Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polymers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Preparation of solid dispersions of nonsteroidal anti-inflammatory drugs with acrylic polymers and studies on mechanisms of drug-polymer interactions.

This work studied the mechanisms of interaction between Eudragit RS100 (RS) and RL100 (RL) polymers with 3 nonsteroidal anti-inflammatory drugs: diflunisal (DIF), flurbiprofen (FLU), and piroxicam (PIR). Solid dispersions of polymers and drugs at different weight ratios were prepared by coevaporation of their ethanol solutions. The resulting coevaporates were characterized in the solid state (Fourier-transformed infrared spectroscopy (FT-IR) IR, differential scanning calorimetry, powder-x-ray diffractometry) as well as by studying the in vitro drug release in a gastroenteric environment. Absorption tests from drug solutions to the solid polymers were also performed to better explain the mechanism of interactions between them. The preparative conditions did not induce changes in the crystalline state of the drugs (amorphization or polymorphic change). Drugs strongly interacted with the ammonium groups present in polymers, giving an electrostatic interaction that reinforced the mere physical dispersion of drug molecules within polymer networks. Such interactions are related to the chemical structure of the drugs and to their dissociated or undissociated state. The dispersion of drugs in the polymer matrices strongly influenced their dissolution rate, which appeared slower and more gradual than those of the pure drugs, when polymer ratios were increased. RL coevaporates usually displayed higher dissolution rates. The kinetic evaluation of the dissolution profile, however, suggested that both the drug solubility in the external medium and its diffusion capacity within the polymer network are involved. In the sorption experiments, RL showed a greater adsorptive capacity than RS, in relation to the greater number of quaternary ammonium functions, which behave as activity sites for the electrostatic interactions. In the presence of Tris-HCl buffer (pH 7.4), drug adsorption was reduced, as a consequence of the competition of the chloride ions with drug anions for the polymer binding sites. In general, DIF and FLU displayed a similar interaction with RS and RL active sites; PIR's was different. The different molecular structures of these agents can justify such findings. The presence of a carboxyl group (instead of another dissociable acidic moiety, like the hydroxy-enolic one in the PIR molecule) could help explain the strong interaction with RS and RL polymers' quaternary ammonium centers. Preliminary studies like ours are important in helping develop better forecasting and increasing the understanding of the incorporation/release behavior of drugs from particulate delivery systems that can be made from these polymers.

Acrylic Resins↗

Thermal property and processability of elastomeric polymer alloy composed of segmented polyurethane and phospholipid polymer.

To develop a thermoplastic elastomer with high blood compatibility, a 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was blended with the segmented polyurethane (SPU) for preparing the polymer alloy. A tensile strength measurement was carried out to evaluate its mechanical strength. The mechanical strength of the SPU/MPC polymer alloy is the same as that of the original SPU and sufficient for use in medical applications. The thermal properties of the polymer alloy were evaluated by differential scanning calorimetry (DSC). The DSC curves indicated that the MPC polymer blended into the SPU did not affect the hard segment domain of the SPU. The SPU/MPC polymer alloy can be processed by heat treatment at 150 degrees C. Even after heat treatment, the SPU/MPC polymer alloy showed good mechanical properties, and MPC units were observed on the surface. Protein adsorption from human plasma was observed to evaluate the blood compatibility of the polymer alloy. The SPU/MPC polymer alloy suppressed protein adsorption on the surface before and after the heat treatment. Based on these results, it is concluded that the SPU/MPC polymer alloy has an excellent potential for application in various medical devices.

Adsorption↗

Molecular modeling of polymers 16. Gaseous diffusion in polymers: a quantitative structure-property relationship (QSPR) analysis.

