Search PubMedSearch

SEARCH · Search PubMed

Results for “Pacemaker implantation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

58 records · Page 2Linked to original sources

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

An Overview of Red Breast Syndrome: A Qualitative Systematic Review of the Literature and a Single-Center Case Series.

Red breast syndrome (RBS) is an uncommon inflammatory complication that may occur following implant-based breast reconstruction and can clinically mimic surgical-site infection. This qualitative systematic review, based on comprehensive PubMed and Scopus searches, summarizes the existing literature on RBS, focusing on its etiology, clinical presentation, diagnostic characteristics, and therapeutic approaches following breast reconstruction using acellular dermal matrices (ADMs). A management protocol is proposed based on available data, and a single-center case series is presented from our Hospital, including patients who developed RBS after direct-to-implant reconstruction with ADM between January 2022 and December 2024. Twenty-nine studies met the inclusion criteria, comprising case reports, case series, and retrospective or prospective cohort studies. The reported incidence of RBS ranged from 0% to 29.6%. Proposed etiologies include endotoxin contamination, residual cellular debris, delayed hypersensitivity reactions, and lymphatic or vascular impairment of mastectomy flaps. Most reports described localized erythema confined to the area of the ADM, with normal inflammatory markers and negative imaging findings, whereas antibiotic therapy frequently failed to achieve improvement. Corticosteroids represented the most consistently effective treatment, although some cases required ADM removal or replacement. In our institutional case series (n = 8), symptom onset occurred between 4 weeks and 7 months postsurgery. Inflammatory markers remained within normal limits, imaging rarely demonstrated fluid collections, and symptoms resolved within days to weeks with corticosteroid therapy or conservative management. This review consolidates current evidence, proposes a diagnostic-therapeutic algorithm and highlights the need for prospective investigations and manufacturer-level endotoxin testing to elucidate pathogenesis and optimize clinical management. Level of Evidence: 2 (Risk) For image description, please refer to the figure legend and surrounding text.

Humans

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Effects of erector spinae plane block on postoperative pain in patients undergoing implant-based breast reconstruction for breast cancer: a randomized controlled trial.

BACKGROUND: Implant-based breast reconstruction after mastectomy causes acute pain. OBJECTIVE: To determine whether a single-shot T5 erector spinae plane block (ESPB) reduces postoperative pain. DESIGN: Single-center, RCT with allocation concealment; blinded assessors and statisticians. SETTING: Tertiary cancer center in China. PATIENTS: 100 adults scheduled for radical mastectomy with implant reconstruction were randomized (1:1); follow-up complete. INTERVENTION: Before induction, ESPB was given under ultrasound guidance at T5 with 30 mL of 0.375% ropivacaine plus dexmedetomidine 1 &#x3bc;g/kg; controls received no block. Standardized general anesthesia and postoperative PCA for both groups. MAIN OUTCOME MEASURES: Resting NRS at 6 h (MCID=1). Secondary outcomes were opioid consumption, quality of recovery, and PONV. RESULTS: ESPB did not significantly reduce resting pain at 6 h at the median (&#x3c4; =0.50; adjusted difference -0.9; p = 0.08). At the upper tail, pain intensity was lower (&#x3c4; = 0.75; -1.8; p <0.01). Repeated measures provided additional time-point information, improving estimation precision and test sensitivity. ESPB get lower pain scores at 6, 12, and 24 hours (all p <0.01). But, the 95% CI includes the MCID, the clinical benefit remains uncertain. Opioid use decreased at 24 h (-13.5 mg; p <0.01) and 48 h (-6.6 mg; p <0.01). Quality of recovery improved at 24 h (difference 5 points; p <0.01), but not later. No differences were observed in intraoperative hemodynamics or PONV. CONCLUSIONS: Single-shot T5 ESPB with perineural dexmedetomidine may reduce postoperative pain and opioid requirements and improve early recovery. Further large trials are warranted. Clinical relevance remains to be confirmed. TRIAL REGISTRATION: ClinicalTrials.gov NCT06143020.

Humans

Bioabsorbable vs. titanium screws in first metatarsophalangeal joint arthrodesis: a pilot randomized controlled trial with 2-year follow-up.

