Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPECTROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Analysis of methionine enkephalin in human pituitary by multi-dimensional reversed-phase high-performance liquid chromatography, radioreceptor assay, radioimmunoassay, fast atom bombardment mass spectrometry, and mass spectrometry-mass spectrometry.

Methionine enkephalin (ME = YGGFM) was measured in five individual human post-mortem pituitaries using four different analytical methods, with the objective of comparing the molecular specificities of the methods. Radioreceptor assay (RRA) used a receptor-rich preparation from brain and [3H]etorphine as radioligand to determine ME-like receptoractivity (ME-LR). Radioimmunoassay (RIA) measured ME-like immunoreactivity (ME-LI). Pituitary samples analyzed by RRA and RIA were purified first with a high-performance liquid chromatography (HPLC) gradient on a polymer analytical column. Fast atom bombardment mass spectrometry (FAB-MS) in two different detection modes quantified ME using the protonated molecular ion MH+ of ME at 574 a.m.u. and B/E linked-field selected reaction monitoring (SRM) to monitor the specific unimolecular metastable transition that produced the unique amino acid sequence-determining tetrapeptide fragment ion YGGFA+ from the MH+ precursor ion. Both FAB-MS methods used the deuterated internal standard YGG[2H5-F]M. Samples analyzed with FAB-MS were purified first with multi-dimensional reversed-phase HPLC. The first dimension was an ODS gradient, and the second dimension was a polymer isocratic elution. The following ME amounts were measured (mean +/- standard error of the mean): ME-LR, 7.0 +/- 1.9 micrograms g-1 tissue; ME-LI, 1.8 +/- 0.7 micrograms g-1 tissue; MH+, 2.7 +/- 0.6 micrograms g-1 tissue; SRM, 3.0 +/- 0.8 micrograms g-1 tissue. The FAB SRM method provided the highest level of molecular specificity amount these four analytical methods used to measure picomole amounts of endogenous ME in a human pituitary.

Adult↗

Stability of fluorinated surfactants in advanced oxidation processes--A follow up of degradation products using flow injection-mass spectrometry, liquid chromatography-mass spectrometry and liquid chromatography-multiple stage mass spectrometry.

The advanced oxidation process (AOP) reagents ozone (O3), O3/UV, O3/H2O2, and H2O2/Fe2+ (Fenton's reagent) were applied to the anionic and the non-ionic fluorinated surfactants perfluorooctanesulfonate (PFOS) and N-ethyl-N-(perfluoroalkyl)-sulfonyl-glycinic acid (HFOSA-glycinic acid) or N-ethyl-N-perfluoroalkyl sulfonylamido-2-ethanol polyethoxylates (NEtFASE-PEG), their methyl ethers (NEtFASE-PEG methyl ether) and partly fluorinated alkyl-ethoxylates (FAEO) dissolved in ultrapure water. To monitor the efficiencies of destruction samples were taken during the treatment period of 120 min. After sample concentration by C18-solid phase extraction (SPE) and desorption MS, coupled with atmospheric pressure chemical ionisation (APCI) or electrospray interface (ESI) was applied for detection. No elimination of PFOS was observed while HFOSA-glycinic acid and AOP treated non-ionic surfactants were eliminated by oxidation. Degradation products could be detected and identified. So PFOS was observed during HFOSA-glycinic acid oxidation. Polyethylene glycols (PEG) and PEG methyl ethers were generated from non-ionic fluorinated surfactants beside their oxidation products--aldehydes and acids--all identified by tandem (MS-MS) or multiple stage mass spectrometry (MSn). AOP treatment of FAEO blend resulted in a mixture of partly fluorinated alcohols, separated and identified using GC-MS.

Biodegradation, Environmental↗

Mass spectrometry in the study of anthocyanins and their derivatives: differentiation of Vitis vinifera and hybrid grapes by liquid chromatography/electrospray ionization mass spectrometry and tandem mass spectrometry.

