Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TOMOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Integrated computed tomography-positron emission tomography in patients with potentially resectable malignant pleural mesothelioma: Staging implications.

BACKGROUND: Integrated computed tomography-positron emission tomography imaging with coregistration of anatomic and functional imaging data may improve the accuracy of malignant pleural mesothelioma staging. We evaluate the use of integrated computed tomography-positron emission tomography in patients with malignant pleural mesothelioma who are being considered for extrapleural pneumonectomy. METHODS: Twenty-nine patients with malignant pleural mesothelioma who were judged to be candidates for extrapleural pneumonectomy after clinical and conventional radiologic evaluation underwent whole-body integrated computed tomography-positron emission tomography and pathologic staging. Two reviewers blinded to the results of clinical and pathologic staging retrospectively evaluated computed tomography, positron emission tomography, and coregistered computed tomography-positron emission tomography images. Staging was performed according to the International Mesothelioma Interest Group TNM staging system. Histopathology and/or results of further radiologic evaluation or follow-up served as the reference standard. RESULTS: Integrated computed tomography-positron emission tomography provided additional information in 11 of 29 patients that precluded extrapleural pneumonectomy. The overall tumor stage was correctly classified in 21 of 29 patients. The tumor stage was correctly determined in 15 of 24 patients, 6 of whom had T4 (nonresectable) disease. The node stage was accurately determined in 6 of 17 patients. Extrathoracic metastases not identified by routine clinical and conventional radiologic evaluation were detected in 7 of 29 patients and were found to be diffuse (n = 2) or solitary (n = 5). CONCLUSIONS: Integrated computed tomography-positron emission tomography increases the accuracy of malignant pleural mesothelioma staging and is important in determining the appropriate therapy in patients being considered for extrapleural pneumonectomy.

Adult↗

Mediastinal lymph node staging of non-small-cell lung cancer: a prospective comparison of computed tomography and positron emission tomography.

We compared the abilities of positron emission tomography and computed tomography to detect N2 or N3 lymph node metastases (N2 or N3) in patients with lung cancer. Positron emission tomography detects increased rates of glucose uptake, characteristic of malignant cells. Patients with peripheral tumors smaller than 2 cm and a normal mediastinum were ineligible. All patients underwent computed tomography, positron emission tomography, and surgical staging. The American Thoracic Society lymph node map was used. Computed and positron emission tomographic scans were read by separate radiologists blinded to surgical staging results. Lymph nodes were "positive" by computed tomography if larger than 1.0 cm in short-axis diameter. Standardized uptake values were recorded from areas on positron emission tomography corresponding to those from which biopsy specimens were taken; if greater than 4.2, they were called "positive." Seventy-five lymph node stations (2.8 per patient) were analyzed in 27 patients. Computed tomography incorrectly staged the mediastinum as positive for metastases in three patients and as negative for metastases in three patients. Sensitivity and specificity of computed tomographic scans were 67% and 83%, respectively. Positron emission tomography correctly staged the mediastinum in all 27 patients. When analyzed by individual node station, there were four false positive and four false negative results by computed tomography (sensitivity = 60%, specificity = 93%, positive predictive value = 60%). Positron emission tomography mislabeled one node station as positive (100% sensitive, 98% specific, positive predictive value 91%). The differences were significant when the data were analyzed both for individual lymph node stations (p = 0.039) and for patients (p = 0.031) (McNemar test). Positron emission tomography and computed tomography are more accurate than computed tomography alone in detecting mediastinal lymph node metastases from non-small-cell lung cancer.

Adult↗

[18F] 3-deoxy-3'-fluorothymidine positron emission tomography: alternative or diagnostic adjunct to 2-[18f]-fluoro-2-deoxy-D-glucose positron emission tomography in the workup of suspicious central focal lesions?

