Results for “PCR assay monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Simple, quantitative primer-extension PCR assay for direct monitoring of microRNAs and short-interfering RNAs.

There has been a surge of interest in the biology of microRNAs and the technology of RNA interference. We describe a simple, robust, inexpensive assay for quantitative analysis of microRNAs and short-interfering RNAs. The method relies on primer extension conversion of RNA to cDNA by reverse transcription followed by quantitative, real-time PCR. Technical parameters critical to the success of the assay are presented. Measurements of microRNA levels are sensitive, with most assays allowing measurements in the femtomolar range, which corresponds to tens of copies per cell or less. The assay has a high dynamic range and provides linear readout over differences in microRNA concentrations that span 6-7 orders of magnitude. The assay is capable of discriminating between related microRNA family members that differ by subtle sequence differences. We used the method for quantitative analysis of six microRNAs across 12 tissue samples. The data confirm striking variation in the patterns of expression of these noncoding regulatory RNAs.

DNA Primers↗

Comparative study of a modified competitive RT-PCR and Amplicor HCV monitor assays for quantitation of hepatitis C virus RNA in serum.

A modified competitive RT-PCR (mcRT-PCR) to measure HCV RNA in serum and the Amplicor HCV Monitor assay were compared. For mcRT-PCR, the RNA extracted was retrotranscribed and coamplified in one step with a known amount of a DNA internal control (IC). Digoxigenin-labeled amplified products were hybridized to specific HCV DNA and IC-DNA probes and quantified by colorimetry. HCV RNA concentration was calculated by plotting the ratio of HCV/IC ODs against a calibration curve. Multiple samples were analyzed in the same round and tedious titration of each sample with a competitor was unnecessary. The mcRT-PCR assay was linear from 6 x 10(3) to 6 x 10(7) copies/ml, whereas Amplicor was linear up to 1-2 x 10(6) copies/ml. HCV RNA was measured in samples from 75 carriers. There was agreement between both methods in type 1 infections but not in type 2 or type 3 infections, in which the values measured by Amplicor were, on average, 15 times lower than those measured by the mcRT-PCR. HCV RNA measured by Amplicor was higher in type 1 infections than in type 2 or 3 infections, but no differences were found when viral load was assessed by mcRT-PCR. The binding efficiency of the Amplicor-probe was greater for type 1 than for types 2 or 3, suggesting Amplicor underestimates the viral load in the latter types. In contrast, the mcRT-PCR is not affected by genotype-related variation of HCV. This study suggests that mcRT-PCR assay is reliable for sensitive and accurate measurement of HCV RNA over a broad range of values independently of the HCV genotype.

Genotype↗

Evaluation of the AMPLICOR CMV, COBAS AMPLICOR CMV monitor and antigenemia assay for cytomegalovirus disease.

The AMPLICOR CMV (qualitative DNA assay by PCR), COBAS AMPLICOR CMV Monitor (quantitative DNA assay by PCR), and antigenemia assay were tested for their ability to diagnose cytomegalovirus (CMV) infection in 115 immunocompromised patients. The AMPLICOR qualitative assay and the antigenemia assay were positive for all nine patients with a clinical diagnosis of CMV disease. The AMPLICOR quantitative assay was negative for one of the nine patients. In 106 patients without CMV disease, the AMPLICOR qualitative test was positive in 22, the quantitative test was positive in 23, and the antigenemia test was positive in 55 patients. The AMPLICOR qualitative and quantitative assays had specificities of 79% and 78% in patients without CMV disease, while that of the antigenemia assay was 48%. Diagnostic efficiencies were 79% for the AMPLICOR qualitative assay, 69% for the AMPLICOR quantitative assay, and 48% for the antigenemia assay. All three tests yielded positive results before, or at the same time as, the onset of CMV disease in most cases, which suggests they can be used to predict disease before the onset of symptoms. During antiviral treatment, test results tended to decrease quantitatively and finally became negative; negative results were followed by remission of symptoms. This suggests that the AMPLICOR quantitative assay and the antigenemia assay could be useful for monitoring therapeutic efficacy. The AMPLICOR qualitative and quantitative assays, as well as the antigenemia assay were considered effective for all of the following: diagnosing CMV disease, predicting the onset of disease, and evaluating the effectiveness of antiviral chemotherapy. The antigenemia assay was at times difficult to perform in the case of severely neutropenic patients, whereas the AMPLICOR assays could be used in such cases.

