Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Neoprene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Neoprene wet-suit hood affects low-frequency underwater hearing thresholds.

INTRODUCTION: Psychophysical measures of wet-suit hood sound attenuation are needed to provide the diving community with guidance on protection from underwater sound. METHODS: Underwater hearing thresholds were obtained from 15 male and 5 female recreational divers with and without a 3-mm thick wet-suit hood. Dives were conducted at a depth of 1 m in a large quiet anechoic pool. Thresholds were determined using a two-interval forced-choice procedure with a 0.71 probability of positive response at convergence. A 1-s pure tone was presented with a 20-ms rise and fall time at 100, 200, 250, 300, 400, and 500 Hz. RESULTS: Without a wet-suit hood, mean thresholds decreased from 99 dB re 1 microPa at 100 Hz to 85 dB at 500 Hz. Thresholds were statistically similar at 100 to 300 Hz with and without the wet-suit hood, but were significantly increased at 400 and 500 Hz with the hood (p < 0.001). CONCLUSIONS: In conclusion, at shallow depths, a 3-mm neoprene wet-suit hood attenuates underwater sound by approximately 10 dB for frequencies between 400 Hz and 500 Hz. At frequencies below 400 Hz, a 3-mm neoprene wet-suit hood offers no sound protection.

Adult↗

[Surgical experience with 50 transplantations of neoprene-occluded segmental pancreas. Technique and postoperative complications].

UNLABELLED: Since the beginning of our pancreas transplantation program in November, 1987, 50 patients have received a segmental intraperitoneal neoprene-occluded pancreas graft and a contralateral kidney graft. The aim of this study is to present our surgical technique and the postoperative complications encountered. Operation in the donor: subtotal pancreatectomy is performed. A venous patch is preserved at the end of the splenic vein. The splenic artery is removed with a patch taken from the end of the celiac trunk and the origin of the common hepatic artery, even in case of right (n = 1) or left (n = 4) hepatic artery. The canal is injected with neoprene (2 to 3 cc) ex vivo and the pancreatic parenchyma is recut after stappling. Operation in the recipient: the transplant is inserted in an extraperitoneal location, between the bladder and the pubic arch, then anastomosed to the external iliac vessels. RESULTS: All pancreas grafts functioned immediately. All patients but 3 are alive at present. Seven pancreas transplants were lost postoperatively due to venous thrombosis (n = 3), hemorrhage (n = 3) and death at D27 (n = 1). Many patients developed peripancreatic fluid collections and/or fistulae (the most frequent complication, probably due to the extraperitoneal site of transplantation). The actuarial survival rate of the patients, kidneys and pancreas after 2 years is 96%, 92% and 80%, respectively.

Actuarial Analysis↗

Thermal oxidative decomposition studies of neoprene compositions.

Four neoprene compositions--uncured gum, known cured rubber, cable insulation, and hose conduit, the latter two used in underground mining--were subjected to thermal oxidative degradation under static and dynamic environments, and the volatile products were quantitated on a milligrams-per-gram basis. In a quiescent system at 370 degrees C, no glow was observed, the extent of oxidation was low, up to 84% of the chlorine content was evolved as hydrogen chloride, and the sulfur present was released largely in the form of carbon disulfide. Under more drastic conditions (higher temperatures and flowing air), glow occurred in several instances resulting in an increased production oxidation products as represented by CO2, COS, SO2, HCOOH, and CH3COOH, among others. Thermogravimetric investigations of the neoprene compositions show the first weight loss to correlate closely with hydrogen chloride evolution; furthermore, the use of thermogravimetric curves as means of meterial differentiation appears to offer a definite promise.

Air Pollution↗

Pathology of the pancreas after intraductal neoprene injection in dogs and diabetic patients treated by pancreatic transplantation.

The injection of neoprene into the pancreatic ducts of dogs has been used to destroy exocrine function prior to pancreatic transplantation. The subsequent histological changes and the evolution of lesions over a period of 3-36 months are described. Animals were sacrificed or biopsied at various intervals (3, 15 and 36 months) and the pancreases showed the disappearance of exocrine acini and changes of chronic pancreatitis. An immunoperoxidase procedure with insulin, glucagon, somatostatin and pancreatic polypeptide antisera was used to show the persistence of pancreatic endocrine cells. After the injections, sclerosis progressively increased and secondary lesions of the islets were seen, although functional islets persisted. This technique was then applied to pancreas transplantation in man. Eight transplants from seven diabetic patients were available for examination. In four cases, there were early technical failures, but four pancreatic transplants continued to function for 28-889 days until suppuration destroyed one of the grafts and the three other patients died. The persistence of endocrine cells in sclerotic tissue was observed in histological and immunopathological examinations.

Adult↗

A preliminary investigation of the neoprene tube finger extension splint.