INTRODUCTION: To assess the feasibility and preliminary clinical outcomes of bioabsorbable screw fixation in first metatarsophalangeal joint arthrodesis compared to conventional titanium screw fixation. METHODS: In this prospective pilot randomized controlled trial, 30 patients were allocated 1:1 to bioabsorbable or titanium cannulated lag screw fixation. Arthrodesis was performed using a cup-and-cone technique at two Finnish hospitals. Full weight-bearing in an orthopaedic shoe was allowed after six weeks. Outcomes included AOFAS and VA-FAS FA-VAS scores, union rates, and complications assessed at 3, 6, 12, and 24 months. RESULTS: Both groups showed significant functional improvement with no between-group differences. At 24 months, mean AOFAS scores were 89.1 (SD 2.7) in the titanium group and 90.0 (SD 0.0) in the bioabsorbable group (p = 0.23). Mean FA-VAS total scores (sum of pain, function, and complaints subscales) were 1948 (SE 59.4) in the titanium group and 1914 (SE 61.4) in the bioabsorbable group (p = 0.655). Union rate was 90% overall; nonunion occurred in one titanium and two bioabsorbable patients, all requiring revision. No implant-related complications or hardware removal surgeries were recorded. Degradation of bioabsorbable screws caused no adverse clinical or radiographic reactions. CONCLUSIONS: Bioabsorbable screws appear safe and feasible in first metatarsophalangeal joint arthrodesis, with preliminary outcomes comparable to titanium fixation. These findings support the conduct of a larger confirmatory trial. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03133039, registered 28 April 2017. https://clinicaltrials.gov/ct2/show/NCT03133039.

Humans

Hysteroscopic platelet-rich plasma and medically assisted reproduction outcomes: a systematic review and SWOT analysis.

BACKGROUND: Platelet-rich plasma (PRP) has been proposed as an adjuvant treatment in reproductive medicine. While most evidence refers to blind intrauterine instillation, subendometrial administration under hysteroscopic guidance allows targeted delivery under direct visualisation. This systematic review aimed to synthesise the available evidence on hysteroscopic PRP administration and its impact on clinical medically assisted reproduction (MAR) outcomes. METHODS: A systematic search was conducted from inception to December 2025 across major databases. Studies were included if they evaluated hysteroscopic PRP administration in women undergoing MAR, comparing reproductive outcomes between treated and control groups. RESULTS: Out of 142 records, 3 studies met the inclusion criteria. Study populations were heterogeneous and included women with refractory thin endometrium and/or a history of implantation failure. Hysteroscopic PRP administration protocols varied in timing, technique, and dosage. In a prospective case-control study, hysteroscopic intraendometrial PRP injection at a depth of 2-3&#x2009;mm in the four uterine walls, using an ovum aspiration needle, on days 11-13 of the cycle prior to euploid frozen embryo transfer (ET), was associated with higher implantation (IR), clinical pregnancy (CPR), and live birth rates (LBR) compared with standard therapy. Conversely, no significant differences in CPR, miscarriage rate, or LBR were observed in an observational study evaluating a single intraendometrial PRP injection (35-40&#x2009;mL, 2-3&#x2009;mm depth), administered via endoscopic needle on days 6-8 of the menstrual cycle preceding frozen ET, alone or after electrical impulse therapy. A randomised controlled trial in women undergoing intrauterine insemination reported a significant improvement in CPR following hysteroscopic subendometrial PRP instillation in the four uterine walls (1.0&#x2009;mL each). CONCLUSIONS: Current literature on hysteroscopic PRP administration in reproductive medicine is limited, and robust conclusions cannot yet be drawn. Well-designed randomised controlled trials with standardised protocols are needed to clarify its clinical role.

Humans

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Current Concepts and Emerging Technologies in Aesthetic Outcome Assessment of Breast Reconstruction.

