Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Photons”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Cortical photons in early development of frog eggs: comparative study of photon emission between nuclear division and cytoplasmic fission.

In the study of cell division in the early development of frog eggs, cortical photon emission was investigated by converting small light emission from living cells into digital pulses of potentials and recording the integrals of these pulses (analog method), counting the number of pulses (photon-counting method), and counting the number of integrated pulses (improved photon-counting method). By the analog and improved photon-counting methods, changes in photon emission due to cell division could be clearly detected. The emitted light increased about 5.10(-19)W at the start of a cleavage furrow. Rapid changes in chemical reactions causing photon emission were compared during nuclear division and cytoplasmic phases. This emission occurred mainly in cytoplasmic fission, the rate being greater than in nuclear division by a factor of about 2.9. Chemical reaction rates were shown to differ according to bulk emission, thus indicating the mechanisms for the reactions to also differ.

Animals↗

Tunable photonic band gaps in two-dimensional photonic crystals by temporal modulation based on the Pockels effect.

We theoretically demonstrate the tuning of photonic band gaps in two-dimensional photonic crystals composed of rods by temporal modulation based on the Pockels effect. Refractive indices of rods can be changed periodically by applied alternating voltage under the influence of the Pockels effect, which causes new photonic band states other than original ones. Therefore, photonic band gaps can be closed by the new photonic band states, which may provide novel applications for tunable photonic crystals.

Journal Article↗

Opening up complete photonic bandgaps in three-dimensional photonic crystals consisting of biaxial dielectric spheres.

In this paper, the scattering matrix of sphere with dielectric biaxial anisotropy is obtained exactly within the framework of the extended Mie theory. By incorporating the scattering matrix into the multiple scattering method, we study theoretically the photonic band structure of three dimensional photonic crystals consisting of biaxial dielectric spheres. Our results demonstrate that complete photonic bandgaps can be found in both fcc and sc lattice structures, which are absent in photonic crystals composed of isotropic dielectric spheres. Moreover we have compared our results with those coming from the photonic crystals consisting of the uniaxially birefringent dielectric spheres. It is found that because of the enhancement of the anisotropy, the degeneracy is lifted further, resulting in two neighboring photonic bandgaps, the lower one is complete while the upper one is partial existing only in some special regions of the first Brillouin zone.

Journal Article↗

Unwanted photon and neutron radiation resulting from collimated photon beams interacting with the body of radiotherapy patients.

Monte Carlo calculations have been made to determine the energies delivered by photons and neutrons to the human body irradiated by collimated photon beams. The beams were monoenergetic and ranged from 100 keV to 40 MeV. The energy deposition in the body was sorted into two regions: inside and outside the irradiated volume. Most of the results obtained were for a beam size of 100 cm2 although some calculations were also made to 600 cm2 beams. The effect of beam size on energy deposition in the two regions was investigated for 60Co gamma rays. Graphs are presented which give the integral doses delivered by neutrons and photons to the two regions for therapy beams of various energies. These graphs can be used to calculate the integral doses which are delivered inside and outside the treatment volume for photon spectra from most medical accelerators. Calculations of energy deposition were also made for the spectra from two particular accelerators. These were done using Monte Carlo as well as by simply "folding" the spectra into the results for monoenergetic photons. The results obtained by both methods were in good agreement and indicated that the integral doses deposited outside the treatment volume by neutrons are more than two orders of magnitude smaller than those deposited by scattered photons.

Cobalt Radioisotopes↗

[Two-photon excitation fluorescence spectrum of the light-harvesting complex LH2 from Chromatium minutissimum within 650-745 nm range is determined by two-photon absorption of bacteriochlorophyll rather than of carotenoids].

