Search PubMedSearch

SEARCH · Search PubMed

Results for “Radiotherapy Planning, Computer-Assisted”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

346 records · Page 2Linked to original sources

Hip Arthroscopy-Assisted Management of Pipkin Types I and II Femoral Head Fracture-Dislocations: Mid-Term Clinical and Radiographic Outcomes.

OBJECTIVES: Hip arthroscopy-assisted surgery has been proposed as a minimally invasive option for femoral head fractures; however, evidence with mid-term follow-up remains limited. This study aimed to evaluate the clinical and radiographic outcomes of arthroscopy-assisted management for Pipkin Types I and II femoral head fracture-dislocations with a minimum follow-up of 5 years. METHODS: This retrospective study included 23 consecutive adults (19 Pipkin I and 4 Pipkin II) treated with hip arthroscopy-assisted fragment excision or internal fixation between March 2013 and January 2020. Preoperative computed tomography was used for surgical planning, and fixation was placed with arthroscopic headless screws. Clinical outcomes were assessed using the Harris Hip Score (HHS) and Thompson-Epstein (T-E) criteria. Radiographic evaluation included avascular necrosis (AVN), heterotopic ossification (HO; Brooker), osteoarthritis (OA; Tönnis), and fracture reduction quality (Matta's criteria). Group comparisons were evaluated using independent samples t-tests, Mann-Whitney U tests, and Fisher's exact test. The mean follow-up was 86.2 ± 21.2 months. RESULTS: The cohort consisted of 19 males and 4 females with a mean age of 28.7 ± 9.9 years. Fifteen patients underwent fixation and eight underwent excision. The final mean HHS was 98.3 ± 1.9, with 21 patients (91%) achieving excellent and 2 (9%) good T-E criteria. There were no significant differences between the fixation and excision groups in demographic characteristics, operative time, or functional outcomes (all p > 0.05); however, hospital stay was significantly shorter in the excision group (2.9 ± 0.6 vs. 5.5 ± 4.6 days, p = 0.028). In the fixation group, mean maximal displacement improved from 7.6 mm preoperatively to 2.6 mm postoperatively, with anatomic reduction achieved in 6 cases (40%), imperfect in 6 (40%), and poor in 3 (20%). Patients with Pipkin Type I fractures had significantly higher HHS than those with Type II fractures (98.7 ± 1.7 vs. 96.0 ± 0.8, p = 0.018). Complications were rare, with one case of Brooker Grade I HO and one case of mild OA. No AVN or total hip arthroplasty occurred during the follow-up. CONCLUSIONS: Hip arthroscopy-assisted management of selected Pipkin Type I and II femoral head fractures yields excellent mid-term clinical outcomes with acceptable radiographic reduction and a low complication rate. This minimally invasive technique represents a viable alternative in appropriately selected patients when fragment characteristics and surgical expertise permit.

Humans

Incidence of retropharyngeal lymph node involvement in oropharyngeal squamous cell carcinoma: a systematic review and meta-analysis.

BACKGROUND: Retropharyngeal lymph node (RPN) involvement in oropharyngeal squamous cell carcinoma (OPSCC) may influence prognosis, staging, radiotherapy target volumes, and treatment strategy. However, its true prevalence and association with clinicopathological factors remain incompletely defined. METHODS: A systematic review and meta-analysis was performed in accordance with the PRISMA 2020 statement. MEDLINE, EMBASE, EMCARE, PubMed, Web of Science, Scopus, and the Cochrane Library were searched from database inception to 15 June 2026. Studies reporting radiological or pathological assessment of retropharyngeal lymph node (RPN) involvement in oropharyngeal squamous cell carcinoma (OPSCC) were included. Pooled prevalence estimates were calculated using a random-effects model, with subgroup analyses according to tumour stage, nodal status, HPV status, and primary tumour subsite. RESULTS: Fourteen studies comprising 8,887 patients were included. The pooled prevalence of RPN involvement was (95% CI 11-16%; 95% PI 6-24%), with substantial heterogeneity. HPV-negative tumours demonstrated higher prevalence than HPV-positive tumours (21% vs 11%). Prevalence increased with advancing T stage, from 2% in T1 to 18% in T4 disease, and was higher in node-positive than node-negative disease (16% vs 1%). Tonsillar primaries showed higher prevalence than base of tongue tumours (14% vs 8%). Among patients with RPN involvement, the pooled distant metastasis rate was 16%. CONCLUSION: RPN metastases were identified in approximately one in eight patients with OPSCC and were more frequent in HPV-negative disease, advanced stage, and tonsillar primaries. These findings support careful evaluation of the retropharyngeal space during staging and may assist risk stratification in selected higher-risk patients.

