Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spontaneous Combustion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Determination of the initial exothermic reaction of shredded tyres with wire content.

This paper presents the cause of exothermic reactions in shredded tyre with exposed wire content in shredded tyre piles. Data indicate that the oxidation of exposed steel wires is the exothermic reaction in shredded tyre embankments. This would lead to spontaneous combustion. Reaction of the steel with the sulphur or the carbon black appears not to be the source of the exothermic. Laboratory tests have been conducted to determine the heat transfer properties of the materials that compose tyres (i.e., tyre rubber and wires) by using a hot-plate apparatus. In addition, one-dimensional heat conduction experiments were conducted to compare the flow of heat through the materials while varying the physical and environmental conditions. The physical conditions were the size of tyre shred, water content, and wire contents. An exothermic reaction occurred when exposed wire was present but not when it was absent. A one-dimensional heat transfer equation was developed, and parametric studies were conducted to verify the laboratory model. Exothermic reaction was found to increase linearly with temperature, size and shape of the shredded tyres, density, amount of wire in shredded tyres, and water content.

Fourier Analysis↗

Development of calcium phosphate based functional gradient bioceramics.

A functional gradient bioceramic that can function gradually with respect to body tissue was studied by changing the composition of calcium phosphate gradually from the surface to the inside. Diamond powder was spread on the surface of compact hydroxyapatite (HA) powder and fired at 1280 degrees C under reduced pressure, followed by firing under atmospheric conditions. The sintered body thus prepared was dense and alpha-tricalcium phosphate (alpha-TCP: alpha-Ca3(PO4)2) was found on its surface. The content of alpha-TCP gradually decreased with increasing depth from the surface. In contrast, the content of HA increased with increasing depth from the surface. The gradient ratio of alpha-TCP and HA depends on the firing time for each condition, i.e. reduced or atmospheric pressure. The alpha-TCP formation was ascribed to the decomposition of HA due to the spontaneous combustion of diamond powder.

Biocompatible Materials↗

'Special effects' burn injuries.

Three patients are presented with significant flame burns, resulting from accidents occurring during 'special effects' situations in the entertainment industry. These occurred as a result of the spontaneous combustion of various materials, during events in live theatre (gun powder), a television commercial (artificial 'rocket fuel'), and a video presentation (magnesium oxide). All three patients sustained flash burns to the face and hands. One patient sustained a significant bilateral corneal injury, a gamekeeper's thumb, and a permanent continuous right-sided high frequency tinnitus, in addition to his burn injury. Photographic documentation of all three patients is presented. The total loss of time from work for all patients was 6 months. All these injuries were potentially preventable.

Accidents, Occupational↗

Effect of geological processes on coal quality and utilization potential: review with examples from western Canada.

This review article compares the elemental and radionuclide concentrations in coals from western Canada, the vast majority of which are used for power generation in Alberta. The coals range in age from lower Cretaceous to middle Eocene, and in rank from subbituminous to high volatile bituminous. Some of the coals were deposited in deltaic lagoonal to marine settings while others formed under lacustrine conditions in intermontane graben settings or in alluvial plains. The role of source rock (provenance), depositional environment, tectonic regime and hydrologic conditions on elemental concentration and distribution will be discussed, with specific examples from western Canada. In addition, the effect of natural weathering, igneous intrusion and self-burning (spontaneous combustion) on the enrichment and/or depletion of elements will be presented. The emphasis throughout this review article will be on the fate of elements of environmental concern and interest (e.g. As, Ba, B, Cl, Co, Cr, Cu, Mn, Mo, Se, Th, U, V and Zn) and of radionuclides of the U and Th series upon coal utilization. This article is also intended for those not familiar with the geological or environmental sciences, particularly as related to fossil fuel utilization.

Alberta↗

Chemical incident management: gaseous emissions from a stockpile of coal.

Spontaneous combustion of coal releases a wide range of airborne pollutants which, in high concentrations, may be hazardous to health. Little is known about how the effects on health change in relation to the release of multiple substances. This article reports an incident in which a stockpile of coal released potentially harmful gases into the environment. Although the resultant health effects reported were few, the co-ordinated response by local authorities and health authorities highlighted the advantage of a multidisciplinary approach. Public health departments need to be aware of major chemical hazards within their district. Prompt environmental monitoring and exposure measurement needs to be arranged as this is crucial to making an appropriate response. Updated registers are needed from private companies and public bodies; who can provide timely measurements of chemical hazards. Health districts with more than one local authority may benefit from pooling resources and knowledge in order to prepare for such an incident.