Two-photon fluorescence excitation spectra of the peripheral light-harvesting complex LH2 from the purple photosynthetic bacterium Chromatium minutissimum were examined within the expected spectral range of the optically forbidden S1 singlet state of carotenoids. LH2 preparations isolated from wild-type and carotenoid-depleted cells were used. 100-fs laser pulses in the range of 1300-1490 nm with an energy of 7-9 mW (corresponding to one-photon absorption between 650 and 745 nm) were used for two-photon fluorescence excitation. It was shown that two-photon fluorescence excitation spectra of LH2 complex from wild and carotenoid-depleted cells are very similar to each other and to the two-photon fluorescence excitation spectrum of bacteriochlorophyll a in acetone. It was concluded that direct two-photon excitation of bacteriochlorophyll a determines the fluorescence of both samples within the 650-745 nm spectral range.

Bacteriochlorophylls↗

Photon-burst analysis in two-photon fluorescence excitation flow cytometry.

We studied the use of a dramatically reduced testing zone in combination with two-photon excitation and photon-burst analysis in high-throughput rare-event detection simulation using a modified flow cytometer. Two-photon excitation measurements were performed with a mode-locked titanium:sapphire laser. Fluorescence emission was measured with a photon-counting avalanche photodiode. Measured signal was analysed offline by autocorrelation and burst detection methods. Test samples were composed of full blood and orange fluorescent polystyrene nanospheres mixed in full blood. Results show that two-photon fluorescence excitation and time-correlation analysis provide a good signal-to-noise ratio for rare-event particle detection in a turbid sample environment.

Algorithms↗

Effect of bin time on the photon counting histogram for one-photon excitation.

We have demonstrated that our photon counting histogram (PCH) model with the correction for one-photon excitation is valid at multiple bin times. The fitted apparent brightness and concentration follow the three-dimensional diffusion model. More importantly, the semi-empirical parameter, F, introduced in the PCH model for one-photon excitation to correct for the non-Gaussian shape of the observation volume, shows small variations with different bin times. These variations are consistent with the physical interpretation of F, and they do not affect the resolving power of the PCH model for one-photon excitation. Based on these findings, we extend the time-independent PCH analysis to time-dependent photon counting multiple histograms (PCMH). This model considers the effect of bin time on the PCH parameters in a way that is similar to fluorescence intensity multiple distribution analysis (FIMDA). From the same set of data, PCMH extracts time-dependent parameters (diffusion time and triplet-state relaxation time) as well as time-independent parameters (true specific brightness and true average number of molecules). Given a three- to fourfold experimental difference in molecular brightness, we find that PCMH can resolve each species in a two-species sample and extract their respective diffusion times even when fluorescence correlation spectroscopy cannot.

Algorithms↗

Two-dimensional photon counting imaging and spatiotemporal characterization of ultraweak photon emission from a rat's brain in vivo.

The process of metabolic reactions within living cells leads to spontaneous ultraweak light emission. The development of a system for highly sensitive imaging and spatiotemporal analysis of ultraweak photon emission from a rat's brain is reported in this paper. The equipment used in this experiment consists of a two-dimensional photon-counting tube with a photocathode measuring 40 mm in diameter, a highly efficient lens system, and an electronic device to record time series of a photoelectron train with spatial information. The sensitivity and ability to extract spatiotemporal information from sequential data of a single photoelectron train were examined. The minimum detectable radiant flux density of the system was experimentally estimated to be 9.9 x 10(-17) W/cm2 with a 1-s observation time. Spontaneous photon emission was demonstrated from an exposed rat's cortex in vivo without adding any chemical agent or employing external excitation. An image of ultraweak photon emission was compared with one obtained after cardiac arrest. The intensity after cardiac arrest was depressed to approximately 60% of before that. The regional properties of time courses of emission intensity were also demonstrated, indicating the potential usefulness for spatiotemporal characterization of photon emission with mapping of physiological information such as oxidative stress. This technology constitutes a novel method, with the potential to extract pathophysiological information from the central nervous system.

Animals↗

Photon-by-photon determination of emission bursts from diffusing single chromophores.

