Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Platelet Function Tests”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Matching the evaluation of the clinical efficacy of clopidogrel to platelet function tests relevant to the biological properties of the drug.

OBJECTIVES: This study aimed to explore platelet function tests relevant to the biological effects of clopidogrel that could help the clinical monitoring of drug efficacy. BACKGROUND: Clopidogrel selectively inhibits the P2Y12 receptor, the major role of which is stabilization of aggregation, whereas initiation of aggregation depends on activity of both P2Y1 and P2Y12 receptors. METHODS: Tests used were peak aggregation (Agg(max)) and late aggregation (Agg(6min)), and disaggregation, relating to P2Y1 and P2Y12 activity, respectively; and monoclonal antibody binding activated glycoprotein (GP) IIb/IIIa receptors (PAC-1) and P-selectin, measuring activation and secretion. A first study compared hirudin/PPACK (r-hirudin and D-phenylalanyl-prolyl-arginine chloromethyl ketone) with citrate as blood anticoagulant (16 patients), and a second control study compared the effects of clopidogrel, aspirin, or both (20 normal controls). RESULTS: Clopidogrel similarly inhibited adenosine 5'-diphosphate (ADP)-induced Agg(max) with either anticoagulant, but significantly more Agg(6min) (75% vs. 31%), P-selectin (72% vs. 53%), and PAC-1 (62% vs. 24%) in hirudin/PPACK. In the control study, it inhibited Agg(max) by 22%, and Agg(6min), P-selectin, and PAC-1, by 69%, 66%, and 55%, respectively (all p < 0.05). Disaggregation at six min reached 62% with clopidogrel, but was virtually absent with placebo and aspirin. Non-responsiveness as evaluated by inhibition of Agg(max) in citrate was diagnosed in 35% of patients; in half this rate by Agg(6min), P-selectin, and PAC-1; and in 6% to 12% with the latter tests performed in hirudin/PPACK. CONCLUSIONS: The evaluation of clopidogrel responsiveness by platelet function tests is largely influenced by the choice of blood preservative and functional tests. Measures of aggregation stabilization, and of consequent secretion and activation, identified most patients as responders, contrasting with measures of peak aggregation, by likely reflecting better the interactions clopidogrel and the P2Y12 receptor.

Aged↗

Platelet activation markers in patients with peripheral arterial disease--a prospective comparison of different platelet function tests.

Peripheral vascular disease (PVD) is an indicator of diffuse atherosclerosis and is associated with a greatly increased incidence of coronary heart and cerebrovascular disease. Although several studies have assessed whether in vivo platelet activation takes place in patients with PVD, no data are available comparing different platelet function tests in this patient population. We have compared prospectively four tests for the measurement of in vivo platelet activation (plasma betaTG, plasma PF4, intraplatelet betaTG and urinary excretion of 11-dehydro-TXB2) and one in vitro platelet function test (ADP-induced platelet aggregation) in 63 well-characterized patients with intermittent claudication and in 18 age- and sex-matched healthy volunteers. No statistically significant difference was found between patients and controls for plasma betaTG (20.0 +/- 11.8 vs. 18.8 +/- 9.0 ng/ml, respectively), plasma PF4 (5.2 +/- 2.9 vs. 6.3 +/- 3.5 ng/ml), betaTG/PF4 ratio (4.0 +/- 2.9 vs. 3.6 +/- 1.8), intraplatelet betaTG (4503 +/- 1482 vs. 4059 +/- 1065 ng/ml), and threshold aggregatory concentration of ADP (1.7 +/- 0.72 vs. 1.45 +/- 0.56 microM). Urinary 11-dehydro-TXB2 was instead significantly higher in the PVD group (55.4 +/- 27.5 vs. 26.7 +/- 7.0 ng/h, p <0.001). Our study shows that urinary 11-dehydro-TXB2 is a more sensitive index of in vivo platelet activation than the measurement of either platelet specific proteins or of in vitro platelet aggregation in patients with PVD.

Adenosine Diphosphate↗

Platelet function testing: an improved approach utilizing lumi-aggregation and an interactive computer system.

