Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tape Recording”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Use of tape-recorded food records in assessing children's dietary intake.

BACKGROUND: Dietary assessment among children is particularly problematic when techniques are dependent on memory skills or advanced cognitive development. OBJECTIVE: The current study explored the use of self-report by tape recorders to document children's dietary intake immediately upon consumption, and compared this method with the traditional, interviewer-guided recall technique. In addition, the influence of body fatness and sociodemographic characteristics on the accuracy of recall and tape-recorded food records was determined. RESEARCH METHODS AND PROCEDURES: The sample included 30 black and white children aged 6.5 to 11.6 years (x = 9.5). Energy intake (EI), measured by six 24-hour food records (three for each method), was compared with total energy expenditure calculated by the doubly labeled water technique. Paired t tests, correlation analyses, and multiple regression analyses were performed. RESULTS: The analyses revealed poor validity of the tape recorder method (x misreporting score = -1.13+/-2.62 MJ/day, r for total energy expenditure and EI = -0.06, p = 0.74). Estimates of EI differed significantly between the tape recorder and recall methods (p<0.01). The traditional recall method was confirmed as a valid estimate of energy intake (x misreporting score = 0.04+/-2.38 MJ/day), although demonstrating a modest correlation with TEE (r = 0.32, p = 0.08). Although no significant predictors of misreporting using the recall method were identified in the multivariate analyses, older children and children with higher adiposity were more likely to misreport using the tape recorder method. DISCUSSION: The results suggest that the use of the tape recorder for estimating EI does not result in accurate assessments among children, although this technique may be useful for specific subgroups (i.e., younger and leaner children).

Black People↗

Cognitive screening using a tape recorder: a pilot study.

OBJECTIVES: To determine whether a tape recorder can be used to administer cognitive tests efficiently and yield valid results. DESIGN: Convenience sample. Administration of cognitive test materials by tape recorder and conventional technique. SETTING: Outpatient clinic. PARTICIPANTS: Subjects from memory disorder clinic, hostel accommodation, and community. MEASUREMENTS: Responses to Hopkins Verbal Learning Test-revised, verbal fluency items from the controlled oral word association test, 10-item naming task, a construction task, and speed writing task. RESULTS: Performances on the tape- and clinician-administered battery of tests were highly correlated. Memory impairment was accurately detected using the tape battery. Data from 30 minutes of testing via tape were obtained at the cost to the clinician of 2 to 3 minutes of scoring time. CONCLUSION: Tape-administration of cognitive test material warrants further study as an efficient means of cognitive screening.

Adult↗

Dietary assessment in children using electronic methods: telephones and tape recorders.

Selection of dietary assessment methodology is important in dietary intervention studies. Few studies have reported the relative merits of various assessment methods or the feasibility of electronic methods in pediatric populations. Parent-child dyads performed telephone recalls (no. = 32) and tape recorded dietary records (no. = 33). Traditional recalls were first conducted to familiarize parents and children with the telephone recall procedure, to introduce two-dimensional food models, and to instruct on the use of the tape recorder. Parents monitored and documented as unobtrusively as possible the child's intake on the day before the telephone recall and also on the day of the taped record. Children were called at random to reduce bias. Simple correlation coefficients (r) were calculated for nine nutrients and calories for both methods. For telephone recalls, values ranged from a low of r = .64 for saturated and polyunsaturated fat to r = .85 for cholesterol and r = .93 for iron. Tape-recorded data yielded r = .80 or above, except calories with r = .68 (p less than .001 for all values, 1-tail tests). Mean nutrient values were within expected ranges, e.g., 1,800 kcal +/- 500, with saturated fat about 14% of calories per day. Comparisons between parents and childrens reports of food frequencies and portion sizes revealed the best correlations for beverages, bread-cereals-crackers, meat-fish-poultry, and mixed dishes. We conclude that preadolescent children are able to provide dietary intake data using electronic methods in a manner that compares favorably with their parents' written records.

Child↗

Stress-reducing effect of physician's tape-recorded support on cardiac surgical patients in the intensive care unit.

Staying in an intensive care unit (ICU) is very stressful for patients after heart surgery. Although it is a general belief that support from doctors is important to reduce patients' tension, no quantitative data are available. We investigated the stress-reducing effects of a tape-recorded message from the physician which provided information regarding the surgery and emotional support for heart surgery patients postoperatively in the ICU. Sixty patients who underwent cardiac surgery were randomly allocated to two equal groups. The patients in the experimental group listened to a tape-recorded message from their attending surgeon soon after they recovered from anesthesia, while the control group rested during the study period. The effectiveness of the tape-recorded support program was evaluated by the influence on heart rate, blood pressure, and finger skin temperature, as well as the degree of subjective pain, tension, anxiety, depression, and anger. The pain and tension levels of the patients were measured using a visual analogue scale, while the severity of anxiety, depression, and anger was evaluated using the Brief Symptom Rating Scale. Patients' evaluation of the usefulness of the program was also assessed. After listening to the physician's recorded message, the mean increase in the skin finger temperature in the experimental group was higher than in the control group (0.44 degree C vs 0.25 degree C, p = 0.0513). The experimental group had significant decreases in their mean scores of pain (-1.11 vs 0.36, p = 0.0043), tension (-2.26 vs -0.25, p = 0.0001), anxiety (-1.3 vs -0.57, p = 0.0473), and depression (-2.24 vs -0.37, p = 0.0253). The patients showed a high need for this support program (mean need score 8.4). These findings show that a physician's tape-recorded message providing information and emotional support can reduce stress in heart surgery patients in the ICU postoperatively.