One of the difficulties in diffusion-type single-molecule experiments is the determination of signal amid photon-counting noise. A commonly used approach is to further average the noisy time trace by binning, followed by placing a threshold to discriminate signal from background. The choice of smoothing parameters and the placement of the threshold may impact on the efficiency with which the information-rich region can be harvested, among other potential complications. Here we introduce a procedure that operates on the data sequence photon by photon, thereby relieving the incertitude in choosing binning-thresholding parameters. We characterize this procedure by detecting the two-photon emission bursts from diffusing single gold nanoparticles. The results support our burst-finding procedure as a reliable and efficient way of detecting and harvesting photon bursts from diffusing experiments.

Diffusion↗

Photon fluence perturbation correction factors for solid state detectors irradiated in kilovoltage photon beams.

Dose perturbation correction factors, gamma(p), for LiF, CaF2 and Li2B4O7 solid state detectors have been determined using the EGS4 Monte Carlo code. Each detector was simulated in the form of a disc of diameter 3.61 mm and thickness 1 mm irradiated in a clinical kilovoltage photon beam at a depth of 1 cm in a water phantom. The perturbation correction factor gamma(p) is defined as the deviation of the absorbed dose ratio from the average mass energy absorption coefficient ratio of water to the detector material, (mu(en)/rho)med,det, which is evaluated assuming that the photon fluence spectrum in the medium and in the detector material are identical. We define another mass energy absorption coefficient ratio, (kappa(en)/rho)med,det, which is evaluated using the actual photon fluence spectrum in the medium and detector for LiF and CaF2 rather than assuming they are identical. (kappa(en)/rho)med,det predicts the average absorbed dose ratio of the medium to the detector material within 0.3%. When the difference in atomic number between the cavity and the phantom material is large then their photon fluence spectra will differ substantially resulting in a difference between (kappa(en)/rho)med,det and (mu(en)/rho)med,det. The value of gamma(p) calculated using (mu(en)/rho)med,det is up to 27% greater than unity for a cavity of CaF2 in 50 kV x-rays. When the atomic number of the medium and detector are similar, their photon fluence spectra are similar, and the difference between (kappa(en)/rho)med,det and (mu(en)/rho)med,det is small. For instance their difference for LiF is less than 2%. The average mass energy absorption coefficient ratio, (mu(en)(E)/rho)w,LiF, evaluated using the mean or representative energy, E, is up to 8% different from (mu(en)/rho)w,LiF. For calcium fluoride the difference between (mu(en)/rho)w,CaF2 and (mu(en)(E)/rho)w,CaF2 is up to 42% in the energy range studied.

Models, Theoretical↗

Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators.

The current study presents the reference photon dosimetry data (RPDD) and reference phase space data (RPSD) for the 6 MV photon beam from Varian 2100 series linear accelerators. The RPDD provide the basic photon dosimetry data, typically collected during the initial commissioning of a new linear accelerator, including output factors, depth dose data, and beam profile data in air and in water. The RPSD provide the full phase space information, such as position, direction, and energy for each particle generated inside the head of any particular linear accelerator in question. The dosimetric characteristics if the 6 MV photon beam from the majority of the aforementioned accelerators, which are unaltered from the manufacturer's original specifications, can be fully described with these two data sets within a clinically acceptable uncertainty (approximately +/-2 %). The current study also presents a detailed procedure to establish the RPDD and RPSD using measured data and Monte Carlo calculations. The RPDD were constructed by compiling our own measured data and the average data based on the analysis of more than 50 sets of measured data from the Radiological Physics Center (RPC) and 10 sets of clinical dosimetry data obtained from 10 different institutions participating in the RPC's quality assurance monitoring program. All the measured data from the RPC and the RPC-monitored institutions were found to be within a statistically tight range (i.e., 1sigma approximately 1% or less) for each dosimetric quantity. The manufacturer's standard data, except for in-air off-axis factors that are available only from the current study, were compared with the RPDD, showing that the manufacturer's standard data could also be used as the RPDD for the photon beam studied in this study. The RPSD were obtained from Monte Carlo calculations using the BEAMnrc/ DOSXYZnrc code system with 6.2 MeV (a spread of 3% full width at half maximum) and 1.0 mm full width at half maximum as the values of the energy and radial spread of a Gaussian electron pencil beam incident on the target, respectively. The RPSD were capable of generating Monte Carlo data that agreed with the RPDD within the acceptance criteria adopted in the current study (e.g., 1% or 1 mm for depth dose). A complete set of the RPDD and RPSD from the current study is available from the RPC website (http://rpc.mdanderson.org) or via mass storage media such as DVD or CD-ROM upon request.