PURPOSE: The purpose of this study was to identify the key physicochemical molecular properties of polymeric materials responsible for gaseous diffusion in the polymers. METHODS: Quantitative structure-property relationships, QSPRs were constructed using a genetic algorithm on a training set of 16 polymers for which CO2, N2, O2 diffusion constants were measured. Nine physicochemical properties of each of the polymers were used in the trial basis set for QSPR model construction. The linear cross-correlation matrices were constructed and investigated for colinearity among the members of the training sets. Common water diffusion measures for a limited training set of six polymers was used to construct a "semi-QSPR" model. RESULTS: The bulk modulus of the polymer was overwhelmingly found to be the dominant physicochemical polymer property that governs CO2, N2 and O2 diffusion. Some secondary physicochemical properties controlling diffusion, including conformational entropy, were also identified as correlation descriptors. Very significant QSPR diffusion models were constructed for all three gases. Cohesive energy was identified as the main correlation physicochemical property with aqueous diffusion measures. CONCLUSIONS: The dominant role of polymer bulk modulus on gaseous diffusion makes it difficult to develop criteria for selective transport of gases through polymers. Moreover, high bulk moduli are predicted to be necessary for effective gas barrier materials. This property requirement may limit the processing and packaging features of the material. Aqueous diffusion in polymers may occur by a different mechanism than gaseous diffusion since bulk modulus does not correlate with aqueous diffusion, but rather cohesive energy of the polymer.

Carbon Dioxide↗

Light-sensitive fusion between polymer-coated liposomes following physical anchoring of polymerisable polymers onto lipid bilayers by self-assembly.

Delivery of therapeutics (drugs, radionuclides or genes) in vivo can be optimized when carried by a targeting delivery vehicle such as a surfactant vesicle, polymeric micelle or other polymer-coated colloidal particulate. In the present communication, we propose a general method based on self-assembly principles, to construct lipid-polymer bilayer vesicles whose featured characteristics may be altered according to the polymer molecule used, thus be easily designed along the needs of a particular delivery application. Polymer molecules containing non-polymerizable (polypropylene) and polymerisable (methacrylate) hydrophobic groups were used to construct lipid-polymer vesicles by following two different methods of preparation. In accord with our previous findings, when both types of polymer molecules are added to pre-formed liposomes, only weak adsorption onto the lipid surface occurs. Preparation of the vesicles by pre-mixing the lipid and polymer molecules has proved essential in order to allow the hydrophobic blocks of the copolymers to participate as integral parts of the bilayer. Anchoring of a polymerisable polymer onto the lipid bilayer by hydrophobic interactions, resulted in steric stabilization of the vesicles. When UV polymerization of the bilayer-incorporated [Methyl(PEG)2000MA] polymer was induced, inter-vesicle fusion was triggered. Direct cryo-EM imaging of fusion between the PEG-coated liposomes has been observed. Such sterically stabilised fusogenic vesicles were constructed as potential triggered-release delivery systems, responsive to a variety of external stimuli depending on the type of polymerisable, hydrophobic group in the polymer molecule. By altering the properties of the incorporated hydrophobic group, liposomes able to fuse in response to initiators milder than UV light, such as green or red light, sound, temperature, oxygen or pH can be engineered.

Cryoelectron Microscopy↗

Molar mass profiling of synthetic polymers by free-solution capillary electrophoresis of DNA-polymer conjugates.

The molar mass distribution of a polymer sample is a critical determinant of its material properties and is generally analyzed by gel permeation chromatography or more recently, by MALDI-TOF mass spectrometry. We describe here a novel method for the determination of the degree of polymerization of polydisperse, uncharged, water-soluble polymers (e.g., poly(ethylene glycol) (PEG)), based upon single-monomer resolution of DNA-polymer conjugates by free-solution capillary electrophoresis. This is accomplished by end-on covalent conjugation of a polydisperse, uncharged polymer sample (PEG) to a monodisperse, fluorescently labeled DNA oligomer, followed by electrophoretic analysis. The monodisperse, charged DNA "engine" confers to each conjugate an equal amount of electromotive force, while the varying contour lengths of the uncharged, polydisperse polymers engender different amounts of hydrodynamic drag. The balance of electromotive and hydrodynamic forces enables rapid, high-resolution separation of the DNA-polymer conjugates as a function of the size of the uncharged PEG tail. This provides a profile of the molar mass distribution of the original polymer sample that can be detected by laser-induced fluorescence through excitation of the dye-labeled DNA. We call this method free solution conjugate electrophoresis (FSCE). Theory-based analysis of the resulting electrophoresis data allows precise calculation of the degree of polymerization of the PEG portion of each conjugate molecule. Knowledge of the molecular mass of the uncharged polymer's repeat unit allows for direct calculation of the molar mass averages as well as sample polydispersity index. The results of these analyses are strikingly reminiscent of MALDI-TOF spectra taken of the same PEG samples. PEG samples of 3.4-, 5-, and 20-kDa nominal average molar mass were analyzed by FSCE and MALDI-TOF; the values of the molar mass averages, Mw and Mn, typically agree to within 5%. Measurements and molar mass calculations are performed without any internal standards or calibration. Moreover, when DNA-polymer conjugate analysis is performed in a chip-based electrophoresis system, separation is complete in less than 13 min. FSCE offers an alternative to MALDI-TOF for the characterization of uncharged, water-soluble polymers that can be uniquely conjugated to DNA.

