Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TACHYCARDIA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Syncope associated with supraventricular tachycardia. An expression of tachycardia rate or vasomotor response?

BACKGROUND: Syncope in patients with supraventricular tachycardia has been suggested to be an ominous finding, predictive of rapid rates during tachycardia. METHODS AND RESULTS: To explore the mechanism of syncope during supraventricular tachycardia, tachycardia was induced in the supine position and after passive head-up tilting to 60 degrees in 13 patients with atrioventricular (AV) node reentry, eight patients with AV reentry, and one patient with atrial tachycardia. Tilt testing was also performed in sinus rhythm for 30 minutes (the last 15 minutes with isoproterenol infusion). Mean +/- SEM age was 38 +/- 3 years, and 11 patients had a history of syncope (median number of syncopal episodes, three; range, one to 30). The cycle length of tachycardia when upright was shorter than when supine (297 +/- 9 compared with 357 +/- 10 msec, p less than 0.001), and mean blood pressure fell to a greater extent after the onset of tachycardia (fall in mean blood pressure, 53 +/- 6 compared with 24 +/- 3 mm Hg, p less than 0.001). Mean blood pressure correlated significantly with tachycardia cycle length when supine (r = 0.58, p = 0.005) but not when tilted upright (r = 0.18, p = 0.45). Syncope occurred in seven patients during upright tachycardia. These seven patients had a greater fall in mean blood pressure with upright tachycardia than the 15 patients without syncope (fall in mean blood pressure, 70 +/- 4 compared with 45 +/- 5 mm Hg, p = 0.01), but there was no difference in the tachycardia cycle length (311 +/- 10 compared with 290 +/- 11 msec, p = 0.29). Six of the seven patients with tachycardia-induced syncope also had syncope with tilt testing in sinus rhythm compared with four of the 15 patients without tachycardia-induced syncope (p = 0.02). CONCLUSIONS: These data support the view that syncope during supraventricular tachycardia is related to vasomotor factors and does not predict a more rapid tachycardia rate.

Adult↗

The differential diagnosis on the electrocardiogram between ventricular tachycardia and preexcited tachycardia.

The 12-lead surface electrocardiogram is a simple and useful tool for the differential diagnosis of regular wide QRS complex tachycardia. However, criteria do not as yet exist to discriminate between ventricular tachycardia and supraventricular tachycardia with anterograde conduction over an accessory pathway (preexcited tachycardia). Therefore, we designed a new stepwise approach with three criteria for the electrocardiographic differential diagnosis between ventricular tachycardia and preexcited tachycardia and prospectively studied 267 regular tachycardias with electrophysiologically proven mechanism and a wide QRS complex (> or = 0.12 s): 149 consecutive ventricular tachycardias and 118 consecutive preexcited regular tachycardias. Underlying heart disease was old myocardial infarction in 133 of 149 (89%) ventricular tachycardias. The patients presenting with preexcited tachycardia had no additional structural heart disease. Atrial fibrillation with preexcited QRS complex was not included. The criteria favoring ventricular tachycardia were: (1) presence of predominantly negative QRS complexes in the precordial leads V4 to V6, (2) presence of a QR complex in one or more of the precordial leads V2 to V6, and (3) AV relation different from 1:1 (more QRS complexes than P waves). The final sensitivity and specificity of these three consecutive steps to diagnose ventricular tachycardia were 0.75 and 1.00, respectively. This new stepwise approach is sensitive and highly specific for the differential diagnosis between ventricular tachycardia in coronary artery disease and preexcited regular tachycardia.

Coronary Disease↗

Electrocardiographic response of digoxin-toxic fascicular tachycardia to Fab fragments: implications for tachycardia mechanism.