Humans

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30·9% (114 of 369 patients) with HD-WL versus 33·8% (123 of 364 patients) with CADe assistance (odds ratio 1·14 [95% CI 0·83-1·57], p=0·41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85·9% (95% CI 82·0-89·1) and specificity was 91·4% (89·4-93·0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans

An automated geometric modeling framework in GATE for the design and optimization of high-sensitivity converging-beam SPECT collimators.

Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.

Tomography, Emission-Computed, Single-Photon

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Reliability-aware hierarchical learning for Chagas disease screening from 12-lead ECGs: tackling label uncertainty and class imbalance.

Objective.Chagas disease, a neglected tropical disease (NTD) with significant cardiovascular impact, remains underdiagnosed in resource-limited regions. Electrocardiogram (ECG) screening offers a low-cost tool for detecting cardiac involvement, yet algorithm development is challenged by label noise, data scarcity, and the latent nature of infection. This study proposes a robust ECG-based screening framework that explicitly addresses these constraints.Approach.We introduce aReliability-Aware Hierarchical Learningstrategy that calibrates supervision according to data provenance, prioritizing serology-confirmed labels over noisy self-reports. To mitigate data scarcity, we compare a specialized convolutional neural network (CNN) trained from scratch with a transfer learning approach based on a Spatio-Temporal ECG foundation Model (FM). Performance is evaluated across varying data scales, and the representation structure is analyzed to interpret model behavior.Main results.On the official hidden test set of the George B. Moody PhysioNet/Computing in Cardiology Challenge 2025, our approach achieved a Challenge Score of 0.163. We observe that while the specialized CNN performs competitively in data-rich regimes, the FM exhibits superior robustness in extreme low-resource settings. Furthermore, performance reaches a plateau imposed by underlying disease physiology. Bimodal score distributions suggest that models distinguish established cardiomyopathy from indeterminate infection, which remains electrophysiologically indistinguishable from healthy controls.Significance.These findings clarify both the potential and intrinsic limits of ECG-based AI screening for NTD-associated cardiac involvement. Reliability-aware supervision and data-efficient transfer learning provide a practical framework toward scalable and clinically meaningful ECG screening systems in resource-constrained environments.

Humans

Evaluation of the difference between automated and measured QTc intervals in children.

BACKGROUND: The corrected QT interval (QTc) is obtained through automated ECG computations or manual physician measurements. We hypothesized that differences exist in children between the measured and automated QTc intervals within and between Healthy and hypertrophic cardiomyopathy (HCM) subjects with greater differences for HCM due to structural abnormalities. METHODS: QT measurements - Bazett correction- automated (aQTc) and measured (mQTc), were extracted from the GE MUSE database for 385 Healthy pediatric (single ECG) and 208 HCM subjects (2 ECGs), stratified by age&#xa0;<&#xa0;12 and&#xa0;&#x2265;&#xa0;12&#xa0;yrs., sex, race, and ethnicity. QTc means (SD), automated and measured differences, and the difference of the differences of aQTc and mQTc were analyzed overall and by subgroups. All ECGs were read by one pediatric cardiologist with a second cardiologist reading a random subset of HCM ECGs to evaluate intraclass correlations and agreement. RESULTS: The mQTc intervals were shorter than aQTc intervals within Healthy (p&#xa0;<&#xa0;0.001) and within first HCM ECGs (p&#xa0;<&#xa0;0.001) with both aQTc and mQTc shorter in Healthy than HCM (p&#xa0;<&#xa0;0.001). The difference in these differences was significant overall using HCM ECG 1 but not HCM ECG 2. Healthy subject aQTc and mQTc intervals differed by age, sex, and race (p&#xa0;<&#xa0;0.002). HCM ECG 1 aQTc- mQTc intervals differed for age&#xa0;<&#xa0;12&#xa0;yrs., as well as by sex and race. HCM ECG 2 intervals differed only for age&#xa0;<&#xa0;12&#xa0;yrs. CONCLUSIONS: Compared to measured values, automated QTc values were significantly longer in both Healthy and HCM subjects. Automated measurements may overestimate the QTc.