DNA↗

The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: denture base polymers induce apoptosis and necrosis.

Eluates from poly(methyl methacrylate)-based denture base polymers have recently been found to enhance death by apoptosis and necrosis in U-937 human monoblastoid cells. The present study investigated the potential of such polymers to induce apoptosis and/or necrosis and to alter clonogenicity in L929 murine fibroblasts. A fibroblast cell line was chosen because the impairment of fibroblasts subjacent to denture bases may result in a weaker or more permeable mucosa. Two aspects were addressed: the effect of direct contact with the denture base polymers and the effect of eluates extracted from the polymers. For this purpose L929 fibroblasts were seeded on disks manufactured from three heat-polymerized and four autopolymerized denture base polymers or in different concentrations of their eluates. The effects were evaluated by light, fluorescent, confocal and electron microscopy, counting of colonies, and flow cytometry. Disks and eluates of all polymers enhanced cell death by apoptosis and necrosis in L929 cells and decreased their clonogenic potential in a dose-dependent manner. Apoptosis was the main form of cell death. In general, the deleterious effects were stronger when cells were plated directly on the polymer disks than in the eluates. The autopolymerized polymers, except one, yielded higher percentages of apoptosis and necrosis than the heat-polymerized polymers. The results of the study indicated that poly(methyl methacrylate)-based denture base polymers trigger death-signals in L929 fibroblasts and open doors for possible modulation of the cell/biomaterial interaction.

Animals↗

Capillary zone electrophoresis of proteins in semidilute polymer solutions: inter- and intra-polymer predictability of size-dependent retardation.

The retardation of three "spherical" proteins with Stokes' radii of 2.0, 2.4, and 3.0 nm (35-104 kDa) was studied in capillary zone electrophoresis (CZE), using semidilute solutions of polyethylene glycol (PEG), linear polyacrylamide (PA), and polyvinyl alcohol (PVA). The purpose was to test the models predicting that the ratio of particle radius, R, to the mesh size of polymer network (the correlation or screening length of a semidilute polymer solution), xi, directly governs the size-dependent retardation in the form: mu/muo = exp (-R/xi). Here xi = kc-0.75, where c is polymer concentration and the numerical factor kcan be calculated based on polymer molecular weight. In application to polymers in a "good solvent" (PA and PEG in the aqueous buffer) and to proteins of 2.4 and 3.0 nm radius, that relation between relative mobility and R/xi was found to be obeyed for PA, while for PEG the value of k derived from retardation experiments significantly exceeded that which was theoretically calculated. Thus, the retardation appears to be polymer-specific, rather than universal, even for polymers in a "good solvent". It is suggested that, in that case, retardation of proteins of R > 2 nm be quantitatively described in the form mu/muo = exp[-p(R/xi], where p is a parameter depending on monomer type and/or polymer polydispersity. For PVA, the logarithm of mu/muo was found to be linearly related to c (in line with the prediction that the aqueous buffer is a "poor solvent" for this polymer) and to be near-independent of R.

Animals↗

pH-independent release of a basic drug from pellets coated with the extended release polymer dispersion Kollicoat SR 30 D and the enteric polymer dispersion Kollicoat MAE 30 DP.

The objective of this study was to obtain pH-independent release profiles from coated pellets containing drugs with pH-dependent solubility. pH-independent release of the basic model drug verapamil HCl was achieved by coating with a combination of the neutral polymer dispersions Kollicoat SR 30 D (aqueous dispersion of polyvinyl acetate) and the enteric polymer dispersion Kollicoat MAE 30 DP (aqueous dispersion of methacrylic acid and ethyl acrylate copolymer; methacrylic acid copolymer type C). The two polymers where applied either as separate layers (enteric polymer + extended release polymer or vice versa) or as a polymer blend. A careful balance of the ratios of the polymers allowed the achievement of a pH-independent release. Higher amounts of the enteric polymer in the polymer blend resulted in a reversal of the pH-dependency, e.g. a faster release at pH 6.8 than in 0.1 N HCl.