The electrocardiographic response of digoxin-induced fascicular tachycardia to Fab fragments was evaluated in two patients. In addition, we documented the response of the fascicular tachycardia to spontaneous premature ventricular depolarizations during different tachycardia rates, the response to a nonsustained episode of ventricular tachycardia, and the mode of spontaneous initiation and termination of short-lived episodes of the tachycardia during the treatment process. The following findings were noted: slowing of the tachycardia in response to Fab administration; change in the morphologic characteristics of the tachycardia from multiform to uniform; resetting of the tachycardia by spontaneous premature ventricular depolarization with the return cycle equal to the observed tachycardia cycle length; acceleration of the tachycardia in response to five beats of a faster nonsustained ventricular tachycardia; and initiation and termination of the tachycardia, both by spontaneously occurring premature ventricular depolarizations and in the absence of premature ventricular depolarizations. Both tachycardias resolved completely within 20 and 40 minutes, respectively, of Fab administration. We conclude that Fab administration can promptly resolve fascicular tachycardias precipitated by digoxin toxicity and that the observed electrocardiographic phenomena strongly suggest triggered activity as the electrophysiologic mechanism of fascicular tachycardia in man.

Aged↗

Junctional tachycardia: a useful marker during radiofrequency ablation for atrioventricular node reentrant tachycardia.

OBJECTIVES: The aim of this study was to evaluate junctional tachycardia as a useful marker during radiofrequency ablation for atrioventricular (AV) node reentrant tachycardia. BACKGROUND: Junctional tachycardia appears to be a response of the atrioventricular node to injury and is seen during both radiofrequency AV node ablation and slow and fast pathway ablation for AV node reentrant tachycardia. We hypothesized that junctional tachycardia heralding AV node block and that associated with slow or fast pathway ablation may have different characteristics that could be useful in preventing inadvertent AV block. METHODS: Characteristics of junctional tachycardia were examined after 59 radiofrequency ablation sessions in 53 consecutive patients with a mean age (+/- SD) of 41.6 +/- 16.5 years. Type 1 junctional tachycardia was followed by transient second- or third-degree AV block (n = 5) or permanent third-degree AV block (n = 1). Type 2 junctional tachycardia was followed by normal AV conduction (n = 53). RESULTS: Fifty-one patients had typical AV node reentrant tachycardia, and two patients had atypical tachycardia. Fast pathway ablation was attempted during 6 sessions and slow pathway ablation during 53 sessions. Patients underwent 15.3 +/- 10 radiofrequency applications, with a mean duration of 24 +/- 9.7 s. Junctional tachycardia was observed an average of 2.8 +/- 1.8 times per ablation session. Type 1 junctional tachycardia had a significantly faster rate than that of type 2 (cycle length 363 +/- 44 vs. 558 +/- 116, p < 0.001). In addition, type 1 junctional tachycardia was associated with predominantly ventriculoatrial block whereas type 2 was associated with predominantly 1:1 ventriculoatrial conduction (2 of 6 vs. 47 of 53 episodes, p < 0.05). CONCLUSIONS: We conclude that junctional tachycardia leading to AV block can be recognized by a faster junctional rate and ventriculoatrial block. This is a useful marker of impending AV block during slow and fast pathway ablation.

Adult↗

Antidromic tachycardia utilizing decremental, latent accessory atrioventricular fibers: differentiation from adenosine-sensitive ventricular tachycardia.

OBJECTIVES: We studied two patients with latent, decremental atrioventricular (AV) fibers in whom pre-excitation could be demonstrated only during wide complex tachycardia. BACKGROUND: The presence of decremental AV fibers participating in antidromic AV reentrant tachycardia is usually suspected by the presence of pre-excitation either in sinus rhythm or during atrial pacing. METHODS: Two patients were referred for evaluation and treatment of wide complex tachycardia whose configuration suggested ventricular tachycardia that could be terminated with adenosine infusion. They underwent standard electrophysiologic studies. RESULTS: Baseline AH and HV intervals were normal. No pre-excitation was noted with atrial overdrive at multiple sites or during atrial extrastimulation. Retrograde conduction was present with a sequence compatible with AV node conduction. Sustained wide complex tachycardia was induced with ventricular overdrive pacing. Late atrial premature depolarizations during tachycardia pre-excited the subsequent ventricular activation. Earlier atrial premature depolarizations delayed the subsequent ventricular activation. In one patient, early atrial premature depolarizations terminated the tachycardia without activating the ventricle. In the other patient, spontaneous tachycardia termination was accompanied by ventriculoatrial block. The earliest ventricular activation was at the annulus in the posteroseptal region in one patient and at the left posterior region in the other. Atrioventricular node reentry and atrial tachycardia with bystander AV fibers were also excluded. These findings establish the diagnosis of antidromic AV reentrant tachycardia utilizing a slow, decrementally conducting AV pathway. CONCLUSIONS: This is the first report describing the presence of latent, decremental accessory AV pathways in which conduction was manifest only during antidromic AV reentrant tachycardia. To differentiate these wide complex tachycardias from adenosine-sensitive ventricular tachycardia, we recommend that atrial premature depolarizations be applied during tachycardia to rule out the presence of a latent, decremental AV fiber even in patients who do not otherwise have pre-excitation with atrial pacing techniques.