Air Pollutants↗

Use of a surrogate aerosol in a preliminary screening for the potential carcinogenicity of coal coated with No. 6 fuel oil.

Coal, which contains significant amounts of water, can be ground and dried to produce an efficient fuel for electric power plants; however, spontaneous combustion can occur in the dried coal. Liquid petroleum hydrocarbons inhibit this combustion, but not all petroleum streams are effective. No. 6 fuel oil, a readily available and inexpensive stream, provides an effective coating, but the carcinogenic potential of coal particles treated with No. 6 fuel oil, which contains polynuclear aromatic hydrocarbons (PNAs), was undefined. As part of the assessment process, a series of studies was conducted to compare this treated coal with similar particles (petroleum coke) that had been tested by chronic inhalation in monkeys and rats. The amounts of PNAs in petroleum coke and treated coal were compared in extraction studies; the treated coal had only two-thirds of the organics extractable with benzene compared with coke and only 7% as much of the 3-7 ring PNAs, the likely tumorigenic compounds. In addition, the analytical profile of 3-7 ring PNAs was of lower molecular weights in the coal treated with fuel oil. The mutagenicity of extracts from treated coal was much less than with petroleum coke and markedly less than that of No. 6 fuel oil itself. The percutaneous absorption of 3H-benzo(a)pyrene from both particles and from their benzene extracts, as measured in vitro, was approximately eight times greater with petroleum coke than with treated coal. Based on these preliminary results, there is no evidence suggesting that the treated coal would pose any greater carcinogenic risk than petroleum coke.

Aerosols↗

Synthesis and characterization of uncapped gamma-Fe2O3 nanoparticles prepared by flame pyrolysis of ferrocene in ethanol.

Nanoparticles of iron(III) oxide were synthesized by spontaneous combustion of ferrocene in ethanol solution using a simple spirit lamp. X-ray powder diffraction and electron diffraction analysis of the powder suggested the formation of gamma-Fe2O3 (Maghemite phase) having lattice constant 8.3539 +/- 0.0209 A. Transmission Electron Micrograph suggested the formation of spherical particles with an average diameter of 24.7 +/- 1.6 nm. A sextet with an isomeric shift of 0.328 mm s(-1) seen in the Mossbauer spectrum recorded at room temperature, further supports the formation of gamma-Fe2O3. The particles were dispersed freely in the polar solvents like ethanol, dimethyl sulfoxide, and water. Infra Red spectrum gave bands at 400, 432, 565, and 638 cm(-1), which confirms the presence of gamma-Fe2O3 phase.

Crystallization↗

White phosphorus poisoning--explosive encounter.

Poisoning by white or yellow phosphorus is reported in various forms and also in ages varying from infants to adults, but spontaneous combustion and explosion during its management has never been described. This incidence occurred while attempting to pass a Ryle's tube. Its free end first exhibited a yellow flame and this later on led to an explosive encounter. Role of static electricity generated while handling plastic materials leading to ignition and explosion cannot be overlooked.

Adolescent↗

[The "Mining Rescue System and Mine Fires" Working Group. Tasks, results, future activities].

The president of the working party presents details of its principal tasks in the past and in the present time. These can be summed up in a study of the problems mentioned below and the subsequent elaboration of recommendations for the benefit of the governments, guidelines, information reports and research proposals. The principal problems that were or are still under study are: --prevention of fires: shaft equipment, hydraulic fluids, belt conveyors, . . .; --detection of mine fires and spontaneous combustion; --fighting of mine fires: shaft fires, construction of stoppings, openings and recovering of fire zones, . . .; --coordination and rescue equipment: escape and rescue breathing apparatus, flameproof clothing, rescue of trapped miners; --stabilization of ventilation in the event of fire, . . . The speaker stresses the importance of the information exchange and the atmosphere of fellowship and solidarity that prevails in the working party.

Belgium↗

Experiments in the combustibility of the human body.