Delayed-Action Preparations↗

Placebo-controlled trial of safety and efficacy of intraoperative controlled delivery by biodegradable polymers of chemotherapy for recurrent gliomas. The Polymer-brain Tumor Treatment Group.

Chemotherapy for brain tumours has been limited because of difficulty in achieving adequate exposure to the tumour without systemic toxicity. We have developed a method for local sustained release of chemotherapeutic agents by their incorporation into biodegradable polymers. Implantation of the drug-impregnated polymer at the tumour site allows prolonged local exposure with minimal systemic exposure. We conducted a randomised, placebo-controlled, prospective study to evaluate the effectiveness of biodegradable polymers impregnated with carmustine to treat recurrent malignant gliomas. In 27 medical centres, 222 patients with recurrent malignant brain tumours requiring re-operation were randomly assigned to receive surgically implanted biodegradable polymer discs with or without 3.85% carmustine. Randomisation balanced the treatment groups for all of the prognostic factors examined. Median survival of the 110 patients who received carmustine polymers was 31 weeks compared with 23 weeks for the 112 patients who received only placebo polymers (hazard ratio = 0.67, p = 0.006, after accounting for the effects of prognostic factors). Among patients with glioblastoma, 6-month survival in those treated with carmustine-polymer discs was 50% greater than in those treated with placebo (mortality = 32 of 72 [44%] vs 47 of 73 [64%], p = 0.02). There were no clinically important adverse reactions related to the carmustine polymer, either in the brain or systemically. Interstitial chemotherapy delivered with polymers directly to brain tumours at the time of surgery seems to be a safe and effective treatment for recurrent malignant gliomas.

Biodegradation, Environmental↗

Polymer chemical structure is a key determinant of physicochemical and colloidal properties of polymer-DNA complexes for gene delivery.

Polyplexes are now emerging as potentially useful vectors for gene therapy. To improve our understanding of how the chemical structure of the polymer affects the properties of these systems, a series of structurally related polymers, the linear poly(amidoamine)s (PAAs), have been examined for their abilities to form complexes with DNA. Structure-dependent differences in DNA binding are shown by gel electrophoretic retardation of DNA and thermal transition analyses. Two PAAs, NG28 and NG30, stand out as having high affinity DNA binding characteristics, similar to the model homopolypeptide, poly-L-lysine. In addition, differences in complex formation, particle size and surface charge are displayed for the different polymer-DNA systems. Electron microscopy studies showed that the polymers condensed DNA into similar unit structures but only complexes with NG30 did not undergo agglomeration. This was attributed to an excess of complexed polymer forming a shell of uncomplexed polymer chain segments around a condensed DNA-polymer core. The transfection activities of these polymer complexes differ greatly, and some of these differences can be explained in a multifactorial way by the physicochemical and colloidal properties. It is concluded that polymer chemical structure dictates the apparent affinity of DNA binding, and also several of the important colloidal characteristics of the resulting complexes.

Chloroquine↗

Dependence of turbidity oscillations of self-oscillating polymers on the selective recognition of the crown ether receptors contained in the polymer chain.

The turbidity oscillations of self-oscillating polymers in the Belousov-Zhabotinsky (BZ) reaction system depending on the crown ether receptors contained in the polymer network have been studied. The three monomers are copolymerized, namely, N-isopropylacrylamide, the metal catalyst monomer for the BZ reaction, and the crown ether receptor monomer, to prepare the self-oscillating polymers used in this study. The turbidity oscillations are characterized by monitoring the transmittance of the polymer solution in the BZ reaction system at a specific wavelength of 570 nm. The oscillations are varied by crown ether receptors used in the polymerization process, i.e., BCAm(6) or BCAm(5), for the selective recognition of specific cations between potassium and sodium ions in the solution. The selective recognition of the BCAm receptors in the polymer chain for the two ions has brought out a variation in the turbidity oscillations by a change in the hydrophilicity of the polymer chain. The oscillations of the polymer solution composed of the BCAm(5) receptor are more influenced by sodium ion, while the polymer solution of BCAm(6) receptor is affected by potassium ion. However, the oscillation patterns of the redox changes obtained by these solution systems look much alike despite the differences in the polymer chain by crown ether receptors and cations of bromate used for the BZ reaction.