Adenosine↗

Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator.

OBJECTIVES: This study was conducted to evaluate criteria for discrimination of ventricular tachycardia from atrial fibrillation and sinus tachycardia in a tiered-therapy cardioverter-defibrillator (Medtronic PCD). BACKGROUND: Interval stability algorithms discriminate ventricular tachycardia from atrial fibrillation. Onset algorithms discriminate ventricular tachycardia from sinus tachycardia. Neither has been validated clinically. METHODS: The stability criterion requires that a ventricular tachycardia interval not vary from any of the three previous intervals by more than the programmable stability value. The onset criterion detects initiation of ventricular tachycardia only if the ratio of an interval to the mean of four previous intervals is less than a programmed onset ratio and either the second or third preceding interval exceeds the ventricular tachycardia detection interval. We evaluated these criteria in 100 patients at electrophysiologic study and exercise testing (65 patients) and during a mean (+/- SD) follow-up of 16.2 +/- 7.9 months. The PCDs were programmed to tiered therapy in 54 patients. In the remaining 46 patients, the PCD's memory for detected ventricular tachycardia was used to study the specificity of the chosen onset criterion for rejecting sinus tachycardia. We used stored intervals preceding appropriate (n = 99) and inappropriate (n = 54) detections to test a new onset criterion that was less sensitive to a single index interval. RESULTS: Programmed stability of 40 ms decreased detection of induced atrial fibrillation by 95% (20 patients), paroxysmal atrial fibrillation by 95% (6 patients) and chronic atrial fibrillation by 99% (9 patients); all episodes of spontaneous (n = 877) and induced (n = 339) ventricular tachycardia were detected. A programmed onset ratio of 87% rejected sinus acceleration (98%) but caused underdetection of 0.5% of ventricular tachycardias. The onset criterion permitted inappropriate detection of premature ventricular complexes during sinus tachycardia, but the new criterion reduced these inappropriate detections by 98%. CONCLUSIONS: The PCD's onset and stability criteria reduced inappropriate detection of atrial fibrillation and sinus acceleration while detecting 99.5% of ventricular tachycardias.

Aged↗

Ventricular tachycardia as default diagnosis in broad complex tachycardia.

In the differential diagnosis of broad-complex tachycardia, the most important decision is whether or not the tachycardia is ventricular, since this type carries the worst prognosis. However, the rules for a diagnosis of ventricular tachycardia are so complex that they are not satisfied in many cases, and the default diagnosis, supraventricular tachycardia, is erroneously accepted. We sought to reverse this strategy; unless simple rules for a positive diagnosis of supraventricular tachycardia were satisfied, ventricular tachycardia was diagnosed by default. The criterion for a diagnosis of supraventricular tachycardia was electrocardiographic (ECG) findings typical of bundle branch block (left = rS or QS wave in leads V1 and V2, delay to S wave nadir < 70 ms, and R wave and no Q wave in lead V6; right = rSR' wave in lead V1 and an RS wave in lead V6, with R wave height greater than S wave depth). Twelve-lead ECGs were done for 102 consecutive patients with broad-complex tachycardia (QRS width > 110 ms). Two observers, who were unaware of definitive diagnoses validated by electrophysiology, by our diagnostic rules made correct diagnosis of ventricular tachycardia in 63 and 62 of 69 patients, respectively, and correct diagnoses of supraventricular tachycardia in 28 and 22 of 33 patients (sensitivity for ventricular tachycardia 90% and 91%, specificity 67% and 85%). One observer then sought independent P waves in cases diagnosed as supraventricular tachycardia; sensitivity for the diagnosis of ventricular tachycardia rose to 96%, with a specificity of 64%. These criteria, which require only knowledge of typical bundle branch block patterns, were highly sensitive for the important diagnosis of ventricular tachycardia.