Neoprene tube finger extension splints were analyzed to determine the production, amounts, and directions of force magnitude on the proximal interphalangeal joint during the flexing of the tube up to angles of 80 degrees. The tubes were examined in their empty form, with a human digit inserted into the tube, and with portions of the tube on the volar and dorsal surfaces removed. Upward forces ranged from less than 100 g to 225 g in the empty tubes. Upon insertion of a human digit into the tubes, forces increased from 125 g at 10 degrees to 650 g at 80 degrees flexion. Removal of a 2-cm square portion on the dorsal surface over the PIP joint did not significantly affect the tube's ability to lift upward demonstrating little or no downward pressure in the device. The tube had little or no upward force following removal of a 2-cm square encompassing the angle of the device on the volar surface. Positive effectiveness of the tubes were examined in case reports.

Adult↗

A breakthrough time comparison of nitrile and neoprene glove materials produced by different glove manufacturers.

Specimens of similar nominal thickness from commercially available nitrile and neoprene gloves were each tested for breakthrough time against three chemicals. The null hypothesis was that the breakthrough times for the glove specimens of the same generic type but produced by different manufacturers would be the same. Breakthrough time data for each material/chemical combination were analyzed using an analysis of covariance to adjust for differences in the measured specimen thickness while testing for product differences. A significant difference in chemical breakthrough times was found among generically similar products produced by different manufacturers. The largest difference between the mean breakthrough time of two generically equivalent products, 30 vs. 300 min, was obtained for perchloroethylene through nitrile products. In conclusion, breakthrough time data for use in selection of chemical protective clothing or in prediction modeling for chemical protective clothing should be manufacturer and product specific.

Acetates↗

Permeation of neoprene protective gloves by acetone: comparison of three different permeation cells in an open-loop system.

The increased interest in protective capacity of chemical protective clothing materials has resulted in an increasing number of reports from permeation testing, performed by various test procedures and with permeation cells of different configurations. To make it possible to compare the resultant data, it is necessary to identify what parameters will have a decisive influence on test results. The influence of various carrier gas flow rates on breakthrough time and permeation rate of acetone through gloves made of neoprene was investigated using three permeation cells of different configurations. The breakthrough times were not influenced by cell design or gas flow rate. On the other hand, both cell configuration and gas flow rate influenced the steady-state permeation rate.

Acetone↗

The use of a neoprene "thumb-sock" to prevent trauma in a thumb-sucking child with intractable epilepsy.

A nine-year-old girl with spastic quadriplegia, mental retardation, poor vision, a gastrostomy, and intractable epilepsy was referred by her pediatrician for a dental assessment with a view to extracting her anterior teeth as a means of preventing repeated damage to the skin over the proximal phalanx of her left thumb, which she sucked at night. This was the time of day when the frequency of her epileptic seizures was highest. A simple solution to the problem was developed by a dentist and an occupational therapist in which nylon-coated 3-mm neoprene sheeting (wet-suit material) was formed into a "thumb-sock" with a simple Velcro fastening around the wrist. No trauma to the thumb from epileptic seizures has occurred since the "thumb-sock" was fitted 24 months ago.

Child↗

Quantification of prosthetic outcomes: elastomeric gel liner with locking pin suspension versus polyethylene foam liner with neoprene sleeve suspension.

For this randomized crossover trial, we compared two common transtibial socket suspension systems: the Alpha liner with distal locking pin and the Pe-Lite liner with neoprene suspension sleeve. Our original hypotheses asserted that increased ambulatory activity, wear time, comfort, and satisfaction would be found with the elastomeric suspension system. Thirteen subjects completed the study. Following 2.5-month accommodation to each condition, ambulatory activity was recorded (steps/minute for 2 weeks), and subjects completed three questionnaires specific to prosthesis use and pain: the Prosthesis Evaluation Questionnaire (PEQ), a Brief Pain Inventory (BPI) excerpt, and the Socket Comfort Score (SCS). Upon completion, subjects selected their favored system for continued use. Ten subjects preferred the Pe-Lite and three the Alpha. Subjects spent 82% more time wearing the Pe-Lite and took 83% more steps per day. Ambulatory intensity distribution did not differ between systems. No statistically significant differences were found in questionnaire results. Subject feedback for each system was both positive and negative.

Adult↗

[Allergic contact eczema because of diethylthiourea in neoprene rubber].

Three cases are reported of acute allergic contact dermatitis caused by diethylthiourea in the neoprene rubber used in a diving suit and orthopedic braces. Patch testing should be done with the specific thiourea compounds, because testing with material from the suspected products may be negative. Cross-reactivity between thiourea compounds is uncommon.

Adult↗

Splinting the degenerative basal joint: custom-made or prefabricated neoprene?