Crown Ethers↗

Semi-interpenetrating polymer networks composed of biocompatible phospholipid polymer and segmented polyurethane.

2-Methacryloyloxyethyl phosphorylcholine (MPC) polymers, which have excellent biocompatibility, have been receiving increasing attention in biomedical and bioengineering fields; however, the mechanical strength of the hydrated MPC polymers is not sufficient for use in these fields as a bulk material. Therefore, we hypothesized that a novel material might be realized by reinforcing the MPC polymer network with segmented polyurethane (SPU). Semi-interpenetrating polymer networks (IPNs) composed of crosslinked MPC polymer and SPU were prepared. The mechanical properties of the IPN membrane were significantly improved compared with those of the MPC polymer membrane. Three-dimensional polymer networks of the MPC polymer in the IPNs were observed after solvent extraction of SPU. An X-ray photoelectron spectrum analysis revealed that the MPC units were exposed on the IPN surface. When the IPN was alternately soaked in water and ethanol, the swelling ratio was found to be completely reversible and no disintegration of the network structure was observed. The permeation coefficient of 1, 4-di(2-hydroxyethoxy)benzene through the IPN membrane was 1.11 x 10(-7) cm(-2)s(-1). The amount of adsorbed protein and the number of adherent platelets on the IPN membrane were effectively reduced compared with those on SPU. We concluded that IPNs composed of the MPC polymer and SPU are a new bulk biomaterial, which possesses both blood compatibility and good mechanical properties.

Absorption↗

Molecular dynamics modeling of polymer crystallization; from simple polymers to helical ones.

Crystallization of helical polymers is a very big challenge for molecular simulation. It involves many significant issues, such as folding in biomolecules and molecular recognition during crystal growth. Though direct molecular simulations of the process still involve very difficult problems, we here report our recent efforts toward better understanding of the crystallization in helical polymers. We begin with a brief review of our former studies on simple polyethylene-like polymers, and then we introduce several helical polymer models which are systematically made more complicated. We have already reported that a simple polyethylene-like polymer crystallizes very fast into chain folded lamellae from the melt. A slight modification of this simple polymer model by introducing proper bond angle and dihedral angle potentials gives one of the present models of the helical polymer. This helical polymer model is devised to be relatively rigid but mobile, to show easy helix-reversals, and to have a definite preference for gauche bonds. We find that this highly mobile helical polymer shows quick chain folded crystallization and forms approximate 4/1 helical structure. The intra- and the intermolecular order grow quite simultaneously suggesting highly cooperative nature of the phenomena. Further elaboration of the helical model, giving pendant side groups and higher energy barrier to the helix reversals, leads us to a realistic united atom model of iPP. The conventional and the multi-canonical Monte Carlo simulations are applied to find probable modes of chain folding and the ground state conformations. Though a very short chain readily forms a regular 3/1 helix of alternating trans and gauche bonds, much longer chains of 30- and 50-propylene units are not found to have energetic ground states in the regularly folded conformations.

Journal Article↗

Modulation of the surface architecture of gram-negative bacteria by the action of surface polymer:lipid A-core ligase and by determinants of polymer chain length.

Lipopolysaccharides (LPSs) are complex glycolipids found in the outer membrane of Gram-negative bacteria. The lipid A-core component of the LPS molecule provides a versatile anchor to which a surface polymer:lipid A-core ligase enzyme can attach one or more structurally distinct surface polymers in a single bacterial strain. In some cases the same polymer can be found on the cell surface in both lipid A-core-linked and -unlinked forms. Analysis by SDS-PAGE of populations of LPS molecules extracted from bacterial cells indicates that there is extensive heterogeneity in their size distribution. Much of the heterogeneity results from complex modal distributions in the chain length of the polymers which are attached to lipid A-core. This is the result of preferential ligation of polymers with specific degrees of polymerization during the assembly of the LPS molecule. The surface architecture of the Gram-negative bacterial cell is therefore profoundly affected by the activities of the surface polymer:lipid A-core ligase and by molecular determinants of polymer chain length. Because of the involvement of cell-surface polymers in interactions between pathogenic bacteria and their hosts, these enzymatic activities also have an important impact on virulence. In this review, the organization of LPSs and related surface polymers will be described and the current understanding of the molecular mechanisms involved in surface diversity will be discussed. Emphasis is placed on the Enterobacteriaceae, but similarities to other bacteria suggest that aspects of the enterobacterial system will have broader significance.