Diagnosis, Differential↗

Differentiation of sinus tachycardia from paroxysmal 1:1 tachycardias using single late diastolic atrial extrastimuli.

Existing antitachycardia devices do not discriminate perfectly between sinus tachycardia and paroxysmal tachycardias with 1:1 atrioventricular relationship (paroxysmal 1:1 tachycardias). The present study tested the hypothesis that the nature of the ventricular response to atrial extrastimulation might distinguish between sinus tachycardia and selected paroxysmal 1:1 tachycardias. In 15 patients, atrial extrastimuli were delivered during sinus tachycardia and in 13 patients during various types of paroxysmal 1:1 tachycardia, and the timing of the next ventricular beat was measured. During sinus tachycardia, in 14 of 15 patients, atrial extrastimuli which were, in turn, early by 80 and 100 ms made the next ventricular beat premature by at least 30 and 50 ms, respectively. In all 13 patients, during paroxysmal 1:1 tachycardia, atrial extrastimuli that were early by 80 and 100 ms failed to make the next ventricular beat premature by more than 10 ms. Single atrial extrastimuli that were premature by less than or equal to 100 ms did not provoke faster tachycardias in any of the patients. In this study, a technique that used single late extrastimuli during tachycardia safely distinguished sinus tachycardia from paroxysmal tachycardias. This technique might be suitable for incorporation into an antitachycardia device. Further investigation of this technique is warranted in a larger number of patients with a wider variety of tachycardias. Patients with Gemini 415As having dual anodal rings, which can be identified radiographically, are at risk for this design-dep design-dependent cross-talk and merit close observation.

Adolescent↗

Determinants of tachycardia induction using ventricular stimulation in dual pathway atrioventricular nodal reentrant tachycardia.

Factors determining tachycardia induction using ventricular stimulation in atrioventricular (AV) nodal reentrant tachycardia utilizing the slow pathway for anterograde and the fast pathway for retrograde conduction were analyzed in 53 patients. Sixteen patients had tachycardia induced by ventricular stimulation. In 15, tachycardia was inducible with incremental ventricular pacing. In 4 of these 15 patients, the tachycardia was also induced with V1V2 testing, while in 11 patients, the tachycardia was not induced with V1V2 testing. In 9 of the latter 11 patients, tachycardia could be induced with V1V2V3 testing, suggesting that the retrograde effective refractory period (ERP) of the right bundle (RB) or the relative refractory period of the His-Purkinje system (HPS) was the limiting factor for tachycardia induction during V1V2 testing. In the remaining one patient, tachycardia was induced with V1V2V3 testing, which provoked a premature ventricular beat, leading to tachycardia induction. Tachycardia was not induced by ventricular stimulation in 37 patients. Factors deterring tachycardia induction in these patients may be related to the retrograde ERP or functional refractory period (FRP) of the HPS, the retrograde ERP of the fast pathway, and an insufficient conduction delay of the circuit (retrograde fast and anterograde slow pathway) to allow anterograde conduction of the slow pathway. In conclusion, AV nodal reentrant tachycardia can be induced by ventricular stimulation in approximately 30% of patients with incremental ventricular pacing and/or ventricular extrastimulus testing. Induction of tachycardia with ventricular stimulation, nevertheless, is frequently limited by the retrograde FRP or ERP of the HPS, the retrograde ERP of the fast pathway, and possibly by an insufficient conduction delay of the circuit.