An approach to laboratory testing of platelet function is described that uses an interactive, computer-assisted lumi-aggregation technic. Use of this approach over the past 18 months in the clinical laboratory has improved significantly not only the procurement but also the analysis of aggregation and secretion data. All calculations are printed out automatically following the completion of each run, permitting an entire study to be completed in 60-90 minutes following the preparation of platelet-rich plasma. An internal ATP standard used in each run helps minimize apparent variations in platelet ATP secretion resulting from variations in the luciferin-luciferase measuring system itself. The simultaneous monitoring of platelet aggregation and secretion provides a much-improved opportunity for the assessment of secretory defects than does study of aggregation curves alone. The present work provides a simple, efficient approach to platelet lumi-aggregation testing in the clinical laboratory.

Blood Platelets↗

Platelet function testing in the pony.

Platelet isolation techniques and platelet function were evaluated in 35 adult ponies. Platelet recovery from whole blood was consistent and the preparation of platelet rich plasma was facilitated by an enhanced erythrocyte sedimentation rate. All platelet samples aggregated in response to 10 microM ADP. However, concentrations of ADP as high as 100 microM did not elicit significant 14C-serotonin release. Collagen induced irreversible platelet aggregation and 14C-serotonin release in all samples. The threshold dose for collagen in most ponies was 1.5 micrograms. Arachidonic acid (500 microM) failed to induce irreversible platelet aggregation or 14C-serotonin release in any of the samples evaluated. Pony platelets were nonresponsive to epinephrine (5.5 microM).

Adenosine Diphosphate↗

Platelet function tests during major operation for gastro-intestinal carcinoma.

Platelet function tests were performed on 15 patients undergoing major operation preoperatively, during anaesthesia and 30 minutes and 3 hours after the beginning of operation. It was found that during anaesthesia platelet retention in a glass bead column and platelet aggregation were slightly reduced. During operation the bleeding time and the delay period of the collagen-induced aggregation were progressively prolonged, and the aggregation induced by ADP at a final concentration of 1 and 2 micrometer and by adrenaline was progressively reduced.

Adult↗

Platelet function testing in apheresis products: flow cytometric, resonance thrombographic (RTG) and rotational thrombelastographic (roTEG) analyses.

During storage of platelet concentrates, quality control of the units is mandatory. This includes the important testing of the hemostatic function of platelets. So far, mostly platelet aggregation analyses have been performed. In this study, new approaches were tested to evaluate the applicability of modern techniques for quality monitoring. Plateletpheresis was performed with two different cell separators (AMICUS cell separator, Fenwal, Baxter Healthcare, Deerfield, USA; COBE Spectra, COBE BCT, Lakewood, USA). In each procedure split products (n = 22) were prepared and stored for 1-2 days (n = 22) or 3 5 days (n = 22). Platelet hemostatic capacity was tested by applying flow cytometry. platelet aggregation (platelet-rich-plasma [PRP]+agonist), resonance thrombography (RTG; PRP, no agonist) and rotational thrombelastography (roTEG; PRP+agonist). Flow cytometric analyses did not reveal significant changes in structural (CD41a. CD42b) or activation-dependent antigens (CD62p, CD63, LIBS, RIBS). Also, differences in the data from the flow cytometric reactivity tests were not significant between the two groups. In platelet aggregation assays, shape change (p = 0.8), maximum aggregation (p = 0.4), and maximum gradient (p = 0.8) did not show significant differences between the two groups. In the RTG test, differences between r-time (reaction time; p = 0.4), and f-time (clot formation time [fibrin influence]; p = 0.3), and in roTEG r-time (coagulation time; p = 0.1) and k-time (clot formation time; p = 1.0) were not significant. P-time (clot formation time [platelet influence]) and M (maximum amplitude) in RTG, and k-time and MA (maximum amplitude) in roTEG showed a slight decrease in platelet function (p < or = 0.05). We conclude that platelet function is well maintained during storage. This is reflected by the results of immunological and platelet function assays. Rotational thrombelastography (in the case of PRP) and especially resonance thrombography represent promising methods for quality control of platelet concentrates and rapidly provide information about the status of platelet function and the whole clotting process.