This paper provides possible explanations for two previously misunderstood circumstances surrounding cases of so-called "spontaneous human combustion"--the nearly complete cremation of human bone, and the failure of such fires to spread to nearby combustibles. Two experiments were conducted. The first involved the cremation of "healthy" and "osteoporotic" human bone and observing the resulting fragmentation and color change. Osteoporotic elements consistently displayed more discoloration and a greater degree of fragmentation than healthy ones. The second experiment involved the combustion of a sample of human tissue and observation of the flame height and burning area in order to calculate the effective heat of combustion. The resulting heat was 17kJ/g indicating a fire that is unlikely to spread. These results, which are among the first obtained for human samples, lend further support and credence to previous scientific explanations for "spontaneous human combustion."

Body Composition↗

Effects of instilled combustion-derived particles in spontaneously hypertensive rats. Part II: Pulmonary responses.

A consistent association between exposure to high concentrations of ambient particulate matter (PM) and excess cardiopulmonary-related morbidity and mortality has been observed in numerous epidemiological studies, across many different geographical locations. To elicit a similar response in a controlled laboratory setting, spontaneously hypertensive rats were exposed to an oil combustion-derived PM (HP-12) and monitored for changes in pulmonary function and indices of pulmonary injury. Rats were implanted with radiotelemeters to monitor electrocardiogram, heart rate, systemic arterial blood pressure, core temperature, and activity. Animals were divided into four groups and exposed via intratracheal instillation (IT) to suspensions of HP-12 (0.0, 0.83, 3.33, and 8.33 mg/kg; control, low, mid, and high dose, respectively) in saline vehicle. Telemetered rats were monitored continuously for 4-7 days post-IT and pulmonary function was examined using a whole-body plethysmograph system for 6 h/day on post-IT days 1-7. At 24, 96, and 192 h post-IT, bronchoalveolar lavage fluid (BALF) was obtained from subsets of nontelemetered animals in order to assess the impact of HP-12 on biochemical indices of pulmonary inflammation and injury. Immediate dose-related changes in pulmonary function were observed after HP-12 exposure, consisting of decreases in tidal volume (decreasing 12-41%) and increases in breathing frequency (increasing 52-103%), minute ventilation (increasing 12-25%), and enhanced pause (increasing 113-187%). These functional effects were resolved by 7 days post-IT, although some average BALF constituents remained elevated through day 7 for mid- and high-dose groups when compared to those of the saline-treated control group. This study demonstrates significant deficits in pulmonary function, along with significant increases in BALF indices of pulmonary inflammation and injury in SH rats after IT exposure to HP-12.

Air Pollutants↗

Effects of instilled combustion-derived particles in spontaneously hypertensive rats. Part I: Cardiovascular responses.

Epidemiological studies have reported statistically significant associations between the levels of ambient particulate matter (PM) and the incidence of morbidity and mortality, particularly among persons with cardiopulmonary disease. While similar effects have been demonstrated in animals, the mechanism(s) by which these effects are mediated are unresolved. To further investigate this phenomenon, the cardiovascular and thermoregulatory effects of an oil combustion-derived PM (HP-12) were examined in spontaneously hypertensive (SH) rats. The particle used in this study had considerably fewer water-soluble metals than the residual oil fly ash (ROFA) particles widely used in previous animal toxicity studies, with Zn and Ni constituting the primary water-leachable elements in HP-12. Rats were surgically implanted with radiotelemeters capable of continuously monitoring electrocardiogram (ECG), heart rate (HR), systemic arterial blood pressure (BP), and core temperature (T(co)). Animals were divided into four dose groups and were administered one of four doses of HP-12 suspended in saline vehicle (0.00, 0.83, 3.33, 8.33 mg/kg; control, low, mid, and high dose, respectively) via intratracheal instillation (IT). Telemetered rats were monitored continuously for up to 7 days post-IT, and were sacrificed 4 or 7 days post-IT. Exposures to mid- and high-dose HP-12 induced large decreases in HR (decreasing 30-120 bpm), BP (decreasing 20-30 mmHg), and T(co) (decreasing 1.2-2.6 degrees C). The decreases in HR and BP were most pronounced at night and did not return to pre-IT values until 72 and 48 h after dosing, respectively. ECG abnormalities (rhythm disturbances, bundle branch block) were observed primarily in the high-dose group. This study demonstrates substantial dose-related deficits in cardiac function in SH rats after IT exposure to a low-metal content, combustion-derived particle.

Air Pollutants↗

[Combustion characteristics of mixed municipal solid waste in thermogravimetric analysis and lab scale fluidized bed].