BACKGROUND: 2-[(18)F]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography has been established as a standard diagnostic imaging method in the preoperative workup of suspicious pulmonary focal lesions, showing a sensitivity of more than 90% and a specificity of about 80%. Determination of malignant pulmonary lesions with FDG positron emission tomography depends on the assessment of glucose metabolism. However, false-positive findings can occur in inflammatory processes, such as sarcoidosis or pneumonia. The thymidine analogue 3-deoxy-3[(18)F]-fluorothymidine (FLT) is a new positron emission tomography tracer that more specifically targets proliferative activity of malignant lesions. The objective of this study was to determine whether FLT positron emission tomography, in comparison with FDG positron emission tomography, provides additional information in the preoperative workup of central pulmonary focal lesions. METHODS: In this prospective study FLT and FDG positron emission tomography examinations were performed as a part of the preoperative workup in 20 patients with histologically confirmed bronchial carcinoma, 7 patients with benign lesions, and 1 patient with an atypical carcinoid. Results were compared with final pathologic findings. RESULTS: For staging of the primary tumor, FLT positron emission tomography revealed a sensitivity of 86% and a specificity of 100% compared with a sensitivity of 95% and a specificity of 73% for FDG positron emission tomography. For N staging, the sensitivity of FLT positron emission tomography was 57% and the specificity was 100%, and for FDG positron emission tomography, the sensitivity was 86% and the specificity was 100%, respectively. CONCLUSIONS: Our preliminary findings indicate specific FLT uptake in malignant lesions. The number of false-positive findings in FDG positron emission tomography might be reduced with FLT positron emission tomography. Therefore positron emission tomography imaging with FLT represents a useful supplement to FDG in assessing the malignancy of central pulmonary focal lesions.

Adenocarcinoma↗

Breath-hold single-photon emission tomography and computed tomography for predicting residual pulmonary function in patients with lung cancer.

OBJECTIVE: We sought to evaluate the utility of integrated breath-hold single-photon emission tomography and computed tomography imaging compared with that of simple calculation with the lung segment-counting technique for predicting residual pulmonary function in patients undergoing surgical intervention for lung cancer. METHODS: A prospective series of 22 patients undergoing anatomic lung resection for cancer were enrolled in this study. Postoperative residual forced expiratory volume in 1 second was predicted by measuring the radioactivity counts of the affected lobes or segments to be resected within the entire lungs by placement of regions of interest on single-photon emission tomography and computed tomography images. Residual forced expiratory volume in 1 second was also estimated by using the segment-counting technique. RESULTS: Both predicted values agreed well with postoperative forced expiratory volume in 1 second. Although the residual forced expiratory volume in 1 second predicted by means of single-photon emission tomography and computed tomography correlated well with that predicted by using segment counting, the values were significantly underestimated by the segment-counting technique in 4 outliers with severe emphysema. There were 2 patients with borderline pulmonary functional reserve whose residual forced expiratory volume in 1 second values were predicted more accurately by means of single-photon emission tomography and computed tomography than by using segment counting. CONCLUSION: Integrated breath-hold single-photon emission tomography and computed tomography images allow the accurate prediction of postoperative pulmonary function but without statistical superiority over the simple segment-counting technique. Further study of the usefulness of single-photon emission tomography and computed tomography in patients with severe emphysema and borderline lung function should prove valuable because the segment-counting technique underestimates pulmonary functional reserve in these patients.

Aged↗

The utility of 2-deoxy-2-[18F]fluoro-D-glucose-positron emission tomography and combined positron emission tomography and computed tomography in lymphoma and melanoma.

The purpose of this article is to review the clinical utility of FDG and FDG PET/CT imaging in lymphoma and melanoma. A review of the important articles supporting the use of FDG PET imaging in the staging, restaging, and monitoring of response to therapy in lymphoma and melanoma is provided. The intent is to give the nuclear medicine physician and or radiologist the perspective of what may be important clinically to make FDG PET imaging an integral part of the workup of lymphoma and melanoma patients. Specific clinical scenarios and uptake patterns that are unique for lymphoma and melanoma are discussed to ensure relevant and proper interpretation of the FDG PET scans. FDG PET scanning in summary is a useful imaging modality in the staging, restaging, and response evaluation of patients with lymphoma and melanoma.

Brain↗

Identification of recurrent ischemia after coronary artery bypass surgery: a comparison of positron emission tomography and single photon emission computed tomography.

Current techniques for the detection of recurrent coronary stenoses following bypass grafting have shown disappointing diagnostic accuracy. This study used the same dipyridamole-handgrip stress to compare the accuracy of rubidium-82 positron emission tomography and thallium-201 single photon emission computed tomography, in 50 consecutive post-bypass patients undergoing coronary arteriography at a mean interval of 6.5 years after surgery. Significant stenoses in native coronary vessels (greater than 50% diameter) or grafts (greater than 70% diameter) were defined by quantitative angiography. Forty-six patients had recurrent or residual stenoses, 43 (93%) had a perfusion defect identified by positron emission tomography, and 35 (76%) were identified by single photon emission computed tomography (P = 0.04). Fourteen of the 17 patients (82%) without previous Q-wave myocardial infarction were identified by positron emission tomography; 10 of the 17 (59%) were detected by single photon emission computed tomography (P = NS). Stress-induced perfusion defects were demonstrated by positron emission tomography in 19 patients; of this group, thallium imaging identified reversible defects in 11, showed no perfusion defect in 1, and portrayed a persistent defect in 7 patients. Significant graft disease was present in 33 patients; perfusion defects were identified by positron emission tomography in 30 (91%), and by single photon emission computed tomography in 24 (73%, P = NS). Four patients were fully revascularized, without significant recurrent coronary disease; normal perfusion was present in 3 (75%) by positron emission tomography, and 4 (100%) by single photon emission computed tomography.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Helical computed tomography alone compared with plain radiographs with adjunct computed tomography to evaluate the cervical spine after high-energy trauma.