Blood Coagulation Tests↗

Platelet function tests predict bleeding and thrombotic events after off-pump coronary bypass grafting.

OBJECTIVE: A balanced coagulation system after cardiac surgery minimizes bleeding and thrombotic events. However, the best method to monitor this balance has not been established. We used a series of tests of coagulation and platelet function to define the risk of bleeding and thrombotic events after OPCAB. METHODS: In 76 patients, routine coagulation tests (i.e. prothrombin time, fibrinogen level, d-dimer, and platelet count), thrombelastography, and whole blood aggregometry were obtained perioperatively and on days 1 and 3 after OPCAB. Intra- and postoperative blood loss was determined. Early patency of venous bypass grafts was determined using CT angiography (Philips Medical, Corp.). RESULTS: Chest tube output and red cell volume loss at 24 h were 952+/-475 and 190+/-115 ml, respectively. Early graft failure developed in eight patients. Perioperative changes in routine coagulation tests showed no correlation with either bleeding or thrombosis. However, perioperative decline in platelet function as assessed by the area under the impedance curve for whole blood aggregometry correlated with intraoperative blood loss (R=0.42, P<0.05). A perioperative decline in the maximum amplitude of the thrombelastography trace showed a significant correlation with 24h hemoglobin loss (R=0.45, P<0.05). Compared to those with all patent grafts, patients with early graft failure demonstrated a reduction in platelet sensitivity to aspirin by both thrombelastography and aggregometry on day 3. CONCLUSIONS: In contrast to standard coagulation testing, platelet function predicted both bleeding and thrombosis after OPCAB. Titration of perioperative platelet function according to these tests may minimize thrombosis without increasing bleeding.

Aged↗

Platelet function tests in thalassemic children.

Platelet changes in thalassemia included prolongation of bleeding time (30%), thrombocytosis (29%), decreased platelet retention (79%), and normal PF3 release. Platelet aggregation was found to be hyperaggregation in 50%, normal in 22%, and hypoaggregation in 28% of the studied patients. Platelet changes in thalassemia can be hyper-, normal, or hypofunction. The changes are likely to be related to many factors, particularly to the progress of the disease. Platelet hypoaggregation may lead to a bleeding problem. Platelet hyperaggregation and thrombocytosis were prominent in the splenectomized patients and/or the severely anemic group; antiplatelet drugs may be indicated in these patients.

Adolescent↗

Maternal selective serotonin reuptake inhibitor intake does not seem to affect neonatal platelet function tests.

Recently, concerns have been raised regarding the potential impairment of neonatal platelet function and the potential risk of bleeding in neonates born to mothers treated with selective serotonin reuptake inhibitors (SSRI). Our aim was to test whether the platelet function of neonates born to SSRI-treated mothers was impaired when compared to non-SSRI-exposed neonates. In a single-center prospective study, platelet function was evaluated using a cone and platelet analyzer (CPA) device and compared between mother-infant pairs as well as normal non-SSRI-exposed infants. Twenty-seven SSRI-exposed and 27 non-SSRI-exposed full-term neonates and their 23 mothers were tested. No correlation was found between SSRI exposure among either neonates or mothers and parameters of surface coverage (SC) and average size (AS), manifesting platelet function as tested by CPA. SC was similar among SSRI-exposed babies as compared to those in the control group, whereas the size of platelet aggregates (AS) was higher among controls. Neither maternal diseases nor SSRI intake were associated with impaired platelet function and lower SC values, nor were any perinatal conditions. None of the babies suffered from bleeding. We conclude that maternal SSRI therapy does not impair whole-blood CPA-tested platelet function of healthy full-term neonates.

Adult↗

Variability in platelet responses to collagen--comparison between whole blood perfusions, traditional platelet function tests and PFA-100.

