Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Radiometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Theoretical, experimental, and computational aspects of optical property determination of turbid media by using frequency-domain laser infrared photothermal radiometry.

In this work, the optical and thermal properties of tissuelike materials are measured by using frequency-domain infrared photothermal radiometry. This technique is better suited for quantitative multiparameter optical measurements than the widely used pulsed-laser photothermal radiometry (PPTR) because of the availability of two independent signal channels, amplitude and phase, and the superior signal-to-noise ratio provided by synchronous lock-in detection. A rigorous three-dimensional (3-D) thermal-wave formulation with a 3-D diffuse and coherent photon-density-wave source is applied to data from model phantoms. The combined theoretical, experimental, and computational methodology shows good promise with regard to its analytical ability to measure optical properties of turbid media uniquely, as compared with PPTR, which exhibits uniqueness problems. From data sets obtained by using calibrated test phantoms, the reduced optical scattering and absorption coefficients were found to be within 20% and 10%, respectively, of the values independently derived by using Mie theory and spectrophotometric measurements.

Journal Article↗

Noninvasive thermometry using multiple-frequency-band radiometry: a feasibility study.

The potential use of multiple-frequency-band radiometry as a means of noninvasive sensing of one-dimensional temperature profiles is presented in this communication. The radiative energy transfer equation is solved numerically. Ideal-condition thermal noise spectra and distributions of received energy, associated with specific temperature-depth profiles, are presented. Performance characteristics are discussed.

Humans↗

Measurement of the optical and thermal properties of biliary calculi using pulsed photothermal radiometry.

The optical absorption coefficients for biliary calculi are important in understanding the mechanism of laser-induced stone fragmentation. However, the heterogeneous composition of calculi and difficulties in producing optically thin samples prevent conventional spectrophotometric measurement techniques from being used. To overcome these limitations, we used a pulsed photothermal radiometry system to measure the optical absorption coefficients and thermal diffusivities of various biliary calculi. In the wavelength range examined (350-1,060 nm), there was strong optical absorption which was greater for pigment stones than for cholesterol stones. The data support the theory that the initiation of the plasma accompanying laser fragmentation of calculi is a thermal process.

Absorption↗

Detection of air emboli in radiographic contrast media by microwave radiometry.

To evaluate the efficacy of a microwave radiometry system in detecting in-line air emboli in radiographic contrast media, air emboli ranging in volume from 0.1 to 0.005 ml were introduced into ionic (ioxaglate) and nonionic (iohexol) contrast media at 22 or 37 degrees pumped at flow rates of 16.7, 180 or 300 ml/min through polyvinlychloride tubing with an inner diameter of 0.100 inches (2.54 mm) over which was fitted a radiometer antenna connected to a Microwave Medical System F+ radiometer and a computerized data acquisition system. A total of 400 determinations were run, with 10 replicate determinations for each unique set of experimental conditions. The success of air emboli detection was not significantly related to contrast media (p = 0.73) or contrast temperature (p = 0.68). Embolus volume (p < 0.0001) and pump speed (p < 0.0001) were significant factors affecting system performance. The system could reliably detect small (0.005 ml) emboli in both ionic and nonionic low-osmolar contrast media.

Air↗

[The value of radiometry in the treatment planning of inoperable carcinomas of the cervix (author's transl)].

A retrospective study of 731 patients with carcinoma of the cervix in various stages showed that recurrences were most common in patients treated with combined local radium application and irradiation of the parametrium. The basis for radiation treatment planning had been radiometry after the radium application. A comparison of the position of the uterus as shown by this method with computer tomography carried out in 40 patients in the position used for irradiation showed that in more than half these patients there was a significant difference in the results. It therefore appears that it is necessary to determine the position of the uterus by computer tomography in all patients if the applicator deviates from the median line by more than 10 degrees and if the parametrium is not fixed. Frequently it is possible, at an advanced stage, to use a rotational method instead of repeated radium applications.

Brachytherapy↗

Determination of optical properties of turbid media using pulsed photothermal radiometry.