Adolescent↗

Nonsustained ventricular tachycardia in coronary artery disease: relation to inducible sustained ventricular tachycardia. MUSTT Investigators.

BACKGROUND: Many physicians believe that electrocardiographic characteristics of nonsustained ventricular tachycardia correlate with the risk for sudden death in survivors of myocardial infarction. Sustained ventricular tachycardia induced by programmed electrical stimulation has also been shown to predict sudden death. OBJECTIVE: To determine whether electrocardiographic characteristics of spontaneous nonsustained ventricular tachycardia can predict the inducibility of sustained ventricular tachycardia by programmed electrical stimulation in patients with coronary artery disease having abnormal ventricular function. DESIGN: Observational cohort study. SETTING: 70 clinical electrophysiology laboratories in the United States and Canada. PATIENTS: 1480 consecutive patients with coronary artery disease, left ventricular ejection fraction of 0.40 or less, and asymptomatic nonsustained ventricular tachycardia. INTERVENTION: Electrophysiologic study attempting to induce sustained monomorphic ventricular tachycardia. MEASUREMENTS: Daily frequency, duration, and cycle length of spontaneous episodes of nonsustained ventricular tachycardia, measured by standard electrocardiographic recordings. RESULTS: No statistically significant difference in the frequency or duration of spontaneous nonsustained ventricular tachycardia was seen between patients with and those without inducible sustained ventricular tachycardia. Rates of spontaneous tachycardia were slightly slower in patients with inducible ventricular tachycardia than in patients without inducible ventricular tachycardia (P = 0.047), but the difference was not clinically significant. CONCLUSION: Electrocardiographic characteristics of spontaneous nonsustained ventricular tachycardia do not predict which patients with coronary artery disease will have inducible sustained ventricular tachycardia.

Coronary Disease↗

Atypical atrioventricular nodal reentry tachycardia with atrioventricular block mimicking atrial tachycardia: electrophysiologic properties and radiofrequency ablation therapy.

INTRODUCTION: Fast-intermediate form AV nodal reentry tachycardia (AVNRT) sometimes may mimic atrial tachycardia or atrial flutter and render the diagnosis difficult when the tachycardia rate is fast and AV block occurs during tachycardia. METHODS AND RESULTS: A 45-year-old woman with paroxysmal supraventricular tachycardia was referred to this institution. Initially, the tachycardia was thought to be an atrial tachycardia because of: (1) a short cycle length of the tachycardia with 2:1 and Wenckebach AV block; (2) a difference in the atrial activation sequence during tachycardia and during ventricular pacing; and (3) failure of burst ventricular pacing to affect the atrial rate and the atrial activation sequence during tachycardia. An accurate diagnosis of fast-intermediate form AVNRT was subsequently made based on the finding that the tachycardia was induced following delivery of a third ventricular extrastimulus, which showed a sequence of V-A-H and a change on atrial activation sequence of the induced beat. Successful radiofrequency ablation was achieved only after accurate diagnosis of the tachycardia was made. CONCLUSION: Fast-intermediate form AVNRT sometimes may masquerade as atrial tachycardia. Accurate diagnosis is mandatory for successful ablation therapy.

Catheter Ablation↗

Entrainment of ventricular tachycardia by AV nodal reentrant tachycardia.

Endocardial recordings from a patient with both sustained ventricular tachycardia and AV nodal reentrant tachycardia are presented that demonstrate spontaneous transient entrainment of ventricular tachycardia by AV nodal reentrant tachycardia. During electrophysiological catheterization, there were repeated episodes of spontaneous conversion from a wide to a narrow QRS morphology following the induction of ventricular tachycardia. With conversion from the wide to the narrow QRS, the ventricular deflection in the coronary sinus electrograms demonstrated an abrupt change in morphology, indicating a change in activation sequence at this site from the wavefront of depolarization emerging from the ventricular tachycardia circuit to a wavefront conducting over the His-Purkinje system. However, the right ventricular apex electrogram demonstrated a constant morphology with a decrease in cycle length equal to that of the other intracardiac electrograms, indicating a constant direction of activation from the ventricular tachycardia circuit, and that ventricular tachycardia had been transiently entrained by AV nodal reentrant tachycardia. In addition, rapid atrial pacing during ventricular tachycardia narrowed the QRS and demonstrated transient entrainment of the right ventricular apex electrogram. Although transient entrainment of a tachycardia is evidence supporting reentry with an excitable gap as the probable mechanism, its demonstration has required the use of rapid pacing techniques. This case is a spontaneously occurring example of transient entrainment of one tachycardia circuit by another, a phenomenon that has not been previously described.