The purpose of this study was to determine if the results obtained in platelet function tests and whole blood perfusions are associated with those in platelet function analyser (PFA)-100. We used collagen type I monomers and fibrils to analyse the distinct roles of glycoprotein (GP) Ia/IIa and other collagen receptors in flowing blood under a high shear rate (1600/s) and in aggregation studies. Also, anticoagulation [citrate vs. D-phenylalanyl-1-prolyl-1 arginine chloromethyl ketone (PPACK)] was varied to enhance the functions of GP Ia/IIa, since it has been shown that the cation-poor environment of citrated blood impairs GP Ia/IIa-dependent platelet recruitment. Large interindividual variability (45-fold) was detected in deposition of platelets in whole blood perfusions over collagen monomers, whereas this variation was only fourfold in fibrils. In PFA, this variation was reduced to 2.5-fold. However, platelet deposition on monomers is associated with epinephrine-enhanced PFA (r=-.49, P<.03), whereas platelet deposition on fibrils is correlated with adenosine diphosphate (ADP)-enhanced PFA (r=-.47, P<.05), suggesting a distinct synergism between epinephrine and monomers (GP Ia/IIa) as well as ADP with fibrils (other collagen receptors). Donors with 807 C/C polymorphism of GP Ia (n=14) had longer lag phase in aggregation experiments compared with C/T (n=7) both by monomers and fibrils (P<.04), but these polymorphisms with their mild impact on GP Ia/IIa activity did not markedly differ in other tests. In conclusion, the results obtained in perfusion studies and PFA experiments correlated, but PFA fails to reveal the large-scale variability related to collagen-induced platelet responses.

Adenosine Diphosphate↗

Platelet function test HemoSTATUS 2: tool or toy for an optimized management of hemostasis?

BACKGROUND: Bleeding after open heart surgery is a common but unintended problem, which is unequivocally related to platelet function. The target of our study was to correlate platelet activation levels and postoperative blood loss as well as the predictive power of measurements focusing on postoperative hemostasis. MATERIALS AND METHODS: The prospective trial comprised 100 patients (mean age: 64.3 years, 68% male) undergoing cardiac surgery. Platelet activation was measured by the new and modified HemoSTATUS test. Blood samples were drawn pre-, intra- and postoperatively. Standard hemostasis tests, including activated clotting time (ACT), partial thromboplastin time (PTT), hemoglobin, platelet count, antithrombin III (AT III) and fibrinogen, were measured according to the clinical routine. Blood loss and consumed blood products were documented up to the 24th hour after the operation. RESULTS: Platelet activation showed a typical change, with lowest levels after the end of extracorporeal circulation and a restitution to preoperative levels after 24 h. Mean blood loss was 461 ml. Statistical analysis showed neither a correlation to the platelet activation measurements nor to low pre-, intra- or postoperative levels. CONCLUSION: The HemoSTATUS platelet function test is not suitable for a reliable monitoring of platelet pathophysiology and patient outcome after extracorporeal circulation. Furthermore, no correlation of preoperative platelet activation and blood loss could be shown.

Aged↗

Can platelet function tests predict the clinical efficacy of aspirin?

"Aspirin resistance" and "aspirin nonresponsiveness" are terms used both to describe both the failure of aspirin to protect subgroups of individuals from severe vascular events and to evoke an appropriate inhibition of platelet function. Several studies utilizing a broad range of platelet function tests have shown that some subgroups of individuals exhibit a reduced or completely missing antiplatelet response to aspirin. The clinical significance of aspirin nonresponsiveness for the prediction of clinical endpoints remains, however, to be determined. Thus far, only three prospective clinical trials have demonstrated a possible relationship between aspirin nonresponsiveness and subsequent vascular events. Most platelet function tests used in respective clinical studies cannot be reliably performed in clinical routine and are not interchangeable for monitoring antiplatelet treatment. There is a need for a simple and reliable assay for predicting the clinical efficacy of antiplatelet therapy. Recent data demonstrate that none of the currently developed assays, including the PFA-100 system, are presently able to accomplish these objectives.

Adenosine Diphosphate↗

Effect of a diet of polyunsaturated fats on some platelet-function tests.