Humans

Meta-Analysis of the Efficacy of Ultrasound-Guided Mammotome Minimally Invasive Surgery and Traditional Open Surgery in the Therapy of Benign Breast Tumors.

ObjectiveTo systematically analyze the efficacy of ultrasound-guided mammotome minimally invasive surgery and traditional open surgery in the therapy of benign breast tumors.MethodsA computerized search retrieved original literature on the therapeutic effects of ultrasound-guided mammotome minimally invasive surgery and traditional open surgery for benign breast tumors from authoritative databases, including CNKI, Wanfang, VIP, Web of Science, PubMed, ScienceDirect, Cochrane Library, and Embase. The search covered from database inception to January 2024, using a strategy of subject terms combined with free terms. The retrieved literature was screened, data were extracted, and quality was evaluated. Meta-analysis was performed using RevMan 5.4 software.ResultsA total of 8 literatures were included in the study, and a total of 1909 patients with benign breast tumors were found from 2018 to 2023. The results of meta-analysis showed that the operation time [MD = -12.79, 95%CI (-14.04, -11.55), P < 0.00001], intraoperative blood loss [MD = -11.55, 95%CI (-14.74, -8.36), P < 0.00001], healing time [MD = -2.73, 95%CI (-4.03, -1.43), P < 0.00001] and complication rate [MD = 0.17, 95%CI (0.12, 0.26), P < 0.00001] was apparently different from traditional open surgery (P < 0.05).ConclusionUltrasound-guided mammotome minimally invasive surgery can effectively shorten the operation time of patients with benign breast tumors, reduce intraoperative blood loss, promote healing, and reduce the risk of complications. The effect is better than that of traditional open surgery.

Humans

Fundamentals of pacemakers ECG interpretation - part 2.

BACKGROUND: Modern pacemakers incorporate arrhythmia-response algorithms, ventricular pacing minimization protocols, and safety mechanisms that generate ECG patterns indistinguishable from pathological AV block, sensing malfunction, or device-mediated tachycardia. Failure to recognize these algorithm-driven signatures leads to unnecessary interventions, misdiagnosis, and inappropriate device reprogramming. This manuscript is the second in a two-part series on pacemaker ECG interpretation. METHODS: We conducted a narrative review of peer-reviewed literature and device-specific documentation on algorithm-driven ECG behavior, synthesizing evidence across arrhythmia recognition, upper rate physiology, ventricular pacing minimization, mode switching, safety mechanisms, and hysteresis algorithms. RESULTS: Pacemaker-mediated tachycardia produces regular paced wide-complex tachycardia locked at the upper tracking rate, initiated by any event with retrograde VA conduction. Ventricular tachycardia is identified by QRS morphology diverging from the known paced pattern, absent pacing spikes, and AV dissociation. Upper rate Wenckebach behavior mimics Mobitz type I AV block; 2:1 upper rate response mimics second-degree AV block. Ventricular pacing minimization algorithms produce isolated nonconducted P waves and prolonged AV intervals that simulate pathological conduction disease. Mode switching causes abrupt rate drops misidentified as output failure. Ventricular safety pacing generates a conspicuously short, fixed AV interval. Three discrete pacing artifacts reflect AV-sequential cardiac resynchronization therapy (CRT), ventricular safety pacing in CRT, or His-bundle pacing with backup RV output. Rate and AV hysteresis produce pauses and wandering AV intervals mimicking oversensing or Wenckebach periodicity. CONCLUSIONS: Recognizing algorithm-driven ECG patterns requires knowledge of device timing intervals and refractory periods, which lets clinicians distinguish programmed behavior from true malfunction or cardiac arrhythmia.