Pulsed photothermal radiometry (PPTR) measures blackbody radiation emitted by a sample after absorption of an optical pulse. Three techniques for obtaining the absorption coefficient of absorbing-only, semi-infinite samples are examined and shown to give comparable results. An analytic theory for the time dependence of the PPTR signal in semi-infinite scattering and absorbing media has been derived and tested in a series of controlled gel phantoms. This theory, based on the diffusion approximation of the radiative transport equation, is shown to model the time course of the detected signal accurately. Furthermore, when the incident fluence is known, the theory can be used in a non-linear, two-parameter fitting algorithm to determine the absorption and reduced scattering coefficients of a turbid sample with an accuracy of 10-15% for transport albedos ranging from 0.42-0.88.

Algorithms↗

Pulsed photothermal radiometry in optically transparent media containing discrete optical absorbers.

A description of heat transport by conduction and radiation in inhomogeneous materials following absorption of a brief optical pulse is presented, and investigated experimentally using pulsed photothermal radiometry (PPTR). The model indicates that the role of radiation as an intramedium heat transfer modality increases with increasing temperatures and decreasing infrared (IR) absorption of the medium. However, for the range of conditions analysed in this study, conductive transfer dominates. Thus, the inclusion of radiation does not significantly perturb the internal temperature profiles, although it does influence the radiometric emission from the sample, and hence the PPTR signal. The thermal confinement effects described in this study may be relevant in photomedicine, for example in pulsed laser irradiation of tissues containing small absorbing targets.

Algorithms↗

Accuracy of subsurface temperature distributions computed from pulsed photothermal radiometry.

Pulsed photothermal radiometry (PPTR) is a non-contact method for determining the temperature increase in subsurface chromophore layers immediately following pulsed laser irradiation. In this paper the inherent limitations of PPTR are identified. A time record of infrared emission from a test material due to laser heating of a subsurface chromophore layer is calculated and used as input data for a non-negatively constrained conjugate gradient algorithm. Position and magnitude of temperature increase in a model chromophore layer immediately following pulsed laser irradiation are computed. Differences between simulated and computed temperature increase are reported as a function of thickness, depth and signal-to-noise ratio (SNR). The average depth of the chromophore layer and integral of temperature increase in the test material are accurately predicted by the algorithm. When the thickness/depth ratio is less than 25%, the computed peak temperature increase is always significantly less than the true value. Moreover, the computed thickness of the chromophore layer is much larger than the true value. The accuracy of the computed subsurface temperature distribution is investigated with the singular value decomposition of the kernel matrix. The relatively small number of right singular vectors that may be used (8% of the rank of the kernel matrix) to represent the simulated temperature increase in the test material limits the accuracy of PPTR. We show that relative error between simulated and computed temperature increase is essentially constant for a particular thickness/depth ratio.

Algorithms↗

Non-invasive microwave radiometry thermometry.

Near-field microwave radiometry and radiometric imaging are non-invasive techniques that are able to provide temperature information at a depth of up to several centimetres in subcutaneous tissues. They are based on the measurement of microwave electromagnetic thermal noise. This paper describes the basic principles, measurement methods and limitations of the techniques and the results of clinical studies, and it reviews recent progress.

Hot Temperature↗

Hand-held pulsed photothermal radiometry system to estimate epidermal temperature rise during laser therapy.

BACKGROUND/PURPOSE: During laser therapy of port wine stain (PWS) birthmarks in human skin, measurement of the epidermal temperature rise (DeltaT(epi)) is important to determine the maximal permissible light dose. In order to measure DeltaT(epi) on a specific PWS skin site, we developed an AC-coupled hand-held pulsed photothermal radiometry (PPTR) system, which overcomes the in vivo measurement limitations of bench-top systems. METHODS: The developed hand-held PPTR system consists of an infrared (IR) lens, AC-coupled thermoelectrically cooled IR detector, laser hand-piece holder, and positioning aperture. The raw AC-coupled signal was integrated to obtain a higher signal-to-noise ratio (SNR). The experimental temperature difference (DeltaT) calibration was compared with theoretical computations. In vitro and in vivo measurements of DeltaT were performed with a tissue phantom as a function of radiant exposure and human subject as a function of melanin concentration, respectively. RESULTS: The integrated AC-coupled signal provided higher SNR as compared with the raw AC-coupled signal. The experimental DeltaT calibration resulted in good agreements with the theoretical results. The in vitro and in vivo results also presented good agreements with theory. CONCLUSIONS: A fiber-free, hand-held AC-coupled PPTR system is capable of accurate epidermis temperature rise (DeltaT(epi)) measurements of human skin during pulsed laser exposure.