A mass spectrometric-based procedure for anthocyanin profiling was set up to distinguish authentic Vitis vinifera from hybrid red grapevine cultivars. 3-O-Monoglucoside and the related acetyl-, p-coumaryl- and caffeoyl-monoglucoside anthocyanins occurred only in Vitis vinifera, whereas 3,5-O-diglucoside and the substituted acetyl-, p-coumaryl-, feruloyl- and caffeoyl-diglucoside anthocyanins were the additional pigments in hybrid grapevines. The procedure was applied expressly to identify red grape cultivars based on the anthocyanin chemo-type determination. In particular, a red grape cultivar, having 3,5-O-diglucoside anthocyanins and a novel class of anthocyanin monoglucosides, such as cyanidin-3-O-, cyanidin-3-O-(6-O-acetyl)- and cyanidin-3-O-(6-O-p-coumaryl)pentoside, was classified as hybrid. A second vine cultivar, characterized exclusively by 3-O-monoglucoside anthocyanins, was included among the Vitis vinifera species. Anthocyanin profiling by mass spectrometry could represent the core of a chemotaxonomic procedure for distinguishing American and European grapevines based on the identification of post-synthetic anthocyanidin modification.

Anthocyanins↗

Tracing of surfactants in the biological wastewater treatment process and the identification of their metabolites by flow injection-mass spectrometry and liquid chromatography-mass spectrometry and -tandem mass spectrometry.

Results of aerobic biodegradation of alkyl ethoxylates (AEOs), of nonylphenol polyethoxylates (NPEOs), and of NPEO derivatives (sulfonates and sulfates), as well as anaerobic NPEO biodegradation monitored by flow injection analysis (FIA) or liquid chromatographic separation (LC) in combination with mass (MS) and tandem mass spectrometry (MS-MS) are presented. The application of visual pattern recognition in the FIA-MS mode showed quite different degradation pathways for C13-AEOs, so that aldehyde compounds as metabolites could be confirmed by collision-induced dissociation for the first time. Methyl ethers of AEO compounds were found to be persistent under aerobic conditions, while NPEO degradation resulted in nonylphenol polyether carboxylates. FIA- and LC-MS proved that NPEO derivatives used as anionic surfactants were either non-biodegradable (nonylphenol diethoxy sulfonate) or were primarily degraded (nonylphenol polyethoxy sulfates) into compounds of the same molar masses yet of different retention behaviour. Anaerobic degradation of NPEOs led to the generation of nonylphenols, which was confirmed by GC-MS.

Biodegradation, Environmental↗

Analytical techniques in biomedical stable isotope applications: (isotope ratio) mass spectrometry or infrared spectrometry?

An overview is presented of biomedical applications of stable isotopes in general, but mainly focused on the activities of the Center for Liver, Digestive and Metabolic Diseases of the University Medical Center Groningen. The aims of metabolic studies in the areas of glucose, fat, cholesterol and protein metabolism are briefly explained, as well as the principle of breath testing and the techniques to study body composition and energy expenditure. Much attention is paid to the analytical considerations based upon metabolite concentrations, sample size restrictions, the availability of stable isotope labelled substrates and dose requirements in relation to compound-specific isotope analysis. The instrumental advantages and limitations of the generally used techniques gas chromatography/reaction/isotope ratio mass spectrometry and gas chromatography/mass spectrometry are described as well as the novelties of the recently commercialised liquid chromatography/combustion/isotope ratio mass spectrometry. The present use and future perspective of infrared (IR) spectrometry for clinical and biomedical stable isotope applications are reviewed. In this respect, the analytical demands on IR spectrometry are discussed to enable replacement of isotope ratio mass spectrometry by IR spectrometry, in particular, for the purpose of compound-specific isotope ratio analysis in biological matrices.

Amino Acids↗

Fast atom bombardment mass spectrometry and tandem mass spectrometry in antibiotics: identification of nucleoside antitumor antibiotic toyocamycin in fermentation broth.

The presence of the nucleoside antitumor antibiotic toyocamycin in the fermentation broth was determined by a combination of negative and positive ion fast atom bombardment (FAB) mass spectrometry, high resolution FAB mass spectrometry and mass-analysed ion kinetic energy spectrometry (MIKES). A reasonable limit of detection for toyocamycin in the whole broth was obtained by combining the specificity of mass spectrometry/mass spectrometry (also called tandem mass spectrometry) to FAB. The role played by the fermentation matrix upon the production and the observation of characteristic ions by FAB using xenon atoms was examined. High-performance liquid chromatography (HPLC) and FAB mass spectrometry were used to monitor toyocamycin at all stages of strain development, fermentation and recovery.

Antibiotics, Antineoplastic↗

(13)CO(2) breath tests: comparison of isotope ratio mass spectrometry and non-dispersive infrared spectrometry results.