Humans

RR-interval-based atrial fibrillation detection and burden estimation: cross-dataset validation and calibration-aware probability analysis.

Objective.Atrial fibrillation (AF) burden has become an increasingly important endpoint in long-duration rhythm monitoring, but reliable burden estimation requires more than accurate AF detection alone. In particular, when burden is derived by aggregating predicted AF probabilities over time, probability calibration may directly affect burden validity under external dataset shift.Approach.This study developed an interpretable-interval feature model for AF detection and evaluated it using record-wise cross-validation on a development cohort and independent cross-dataset external validation on public Holter electrocardiographic databases. Window-level performance was assessed using the area under the receiver operating characteristic curve (ROC-AUC), area under the precision-recall curve (PR-AUC), Brier score, expected calibration error (ECE), and calibration intercept and calibration slope. Recording-level AF burden was estimated using both probability-based and hard-label aggregation and evaluated using mean absolute error (MAE) and agreement analyses.Main results.The model showed high discrimination in both development and external evaluation, with external ROC-AUC ofand PR-AUC of. However, external calibration deteriorated despite preserved ranking performance, with Brier score of, ECE(15) of, calibration intercept of, and calibration slope of. In the external cohort, probability-based burden estimation preserved strong association with reference burden but showed weaker raw agreement than hard-label aggregation, with MAE ofversus, consistent with systematic probability underprediction. Repeated external recalibration across record-level splits substantially improved probability quality and probability-based burden estimation. Median probability-burden MAE decreased fromwithout recalibration toafter Platt recalibration andafter isotonic recalibration, while median ECE(15) decreased fromtoand, respectively.Significance.These findings indicate that-interval-based AF detection maintained strong ranking performance in the tested external cohort, but probability calibration should be evaluated explicitly when predicted probabilities are aggregated into AF-burden estimates.

Atrial Fibrillation

Post-intervention effectiveness of a computerized personalized cognitive stimulation program adapted according to cognitive reserve in older adults without cognitive impairment in Primary Care: A randomized clinical trial.

BACKGROUND: Cognitive reserve may influence responsiveness to cognitive interventions, yet it is rarely used to tailor computerized stimulation. OBJECTIVE: To evaluate the effectiveness of a computerized cognitive stimulation program personalized according to cognitive reserve on cognition, reserve-related activities, and digital competence in community-dwelling older adults without cognitive impairment in Primary Care. METHODS: In this randomized clinical trial, 102 adults aged &#x2265;65 years with normal cognitive performance were recruited from three primary care centers in Zaragoza, Spain, and stratified by cognitive reserve level before random allocation to intervention or control. The intervention comprised digital literacy sessions followed by 8 weeks of home-based computerized cognitive stimulation tailored to participants' cognitive reserve profiles and life history. Controls received a single group-based health education session focused on maintaining everyday cognitive activity. Outcomes were assessed at baseline and post-intervention using global cognition (MEC-35), the Cognitive Reserve Questionnaire, the Mobile Device Proficiency Questionnaire-16, and domain-specific neuropsychological tests. A total of 100 participants completed the final evaluation and were included in complete-case analyses. RESULTS: Compared with controls, the intervention group showed greater adjusted post-intervention improvements in global cognition (MEC-35 between-group difference: 1.8 points) and several cognitive measures, including temporal orientation, calculation, attention, praxis, verbal fluency, processing speed, executive functions, and verbal learning. CRQ scores and digital competence also improved, with small-to-large effect sizes. CONCLUSIONS: A computerized cognitive stimulation program adapted according to cognitive reserve appears feasible in Primary Care and may improve cognition, engagement in reserve-related activities, and digital competence in older adults without cognitive impairment.

