscle groups in the uninjured (r = .83-.97, rs = .84-.97) as well as in the injured (r = .86-.95, rs = .86-.95) Knees. The results were similar in comparison of PT and AP (uninjured: r = .81-.97, rs = .81 -.97; injured: r = .82-.98, rs = .83-.98). The PTAE and AP analyses offer little additional information about thigh muscle function to that obtained through more simple measurements, the PT analysis.

Adult↗

Muscle response to pneumatic hand tool torque reaction forces.

Surface electromyography was used for studying the effects of torque reaction force acting against the hand, on forearm muscle activity and grip force for five subjects operating right angle, air shut-off nutrunners. Four tools having increasing spindle torque were operated using short and long torque reaction times. Nutrunner spindle torque ranged between 30 Nm and 100 Nm. Short torque reaction time was considered 0.5 s while long torque reaction time was 2 s. Peak horizontal force was the greatest component of the reaction force acting against the hand and accounted for more than 97% of the peak resultant hand force. Peak hand force increased from 89 N for the smallest tool to 202 N for the largest tool. Forearm muscle rms EMG, scaled for grip force, indicated average flexor activity during the Torque-reaction phase was more than four times greater than the Pre-start and Post Shut-off phases, and two times greater than the Run-down phase. Flexor EMG activity during the Torque-reaction phase increased for increasing tool peak spindle torque. Average flexor rms EMG activity, scaled for grip force, during the Torque-reaction phase increased from 372 N for the 30 Nm nutrunner to 449 N for the 100 Nm nutrunner. Flexor rms EMG activity averaged during the Torque-reaction phase and scaled for grip force was 390 N for long torque reaction times and increased to 440 N for short torque reaction times. Flexor rms EMG integrated over the torque reaction phase was 839 Ns for long torque reaction times and decreased to 312 Ns for short torque reaction times. The average latency between tool spindle torque onset and peak initial flexor rms EMG for long torque reaction times was 294 ms which decreased to 161 ms for short torque reaction times. The average latency between peak tool spindle torque, just prior to tool shut-off, and peak final rms EMG for long torque reaction times was 97 ms for flexors and 188 ms for extensors, which decreased for short torque reaction times to 47 ms for flexors and 116 ms for extensors. The results suggest that right angle nutrunner torque reaction forces can affect extrinsic hand muscles in the forearm, and hence grip exertions, by way of a reflex response.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Cerebellar ataxia: abnormal control of interaction torques across multiple joints.

1. We studied seven subjects with cerebellar lesions and seven control subjects as they made reaching movements in the sagittal plane to a target directly in front of them. Reaches were made under three different conditions: 1) "slow-accurate," 2) "fast-accurate," and 3) "fast as possible." All subjects were videotaped moving in a sagittal plane with markers on the index finger, wrist, elbow, and shoulder. Marker positions were digitized and then used to calculate joint angles. For each of the shoulder, elbow and wrist joints, inverse dynamics equations based on a three-segment limb model were used to estimate the net torque (sum of components) and each of the component torques. The component torques consisted of the torque due to gravity, the dynamic interaction torques induced passively by the movement of the adjacent joint, and the torque produced by the muscles and passive tissue elements (sometimes called "residual" torque). 2. A kinematic analysis of the movement trajectory and the change in joint angles showed that the reaches of subjects with cerebellar lesions were abnormal compared with reaches of control subjects. In both the slow-accurate and fast-accurate conditions the cerebellar subjects made abnormally curved wrist paths; the curvature was greater in the slow-accurate condition. During the slow-accurate condition, cerebellar subjects showed target undershoot and tended to move one joint at a time (decomposition). During the fast-accurate reaches, the cerebellar subjects showed target overshoot. Additionally, in the fast-accurate condition, cerebellar subjects moved the joints at abnormal rates relative to one another, but the movements were less decomposed. Only three subjects were tested in the fast as possible condition; this condition was analyzed only to determine maximal reaching speeds of subjects with cerebellar lesions. Cerebellar subjects moved more slowly than controls in all three conditions. 3. A kinetic analysis of torques generated at each joint during the slow-accurate reaches and the fast-accurate reaches revealed that subjects with cerebellar lesions produced very different torque profiles compared with control subjects. In the slow-accurate condition, the cerebellar subjects produced abnormal elbow muscle torques that prevented the normal elbow extension early in the reach. In the fast-accurate condition, the cerebellar subjects produced inappropriate levels of shoulder muscle torque and also produced elbow muscle torques that did not very appropriately with the dynamic interaction torques that occurred at the elbow. Lack of appropriate muscle torque resulted in excessive contributions of the dynamic interaction torque during the fast-accurate reaches. 4. The inability to produce muscle torques that predict, accommodate, and compensate for the dynamic interaction torques appears to be an important cause of the classic kinematic deficits shown by cerebellar subjects during attempted reaching. These kinematic deficits include incoordination of the shoulder and the elbow joints, a curved trajectory, and overshoot. In the fast-accurate condition, cerebellar subjects often made inappropriate muscle torques relative to the dynamic interaction torques. Because of this, interaction torques often determined the pattern of incoordination of the elbow and shoulder that produced the curved trajectory and target overshoot. In the slow-accurate condition, we reason that the cerebellar subjects may use a decomposition strategy so as to simplify the movement and not have to control both joints simultaneously. From these results, we suggest that a major role of the cerebellum is in generating muscle torques at a joint that will predict the interaction torques being generated by other moving joints and compensate for them as they occur.

Adult↗

Relation between torque history, firing frequency, decruitment levels and force balance in two flexors of the elbow.

By means of intramuscular electromyographic recordings, we studied the firing frequencies and recruitment/decruitment thresholds of individual motor units in two elbow flexors, the biarticular biceps brachii muscle and the monoarticular brachioradialis muscle. Subjects had to perform isometric contractions with increasing elbow flexion torque until a specific peak torque level was reached. The torque level was kept constant for 6 s during which firing frequencies were measured. Then the torque was decreased to a lower level and, after 3 s, firing frequencies were again measured for 6 s. By repeating this procedure, the torque level was decreased stepwise until the motor unit under study stopped firing. The last level before the unit stopped firing was considered to be the decruitment torque level. We measured the firing frequency at recruitment and decruitment, the torque-frequency relationship and the recruitment and decruitment torque thresholds after various levels of peak torque. In the biceps, both the firing frequencies at a specific torque level and the decruitment torque level itself were independent of the peak torque. In the brachioradialis, however, firing frequencies at a specific torque level decreased and decruitment torque levels increased after subjects generated higher peak torques. Thus, in this muscle firing frequencies as well as decruitment thresholds show hysteresis effects. The result indicates a shift of force from the brachioradialis muscle during recruitment to the biceps muscle during decruitment. This shift is smaller than was concluded from previous studies in which decruitment threshold levels for the brachioradialis muscle were assumed to be independent of force history. Moreover, we found that in both muscles decruitment firing frequencies were lower than recruitment frequencies and they were independent of the peak torque level. In order to analyse the effect of the peak torque level on the distribution of force over the two muscles, we performed a model study in which we simulated the activation-frequency relation of two elbow flexors: a biceps-like and brachioradialis-like muscle, each contributing equally to the elbow torque during recruitment. In addition, we analysed how the different behaviour of the biceps and the brachioradialis during decruitment alters their contribution to the total torque production and how this redistribution is caused. The model study shows that the shift in contribution to the total torque is not constant during the relaxation phase and is not caused by a simple mechanism like a shift of activation from one muscle to another. Furthermore, changes limited to the muscle in which hysteresis is present do not seem to be sufficient to explain the experimental results.

Action Potentials↗