BACKGROUND: Current literature supports the use of the three-view plain-radiograph series supplemented, when necessary, with helical computed tomography to evaluate the cervical spine in patients who have sustained trauma injury. The purpose of this study was to determine if helical computed tomography alone can be used to evaluate the cervical spine for acute osseous injury following high-energy trauma, thus eliminating the need to make radiographs. METHODS: Patients were prospectively evaluated with helical computed tomography scanning of the cervical spine and standard three-view plain radiography. At a later date, the plain radiographs and computed tomography scans were independently reviewed by two radiologists who were blinded to both the initial interpretation and the interpretation of the corresponding study. The radiologists documented whether the plain radiographs were adequate and whether they showed an acute process. The findings in the study were compared with the initial findings and, when necessary, with the discharge summaries to determine if an injury had been identified. The accuracy of the plain radiographs, of the plain radiographs that had been deemed adequate, and of helical computed tomography used alone was ascertained. RESULTS: Plain radiographs and helical computed tomography scans were made for 407 patients, and traumatic injuries were identified in fifty-eight of them. Plain radiographs alone were adequate for 194 (48%) of the 407 patients. Plain radiographs had a sensitivity of 45%, a specificity of 97%, a positive predictive value of 74%, and a negative predictive value of 91%. Adequate plain radiographs had a sensitivity of 52%, a specificity of 98%, a positive predictive value of 81%, and a negative predictive value of 93%. Helical computed tomography had a sensitivity and specificity of 98%, a positive predictive value of 89%, and a negative predictive value of >99%. The sensitivity, positive predictive value, and negative predictive value of adequate plain radiographs differed significantly from those of helical computed tomography alone (p < 0.001). Twelve (48%) of twenty-five adequate plain radiographs of patients in whom an injury had been identified on computed tomography missed that injury. Helical computed tomography alone missed one (2%) of the fifty-eight injuries. CONCLUSIONS: Although helical computed tomography has a limited ability to detect pure ligamentous injury, it can be safely used without plain radiographs to evaluate the cervical spine for osseous abnormalities such as fractures and dislocations after high-energy trauma.

Adolescent↗

Detection of pelvic lymph node metastases in patients with clinically localized prostate cancer: comparison of [18F]fluorocholine positron emission tomography-computerized tomography and laparoscopic radioisotope guided sentinel lymph node dissection.

PURPOSE: Accurate detection of lymph node metastases in prostate cancer has important implications for prognosis and approach to treatment. We investigated whether preoperative [18F]fluorocholine combined in-line positron emission tomography-computerized tomography and intraoperative laparoscopic radioisotope guided sentinel pelvic lymph node dissection can detect pelvic lymph node metastases in patients with clinically localized prostate cancer as reliably as extended pelvic lymph node dissection. MATERIALS AND METHODS: A total of 20 patients (mean age 63.9 +/- 6.7 years, range 52 to 75) with clinically localized prostate cancer, prostate specific antigen greater than 10 ng/ml, and/or a Gleason score sum of 7 or greater and negative bone scan were enrolled in the study. [18F]fluorocholine combined in-line positron emission tomography-computerized tomography was performed before surgery. Sentinel pelvic lymph node dissection preceded extended pelvic lymph node dissection including the area of the obturator fossa, external iliac artery/vein and internal iliac artery/vein up to the bifurcation of the common iliac artery. Laparoscopic radical prostatectomy was performed afterward. RESULTS: In 10 of the 20 patients (50%) lymph node metastases were detected, and were exclusively found outside the obturator fossa in 62%. These metastases would not have been identified with standard lymph node dissection of the obturator fossa only. [18F]fluorocholine combined in-line positron emission tomography-computerized tomography was true positive in 1, false-positive in 2, false-negative in 9 and true negative in 8 patients. The largest lymph node metastasis not seen with [18F]fluorocholine combined in-line positron emission tomography-computerized tomography was 8 mm. Laparoscopic sentinel guided lymph node dissection revealed lymph node metastases in 8 of 10 patients. In the other 2 patients sentinel lymph node dissection was not conclusive. In 1 patient normal nodal tissue was completely replaced by cancer and, therefore, there was no tracer uptake in the involved pelvic sidewall/node, and the other patient had no tracer activity at all in the involved pelvic sidewall. Extended pelvic lymph node dissection missed 1 lymph node metastasis (2 mm diameter near pudendal artery) which was detected by sentinel pelvic lymph node dissection only. CONCLUSIONS: Extended pelvic lymph node dissection reveals a higher number of lymph node metastases as described for obturator fossa dissection only. [18F]fluorocholine combined in-line positron emission tomography-computerized tomography is not useful in searching for occult lymph node metastases in clinically localized prostate cancer. Sentinel guided pelvic lymph node dissection allows the detection of even small lymph node metastases. The accuracy of sentinel pelvic lymph node dissection is comparable to that of extended pelvic lymph node dissection when the limitations of the method are taken into consideration.