The purpose of this study was to compare the objective, subjective, and radiographic responses of patients with carpometacarpal joint osteoarthritis (CMCJ-OA) wearing a prefabricated neoprene splint (PFN), which crosses the CMCJ and metacarpophalangeal joint, with those of patients wearing a custom-made thermoplastic short opponens splint (CMT), which crosses only the CMCJ. Patients ( N = 25) with first CMCJ stage I and II osteoarthritis were assigned randomly to wear either the PFN splint or the CMT splint for one week. After one week, the subjects rated their function in the splint and their satisfaction and pain levels on visual analogue scales. Pinch measurements were performed and x-rays were taken to assess carpometacarpal subluxation. The second splint was then applied for one week and all measures were repeated. The subjects rated the PFN splint significantly higher, and most reported that they would choose the PFN splint over the CMT splint for daily and long-term use. Both pain and function were improved with splinting, but the effect was amplified with the PFN splint compared with the CMT splint. Both splints reduced subluxation at the first carpometacarpal joint, but the CMT effect was greater. This study further supports current evidence that subjects with stage I and II first CMCJ-OA will have pain relief with thumb splinting. In addition, the PFN splint will provide greater relief when compared with the CMT splint. Furthermore, this study reveals that patients prefer the PFN splint to the CMT splint.

Cross-Over Studies↗

[A new method of pancreatic transplantation. 1 - Effects on the dog pancreas of the intraduct injection of neoprene (author's transl)].

Injection into the pancreatic ducts of a synthetic liquid gum (neoprene), which polymerises when it comes into contact with the fluid secreted by the gland, would appear to be a simple and effective means of suppressing exocrine secretion of the pancreas in the dog. Endocrine secretion was remained in the short and mid-term. The therapeutic implications of this new technique in the preparation of pancreatic transplants are discussed.

Amylases↗

Progress in segmental neoprene-injected pancreas transplantation. Advantages and disadvantages of using Cyclosporin A.

We performed 39 neoprene-injected pancreatic transplants (38 segmental and 1 total) in 37 insulin-dependent diabetic recipients from October 1976 to May 1983. The best results were obtained when the pancreas was transplanted simultaneously with the kidney (25 cases). The use of Cyclosporin A (CyA) for immunosuppression did not reduce the early pancreatic failures, but it seems to have slightly improved the long-term survival. The glycaemic control was better in patients treated by CyA alone than in those receiving steroids. The main side effects of CyA were nephrotoxicity and some immunoglobulin abnormalities with or without lymphoproliferative disorders occurring after treatment with CyA and ALG.

Adult↗

Clinical experience with renal and neoprene-injected segmental pancreatic allografts in man.

We describe 22 clinical cases of segmental pancreatic grafts that were prepared with neoprene injection in the pancreatic duct. Complete correction of the diabetes is obtained during the period of function of the graft. The surgical procedure is a safe one and does not lead to a higher surgical risk than the usual kidney transplantation. Progress should be made by early detection and effective treatment of the pancreatic graft rejection. Corticoids should be avoided to suppress the diabetogenic effect. Cyclosporine A will probably be the immunosuppressive of choice.

Adolescent↗

Effect of a neoprene sleeve on knee joint kinesthesis: influence of different testing procedures.

PURPOSE: Objectives of this study were to examine the perceived sense of knee joint position during selected test situations, and to evaluate the proposed kinesthetic effect of a neoprene knee sleeve during these test situations. METHODS: Fifty-nine young healthy subjects (39 females and 20 males) attempted to replicate target knee joint angles using active and passive knee extension movements completed in sitting (nonaxially loaded) situations, and during active knee extension movements completed in supine while applying a load of 15% body weight through the long axis of the tibia (axially loaded). The criterion measure used was the absolute difference between target and reproduced angles, averaged over five attempts (Average absolute difference: AAD). RESULTS: A three-way ANOVA (two genders by three test situations by two sleeve conditions), with repeated measures on the last two factors, indicated a significant main effect for test situation and sleeve condition (P < 0.05), but not for gender. There was also a significant test situation by sleeve condition interaction (P < 0.05). Post-hoc analysis indicated that the AAD score during the active nonaxially loaded test situation without the sleeve was significantly greater than AAD scores for all other tests (P < 0.01). CONCLUSIONS: Pre-existing differences in knee joint kinesthesis observed during different contexts of limb movement must be recognized before various interventions, including the effect of knee supports, can be adequately interpreted. Because knee joint position sense was attenuated during voluntary active movement, and because this attenuation was ameliorated by the use of a sleeve, future studies evaluating the kinesthetic effects of knee bracing may benefit from using active movements. However, since the sleeve did not affect performance during the axially loaded test situation, future studies should also evaluate the relationship between tests of knee joint kinesthesis and other more functional tests of neuromuscular performance.

Adult↗