Aesthetic outcomes are a crucial determinant of the overall success of breast reconstruction. Recently, aesthetic assessment has evolved from relying mainly on subjective impressions to incorporating more quantitative methods. This systematic review summarizes current concepts and emerging technologies in aesthetic outcome assessment after breast reconstruction. A comprehensive search of studies evaluating aesthetic outcomes following implant-based, autologous or hybrid breast reconstruction was performed between 2000 and 2025. Assessments were classified as subjective or objective. Extracted variables included assessment characteristics, aesthetic outcome domains, and patient-centered outcomes. Risk of bias was assessed using the Joanna Briggs Institute Critical Appraisal Checklist. Levels of evidence were classified according to the Oxford Centre for Evidence-Based Medicine. A total of 51 studies involving 7711 participants from 16 countries were included. Subjective tools were most frequently employed, led by the BREAST-Q (35/51, 69%), followed by expert- or panel-based evaluations (17/51, 33%) and the visual analog scale (2/51, 4%). Objective methods were applied in 19 studies and included 3-dimensional surface imaging (8/51, 16%), BCCT.core (7/51, 14%), eye tracking (3/51, 6%), and artificial intelligence-based analyses (3/51, 6%). Although subjective tools captured satisfaction with breast appearance, objective tools quantified morphological parameters and positional landmarks. BREAST-Q remains the cornerstone of outcome evaluation after breast reconstruction, providing patient-centered perspectives, including, but not limited to, aesthetic perception. A progressive shift toward multimodal evaluation was noticed, as no single modality comprehensively addressed all aesthetic domains. Future research should focus on integrating subjective and objective assessment methods within a unified framework. Level of Evidence: 3 (Therapeutic) For image description, please refer to the figure legend and surrounding text.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Viscoelastic-Assisted Patient Interface Docking: A Technical Optimization in LenSx Femtosecond Laser-Assisted Cataract Surgery.

PURPOSE: To evaluate the efficacy of viscoelastic-assisted patient interface docking in LenSx (Alcon Laboratories, Inc) femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a randomized controlled trial. Patients undergoing FLACS from January to August 2025 at Aier Eye Hospital of Wuhan University were randomized via a random number table to receive balanced salt solution (BSS) or visoeleastic as the patient interface docking medium. The primary outcome was docking efficiency, measured by one-time docking success rate, the number of docking attempts, and mean docking time. Secondary outcomes included surgical safety (subconjunctival hemorrhage, capsulotomy completeness/tear rate), laser treatment duration (anterior capsulotomy time, nucleus pretreatment time, total laser emission time), and patient comfort (post-laser pain sensation). RESULTS: A total of 100 patients were enrolled, 50 in each group. Suction loss occurred in 7 patients (14%) in the BSS group and 1 patient (2%) in the viscoelastic group; the one-time docking success rate was significantly higher in the viscoelastic group (98%) than in the BSS group (86%) (chi-square = 3.93, P < .05). The viscoelastic group also had fewer mean docking attempts (1.02 &#xb1; 0.14) than the BSS group (1.16 &#xb1; 0.42), showing a significant difference (t = 2.23, P < .05). The viscoelastic group exhibited significantly shorter mean docking time (44.66 &#xb1; 4.47 seconds) compared to the BSS group (48.62 &#xb1; 3.11 seconds) (t = 2.17, P < .05). No significant differences were observed between the groups in subconjunctival hemorrhage, capsulotomy completeness/tear rate, anterior capsulotomy time, nucleus pretreatment time, total femtosecond laser emission time, or patient-reported pain sensation (all P > .05). CONCLUSIONS: Viscoelastic-assisted patient interface docking in FLACS effectively elevates one-time docking success rate, reduces docking attempts, and shortens docking time.

Humans

Aortoesophageal Fistula: Mending the Lethal Connection-A Systematic Review and Meta-Analysis.