Humans

Daily low-dose carboplatin or weekly carboplatin plus nab-paclitaxel for concurrent chemoradiotherapy in older patients with locally advanced non-small cell lung cancer (JCOG1914): A randomized phase 3 trial.

BACKGROUND: Daily low-dose carboplatin with concurrent thoracic radiotherapy is the standard treatment for older patients with unresectable locally advanced non-small cell lung cancer (LA-NSCLC) in Japan. METHODS: This open-label phase 3 trial was conducted at 38 institutions in Japan. Patients aged&#xa0;&#x2265;&#xa0;75&#xa0;years with LA-NSCLC were randomly assigned (1:1) to receive daily carboplatin (30&#xa0;mg/m2) or weekly carboplatin (area under the curve, 2&#xa0;mg&#xb7;min/mL) plus nab-paclitaxel (30&#xa0;mg/m2) with thoracic radiotherapy. Durvalumab maintenance therapy was recommended after treatment completion. The primary endpoint was overall survival, which was used to assess the non-inferiority of weekly carboplatin plus nab-paclitaxel compared to daily low-dose carboplatin. RESULTS: From December 2020 to March 2024, 124 patients were enrolled (carboplatin arm, 61 and carboplatin plus nab-paclitaxel arm, 63). In the planned interim analysis, the Bayesian predictive probability indicating the non-inferiority of carboplatin plus nab-paclitaxel compared with carboplatin in the final analysis was 8.0%, leading to early study termination for futility. The median overall survival was not estimable in the carboplatin arm; the estimated value in the carboplatin plus nab-paclitaxel arm was 26.1&#xa0;months (hazard ratio, 1.56; 95% confidence interval, 0.79-3.11; p&#xa0;=&#xa0;0.200). Two treatment-related and seven non-cancer-related deaths occurred in the carboplatin plus nab-paclitaxel arm. Patients in the carboplatin arm had better quality of life than those in the carboplatin plus nab-paclitaxel arm at 6&#xa0;weeks (odds ratio, 0.39; 95% confidence interval, 0.18-0.81; p&#xa0;=&#xa0;0.012). CONCLUSIONS: Daily low-dose carboplatin with concurrent thoracic radiotherapy remains the standard treatment for older patients with unresectable LA-NSCLC in Japan.

Humans

The application of artificial intelligence in healthcare practice: A mapping review of systematic reviews.

Artificial intelligence (AI) is rapidly transforming healthcare practice, with growing evidence supporting its use in diagnosis, prognosis, treatment planning, and operational decision-making. The proliferation of systematic reviews in recent years underscores the need for an updated synthesis of the literature to inform research, policy, and practice. We searched PubMed, Web of Science, Scopus, IEEE Xplore, and CINAHL for systematic reviews and meta-analyses published between 2019 and February 2026. Eligible reviews focused on AI applications in healthcare practice, were peer-reviewed, and written in English. A total of 368 reviews met the inclusion criteria. Publication volume increased steadily, peaking in 2025. AI research was concentrated in high-density domains, such as radiology, oncology, and critical care. Across reviews, diagnostic imaging, electronic health record (EHR) data, and biomarkers/laboratory results accounted for 68% of training data sources, though newer data types, such as wearable device and sensor data, emerged from 2022 onward. Diagnosis, prognosis, and treatment comprised over 80% of AI applications, with novel uses emerging in recent years, such as AI-assisted clinical documentation (e.g., ambient documentation tools) and patient education. Ethical concerns were reported in 78.5% of reviews, with privacy, model accuracy, data and algorithmic bias, and explainability as recurrent themes. The proportion of reviews reporting ethical concerns increased from 2021 to 2025. AI applications in healthcare are expanding in scope, diversifying in data sources, and evolving toward novel clinical and operational uses. The human-centered AI or augmented intelligence paradigm, integrating computational precision with clinical expertise, holds significant promise but will require parallel advances in governance, regulatory frameworks, and ethical oversight to ensure safe adoption.

Artificial Intelligence

A STORM-based protocol for nanoscale imaging and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber.