The fat in the normal diet of 19 apparently well men was partly replaced by linoleic acid. This produced striking changes in many platelet-function tests, suggesting decreased platelet activation. Twenty controls maintaining their normal diet showed no change. It is concluded that normal people have a degree of platelet activation which can be decreased. This may be relevant to the benefits attributed to a diet containing polyunsaturated fats.

Adult↗

The antithrombotic effect of thromboxane receptor antagonist HN 11500 on thrombus formation in laser thrombosis model and platelet function tests.

The effect of thromboxane receptor antagonist HN 11500 (Chemie Linz AG, Austria) on thrombus formation in laser thrombosis model and platelet function test has been studied. In this study HN 11500 was a potent antithrombotic agent significantly inhibiting thrombus formation in venules in doses higher than 5 mg/kg after i.v. and 10 mg/kg after oral administration. Lower doses were needed to obtain the same antithrombotic effect when arterioles were investigated. The antithrombotic effect of minimal effective doses of HN 11500 lasted longer than 8 hours in venules and more than 12 hours in arterioles. After oral feeding of this thromboxane receptor antagonist in doses 5 mg/kg, antithrombotic effect in investigated arterioles lasted longer than 16 hours but less than 20 hours. When different doses of HN 11500 were injected i.v. together with r-Hirudin or LMWH CY 216 the inhibitory effect on thrombus formation in venules was stronger and observed with lower doses of HN 11500. In vitro study HN 11500 inhibited platelet adhesion to the siliconized glass, bovine extracellular matrix as well as ADP and collagen mediated platelet aggregation. Lower concentration of this agent were needed to inhibited platelet adhesion to the extracellular matrix than platelet adhesion to the siliconised glass, and ADP and collagen induced aggregation.

Animals↗

Screening for aspirin responsiveness after transient ischemic attack and stroke: comparison of 2 point-of-care platelet function tests with optical aggregometry.

BACKGROUND AND PURPOSE: Recent studies suggest that patients who do not respond to aspirin (ASA) therapy may be at increased risk of ischemic vascular events. The availability of simple to use point-of-care (POC) platelet function tests now potentially allows aspirin nonresponsiveness to be identified in routine clinical practice. However, there are very few data on whether the different tests produce consistent results. We therefore compared 2 POC tests (PFA-100 device and the Ultegra-RPFA [RPFA]) with conventional light transmission aggregometry (LTA). METHODS: Platelet function was assessed by all 3 tests in 100 patients receiving low-dose ASA therapy after transient ischemic attack (TIA) or ischemic stroke. RESULTS: The incidence of ASA nonresponsiveness was 17% by the RPFA and 22% by the PFA-100, compared with only 5% by LTA (ie, as defined with both arachidonic acid and ADP). Agreement between the RPFA and the PFA-100 and arachidonic acid induced LTA was poor (kappa=0.16, 95% CI, -0.08 to 0.39, P=0.11; and kappa=0.09 -0.12 to 0.30, P=0.32, respectively). Agreement between the 2 POC tests was also poor (kappa=0.14, -0.08 to 0.36, P=0.15). Only 2% of patients were aspirin nonresponders by all 3 tests. CONCLUSIONS: The prevalence of apparent ASA nonresponsiveness was higher with both the POC tests than with LTA. However, agreement between the tests was poor and very few patients were ASA nonresponsive by all 3 tests. Aspirin nonresponsiveness is therefore highly test-specific and large prospective studies will be required to determine the prognostic value of each of the separate tests.

Adult↗

A new platelet function test.

A method for screening EDTA(K3) blood samples for platelet function is described. The general availability of whole blood platelet counters in the clinical laboratory suggested their use to measure platelet aggregation. To simplify the collection and storage of blood samples, a method utilizing EDTA collected blood is described. Addition of calcium and citrate restores platelet function to blood samples even when stored at room temperature for several hours. Thus, the blood sample used to assay RBC, WBC and platelet parameters may also be employed in platelet aggregation. A comparison of this method with aggregometry on 120 subjects indicated a similar response to arachidonate, collagen, ristocetin and ADP.

Adenosine Diphosphate↗