Aged↗

Value of the 12-lead electrocardiogram in discriminating atrioventricular nodal reciprocating tachycardia from circus movement atrioventricular tachycardia utilizing a retrograde accessory pathway.

The value of the 12-lead electrocardiogram for distinguishing atrioventricular (AV) nodal reciprocating tachycardia from circus movement AV tachycardia utilizing a retrograde accessory pathway was studied in 100 patients with narrow QRS complex tachycardia. Intracardiac electrograms showed AV nodal reciprocating tachycardia in 40 patients and circus movement AV tachycardia in 60. The 12-lead electrocardiograms recorded during tachycardia were randomly sorted and reviewed by 4 experienced cardiac electrophysiologists who were blinded to the diagnosis associated with each tracing, the relative proportion of each arrhythmia and the hypotheses to be tested. Each reviewer was asked to indicate the location of the P wave relative to the QRS complex, electrical axis of the P wave in the frontal and horizontal planes and presence or absence of QRS alternation, and to interpret the most likely mechanism. The performance of published electrocardiographic criteria to differentiate AV nodal reciprocating tachycardia from circus movement AV tachycardia was evaluated. The overall accuracy of the reviewers' interpretations was 75%, similar to the accuracy of the predefined criteria when applied by these observers (71% correct, difference not significant). Interobserver agreement of reviewer interpretations was 76% and the intraobserver agreement was 78%. Features associated with circus movement AV tachycardia by univariable analysis were P waves after the QRS complex, faster tachycardia rates and QRS alternation. Multivariable analysis showed that only the location of the P wave relative to the QRS complex was independently associated with the mechanism of tachycardia (p = 0.002). QRS alternation was found by multivariate analysis to be associated with the rate but not the mechanism of the tachycardia.

Diagnosis, Differential↗

Effect of atrial pacing on the frequency of tachycardia in patients with recurrent junctional tachycardia.

In order to assess whether atrial pacing reduced the frequency of tachycardia in patients with recurrent junctional tachycardias, ten patients with recurrent junctional tachycardias with atrial Intertach antitachycardia pacemakers in situ were paced in a random order in atrial demand mode at 50 ppm (AAI 50), 80 ppm (AAI 80), and 100 ppm (AAI 100) for a period of up to 1 month. The numbers of tachycardias detected by the pacemaker over this period were recorded and compared with the number seen when unpaced (000). Correct arrhythmia detection by the pacemaker was confirmed by Holter monitoring. The number of tachycardias in 000 was 44.7 +/- 19.8 (mean +/- SEM). No significant reduction in tachycardia frequency was seen in any pacing mode. Back-up atrial pacing at 50 ppm tended to reduce the frequency of tachycardias (32.3 +/- 12.8 tachycardias; P = 0.06). The higher pacing rates increased the number of tachycardias (AAI 80; 57.1 +/- 24.6 tachycardias, P = 0.20: AAI 100; 81.8 +/- 30.2 tachycardias; P = 0.31). Symptoms increased with each pacing mode and palpitations were statistically more severe in AAI 100 mode. Four patients had disabling symptoms at this rate and had to drop out. Atrial back-up pacing may be of use in some patients with junctional tachycardia, but overdrive pacing is not helpful.

Adult↗

Cycle length alternation in circus movement tachycardia using an atrioventricular accessory pathway. A study of the role of the atrioventricular node using a computer model of tachycardia.