Calibration↗

Pulsed photothermal radiometry as a method for investigating blood vessel-like structures.

Pulsed photothermal radiometry (PPTR) is known to be suitable for in vivo investigations of tissue optical properties. As a noncontact, nondestructive method it is a very attractive candidate for on-line dosimetry of laser treatments that rely on thermal laser-tissue interaction. In this article, we extend the one-dimensional (1D) analytical formalism that has widely been used to describe PPTR signals to a two-dimensional treatment of a simplified model of a blood vessel. This approach leads to quantitative description of a PPTR signal that, unlike in an 1D treatment, not only shows changes in time, but also varies in space. Using this approach, we are able to gain instructive understanding on how target characteristics of a blood vessel-like structure influence such a spatiotemporal PPTR signal. Likewise, the ability of extracting target features from those measurements is evaluated. Subsequently, we present experimental realization of the idealized model of a blood vessel as used in our theory. Comparison of actual PPTR measurements with theoretical predictions allow vessel localization laterally and in depth. Using our setup, we furthermore demonstrate the influence of flow inside the vessel on the measured signal.

Blood Vessels↗

Computational model to evaluate port wine stain depth profiling using pulsed photothermal radiometry.

We report on development of an optical-thermal model to evaluate the use of pulsed photothermal radiometry (PPTR) for depth profiling of port wine stain (PWS) skin. In the model, digitized histology sections of a PWS biopsy were used as the input skin geometry. Laser induced temperature profiles were reconstructed from simulated PPTR signals by applying an iterative, non-negatively constrained conjugate gradient algorithm. Accuracy of the following PWS skin characteristics extracted from the reconstructed profiles was determined: (1) average epidermal thickness (z(epi)), (2) maximum epidermal temperature rise (DeltaT(epi,max)), (3) depth of PWS upper boundary (z(PWS)), and (4) depth of maximum PWS temperature rise (z(PWS,max)). Comparison of the actual and reconstructed profiles from PPTR data revealed a good match for all four PWS skin characteristics. Results of this study indicate that PPTR is a viable approach for depth profiling of PWS skin.

Algorithms↗

Nonintrusive, noncontacting frequency-domain photothermal radiometry and luminescence depth profilometry of carious and artificial subsurface lesions in human teeth.

Nonintrusive, noncontacting frequency-domain photothermal radiometry (FD-PTR or PTR) and frequency-domain luminescence (FD-LUM or LUM) have been used with 659-nm and 830-nm laser sources to detect artificial and natural subsurface defects in human teeth. The major findings of this study are (1) PTR is sensitive to very deep (>5 mm) defects at low modulation frequencies (5 Hz). Both PTR and LUM amplitudes exhibit a peak at tooth thicknesses of ca. 1.4 to 2.7 mm. Furthermore, the LUM amplitude exhibits a small trough at ca. 2.5 to 3.5 mm. (2) PTR is sensitive to various defects such as a deep carious lesion, a demineralized area, an edge, a crack, and a surface stain, while LUM exhibits low sensitivity and spatial resolution. (3) PTR frequency scans over the surface of a fissure into demineralized enamel and dentin show higher amplitude than those for healthy teeth, as well as a pronounced curvature in both the amplitude and phase signal channels. These can be excellent markers for the diagnosis of subsurface carious lesions. (4) PTR amplitude frequency scans over the surface of enamels of variable thickness exhibit strong thickness dependence, thus establishing depth profilometric sensitivity to subsurface interfaces such as the dentin/enamel junction.

Dental Caries↗

Accurate measurement of blood vessel depth in port wine stained human skin in vivo using pulsed photothermal radiometry.