Antigens, Viral↗

Monitoring of cytomegalovirus infection in solid-organ transplant recipients by an ultrasensitive plasma PCR assay.

Early and accurate monitoring of cytomegalovirus (CMV) infection in solid-organ transplant recipients is of major importance. We have assessed the potential benefit of an ultrasensitive plasma-based PCR assay for renal transplant recipients. The pp65 CMV antigen (pp65 Ag) assay using leukocytes was employed as a routine test for the monitoring of CMV in 23 transplant recipients. We compared the pp65 antigenemia with the CMV load quantified by an ultrasensitive PCR (US-PCR) with a limit of detection of 20 CMV DNA copies/ml of plasma. CMV infection was detected in 215 (67%) of 321 plasma samples by the US-PCR compared with 124 (39%) of 321 samples by the pp65 Ag assay. The US-PCR assay permitted the detection of CMV infection episodes following transplantation a median of 12 days earlier than the pp65 Ag assay. Moreover, during CMV infection episodes, DNA detection by the US-PCR was consistently positive, whereas false negative results were frequently observed with the pp65 Ag assay. We found a good correlation between the two assays, and the peak viral loads were significantly higher in patients with CMV-related complications (median, 5000 DNA copies/ml) than in those without symptoms (1160 DNA copies/ml) (P = 0.048). In addition, patients that did not require preemptive therapy based on the results of the pp65 assay had CMV loads significantly lower (median, 36 DNA copies/ml) than those that needed treatment (median, 4703 DNA copies/ml) (P < 0.001). These observations provided cutoff levels that could be applied in clinical practice. The ultrasensitive plasma-based PCR detected CMV infection episodes earlier and provided more consistent results than the pp65 Ag assay. This test could improve the monitoring of CMV infection or reactivation in renal transplant recipients.

Cytomegalovirus↗

Quantitative real-time PCR with automated sample preparation for diagnosis and monitoring of cytomegalovirus infection in bone marrow transplant patients.

BACKGROUND: In bone marrow and stem cell transplant patients, the widespread use of preemptive cytomegalovirus (CMV) antiviral therapy necessitates faster, more precise, and more sensitive quantitative laboratory methods for serial viral load monitoring. METHODS: We developed a novel CMV viral load assay using real-time PCR of plasma DNA prepared by an automated robotic workstation. Fluorescent hybridization probes directed at the glycoprotein B (gB) gene (or EcoRI D region) of CMV were used to detect and quantify PCR products. The beta-globin gene was amplified in parallel to control for the efficiency of the extraction and PCR steps. RESULTS: The assay was linear (R = 0.999) from a lower detection limit of 125 copies/mL to 5 x 10(9) copies/mL with a PCR efficiency of 1.975 (gB) or 2.02 (EcoRI D). The viral loads determined by PCRs directed at these two different viral targets were no different (n = 53; R = 0.928). The interassay CV was 3.5%, and the intraassay CV was 1-4%. Compared with a commercially available quantitative competitive PCR assay (Roche MONITOR; R = 0.59), the mean CMV viral load by real-time PCR was 3.1 times higher (mean ratio; P = 0.002). The diagnostic sensitivity and specificity of the real-time assay were 96% and 100%, respectively (n = 147), compared with 74% and 98% for a qualitative PCR assay (Roche AMPLICOR). On a subset of samples, the diagnostic sensitivity of viral culture was no greater than 50% (n = 44). Of 1115 clinical referral samples from 252 patients, 10% of the samples and 18% of the patients had low-level CMV viremia (median, 500 copies/mL). In this predominantly (85%) bone marrow transplant testing cohort, serial CMV viral load results were the predominant clinical trigger for the initiation, monitoring, and cessation of preemptive antiviral therapy. CONCLUSIONS: The combination of automated DNA preparation and semiautomated real-time fluorescent PCR detection allows for a sensitive, precise, and accurate high-throughput assay of CMV viral load that can be used as the laboratory trigger for preemptive antiviral therapy.

Antiviral Agents↗

Advantages of real-time PCR assay for diagnosis and monitoring of canine leishmaniosis.