BACKGROUND: Aortoesophageal fistula (AEF) is a rare, life-threatening condition with limited high-quality evidence to guide management. METHODS: We conducted a systematic review and meta-analysis of PubMed and Scopus through December 2025, evaluating survival and complication outcomes according to treatment strategy and morphological severity. Patients were categorized into 5 groups: TEVAR alone, staged TEVAR followed by surgery, primary open or hybrid surgery, TEVAR with esophageal stenting, and supportive/palliative care. Outcomes were pooled as proportions with 95% confidence intervals (CIs). RESULTS: A total of 167 reports representing 528 patients were included. Overall 30-day mortality was 31.2% (95% CI 27.0% to 35.7%) and 1-year mortality 41.2% (95% CI 36.2% to 46.4%). Infection occurred in 32.6%, reintervention in 20.2%, and recurrence in 13.2%. Staged TEVAR followed by surgery showed favorable survival (30-day 12.7%, 1-year 26.1%) but high infection (66.7%) and reintervention (43.2%) rates. TEVAR with esophageal stenting had the lowest early mortality (5.0%) but frequent reintervention (54.5%) and 1-year mortality of 33.3%. TEVAR alone demonstrated the lowest 1-year mortality among definitive strategies (25.5%) but notable recurrence (26.9%). Primary open or hybrid surgery carried higher early and late mortality, while supportive/palliative care had the worst outcomes. Morphological severity correlated strongly with mortality, infection, reintervention, and recurrence, with type IV lesions showing particularly poor prognosis. CONCLUSION: Despite contemporary management, AEF carries high early and late mortality. Definitive strategies, particularly staged TEVAR followed by surgery, offer improved survival but increased complications. Morphology-guided, individualized management is recommended.

Adult

Efficacy and Safety of Autologous Versus Prosthetic Grafts in the Repair of Popliteal Artery Aneurysms: A Systematic Review and Meta-Analysis.

BACKGROUND: Popliteal artery aneurysms (PAAs) present a severe risk of progression to acute limb ischemia. Open surgery (OS) is the gold standard treatment; however, prosthetic grafts are acceptable in highly selected cases, especially when the great saphenous vein is not available. METHODS: We performed a systematic review and meta-analysis of studies comparing autologous versus prosthetic grafts for patency and limb preservation outcomes in patients with PAAs. MEDLINE, Embase, and Cochrane Central were systematically searched from inception through October 2024. Outcomes were pooled using a frequentist random-effects model as odds ratios, mean differences, and hazard ratios (HRs) with 95% confidence intervals (CIs) on RStudio (Version 4.5.0). Risk-of-bias assessments were performed using ROBINS-I and MINORS. RESULTS: Twenty-two observational studies were pooled comprising 9,145 PAAs in 8,370 patients, of whom 6,434 (74.51%) were treated with autologous grafts and 2,200 (25.49%) with prosthetic grafts. Follow-up ranged from 12 to 86 months. Repair with autologous conduits significantly improved long-term primary patency (HR 3.93; P < 0.001), secondary patency (HR 6.02; P < 0.001), and long-term limb salvage (HR 2.69; P = 0.044) compared with prosthetic conduits. There were no significant differences in in-hospital amputation (P = 0.36), myocardial infarction (P = 0.61), mortality (P = 0.50), 2-year primary patency (P = 0.25), 5-year secondary patency (P = 0.06), or length of hospital stay (P = 0.95). Risk of bias was classified as moderate-to-high, reflecting confounding factors inherent to observational studies and moderate methodological quality by MINORS. Despite these limitations, treatment effects consistently favored autologous grafts in both short- and long-term analyses; however, caution is warranted given the limited number of available studies. CONCLUSION: The use of autologous conduits significantly favors both short-term and long-term efficacy and safety in the OS repair of PAAs. Given the limitations of the existing evidence, further comparative studies are needed.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Prophylactic Surgical Left Atrial Appendage Closure in Bioprosthetic Aortic Valve Replacement: Short-Term Outcomes of Randomized Controlled LAA-CLOSURE Trial.

BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF. METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73&#x2009;years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30&#x2009;days. RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at &#x2248;7&#x2009;days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7&#x2009;days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30&#x2009;days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively. CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding. REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT02321137.

Aged

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study.

BACKGROUND: Retention of metal implants after Scarf-Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. METHODS: This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). RESULTS: Both groups showed significant clinical and radiographic improvement (P&#x202f;<&#x202f;0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P&#x202f;>&#x202f;0.05). Treatment costs were significantly lower in the K-wire group (P&#x202f;<&#x202f;0.001). CONCLUSIONS: K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. LEVEL OF EVIDENCE: Level III.

Humans