BACKGROUND AND AIMS: Isotope ratio mass spectrometry is the standard analytical method for (13)CO(2) breath tests. The goal of this study was to compare the results of (13)CO(2) breath tests obtained by non dispersive infrared spectrometry, a new, simpler and cheaper method, with those obtained by the gold standard method. METHODS: Three hundred and eight patients were included: 150 underwent a urea breath test for Helicobacter pylori diagnosis, 140 an aminopyrine breath test to measure liver function, and 18 an octanoic acid breath test for gastric emptying evaluation. A total of 750 breath samples were obtained in duplicate for isotope ratio mass and infrared spectrometry analyses. Breath test results were compared using Bland-Altman plots. RESULTS: The agreement between the two methods was excellent for urea breath tests (kappa coefficient=0.96), with only 3 discordant results. Although (13)C isotopic enrichment in breath was significantly lower with infrared spectrometry (P<0.0001), the agreement for the results of aminopyrine and octanoic acid breath tests was excellent. The clinical significance of these tests was similar for both methods. CONCLUSIONS: Infrared spectrometry results are comparable to isotope ratio mass spectrometry. Because this analytical method is simpler and less expensive, it could be used for clinical applications of (13)CO(2) breath tests.

Adolescent↗

Mass spectrometry and tandem mass spectrometry of citrus limonoids.

Methods for atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) of citrus limonoid aglycones and electrospray ionization tandem mass spectrometry (ESI-MS/MS) of limonoid glucosides are reported. The fragmentation patterns of four citrus limonoid aglycones (limonin, nomilin, obacunone, and deacetylnomilin) and six limonoid glucosides, that is, limonin 17-beta-D-glucopyranoside (LG), nomilin 17-beta-D-glucopyranoside (NG), nomilinic acid 17-beta-D-glucopyranoside (NAG), deacetyl nomilinic acid 17-beta-D-glucopyranoside (DNAG), obacunone 17-beta-D-glucopyranoside (OG), and obacunoic acid 17-beta-D-glucopyranoside (OAG) were investigated using a quadruple mass spectrometer in low-energy collisionally activated dissociation (CAD). The four limonoid aglycones and four limonoid glucosides (LG, OG, NAG, and DNAG) were purified from citrus seeds; the other two limonoid glucosides (NG and OAG) were tentatively identified in the crude extract of grapefruit seeds by ESI mass spectrometry in both positive and negative ion analysis. Ammonium hydroxide or acetic acid was added to the mobile phase to facilitate ionization. During positive ion APCI analysis of limonoid aglycones, protonated molecular ion, [M + H]+, or adduct ion, [M + NH3 + H]-, was formed as base peaks when ammonium hydroxide was added to the mobile phase. Molecular anions or adduct ions with acetic acid ([M + HOAc - H] and [M + HOAc]-) or a deprotonated molecular ion were produced during negative ion APCI analysis of limonoid aglycones, depending on the mobile-phase modifier used. Positive ion ESI-MS of limonoid glucosides produced adduct ions of [M + H + NH3]+, [M + Na]+, and [M + K]+ when ammonium hydroxide was added to the mobile phase. After collisionally activated dissociation (CAD) of the limonoid aglycone molecular ions in negative ion APCI analysis, fragment ions indicated structural information of the precursor ions, showing the presence of methyl, carboxyl, and oxygenated ring structure. CAD of the adduct ion [M + H + NH3]+ of limonoid glucosides produced the aglycone moiety corresponding to each glucoside. The combination of mass spectrometry and tandem mass spectrometry provides a powerful technique for identification and characterization of citrus limonoids.

Benzoxepins↗

Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

Cortisol is an important diagnostic marker for the production of steroid hormones, and accurate measurements of serum cortisol are necessary for proper diagnosis of adrenal function. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(3), was added to serum, followed by equilibration and solid-phase and ethyl acetate extractions to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) and liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analyses. (M + H)(+) ions at m/z 363 and 366 for cortisol and its labeled internal standard were monitored for LC/MS. The transitions of (M + H)(+) --> [(M + H)(+) - 2H(2)O] at m/z 363 --> 327 and 366 --> 330 were monitored for LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for cortisol [Certified Reference Materials 192 and 193] with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added cortisol. The results of this method for total cortisol agreed with the certified values within 1.1%. The recovery of the added cortisol ranged from 99.8% to 101.0%. This method was applied to the determination of cortisol in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.3%-1.5% and between-set CVs of 0.04%-0.4% for both LC/MS and LC/MS/MS analyses. The correlation coefficients of all linear regression lines ranged from 0.998 to 1.000. The detection limits (at a signal-to-noise ratio of approximately 3-5) were 10 and 15 pg for LC/MS and LC/MS/MS, respectively. This method, which demonstrates good accuracy and precision, and is free from interferences from structural analogues, qualifies as a candidate reference method and can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared.