The aim of the present study is to highlight the advantages of real-time quantitative PCR intended to aid in the diagnosis and monitoring of canine leishmaniosis. Diagnosis of canine leishmaniosis is extremely challenging, especially in endemic areas, due to the diverse and non-specific clinical manifestations, and due to the high seroprevalence rate in sub-clinical dogs. Veterinarian clinicians are usually confronted with cases that are compatible with the disease, and with several diagnostic tests, sometimes with contradictory results. We have developed a new TaqMan assay, targeting the kinetoplast, applied to 44 samples of bone marrow aspirate or peripheral blood. The dynamic range of detection of Leishmania DNA was established in 7 logs and the limit of detection is 0.001 parasites in the PCR reaction. At the time of diagnosis parasitemia ranges from less than 1 to 10(7)parasites/ml. The ability to quantify the parasite burden allowed: (i) to elucidate the status of positive dogs by conventional PCR, although larger studies are necessary to clarify the dividing line between infection and disease, (ii) to estimate the kinetics of the parasite load and the different response to the treatment in a follow-up and (iii) to validate blood as less invasive sample for qPCR. The continuous data provided by real-time qPCR could solve the dilemma for the clinician managing cases of canine leishmaniosis by differentiating between Leishmania-infected dogs or dogs with active disease of leishmaniosis.

Animals↗

Polymerase chain reaction assay for pertussis: simultaneous detection and discrimination of Bordetella pertussis and Bordetella parapertussis.

A polymerase chain reaction (PCR) assay which allows the simultaneous detection and discrimination of the two causative agents of pertussis, Bordetella pertussis and Bordetella parapertussis, was developed. Primer pairs were based on insertion sequence elements IS481 and IS1001. IS481 is specific for B. pertussis and is present in about 80 copies per cell, while IS1001 is specific for B. parapertussis and is found in 20 copies per cell. An internal control was included in the PCR assay to monitor the performance of the PCR and to identify possible inhibitory components in clinical samples. Discrimination of amplified DNA derived from the internal control, B. pertussis, or B. parapertussis was accomplished by differential spacing of the primers. The sensitivity of the combined PCR method was found to be very high and allowed the detection of one cell of either pathogen. The usefulness of the method was investigated by using a limited number of clinical samples derived from patients with serologically proven pertussis.

Base Sequence↗

Highly sensitive patient-specific real-time PCR SNP assay for chimerism monitoring after allogeneic stem cell transplantation.

Chimerism analysis after allogeneic stem cell transplantation (allo-SCT) is an important diagnostic tool for the documentation of engraftment, early detection of graft failure, and recurrence of the disease. Current assays rely on the genetic polymorphism between the donor and the recipient, and allow semiquantitative or quantitative analysis of chimerism. The most common method in use is based on the amplification of the short tandem repeats (STR). This method, with 1% to 5 sensitivity, is useful for the documentation of engraftment, but is insufficient for the detection of minimal residual disease or early relapse, when medical intervention is urgently needed. Recently, single-nucleotide polymorphism (SNP) has been suggested as an alternative, more accurate system to monitor chimerism. The purpose of our study was to develop an easy, economical, and sensitive method for the detection of chimerism following allo-SCT using the SNP technology. Our approach is based on SNP patient-specific quantitative real-time polymerase chain reaction (PCR) using nonlabeled primers. Our results show that this allele-specific SNP real-time PCR approach is sensitive, relatively cheap, and offers a fast and reliable assay for the monitoring of hematopoietic engraftment and for the detection of minimal residual disease in patients after allo-SCT.

Female↗

Cytomegalovirus antigenemia assay or PCR can be used to monitor ganciclovir treatment in bone marrow transplant recipients.

The antigenemia assay, polymerase chain reaction (PCR) and rapid culture technique on buffy coat cells (DEAFF test) were used to monitor 37 cytomegalovirus (CMV) seropositive bone marrow transplant (BMT) recipients for active CMV infection during the first 3 months after BMT. The antigen assay and PCR demonstrated a comparable sensitivity for the detection of CMV in blood: discordant results were only obtained in the early or late phase of infection when the viral load was low. The antigen assay was more sensitive than the DEAFF test. Only 12 out of 40 antigen-positive samples yielded a positive result with DEAFF test, whereas viremia without antigenemia was never found. The discordance between these two tests increased further during antiviral therapy with ganciclovir. A correlation was observed between the duration of antigenemia during treatment and the recurrence of systemic CMV reactivation. Ten out of 11 patients with antigen-positive leukocytes present for more than 1 week after starting the treatment subsequently exhibited a relapse of active infection, whereas only three out of nine patients who resolved their antigenemia within 1 week did so. In conclusion, the antigen assay and PCR are useful techniques for detection of CMV infection in BMT patients. Test results obtained during therapy give reliable information regarding the viral load and the possibility of recurrence of antigenemia, and can be taken into account when prolonged administration of ganciclovir is considered.