The possible role of the atrioventricular nodal (AVN) function curve during tachycardia as a cause of cycle length alternation was investigated using a computer model of circus movement tachycardia utilizing an atrioventricular accessory pathway. Two types of AVN function curves during tachycardia were entered into the computer: straight lines of various gradients and representative examples of patient-based AVN function curves obtained during clinical electrophysiologic studies. Perturbations of the tachycardia model were induced by introducing a short cycle, by suddenly prolonging a conduction interval, or by moving the AVN function curve relative to that in stable tachycardia. Using the straight line AVN function curves, stable, sustained cycle length alternation could be induced by perturbation of the tachycardia cycle if the gradient of the line was -1 (slope = 45 degrees). If the gradient was more than -1 (slope less than 45 degrees), the perturbation was damped. If the gradient was less than -1 (slope greater than 45 degrees), the perturbation was amplified, leading to termination of tachycardia by block in the AVN. Similar but more complex responses to perturbation of tachycardia were found using patient-based AVN function curves. Thus, sustained cycle length alternation and amplification or damping of perturbation could be produced. Using physiologic AVN function curves, the response to perturbation of tachycardia depended on the interrelationship of the shape of the AVN function curve, the location of the cycle length of tachycardia on the curve, the magnitude and direction of the perturbation, and the AVN effective refractory period. We conclude that cycle length alternation during tachycardia may be explained by the characteristics of a single antegrade AVN function curve without postulating the presence of additional AVN pathways. The stability of circus movement tachycardias depends on the interaction of several variables.

Atrioventricular Node↗

Demonstration of the presence of slow conduction during sustained ventricular tachycardia in man: use of transient entrainment of the tachycardia.

To test the hypothesis that an area of slow conduction is present during reentrant ventricular tachycardia in man, and that the earliest activation site during ventricular tachycardia is within or orthodromically just distal to the area of slow conduction in the reentry loop, we studied 12 episodes of ventricular tachycardia (mean rate 185 +/- 32 beats/min) that were induced in nine patients with ischemic heart disease. Rapid ventricular pacing was performed at selected sites during ventricular tachycardia while recording electrograms from an early activation site relative to the onset of the QRS complex (site A) and from a site close to the pacing site (site B). Rapid pacing from the right ventricular apex during ventricular tachycardia with a right bundle branch block pattern and from selected left ventricular sites during ventricular tachycardia with a left bundle branch block pattern (mean pacing rate 202 +/- 38 beats/min) resulted in constant ventricular fusion beats on the electrocardiogram except for the last captured beat (i.e., the ventricular tachycardia was entrained) in 11 of 12 episodes. During entrainment: sites A and B were activated at the pacing rate, conduction time from the last pacing impulse to the last captured ventricular electrogram at site A (St-A interval) was 359 +/- 69 msec and spanned the diastolic interval, while that at site B (St-B interval) was only 28 +/- 13 msec, site A had the same ventricular electrogram morphology as that during ventricular tachycardia, while site B had a different electrogram morphology, indicating that site A was activated in the same direction during entrainment as during ventricular tachycardia. Eight episodes of ventricular tachycardia were entrained at two or more different pacing rates. The St-A interval increased during pacing at the faster rate(s) in four of eight episodes, while the St-B interval remained unchanged. Rapid ventricular pacing performed from the same site during sinus rhythm (mean pacing rate 201 +/- 37 beats/min) resulted in an St-A interval of 103 +/- 37 msec (p less than .001 vs the value during entrainment) and an St-B interval of 31 +/- 15 msec (p = NS vs the value during entrainment). It is concluded that an area of slow conduction not demonstrable during sinus rhythm exists during ventricular tachycardia, and that the earliest activation site during ventricular tachycardia is at or orthodromically distal to this area of slow conduction.

Aged↗

Diagnostic value of tachycardia features and pacing maneuvers during paroxysmal supraventricular tachycardia.