Electrons↗

Limiting Factors on Image Quality in Imaging through Turbid Media under Single-photon and Two-photon Excitation.

The effect of multiple scattering in a turbid medium on single-photon and two-photon fluorescence microscopy is experimentally investigated for different scattering characteristics including scattering anisotrophy and optical thickness of a turbid medium. It is demonstrated that two-photon excitation can provide significant improvement in penetration depth through turbid media, due to reduced scattering experienced by the excitation beam. It is also shown that the limiting factor in obtaining high-quality images under single-photon excitation is the fast degradation of image resolution caused by multiple scattering, while for two-photon excitation it is limited by the degradation of image contrast due to the reduction in fluorescence strength.

Journal Article↗

High-Q photonic nanocavity in a two-dimensional photonic crystal.

Photonic cavities that strongly confine light are finding applications in many areas of physics and engineering, including coherent electron-photon interactions, ultra-small filters, low-threshold lasers, photonic chips, nonlinear optics and quantum information processing. Critical for these applications is the realization of a cavity with both high quality factor, Q, and small modal volume, V. The ratio Q/V determines the strength of the various cavity interactions, and an ultra-small cavity enables large-scale integration and single-mode operation for a broad range of wavelengths. However, a high-Q cavity of optical wavelength size is difficult to fabricate, as radiation loss increases in inverse proportion to cavity size. With the exception of a few recent theoretical studies, definitive theories and experiments for creating high-Q nanocavities have not been extensively investigated. Here we use a silicon-based two-dimensional photonic-crystal slab to fabricate a nanocavity with Q = 45,000 and V = 7.0 x 10(-14) cm3; the value of Q/V is 10-100 times larger than in previous studies. Underlying this development is the realization that light should be confined gently in order to be confined strongly. Integration with other photonic elements is straightforward, and a large free spectral range of 100 nm has been demonstrated.

Journal Article↗

Resonance hyper-Raman excitation profiles of a donor-acceptor substituted distyrylbenzene: one-photon and two-photon states.

Resonance Raman and resonance hyper-Raman spectra of the "push-pull" conjugated molecule 1-(4'-dihexylaminostyryl)-4-(4"-nitrostyryl)benzene in acetone have been measured at excitation wavelengths from 485 to 356 nm (two-photon wavelengths for the nonlinear spectra), resonant with the first two bands in the linear absorption spectrum. The theory of resonance hyper-Raman scattering intensities is developed and simplified using assumptions appropriate for intramolecular charge-transfer transitions of large molecules in solution. The absorption spectrum and the Raman, hyper-Rayleigh, and hyper-Raman excitation profiles, all in absolute intensity units, are quantitatively simulated to probe the structures and the one- and two-photon transition strengths of the two lowest-energy allowed electronic transitions. All four spectroscopic observables are reasonably well reproduced with a single set of excited-state parameters. The two lowest-energy, one-photon allowed electronic transitions have fairly comparable one-photon and two-photon transition strengths, but the higher-energy transition is largely localized on the nitrophenyl group while the lower-energy transition is more delocalized.

Journal Article↗

Two-photon absorption strength: a new tool for the quantification of two-photon absorption.