Antigens, Viral↗

Clinical evaluation and applications of the Amplicor HBV Monitor test, a quantitative HBV DNA PCR assay.

Viral load has emerged recently as a reliable marker of disease progression and therapeutic efficacy in chronic infections, including AIDS and hepatitis C. The clinical management of type B hepatitis could also be improved by monitoring viremia levels in patients with chronic liver disease undergoing anti-viral treatment. To address this question we evaluated the performance of a newly developed, quantitative PCR assay (Amplicor HBV Monitor test, Roche Diagnostic Systems) in the assessment of viremia changes over time in a group of 45 patients with chronic active hepatitis (CAH) who received interferon treatment. Of the 45 patients, 14 were HBsAg and anti-HBeAg positive and 31 HBsAg, HBeAg positive. Follow-up extended up to 24 months. An average of ten samples per patient were analyzed for levels of ALT, IgM anti-HBc (Abbott Laboratories), HBV DNA by in-house dot-blot hybridization and hybridization-capture assays (HBV-DNA hybrid capture kit, Murex Diagnostics) and by Amplicor HBV Monitor. A sustained biochemical response was observed at the end of treatment in 12 HBeAg-positive and in seven anti-HBeAg positive patients. This was accompanied by the disappearance of HBeAg and of HBV DNA (hybridization assays) in all cases and by the clearance of IgM anti-HBc in 70% of the cases. Viremia (quantitative PCR assay) became undetectable only in 25-30% of cases and was associated with the loss of HBsAg. A good correlation was observed between the time course of IgM anti-HBc, quantitative PCR and dot-blot hybridization although the latter missed 33% of viremic samples. Together, these results indicate that the Amplicor HBV Monitor test is a robust and standardized assay for quantifying HBV viremia levels in the range from 10(2) to 10(7) copies/ml. Compared to other current markers, viral load may provide additional clinical information by predicting long term virologic response and HBsAg clearance in patients with normal ALT at the end of interferon therapy.

Adult↗

Application of real-time PCR to quantify hepatitis B virus DNA in chronic carriers in The Gambia.

BACKGROUND/AIM: The study aimed at developing a real-time quantitative PCR assay to monitor HBV serum virus load of chronic carriers enrolled in therapeutic trials. METHOD: Quantitative real-time PCR assay was carried out using SYBR-Green signal detection and primers specific to the S gene. Thermal cycling was performed in an ABi 5700 sequence detection system. The assay was calibrated against an international HBV DNA standard and inter- and intra-assay reproducibility determined. Levels of viral load were monitored for 1-year in lamivudine treated carriers. Correlation between HBV DNA levels and HBeAg sero-status was determined in untreated carriers. RESULTS: The qPCR assay showed good intra- and inter-assay reproducibility over a wide dynamic range (1.5 x 103 to 1.5 x 108 copies/mL) and correlated well with those from a commercial assay (r = 0.91, (p < 0.001). Viral load levels dropped dramatically but temporarily during and after a short course of lamivudine therapy. HBV DNA was a more reliable indicator of the presence of virus than HBe antigen and was detected in 77.0% (161/209) of HBeAg negative and in all HBeAg positive carriers. CONCLUSION: This method is reliable, accurate, and reproducible. HBV DNA Quantification by qPCR can be used to monitor the efficacy of HBV therapy and useful in understanding the natural history of HBV in an endemic area.

Adolescent↗

Comparison of a duplex quantitative real-time PCR assay and the COBAS Amplicor CMV Monitor test for detection of cytomegalovirus.

A duplex quantitative real-time PCR (qPCR) assay was designed to detect both the polymerase gene (pol) and the glycoprotein gene (gB) of cytomegalovirus (CMV). The detection limit of the qPCR was determined to be 1 to 3 copies/reaction and the linear measure interval was 10(3) to 10(8) copies/ml. The qPCR system was compared to the COBAS Amplicor CMV Monitor test (COBAS) by an analysis of 138 plasma samples. Both systems detected CMV in 71 cases and had negative results for 33 samples. In addition, 34 samples were positive by qPCR and negative by the COBAS assay, but in no case was the COBAS result positive and the qPCR result negative. Thus, qPCR detected 48% more positive cases than the COBAS method. For samples with > or = 10(5) copies/ml by qPCR, a saturation effect was seen in the COBAS assay and quantification required dilution. Copy numbers for pol and gB by qPCR generally agreed. However, the reproducibility of qPCR assays and the need for an international standard are discussed. Discrepant copy numbers for pol and gB by qPCR were found for samples from two patients, and sequence analysis revealed that the corresponding CMV strains were mismatched at four nucleotide positions compared with the gB fragment primer sequences. In conclusion, a duplex qPCR assay in a real-time format facilitates quantitative measurements and minimizes the risk of false-negative results.