Cardiac Surgical Procedures↗

Jitter analysis utilizing a high speed FM tape recorder.

Jitter analysis in single fiber EMG (SFEMG) is usually done on-line during recording. However, this technique frequently prolongs the study and makes re-analysis impossible. We attempted to measure jitter with a high speed FM tape recorder and compare the results with the previously published values. SFEMG data, acquired with voluntary activation on extensor digitorum communis muscle of 25 healthy relatives of children with myasthenia gravis were retrospectively analyzed. Fiber density (FD) was estimated on-line. Five to 18 single fiber action potential (SFAP) pairs were studied in each subject. The wow of the tape recorder was 6 microseconds. Mean (SD) (upper 95th percentile) FD, individual jitter, highest jitter, mean jitter and interspike interval were 1.60 (0.18) (1.90), 25.30 (11.20) (57.00) microseconds, 31.24 (6.87) (47.00) microseconds, 25.08 (5.04) (43.00) microseconds, and 0.67 (0.11) (0.91) ms respectively. Mean jitter in the pooled SFAP pairs and mean MCD were found to be lower than the published values of the Ad Hoc Committee of the AAEM Special Interest Group on Single Fiber EMG. A high speed FM tape recorder can be reliably used for the off-line analysis of jitter.

Action Potentials↗

[Image filing system for radiotherapy using a video tape recorder].

The compact media of video tape is applied to store medical images with spoken reporting. Video tape recorder (VTR), personal computer, and video/computer interface constitute our image filing system. VTR is controlled automatically by personal computer. Our system enable to file images including moving images, and color images easily, and established cheap and useful image filing system.

Humans↗

"What did you say?" Using review of tape-recorded interactions to increase social acknowledgments by trainees in a community-based vocational program.

Dana and Rick, two adults with developmental disabilities enrolled in a restaurant training program, had poor prospects for long-term employment because of inappropriate social behavior. They often made no response, mumbled inaudibly, or made a negative remark when spoken to by their supervisors or other employees. Each trainee's Individual Vocational Plan (IVP) included goals of prompt and polite acknowledgement of coworker initiations. Previous efforts to improve Dana and Rick's acknowledging behavior had been unsuccessful. Throughout the study, each trainee's responses to 20 verbal initiations by coworkers (i.e., requests, questions, corrective feedback, praise, and social comments) were recorded during each of two observation periods per workshift. Throughout one of the observation periods during the intervention phases, the trainees carried in their work aprons a small, audio cassette recorder that recorded their interactions with coworkers. The primary intervention consisted of a preworkshift meeting in which the trainee and experimenter reviewed five randomly selected interactions recorded during the previous day's shift. The review included self-evaluation, praise, corrective feedback, and role-play. A multiple baseline across subjects design showed each trainee acknowledged a greater number of coworker initiations as a function of the intervention. Each trainee also acknowledged more coworker initiations during the second observation period when the tape recorder was never worn. In a subsequent intervention phase, Dana reviewed her tape-recorded interactions prior to randomly selected shifts. Rick's acknowledgments increased to a socially valid level when the review procedure was supplemented with graphic feedback. Both trainees continued to acknowledge their coworkers' initiations at levels equal to nondisabled restaurant employees when they no longer wore the tape recorder during a final phase and during follow-up observations 4 to 8 weeks later.

Adult↗

An inexpensive digital tape recorder suitable for neurophysiological signals.

Modifications are described which convert an inexpensive 'Digital Audio Processor' (Sony PCM-701ES), together with a video cassette recorder, into a high performance digital tape recorder, with two analog channels of 16 bit resolution and DC-20 kHz bandwidth. A further modification is described which optionally provides four additional 1-bit digital channels by sacrificing the least significant four bits of one analog channel. If required two additional high quality analog channels may be obtained by use of one of the new video cassette recorders (such as the Sony SL-HF100) which incorporate a pair of FM tracks.

Neurophysiology↗

A 16-channel cassette tape recorder system for clinical EEGs.

A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

Electroencephalography↗

Accuracy and reliability of 'specialized' physical therapists in auscultating tape-recorded lung sounds.