ATP-Binding Cassette Transporters↗

The interaction of plasma proteins with polymers. I. Relationship between polymer surface energy and protein adsorption/desorption.

Adsorption of bovine albumin, gamma-globulin and fibrinogen from phosphate buffer solution (pH = 7.5) onto several polymer films was studied using the radioiodinated proteins (125I). The kinetics of desorption of the proteinated polymer films in bovine plasma was determined. Contact angle measurements on these same polymers allowed the calculation of dispersive (WA d) and polar (Ip) components of the polymer-protein solution system. Results from these measurements show that the nondispersive-dispersive force balance at the polymer-protein solution interface, expressed by the Ip/WA d ratio, is an important factor for binding of proteins on polymer surfaces. The purity of fibrinogen and the cleaning procedures for the polymer surfaces influence the absolute values of proteins adsorbed on polymer surfaces.

Adsorption↗

Thermo and pH responsive polymers as gene delivery vectors: effect of polymer architecture on DNA complexation in vitro.

Poly(N-isopropylacrylamide) (PNIPAm) co-polymers responsive to temperature and pH were prepared with side chain chemistries in order to exhibit phase transitions under physiologically relevant conditions. Fluorescence spectroscopy, gel retardation assays, dynamic light scattering and atomic force microscopy were used to characterize the binding of plasmid DNA to these materials and to control polymers poly(ethyleneimine) (PEI) and poly(ethyleneimine)-octanamide. Complexes of plasmid DNA with thermoresponsive cationic polymers containing PNIPAm displayed variations in gel retardation behaviour above and below polymer phase transition temperatures, with a high molecular weight linear cationic PNIPAm co-polymer forming complexes with reduced affinity above LCST whereas a branched PEI-PNIPAm co-polymer bound with higher affinity above the PNIPAm phase transition. The thermoresponsive polymers also exhibited changes in particle morphology across the same temperature ranges with polymer DNA complexes prepared at N/P ratios of 2:1 generating spherical particles varying in radius between 30-70 nm at 25 degrees C and 60-100 nm at 40-45 degrees C. The transport of DNA within these complexes to cell nuclei was demonstrated to occur within 24 h in tissue culture via confocal microscopy, and low level transfection of mouse muscle cells by a reporter gene encoding green fluorescent protein was achieved with the branched thermoresponsive PEI-PNIPAm conjugate.

Animals↗

Characterization of chitosan hydrochloride--mucin rheological interaction: influence of polymer concentration and polymer:mucin weight ratio.

The aim of the present work was to investigate the influence of polymer concentration and polymer:mucin weight ratio on chitosan--mucin interaction, assessed by means of viscosimetric measurements. Two hydration media, distilled water and 0.1 M HCl, were used. Chitosan solutions were prepared at concentrations greater than the characteristic entanglement concentration and mixed with increasing amounts of porcine gastric mucin. Viscosity measurements were performed on the polymer--mucin mixtures and on polymer and mucin solutions having the same concentrations as in the mixtures. The flow curves were fitted according to a modified form of Cheng--Evans equation in order to obtain the relevant model parameters: low shear viscosity eta(0) and high shear viscosity eta(infinity), indexes of the sample structure at rest and upon high shear, respectively. The formation of chitosan--mucin interaction products was determined on the basis of the changes in eta(0) and eta(infinity) of the mixtures as a function of polymer:mucin weight ratio. Rheological synergism parameter was also calculated. The results obtained suggest that two different types of rheological interaction occur between chitosan and mucin in both media, depending on polymer concentration and polymer:mucin weight ratio: one is characterized by a minimum in viscosity and occurs at higher polymer:mucin weight ratio, the other one produces a positive rheological synergism and is observed in presence of an excess of mucin. Only the last one causes a 'strengthening' of the mucoadhesive interface and it is responsible for the mucoadhesive joint. This hypothesis is confirmed by tensile stress measurements performed on HCS solutions in presence of mucin dispersions at different concentrations.

Animals↗