Chromatography, Liquid↗

Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system.

Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.

Caffeine↗

Identification of catechin oligomers from apple (Malus pumila cv. Fuji) in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and fast-atom bombardment mass spectrometry.

Molecular size information for polymerized catechin larger than the decamer in unripe apple was obtained by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and by fast-atom bombardment mass spectrometry. Matrix-assisted laser desorption/ionization time of flight mass spectrometry provided evidence for the pentadecamer using trans-3-indoleacrylic acid as the matrix in the presence of silver ion. Even in the absence of silver ion, the dodecamer and undecamer were observed in the positive- and negative-ion modes, respectively. Fast-atom bombardment mass spectrometry also afforded evidence for the undecamer in both positive- and negative-ion modes.

Catechin↗

Structural characterization of the cyanelle peptidoglycan of Cyanophora paradoxa by 252Cf plasma desorption mass spectrometry and fast atom bombardment/tandem mass spectrometry.

A strategy for the structural characterization of the four major NaBH4-reduced peptidoglycan monomers derived from muramidase-digested peptidoglycan from the cyanelles of the flagellate Cyanophora paradoxa Korschikoff is described. Initial molecular weight determination of these glycopeptides was performed by positive and negative ion plasma desorption mass spectrometry. Due to the presence of two pairs of disaccharide tripeptide and disaccharide tetrapeptide monomers differing in mass by 112 units, respectively, an as yet unknown peptidoglycan modification either at the carbohydrate or at the peptide moiety was assumed. beta-Elimination of the disaccharide unit from the unreduced peptidoglycan monomers yielded the corresponding (modified) N1-lactyltripeptides and -tetrapeptides, respectively. These peptides, N-terminally blocked with lactic acid, unambiguously showed the modification to be located on the peptide moiety. By positive ion fast atom bombardment/hybrid tandem mass spectrometry of the reduced peptidoglycan monomers as well as of the corresponding deglycosylated monomers (= N1-lactylpeptides) the modification was determined to be linked to the glutamic acid moiety. Based on combined data from plasma desorption mass spectrometry, tandem mass spectrometry, accurate mass measurement and amino acid analysis of the acid hydrolysate after derivatization with o-phthaldialdehyde by high-performance liquid chromatography we could establish the structure of the modification as N-acetylputrescine. Finally, the confirmation of the linkage of the glutamic acid to diaminopimelic acid via the gamma-COOH was based on the presence of a-type peptide backbone fragment ions in the positive ion plasma desorption mass spectra of the modified N1-lactylpeptides.

Amino Acid Sequence↗

RNA-RNA noncovalent interactions investigated by microspray ionization mass spectrometry.

Electrospray ionization mass spectrometry is playing an increasing role in the study of noncovalent interactions involving biomolecules. RNA-RNA complexes are important in many areas of biology, including RNA catalysis, RNA splicing, ribosome function, and gene regulation. Here, microelectrospray mass spectrometry (microESI-MS) is used to study noncovalent base-pairing interactions between RNA oligonucleotides, an area not previously explored by this technique. Using a set of complementary RNA oligonucleotides, we demonstrate the formation of the expected double-helical RNA complexes composed of three distinct oligonucleotides. The ability to study specific RNA noncovalent interactions by microESI-MS has the potential to provide a unique method by which to analyze and assign precise molecular masses to RNA-RNA complexes.

Base Sequence↗

Characterization of O-glycosylation sites in recombinant B-chain of platelet-derived growth factor expressed in yeast using liquid secondary ion mass spectrometry, tandem mass spectrometry and Edman sequence analysis.

High-performance tandem mass spectrometry has been employed to structurally characterize intact O-linked glycopeptides and establish the complexity and extent of glycosylation for recombinant human platelet-derived growth factor B chain (rhPDGF-B) expressed in yeast. In addition, liquid secondary ion mass spectrometry (LSIMS) and Edman degradation have been employed to verify the protein sequence. LSIMS of high-performance liquid chromatographically fractionated proteolytic digests confirmed the complete amino acid sequence predicted by the human PDGF-B gene structure. Potential glycopeptides (as indicated by a mass shift of 162 or 324 Da from the mass of a predicted cleavage product) were sequenced using tandem mass spectrometry and Edman degradation. Ultraviolet matrix laser desorption mass spectrometry of rhPDGF-B dimer was used to determine the molecular weight distribution for the intact recombinant glycoprotein. In addition to the presence of unmodified peptides, corresponding peptides bearing monomannosyl moieties were found on serine 26 and threonines 20, 63, 88, 90 and 101. Further, dimannosyl moieties were found on threonines 6 and 63. These data reveal the presence of O-linked glycosylation at sites which do not fortify the concept of a consensus sequence involving proline residues, but which strengthen the concept of secondary and tertiary structure requirements. The advantages of high-energy collisionally induced dissociation analysis of O-linked glycopeptides over conventional base elimination and borohydride reduction and other mass spectrometric techniques are presented for the first time.