This study investigated the accuracy and inter-rater reliability of 'specialized' physical therapists in the auscultation of tape-recorded lung sounds. In addition, a correlation was investigated between accuracy of interpretation and the number of years of specialization in the field of cardiorespiratory physical therapy. This research follows an earlier study which investigated the accuracy and inter-rater reliability of auscultating tape-recorded lung sounds in a 'non-specialized' cohort of physical therapists. The subjects were 26 'specialized' cardiorespiratory physical therapists working in acute urban teaching hospitals. These individuals were required to have been practising currently and exclusively for at least one year in the area of cardiorespiratory physical therapy. Participants listened with a stethoscope to five different sounds and identified them from a standardized list of terms. One of three tapes with the same lung sounds in different order was randomly selected for each physical therapist. The percentage of correct answers for all subjects was calculated. An accurate response in the detection of lung sounds was arbitrarily defined as a percentage of correct answers of 70% or greater. The difference between the pooled correct response rate of 50% and the arbitrarily set value of 70% was statistically significant (z = 2.23, p < 0.05), indicating that the 'specialized' physical therapists were not accurate in identifying lung sounds. There was no relationship evident between the accuracy and the number of years of cardiorespiratory 'specialization' (r = 0.08). Analysis of inter-rater reliability revealed 'fair agreement' (kappa = 0.26) among subjects. These results were similar to those found in the previous study.(ABSTRACT TRUNCATED AT 250 WORDS)

Auscultation↗

[Comparative evaluation of the response of rat-mothers to the natural pain squeaks of a ratling and to a tape recording of it].

Two kinds of stimuli were presented to the mother rat at random: the natural pain acoustic signal of its infant in response to electrical pain stimulation and the tape recording of the signal performed within the sound frequency region (up to 20 kHz). The mother rat was placed in a special long cage with two parts of different size. Her reaction was ethologically estimated. The natural pain signal proved to be more effective than its magnetic tape recording. The role of the spectrum ultrasound part of the pain acoustic signal is discussed.

Animals↗

Heart block in children. Evaluation of subsidiary ventricular pacemaker recovery times and ECG tape recordings.

To evaluate subsidiary ventricular pacemaker function in 20 children with congenital or surgically induced complete heart block, we measured recovery times following overdrive ventricular pacing. Long-term ECG tape recordings were performed in eight of these children. Ages ranged from 1 month to 17 years. The resting R-R intervals ranged from 595 to 1,740 msec. The ventricles were paced at various cycle lengths of 400 to 1,000 msec with either transvenous electrode catheters or surgically implanted epicardial electrodes. His bundle recordings showed that the site of block did not allow separation of patients with symptoms from those without symptoms. Prolonged recovery times were present in patients with block above the His bundle recording site who had symptoms of syncope or dizziness, as well as in patients who had a wide QRS. However, some asymptomatic patient with heart block above the His bundle recording site also had long recovery times. None of the asymptomatic patients who had ECG tape recordings had paroxysmal tachycardia in more than 300 hours of recordings. However, one symptomatic patient with congenital heart block and a prolonged recovery time had brief episodes of paroxysmal ventricular tachycardia that produced no symptoms at the time of recording. The results suggest that the coexistence of prolonged recovery times and paroxysmal tachycardia may be predisposing factors to the development of symptoms in patients with complete heart block. We believe that further electrophysiologic investigation of this possibility is warranted in patients with heart block.

Adolescent↗

ECG-tape recording for analysis of syncopal attacks before and during cardiac pacing.

ECG-tape recording has been utilized for diagnosis of transient attacks of syncope and dizziness both before and during cardiac pacing. The display unit can be utilized for automatic starting of the ECG writer according to markings made by the patient or bradycardia alarm. The method has proved extremely useful and convenient, which is illustrated by cases with different types of arrhythmia and pacemaker failure.

Ambulatory Care↗

Dynamic mini-computer graphics analysis of long-term electrocardiographic tape recordings.

The full graphic capabilities of a minicomputer have been applied to rapid and versatile analysis of long-term electrocardiographic tape recordings. Interfaced to a standard Avionics tape analyzer, the system's multiple display options provide a powerful tool for arrhythmia detection in a reasonable amount of time. Detection accuracy of the system compares very favorably with previously published figures for computer EKG monitoring. Quantitation of arrhythmic beats is an integral feature of the tape scanning. A method for analog display of randomly selectable EKG complexes is also described.

Arrhythmias, Cardiac↗

Teaching with tape-recorded psychoanalysis.

The pedagogic advantages of the study of psychoanalytic process with the help of tape-recorded psychoanalytic sessions is described, with some reference to others' experiences with recording drawn from the literature. Illustration is provided through reference to the reactions of fourth- and fifth-year psychoanalytic candidates to such samplings of one patient's recorded analysis.

Humans↗

A software oscilloscope for DOS computers with an integrated remote control for a video tape recorder. The assignment of acoustic events to behavioural observations.

With only a little knowledge of programming IBM compatible computers in Basic, it is possible to create a digital software oscilloscope with sampling rates up to 17 kHz (depending on the CPU- and bus-speed). The only additional hardware requirement is a common sound card compatible with the Soundblaster. The system presented in this paper is built to analyse the direction a flying bat is facing during sound emission. For this reason the system works with some additional hardware devices, in order to monitor video sequences at the computer screen, overlaid by an online oscillogram. Using an RS232-interface for a Panasonic video tape recorder both the oscillogram and the video tape recorder can be controlled simultaneously and moreover be analysed frame by frame. Not only acoustical events, but also APs, myograms, EEGs and other physiological data can be digitized and analysed in combination with the behavioural data of an experimental subject.

Animals↗