Base Sequence↗

Fusion of bovine leukemia virus with target cells monitored by R18 fluorescence and PCR assays.

PCR and R18 fluorescence dequenching assays have been combined to monitor the kinetics of fusion of bovine leukemia virus with target cells (CC81, OVK, or Raji). Antibodies raised against gp51 allow us to demonstrate that not only the hydrophobic N-terminal domain of the transmembrane glycoprotein gp30 but also specific domains of gp51 (amino acids 39 to 103) are involved in bovine leukemia virus-cell fusion.

Animals↗

Comparison of quantitative cDNA-PCR with the branched DNA hybridization assay for monitoring plasma hepatitis C virus RNA levels in haemophilia patients participating in a controlled interferon trial.

The branched DNA (bDNA) assay was compared with a semi-quantitative cDNA-polymerase chain reaction (cDNA-PCR) assay for monitoring HCV RNA levels in plasma in 17 haemophilia patients participating in a controlled alpha-interferon trial. Good correlation between the HCV RNA levels as detected by the two assays was observed, with a correlation co-efficient of 0.83 (P < 0.0001) and 0.90 (P < 0.0001) at week 0 and 24, respectively. Hepatitis C virus RNA (HCV RNA) levels could be assessed with the bDNA assay in 14/17 (82 percent) HCV cDNA-PCR positive pretreatment samples. The bDNA assay apparently failed to detect low viral titres. Interferon treated patients (n = 11) showed either a complete response, being a large reduction in HCV RNA level to below the detection limit of the HCV cDNA-PCR assay (6/11) or no significant reduction in HCV RNA level (5/11). A "partial" virological response was not observed. The changes in HCV RNA plasma levels in non-responders during interferon (IFN) treatment were similar to the (small) natural fluctuations in viral load observed in controls (untreated patients). Although the bDNA assay was not as sensitive as cDNA-PCR, given its user friendliness and quantitative results, it is concluded that it is a useful test for monitoring HCV RNA levels in patients treated with interferon. However, patients who are non-reactive in the bDNA assay have to be retested by cDNA-PCR because low viral titres are not detected by the bDNA assay.

Alanine Transaminase↗

Comparison of two quantitative CMV PCR tests, Cobas Amplicor CMV Monitor and TaqMan assay, and pp65-antigenemia assay in the determination of viral loads from peripheral blood of organ transplant patients.

BACKGROUND: Quantitative PCR assays have become the most common methods in the determination of viral load during cytomegalovirus (CMV) infection of transplant patients. However, usually these tests are still quite time-consuming and labor-intensive which diminishes their utility of these tests in routine diagnostic laboratories. OBJECTIVES: The objective of this study was to develop a quantitative CMV PCR test which is time-saving and easy to perform for the detection and monitoring of CMV infection of transplant patients. STUDY DESIGN: The quantitative real time CMV PCR assay using TaqMan chemistry and an automated sample preparation system, MagNA Pure LC, was developed. The designed quantitative CMV test was compared to commercial quantitative PCR test, Cobas Amplicor Monitor, in the determination of CMV DNA loads in plasma samples of liver and kidney transplant patients. The results were also correlated with the CMV pp65-antigenemia test. The clinical material of 270 blood specimens of transplant patients were tested using these two PCR methods and pp65-antigenemia test in parallel. Plasma samples were used for PCR assays and leucocytes for the antigenemia test. RESULTS: The TaqMan assay described was easy to perform, it was rapid (3-4 h) and hands-on time needed for performing the test was short. The detection limit of the assay was 250 copies/ml (cps/ml) plasma and the linear range up to 25,000,000 cps/ml. TaqMan assay was the most sensitive test detecting 92% of the CMV positive findings. Cobas Monitor detected 80% and pp65 test 88% of the positive findings. The correlations between TaqMan and antigenemia assays, and between Cobas Amplicor and antigenemia were statistically significant and high, R = 0.84 (P < 0.0001) and R = 0.80 (P < 0.0001), respectively. Also correlation between two PCR tests was statistically significant (R = 0.64, P < 0.0001). Of the 27 patient studied, 19 demonstrated CMV antigenemia and DNAemia in their blood during the post transplant monitoring. Thirteen of these patients developed a symptomatic CMV infection and were treated with ganciclovir. The peak viral loads of symptomatic patients were statistically higher by all three methods than those of asymptomatic patients. CONCLUSIONS: The developed real time TaqMan assay was rapid and easily performed and could be the best alternative for the diagnosis of CMV infection and monitoring of liver and kidney transplant patients.