Amino Acid Sequence↗

Utility of liquid chromatography/fast atom bombardment mass spectrometry and liquid chromatography/thermospray mass spectrometry for structure identification of metabolites of a fluorinated herbicide.

This study demonstrates a useful application of on-line microbore high-performance liquid chromatography (HPLC) fast atom bombardment (FAB) and thermospray (TSP) mass spectrometry techniques for identification of metabolites from the in vitro metabolism of an experimental Monsanto herbicide: 2-chloro-N-(ethoxymethyl-N-[2-methyl-6- (trifluoromethyl)phenyl]acetamide, 'chloroacetanilide'. The microbore HPLC FAB technique on a high-resolution sector mass spectrometer accelerated identification of polar metabolites from the in vitro metabolism study of the herbicide. It provided good chromatographic resolution and excellent FAB sensitivity with strong protonated molecular ions. Scanning high-resolution LC/FAB mass spectrometry also provided molecular formulae for structural elucidation of unknown metabolites. Sample purification and concentration were minimized. Identification of less polar metabolites was carried out using LC/TSP mass spectrometry with a quadrupole mass spectrometer. LC/TSP mass spectrometry provided useful structural information for both polar and less polar metabolites because their spectra showed more fragmentation than FAB spectra. Glutathione conjugation was the major reaction observed during in vitro incubation of the herbicide. Oxidation of the chloroacetanilide by rat liver enzymes was also a significant metabolic reaction. Seven metabolites were identified, of which four were glutathione conjugates.

Acetamides↗

Characterization of the primary structure of H-protein from Pisum sativum and location of a lipoic acid residue by combined liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.

A purified extract of H-protein, a subunit of the glycine cleavage complex of the pea leaf mitochondria, was investigated by liquid chromatography/mass spectrometry (LC/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS), using both continuous flow fast atom bombardment (CF-FAB) and electrospray ionization (ESI) mass spectrometry. Determination of the molecular weight of the entire protein, a 14 kDa subunit of the glycine decarboxylase complex, was achieved by ESI mass spectrometry and revealed covalent binding of the protein to the stabilizing agent beta-mercapto-ethanol. On-line LC/MS analysis of peptides arising from the endoproteinase Glu-C digestion of the H-protein was achieved using capillary columns (0.25 mm i.d.), and permitted confirmation of the previously reported sequence deduced from cDNA cloning experiments. The detailed interpretation of data extracted from these LC/MS experiments facilitated identification of peptides containing modified amino acid residues. In particular the identification of a lipoic acid cofactor, a rather unusual modified lysine residue which interacts with different active sites in the enzyme complex, was achieved using both LC/CF-FAB-MS and LC/ESI-MS. The exact location of this modified lysine residue was determined by obtaining fragment spectra of multiply protonated precursor ions of selected peptides, using on-line LC/MS/MS techniques.

Amino Acid Oxidoreductases↗

Characterization of a synthetic 37-residue fragment of a monoclonal antibody against herpes virus by capillary electrophoresis/electrospray (ionspray) mass spectrometry and 252Cf plasma desorption mass spectrometry.

A peptide comprising 37 amino acids of the antigen binding site of a monoclonal antibody directed against glycoprotein D of herpes simplex virus was synthesized. The synthetic peptide and the impurities formed in the synthesis were characterized by capillary electrophoresis/ionspray mass spectrometry and by 252Cf plasma desorption-time of flight mass spectrometry. The measured average molecular mass of the synthetic peptide was 4627.16 Da, which was only 0.08 Da higher than the calculated value (4627.08 Da). The plasma desorption mass spectrum of the synthetic peptide showed a protonated molecule at m/z 4624.1, which was 4 Da lower than the calculated one (4628.09 Da). The amino acid sequence of the peptide was confirmed in part by electrospray (ionspray) mass spectrometry using a high nozzle skimmer voltage difference. Five impurities were separated and identified by capillary electrophoresis/mass spectrometry and two of them also appeared in the plasma desorption mass spectrum.

Amino Acid Sequence↗