Aged↗

Cost-effectiveness of routine mediastinoscopy in computed tomography- and positron emission tomography-screened patients with stage I lung cancer.

OBJECTIVE: Accurate preoperative staging is essential for the optimal management of patients with lung cancer. An important goal of preoperative staging is to identify mediastinal lymph node metastasis. Computed tomography and positron emission tomography may identify mediastinal lymph node metastasis with sufficient sensitivity to allow omission of mediastinoscopy. This study utilizes our experience with patients with clinical stage I lung cancer to perform a decision analysis addressing whether mediastinoscopy should be performed in clinical stage I lung cancer patients staged by computed tomography and positron emission tomography. METHODS: We retrospectively reviewed our thoracic surgery database for cases between May 1999 and May 2004. Patients deemed clinical stage I by computed tomography and positron emission tomography were chosen for further study. Individual computed tomography, positron emission tomography, and operative and pathology reports were reviewed. The postresection pathologic staging and long-term survival were recorded. A decision model was created using TreeAgePro software and our observed data for the prevalence of mediastinal lymph node metastases and for the rate of benign nodules. Data reported in the literature were also utilized to complete the decision analysis model. A sensitivity analysis of key variables was performed. RESULTS: A total of 248 patients with clinical stage I lung tumors were identified. One hundred seventy-eight patients (72%) underwent mediastinoscopy before resection, and 5/178 (3%) showed N2 disease. An additional 9 patients were found to have N2 metastasis in the final resected specimen, resulting in a total of 14/248 patients (5.6%) with occult mediastinal lymph node metastases. Benign nodules were found in 19/248 (8%) of patients. Decision analysis determined that mediastinoscopy added 0.008 years of life expectancy at a cost of 250,989 dollars per life-year gained. The outcome was sensitive to the prevalence of N2 disease in the population and the benefit of induction versus adjuvant therapy for N2 lung cancer. If the prevalence of N2 disease exceeds 10%, the sensitivity analysis predicts that mediastinoscopy would lengthen life at a cost of less than 100,000 dollars per life-year gained. CONCLUSION: Patients with clinical stage I lung cancer staged by computed tomography and positron emission tomography benefit little from mediastinoscopy. The survival advantage it confers is very small and is dependent on the prevalence of N2 metastasis and the unproven superiority of induction therapy over adjuvant therapy.

Bromhexine↗

[The significance of computed tomography in ophthalmologic diagnosis. I: The place of computed tomography, indications, study technics, anatomic representation, computed tomography of eyeball and orbital injuries].

CT is recognized today as method of choice for examining pathological conditions of eyeball and orbit. Several techniques of CT examination are needed to attain the most accurate and detailed information about orbital and eyeball lesions. The exact knowledge of the normal anatomic CT feature of orbital structures is necessary. In traumatic lesions of the globe and the orbit foreign bodies, haematomas and fractures of the orbital walls can be proved and localized and traumatic sequelae can be diagnosed.

Eye Foreign Bodies↗

[Quantitative assessment of pulmonary emphysema with computerized tomography. Comparison of the visual score and high resolution computerized tomography, expiratory density mask with spiral computerized tomography and respiratory function tests].

CT is the most accurate method to detect pulmonary emphysema in vivo. We compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined, using the time-honored visual score system, by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT, using a density mask program, at two different cut-off levels (-850, -900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85, versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). Residual lung volume, measured with expiratory spiral CT correlated significantly with residual volume measured with the helium dilution technique (r = 0.66), but CT values were always higher than function results. We believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask. Expiratory studies offer new insights into different normal and abnormal features of COPD and respiratory impairment.

Aged↗