Cytomegalovirus↗

Comparison of quantitative competitive PCR with LightCycler-based PCR for measuring Epstein-Barr virus DNA load in clinical specimens.

The aim of this study was to develop a LightCycler-based real-time PCR assay for monitoring the Epstein-Barr virus (EBV) DNA load in unfractionated whole blood. This assay was compared with quantitative competitive PCR (Q-PCR) for EBV. The LightCycler-based assay was highly sensitive and reproducible when quantifying plasmid DNA in either the presence or absence of healthy donor blood DNA. Amplifying plasmid DNA in DNA backgrounds from different donors slightly increased the variation of quantification, indicating that clinical specimen DNA has an influence on quantification. In most transplant recipients, a good correlation was observed between EBV DNA load dynamics determined by LightCycler and Q-PCR in follow-up samples, although the correlation between absolute values of EBV DNA loads was weak and occasional samples were false negative in the LightCycler assay. In 253 cross-sectional blood samples from patients with Burkitt's lymphoma, infectious mononucleosis, or human immunodeficiency virus infection, a weak but significant correlation between the two methods was found (r(2) = 0.37, P < 0.001). Our results indicate that the clinical specimen DNA background may influence the absolute values of EBV DNA load in LightCycler analyses but that this effect is rare. LightCycler PCR is very well suited for monitoring of EBV DNA load dynamics, and its diagnostic value is comparable to that of Q-PCR. To avoid false negativity or underestimation of viral load, future internal calibration of the LightCycler is recommended. This would also enhance EBV load assay standardization and interinstitute comparisons.

DNA, Viral↗

Validation of a polymerase chain reaction assay for monitoring the therapeutic efficacy of diminazene aceturate in trypanosome-infected sheep.

The diagnostic performance of a polymerase chain reaction assay (PCR) for monitoring the effectiveness of aceturate diminazene treatment was compared with those of an antibody-detection ELISA test and the buffy-coat technique using sheep experimentally infected with either savannah-type or forest-type Trypanosoma congolense or T. vivax. Within the period of infection, the PCR using specific savannah-type T. congolense primers showed a significant higher diagnostic sensitivity (p<0.05) than the buffy-coat technique. Both techniques gave closed results for detecting forest-type T. congolense or T. vivax infections. Following trypanocidal treatment, the PCR showed that specific product disappeared definitively 1 or 2 days later in animals in which a decrease of the antibody level and a significant improvement of the red packed cell volume were observed. The occurrence of relapse infection was detected by the PCR in one animal infected by T. vivax on day 19 post-treatment and confirmed by the persistence and increasing antibody level whereas the buffy-coat technique detected parasites 42 days later. Then, the PCR signals remained positive on several occasions while parasitaemia was detected only two times.The application of PCR combined with the antibody detection appeared to provide a useful tool as compared to the buffy-coat technique for monitoring the effectiveness of trypanocidal treatment.

Animals↗

Diagnosis and monitoring of murine histoplasmosis by a nested PCR assay.

A newly developed nested PCR assay was applied to murine models of histoplasmosis. ICR and BALB/c mice were intravenously infected with Histoplasma capsulatum and sacrificed up to 29 days later. Samples of blood, spleen, and lung homogenates were cultured and examined by the PCR assay. In the ICR mouse model, 265 of 319 organ samples showed concordant results. With 7 samples, the culture was positive and the PCR assay was negative whereas a positive PCR but a negative culture were obtained with 47 samples (P < 0.0001 according to McNemar's test). Organ homogenates and blood samples of either spontaneously cured or treated BALB/c mice were PCR negative. The nested PCR assay performs excellently in the monitoring of spontaneously and treatment-cured murine histoplasmosis. It limits the infection risks of the laboratory staff and might be of diagnostic value for humans.

Animals↗