Stochastic Optical Reconstruction Microscopy (STORM) enables nanoscale mapping of molecular components beyond the diffraction limit; however, its reproducible implementation in hydrophobic polymer matrices remains challenging because fluorescence-labeling specificity, fluorophore photoswitching, three-dimensional localization, chromatic registration, and quantitative image analysis must be carefully controlled. This protocol presents a standardized experimental workflow for dual-color labeling, astigmatism-based three-dimensional STORM acquisition, and quantitative analysis of protein-associated and phospholipid-associated structures in natural rubber (NR). The workflow covers sample pretreatment, Cy5 NHS ester labeling of protein-associated primary amines, DiI labeling of phospholipid-rich domains, STORM imaging-buffer preparation, three-dimensional single-molecule localization, dual-channel registration, generation of standardized xy projections, aggregate-size analysis, and projected lateral spatial correlation assessment. Reproducibility is supported by defined acquisition and localization criteria, three independent sample preparations with at least five fields of view analyzed per condition, and unlabeled, single-color, dye-only matrix, and processing-associated Cy5 controls. Mean lateral localization precisions of 11.8&#x202f;&#xb1;&#x202f;2.3&#x202f;nm for Cy5 and 13.5&#x202f;&#xb1;&#x202f;2.9&#x202f;nm for DiI were obtained, while two-dimensional Fourier ring correlation analysis of the xy projections yielded effective lateral image resolutions of approximately 25 and 28&#x202f;nm, respectively. Image-based particle segmentation and localization-coordinate-based density-based spatial clustering of applications with noise (DBSCAN) were applied to standardized xy projections as complementary quantitative approaches. Application of the protocol to untreated, centrifuged, and protease-treated NR samples demonstrated treatment-associated changes in the detected abundance and projected size distributions of protein- and phospholipid-associated aggregates, together with a non-monotonic change in their projected lateral spatial correlation. These observations describe alterations in nanoscale organization but do not, by themselves, establish stable protein-phospholipid complex formation. Unlike previous studies that primarily demonstrated the feasibility of STORM imaging in rubber materials, the principal contribution of this work is an end-to-end, step-by-step protocol incorporating defined controls, three-dimensional localization, image-quality metrics, chromatic-registration procedures, and complementary quantitative-analysis pipelines for non-expert users. The workflow may be adaptable to other hydrophobic polymers and soft-material systems after appropriate optimization and validation.

Rubber

Diagnostic Performance of Machine Learning for Systemic Lupus Erythematosus: Systematic Review and Meta-Analysis.

BACKGROUND: Early and accurate diagnosis of systemic lupus erythematosus (SLE) and its organ involvement is essential. Previous reviews of machine learning (ML) in SLE combined heterogeneous tasks and validation strategies and may have overinterpreted model performance. OBJECTIVE: This study evaluated the diagnostic performance of ML and deep learning (DL) models for 3 clinically distinct SLE-related tasks: SLE classification or diagnosis, lupus nephritis (LN) diagnosis, and neuropsychiatric systemic lupus erythematosus (NPSLE) discrimination. We also assessed methodological quality and certainty of evidence. METHODS: PubMed, Embase, Cochrane Library, Web of Science, and IEEE Xplore were searched from January 2014 to April 2026. Eligible peer-reviewed diagnostic accuracy studies developed or validated ML or DL models for 1 of the 3 prespecified tasks, used an accepted reference standard, and provided data for a 2&#xd7;2 contingency table. Bivariate random-effects meta-analyses with the Hartung-Knapp-Sidik-Jonkman adjustment were used to pool sensitivity and specificity. We reported 95% prediction intervals (PIs), assessed risk of bias using the Quality Assessment of Diagnostic Accuracy Studies for Artificial Intelligence tool (QUADAS-AI; Viknesh Sounderajah [Imperial College London]), and evaluated certainty of evidence using the Grading of Recommendations Assessment, Development, and Evaluation framework for diagnostic test accuracy. RESULTS: Twenty-nine studies were included: 17 for SLE classification, 5 for LN diagnosis, and 7 for NPSLE discrimination. In the primary task-stratified analysis, pooled sensitivity was 0.91 (95% CI 0.86-0.94; 95% PI 0.56-0.99), and pooled specificity was 0.94 (95% CI 0.91-0.96; 95% PI 0.69-0.99), with low heterogeneity (I&#xb2;=23.9% and 22.9%, respectively). DL models showed a sensitivity of 0.93 and specificity of 0.95, compared with 0.88 and 0.94 for traditional ML models. Certainty of evidence was high for most analyses but low for LN diagnosis because of inconsistency and imprecision. All studies were retrospective, and only 9 of 29 (31%) performed independent external validation. Overall risk of bias was high or unclear in 22 of 29 (75.9%) studies. No study reported model calibration, decision-curve analysis, or net clinical benefit. CONCLUSIONS: ML models showed promising diagnostic accuracy across 3 distinct SLE-related tasks, but wide PIs, limited external validation, and pervasive risk of bias restrict conclusions about real-world generalizability. Prospective multicenter studies with standardized tasks and reference standards, independent external validation, and formal assessment of calibration and clinical utility are required before clinical implementation.