In this paper, thermogravimetric analysis (TGA) and a lab scale fluidized bed facility were used as experimental means. The data in the two different experimental systems were introduced and compared. Experimental results show that the differences of combustion velocity among different wastes in Fluidized Bed(FB) were very small whereas in thermogravimetric analyzer the differences can not be ignored as the value range of combustion velocity variation was between 0.49 and 5.5. It took municipal solid waste 3-3.5 min to burn out in FB, but in thermogravimetric analyzer, the time was 20-25 min. It can be concluded that, in general, the behavior of a mixture of waste in TGA can be expressed by simple combination of individual components of the waste mixtures. Only minor deviations from the rule were observed. In FB, it was found that, for some mixtures, there was interference among the components during FB combustion.

Hot Temperature↗

Toxic chlorinated and polyaromatic hydrocarbons in simulated house fires.

Toxic chlorinated hydrocarbons (polychlorinated biphenyls, benzenes and dioxins and furans) and polyaromatic hydrocarbons were examined in combustion gas and deposited soot wipe samples from simulated house fires. Concentrations of these substances were high during the fires, the amounts of polychlorinated dioxins and furans (PCDD/Fs) in the combustion gas varying from 1.0 to >7.2 ng/m3 (I-TEQ) and those of polyaromatic hydrocarbons from 6.4 to 470 mg/m3. Thus large amounts of organic compounds may be released in house fires. As a result, there is a need for careful personal protection of fire-fighters and remediation workers against combustion gases during a fire and on contaminated surfaces after it.

Air Pollutants↗

The dynamics of flash fires involving flammable hydrocarbon liquids.

Victims of fires are sometimes discovered to have less-than-lethal levels of carbon monoxide (CO) in the blood and no significant antemortem fire damage. Such occurrences are often linked to flash fires involving volatile hydrocarbon fuels. In this study, the dynamics of hydrocarbon fuel fires are examined, and the results of fullscale room tests ignited with small (< 2 L) quantities of flammable liquid are found to confirm the theoretical predictions. These tests showed that flame plumes with temperatures of 500-975 degrees C were produced above flammable liquids. Ignition of their vapors in a carpeted room produced a very short-lived flash of fire throughout the room, followed by intense flames in a layer above the floor approximately 1 m deep, which quickly degenerated to isolated pools of low flames. Combustion of hydrocarbon vapors in a room caused oxygen levels to drop below 8.5% in < 100 s, while causing carbon dioxide (CO2) levels to increase to 12-16% whether the door to the room was open or closed. Production of CO trailed maximum CO2 production by 15-30 s. A victim exposed to such a fire may collapse from extreme heat (aided by the water vapor created by the combustion of hydrocarbons), weakened by oxygen deprivation, before CO inhalation becomes a significant factor.

Carbon Dioxide↗

[Lead emission amount from coal combustion and its environment effect in Xi'an City].

For study the lead emission amount from coal combustion and its environment effect, the lead content of coal, ash and cinder of power station and coal-fired boiler, the lead content of dusts in the period of heating time and the non-heating time in Xi'an City were studied in this paper. The results show that amount of lead emission from 1 ton coal combustion, which lead content in coal was 30 g, was 20 g in atmosphere. The rate of lead emission of coal combustion was about 66%. About 10 million tons of coal was straight burning every year in Xi'an City and suburb, those coal mainly come from Permo-Carboniferous coal in Weibei coal mine, Shaanxi, their average lead content was 30 mg/kg. So the total lead emission from coal combustion to atmosphere was about 200 t annually in Xi'an City.

Air Pollutants↗

Explosion and fire in the expiratory limb of a Fisher and Paykel "three in one" respiratory care system.

We report an incident involving a Fisher and Paykel "There in One Respiratory Care System" (Fisher and Paykel Healthcare, Auckland, New Zealand). This is a new ventilator circuit designed to be adaptable to the needs of ventilator, intubated CPAP, and mask therapies. In this case the patient had received eight hours of CPAP therapy overnight, during which time the "Three in One" circuit had been broken down to the CPAP configuration. The expiratory limb heater element, normally disconnected, was inadvertently left connected to the heater base. Under the extreme conditions of heating under "no gas flow" mode, the heater element malfunctioned. As a result when the circuit was reconfigured to provide pressure-supported ventilation, in the high oxygen environment of the expiratory limb (FiO2 0.5), ignition and combustion of the respiratory circuit occurred. The case is reported because of the potentially serious consequences and because the incident prompted the manufacturer to redesign and change componentry in parts of the circuit implicated.

Aged↗