OBJECTIVES: The purpose of this prospective study was to quantitate the diagnostic value of several tachycardia features and pacing maneuvers in patients with paroxysmal supraventricular tachycardia (PSVT) in the electrophysiology laboratory. BACKGROUND: No study has prospectively compared the value of multiple diagnostic tools in a large group of patients with PSVT. METHODS: One hundred ninety-six consecutive patients who had 200 inducible sustained PSVTs during an electrophysiology procedure were included. The diagnostic values of four baseline electrophysiologic parameters, nine tachycardia features and five diagnostic pacing maneuvers were quantified. RESULTS: The only tachycardia characteristic that was diagnostic of atrioventricular (AV) nodal reentry was a septal ventriculoatrial (VA) time of <70 ms, and no pacing maneuver was diagnostic for AV nodal reentry. An increase in the VA interval with the development of a bundle branch block was the only tachycardia characteristic that was diagnostic for orthodromic tachycardia, but it occurred in only 7% of all tachycardias. An atrial-atrial-ventricular response upon cessation of ventricular overdrive pacing was diagnostic of atrial tachycardia, and this maneuver could be applied to 78% of all tachycardias. Burst ventricular pacing excluded atrial tachycardia when the tachycardia terminated without depolarization of the atrium, but the result could be obtained only in 27% of patients. CONCLUSIONS: This prospective study quantitates the diagnostic value of multiple observations and pacing maneuvers that are commonly used during PSVT in the electrophysiology laboratory. The findings demonstrate that diagnostic techniques rarely provide a diagnosis when used individually. Therefore, careful observations and multiple pacing maneuvers are often required for an accurate diagnosis during PSVT. The results of this study provide a useful reference with which new diagnostic techniques can be compared.

Adolescent↗

[Anti-tachycardia stimulation in supraventricular and ventricular tachycardia with and without cardioverter/defibrillator].

Reentry is the underlying electrophysiologic mechanism in most of the clinically occurring tachycardias. It has been known for 25 years that a reentrant circuit can be interrupted by correctly timed stimuli during programmed stimulation. Although there has been a continuous technological progress in pacemaker technology in the last ten years, application of pacemaker therapy for the treatment of atrial as well as of ventricular tachyarrhythmias did not increase significantly. Prophylactic permanent pacing preventing the onset of tachyarrhythmias has not become an accepted therapeutic approach and is still a matter of research. Antitachycardia pacing designed to interrupt a reentrant circuit uses single or multiple extrastimuli which invade the excitable gap of the reentrant circuit so that antegrade and retrograde conduction within the circuit becomes impossible. The excitable gap, however, is not a fixed electrophysiological parameter, but its width depends mainly on the influence of the sympathetic and parasympathetic nervous system. Therefore, a variety of stimulation programs delivered by the implanted pacemaker had to be invented in order to adapt to the constantly changing electrophysiologic parameters. It becomes obvious that application of burst stimulation is more effective than delivery of single or double extra stimuli and that tachycardia rate-related pacing is more reliable than fixed-rate pacing for tachycardia interruption. The most effective termination mode seems to be self-adaptive auto-decremental pacing with constantly decreasing intervals between multiple stimuli and addition of further impulses for each new termination attempt. The risk of acceleration of tachycardia or induction of non-clinical tachyarrhythmias is higher with burst-stimulation than with single or double extra stimuli. Fast tachycardia rates are more prone to acceleration than slower ones. Tachycardia detection algorithms are based mainly on rate, sudden onset and rate stability of the tachycardia. In order to reliably distinguish pathologic tachycardias from sinus or physiologic tachycardias, other than rate-detection parameters will be applied in the future. These are endocardial electrogram signal-analysis, frequency content of the endocardial signals as well as biological sensors. A prerequisite for successful permanent antitachycardia pacing is a thoroughly performed preoperative electrophysiologic study in order to identify the most reliable and effective tachycardia termination mode. This requires multiple induction of the clinical tachycardia under various conditions, different activity or posture states as well as under the influence of antiarrhythmic drugs.(ABSTRACT TRUNCATED AT 400 WORDS)

Electric Countershock↗