Humans

Changes in hippocampal functional connectivity and volume associated with cognitive improvement and decline in amnestic mild cognitive impairment following computerized cognitive training.

BACKGROUND: The hippocampus influences the outcomes of amnestic mild cognitive impairment (aMCI) and undergoes different changes during the cognitive decline or recovery of aMCI compared to elderly individuals with normal cognition, which may reveal disease-dependent neurodegeneration or plasticity. We first aimed to investigate the hippocampal changes associated with cognitive changes in aMCI using a combined case-control study design. METHODS: In total, 50&#x202f;aMCI individuals and 50 healthy controls (HCs) were recruited in Shenyang, China, and separately randomized into training and control groups: aMCI training group, aMCI no training group, HC training group, and HC no training group. The aMCI and HC training groups received computerized cognitive training (CCT) thrice weekly for 12 weeks. Cognitive assessments and MRI data were collected at baseline and follow-up. RESULTS: The primary outcome was significant CCT&#xd7;diagnosis interaction effect on the change in cognitive performance as measured by clock drawing test (CDT) scores (F&#x202f;=&#x202f;4.322, P&#x202f;=&#x202f;0.041); this interaction was driven by CCT specifically in aMCI (F&#x202f;=&#x202f;4.465, P&#x202f;=&#x202f;0.038). Significant CCT&#xd7;diagnosis interaction effects of right-hippocampal FC changes were observed in the bilateral precuneus/cuneus (Pvoxel<0.05) driven by CCT in aMCI (F&#x202f;=&#x202f;5.429, P&#x202f;=&#x202f;0.023), and in the left superior temporal gyrus/middle temporal gyrus (STG/MTG, Pvoxel<0.05), driven by CCT of only in HCs (F&#x202f;=&#x202f;6.587, P&#x202f;=&#x202f;0.013). A significant interaction effect of left-hippocampal FC changes were observed in the right triangular part of the inferior frontal gyrus (IFGtriang, Pvoxel<0.05), driven by CCT in aMCI and HCs (F&#x202f;=&#x202f;6.550, P&#x202f;=&#x202f;0.013; F&#x202f;=&#x202f;7.097, P&#x202f;=&#x202f;0.010). No significant interaction effect on the change in hippocampal GMV was noted (P&#x202f;>&#x202f;0.05). CONCLUSION: CCT can improve the visuospatial ability of aMCI, which is reflected by the CDT scores. CCT can alter hippocampal FC in the bilateral precuneus/cuneus, the right IFGtriang, and the left STG/MTG. The hippocampal GMV is difficult to change in both HCs and aMCI during the cognitive decline. REGISTRATION NUMBER: ChiCTR1900026849. DATE OF REGISTRATION: 24 October 2019 NAME OF TRIAL REGISTRY: Chinese Clinical Trial Registry (ChiCTR).

Humans