In this paper, we define the two-photon absorption strength, a new characterization tool, similar to the oscillator strength, but for two-photon absorption. It allows the quantification of the two-photon absorption properties of molecular systems which are one-photon transparent. Its definition is such that the corresponding numerical values are around 100 for small molecules. We also show that this new theoretical tool allows the direct comparison of experimental and theoretical data without requiring the introduction of any arbitrary band width. As an example, the experimental and theoretical (AM1+CNDOS and HF+CIS3-21G) two-photon absorption properties of the 2,2'-bi(9,9-dihexylfluorene) molecule are compared.

Journal Article↗

The two-photon laser-induced fluorescence of the tumor-localizing photosensitizer hematoporphyrin derivative. Resonance-enhanced 750 nm two-photon excitation into the near-UV Soret band.

The tumor-localizing photosensitizer hematoporphyrin derivative (HPD) is shown to undergo a simultaneous two-photon excitation into the near-ultraviolet Soret band system upon intense laser irradiation at 750 nm, a spectral region where there is no significant HPD one-photon absorbance in aqueous solution. Subsequent to this excitation, internal conversion and vibrational relaxation occur, resulting in the population of the vibrationless level of the first electronically excited singlet state. This state relaxes by two channels, the emission of fluorescence in the spectral region 600-700 nm and intersystem crossing into the triplet manifold, followed by near-resonant electronic energy transfer with surrounding oxygen to result in the generation of highly reactive singlet molecular oxygen (1 delta g). Evidence for the two-photon excitation consists in the observation both of the HPD fluorescence spectrum in the region of 615 nm as a result of 750 nm excitation and the quadratic dependence of this fluorescence emission intensity upon the excitation laser intensity. Since, in general, the penetration depth of ultraviolet and visible light into tissue varies directly with wavelength (red penetrating more deeply than blue), these studies suggest the possibility that two-photon-induced localization of tumor-bound HPD might facilitate the detection of deeper lying tumors than allowed by the current one-photon photolocalization method.

Hematoporphyrins↗

Emission computer assisted tomography with single-photon and positron annihilation photon emitters.

Computed transverse section emission tomography using 99mTc with the Anger camera is compared to positron annihilation coincident detection using a ring of crystals and 68Ga. The single-photon system has a line spread function (LSF) of 9 mm full width at half maximum (FWHM) at the collimator and gives a transverse section reconstruction LSF of 11 mm FWHM with 144 views. The positron ring has a LSF of 6 mm at the center with a transverse section reconstruction LSF of 7.5 mm FWHM. Correction for uniformity of detector response and accurate center of rotation determination is essential in both techniques. The signal-to-noise ratio in a reconstruction is diminished by a factor of 1.2 x (number of resolution elements)1/4 over that expected from the average number of events per resolution element. Attenuation compensation causes more noise to appear in the center than the edge for both modes and an average increase in uncertainty of 30%. The effects of attenuation result in more loss of data for positron coincidence imaging than for single-photon imaging even at energies of 80 keV. For a 20-cm cylinder imaged in transverse section, only 20% of the positron annihilation events are not scattered; however, at 140 keV, 40% of the photons are not scattered. The relative crystal efficiency gives single-photon imaging an advantage of 5. On the other hand, the solid angle advantage of positron photon coincidence imaging is about 100 for the comparisons of this paper. Taking these factors into account, we find positron-computed section imaging has a tenfold increase in sensitivity over multiple-view imaging with the scintillation camera, which gives multiple sections but requires camera or patient rotation.

Elementary Particles↗

Observation of three-photon enhanced four-photon absorption.

We report the measurement of instantaneous resonant four-photon absorption in the polydiacetylene-PTS [polymer poly(bis para-toluene sulfonate) of 2,4-hexadyine-1,6 diol]. Although normally too weak to be observable, an exact degeneracy between three- and four-photon absorption into the dominant exciton and two-photon states, respectively, resonantly enhances this effect so that it can be measured (four-photon coefficient alpha(4)=0.01 cm(5)/GW(3)) at its peak wavelength of 1900 nm. Femtosecond measurements from 1200 to 2200 nm of two- and three-photon absorption, and the nonlinear refractive index coefficient are also reported.

Journal Article↗