We report on application of pulsed photothermal radiometry (PPTR) to determine the depth of port wine stain (PWS) blood vessels in human skin. When blood vessels are deep in the PWS skin (>100 microm), conventional PPTR depth profiling can be used to determine PWS depth with sufficient accuracy. When blood vessels are close or partially overlap the epidermal melanin layer, a modified PPTR technique using two-wavelength (585 and 600 nm) excitation is a superior method to determine PWS depth. A direct difference approach in which PWS depth is determined from a weighted difference of temperature profiles reconstructed independently from two-wavelength excitation is demonstrated to be appropriate for a wider range of PWS patients with various blood volume fractions, blood vessel sizes, and depth distribution. The most superficial PWS depths determined in vivo by PPTR are in good agreement with those measured using optical Doppler tomography (ODT).

Algorithms↗

Spatial resolution measurements for passive microwave radiometry using a tissue-equivalent phantom.

A tissue-equivalent "hot" line source phantom is described for assessing spatial resolution in passive microwave radiometry systems. LSFs were measured for two rectangular waveguide antennas connected to a 4.7-GHz radiometer. The normalized LSFs and corresponding modulation transfer functions were found to be independent of line source temperature, but dependent upon antenna size, orientation, and line source depth.

Biophysical Phenomena↗

Diagnosis of pit and fissure caries using frequency-domain infrared photothermal radiometry and modulated laser luminescence.

Non-intrusive, non-contacting frequency-domain photothermal radiometry (FD-PTR or PTR) and frequency-domain luminescence (FD-LUM or LUM) have been used with 659- and 830-nm laser sources to assess the pits and fissures on the occlusal surfaces of human teeth. Fifty-two human teeth were examined with simultaneous measurements of PTR and LUM and were compared to conventional diagnostic methods including continuous (dc) luminescence (DIAGNOdent), visual inspection and radiographs. To compare each method to the others, sensitivities and specificities were calculated by using histological observations as the gold standard. With the combined criteria of four PTR and LUM signals (two amplitudes and two phases), it was found that the sensitivity of this method was much higher than any of the other methods used in this study, whereas the specificity was comparable to that of dc luminescence diagnostics. Therefore, PTR and LUM, as a combined technique, has the potential to be a reliable tool to diagnose early pit and fissure caries and could provide detailed information about deep lesions. Using the longer wavelength (830-nm) laser source, it has been shown that detection of deeper subsurface lesions than the 659-nm probe provides is possible.

Body Temperature↗

Quantitative dental measurements by use of simultaneous frequency-domain laser infrared photothermal radiometry and luminescence.

Modulated (frequency-domain) infrared photothermal radiometry (PTR) is used as a dynamic quantitative dental inspection tool complementary to modulated luminescence (LM) to quantify sound enamel or dentin. A dynamic high-spatial-resolution experimental imaging setup, which can provide simultaneous measurements of laser-induced modulated PTR and LM signals from defects in teeth, has been developed. Following optical absorption of laser photons, the experimental setup can monitor simultaneously and independently the nonradiative (optical-to-thermal) energy conversion by infrared PTR and the radiative deexcitation by LM emission. The relaxation lifetimes (tau1, tau2) and optical absorption, scattering, and spectrally averaged infrared emission coefficients (mu(alpha), mu(s), mu(IR)) of enamel are then determined with realistic three-dimensional LM and photothermal models for turbid media followed by multiparameter fits to the data. A quantitative band of values for healthy enamel with respect to these parameters can be generated so as to provide an explicit criterion for the assessment of healthy enamel and, in a future extension, to facilitate the diagnosis of the onset of demineralization in carious enamel.

Animals↗

Depth profiling of laser-heated chromophores in biological tissues by pulsed photothermal radiometry.

A solution method is proposed to the inverse problem of determining the unknown initial temperature distribution in a laser-exposed test material from measurements provided by infrared radiometry. A Fredholm integral equation of the first kind is derived that relates the temporal evolution of the infrared signal amplitude to the unknown initial temperature distribution in the exposed test material. The singular-value decomposition is used to demonstrate the severely ill-posed nature of the derived inverse problem. Three inversion methods are used to estimate solutions for the initial temperature distribution. A nonnegatively constrained conjugate-gradient algorithm using early termination is found superior to unconstrained inversion methods and is applied to image the depth of laser-heated chromophores in human skin.

Absorption↗